Loading…
Loading…
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
5 Sept 2026, 6:00 pm
GARRISON ENGINEER SAUGOR
Garrison Engineer Saugor Military Engineer services Garrison Engineer Saugor MP- 470001
REPAIR/ REPLACEMENT OF LT CABLE, OH LINE AND CONNECTED ALLIED WORKS UNDER GE SAUGOR
2026_MES_784365_1
GE/SGR/TOK-62 OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Saugor
Class D category b (i) and as per tender documents
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER SAGAR
₹80,000
Yes
13 Aug 2026
13 Aug 2026
7 Sept 2026
13 Aug 2026
5 Sept 2026
29 Aug 2026
13 Aug 2026 - 20 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240Sqmm 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. Make- Havells/KEI/Gloster/Polycab | 100 | RM | - | - |
| - | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150Sqmm 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. Make- Havells/KEI/Gloster/Polycab | 200 | RM | - | - |
| - | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70Sqmm 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. Make- Havells/KEI/Gloster/Polycab | 500 | RM | - | - |
| - | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50Sqmm 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. . Make- Havells/KEI/Gloster/Polycab | 500 | RM | - | - |
| - | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35Sqmm 3.5 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. Make- Havells/KEI/Gloster/Polycab | 500 | RM | - | - |
| - | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16Sqmm 4 core including taking down existing unserviceable cable and removing from sitecomplete all as specified and directed. Make- Havells/KEI/Gloster/Polycab | 300 | RM | - | - |
| - | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10Sqmm 4 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. Make- Havells/KEI/Gloster/Polycab | 200 | RM | - | - |
| - | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10Sqmm 2 core including taking down existing unserviceable cable and removing from site complete all as specified and directed. Make- Havells/KEI/Gloster/Polycab | 500 | RM | - | - |
| - | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed. | 621 | Cum | - | - |
| - | Excavation in trenches exc 1.5m and n exc 3.0 m depth in any type of soil and complete all as specified and directed. | 0.5 | Cum | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
GP_SC_SCPSTOK62.pdf
Tender Documents • 1.39 MB
BOQ_878862.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].