Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-AOC NOT SPECIFIED | L1 | Accepted-AOC techno-commercially eligible L-1 bidder. | |
| 2 | Rejected-Technical 40004093 BINDU KISAN SINGH WARD NO 4 GUJAR KHEDI SAONER NAGPUR 441107 | NAGPUR | MAHARASHTRA | 441107 | - | Rejected-Technical As per NIT | |
| 3 | Rejected-Technical AT SAMET ELECTRO TOWER TAMRIT MARKET COMPLEX ROOM NO 15 HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | - | Rejected-Technical As per NIT |
Tender Value
₹3.5 L
EMD Value
₹4,400
Closing Date
28 Oct 2024, 5:00 pmClosed
STAFF OFFICER (ENM), HINGULA AREA
STAFF OFFICER(ENM), OFFICE OF THE GM HINGULA AREA, MCL, TALCHERPO NS NAGAR, ANGUL, ODISHA, 759148
Making arrangement of power supply and Electrical wiring for weigh bridge 11, 12 and new dispatch room Hingula OCP.
2024_MCL_319272_1
MCL/GM/HA/EnM/ e-Tender/24-25/94 Dt.16.10.24
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
HINGULA OCP
AS PER NIT
4 documents required · 4 mandatory
₹4,400
Yes
30 Jan 2025
17 Oct 2024
30 Oct 2024
17 Oct 2024
28 Oct 2024
18 Oct 2024
17 Oct 2024 - 21 Oct 2024
Amount
Item Description/ Heading
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm
Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required 100A TPN
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. (Group A)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. (Group B)
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc as required. 40 amps
Supplying and fixing 5 A to 32 A rating, 240/415 V, "C" curve, miniature circuit breaker suitable for inductive load of Double poles in the existing MOB DB complete with connections, testing and commissioning etc. as required. Double pole
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying & fixing 8 way, Doubledoor, single pole & neutral, sheetsteel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar, Interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB /Isolator).
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box incl connection but excluding modular plate etc as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25mm x 5mm GI strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with GI nut, bolt, spring, washer etc. as required. (jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm)
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 15/16 amps switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet
Supply and fixing of 18 watt LED tube light
Supply and fixing of 9 watt LED bulb
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 6.5 meter and upto 8.0 meter
Erection of angle iron/ channel iron cross arm on steel tubular pole as reqd.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
SAI TRADERS
TARENI ELECTRICALS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .