Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC 00 RL QR NO 388 B KALIBARI COLONY ALIPURDUAR JN JALPAIGURI WEST BENGAL 736123 | ALIPURDUAR | WEST BENGAL | 736123 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.6 L+₹6,303.94 (1.15%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹5.6 L+₹12,205.46 (2.22%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹5.5 L
EMD Value
₹6,000
Closing Date
16 Dec 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, EDC, BDN
BUDAUN
45/EDCB/2024-25
2024_MVVNL_978325_1
45/EDCB/2024-25
Open Tender
Electrical Works
Item Rate
90 days
BUDAUN
AS PER TENDER DOCUMENT
3 documents required · 3 mandatory
₹1,180
A/c No. 1243002100806171, IFSC Code - PUNB0124300
₹6,000
26 May 2025
30 Nov 2024
17 Dec 2024
30 Nov 2024
16 Dec 2024
30 Nov 2024
30 Nov 2024 - 16 Dec 2024
Amount
The work of safe carriage of the following material from store center Nawada to work site under the jurisdiction of EDD-II, Budaun Approx. distance upto 0-60 Km. Including safe loading and unloading.
P.C.C. Pole 8.5 Mtr Long
ST Pole 11 MTR Long
LT ABC (3x95+1x70+1x16) SQ. MM
LT ABC (3x120+1x95+1x16) SQ. MM
ACSR Rabbit Conductor
Three Phase Distribution Box
Earthing Complete
Stay set Complete
Stay Wire 7/10 Swg
Dropper Channel 100x50MM
Top Channel 100x50x2240
11 Kv Polimic Pin Insulator
11 Kv Polymeric Disc Insulator
GI Wire 6 Swg
GI Wire 8 Swg
GI Wire 10 Swg
TEE-Off Channel
MS Angle 75x75x6x2028
Guarding Angle 50x50x5x2500MM
Cross Arm V-Type 11kv
The following Decentralized material shall be provided by the contractor for execution of work as per RESPO Norms (the material shall be purchased from approved vendor of Discom).
Three Phase Distribution Box Clamp (LS)
Dead End Clamp
Eye Hook
J Hook
Extra For Stay at Angle Location
LT Shackle Insulator
LT Clamp
Clamps with Bolt & Nut
Stone Pad
T, Dropper, Top Channel Clamp for ST/PCC Pole
Cross Arm Holding Clamp
F-Clamp
Stay Clamp
Danger Board with Clamp
Aluminum Paint
Number Plate
Cost of LT Tailess Unit (400A) with 12 no. AI Lugs for 400 sqmm
Erection of the following support including cutting, making holes fixing of all types of accessories digging of pits complete in all respect as per RESSPO norms.
Double pole of ST Pole 11 Mtr. Long. for 100/250 KVA T/F
Single support of ST Pole 11 Mtr. Long.
Single support of PCC Pole 8.5 Mtr. Long.
Grouting of following poles with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/CC & sand Required as per RESSPO Norms. (All Grouting material shall be provided by the contractor).
Double pole of ST Pole 11 Mtr. Long.
Single support of ST Pole 11 Mtr. Long.
Single support of PCC Pole 8.5 Mtr. Long.
Laying, Stringing, Sagging & Jumpring of Following Conductor complete in all respect as per RESSPO Norms.
LT ABC (3x95+1x70+1x16) SQ. MM
LT ABC (3x120+1x95+1x16) SQ. MM
ACSR Rabbit Conductor
The work of driving the earthing electrode and making connections with GI wire.
Erection/Fixing of stay set with stay wire and clamp as per RESSPO norms including binding. climbing, clamping, tightening and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 of cement, sand and C.C. and sand etc. as per RESSPO norms. All the grouting material shall be provided by the contractor
Painting of ST Pole 11 Mtr. long. supports with one coat of red Oxide primer and two coats of aluminum white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5 Mtr. Upper portion of support) Paint and material shall be provided by the contractor.
Fixing of danger plate on each location including proper clamping as per RESSPO Norms (Danger Board with clamps & bolts, nuts shall be provided by the contractor)
Fixing of number plate on each location including proper clamping as per RESSPO Norms (Number Plate with clamps & bolts, nuts shall be provided by the contractor)
Guarding of HT/LT/Telephone Line/Road/River crossing etc. and making net with suitable difference. Completely including fixing of all channel/angle etc. with proper locking at each support. All type nut & bolt shall be provided by the contractor.
Construction of 250 KVA T/F plinth 1.5x1.5x2 Mtr. for mounting T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect as per RESSPO Norms.
Cage fencing of 250 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8’(H) by strenghtening of wire mesh 20x3 mm M.S. flat haorizentally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All men, material and T&P provided by the contractor to complete the fabrication, transportation and installation.
Pipe Earthing of Transformer (By boring of 4 inch diameter 20 m deep, 40 mm diameter A Class GI pipe is inserted to a depth of 20 m and a holed pipe of 1.5m length is inserted at the bottom, Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work contractor will provide all material, manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE)
Erraction/Fixing of Tailess Unit (400 A) (Tailess Unit shall be provided by the contractor as per RESSPO Norms). complete in all respect as per
Errection and commissioning of 3 Phase Distribution Box on the LT Poles (All the material required shall be arranged by the contractor for errection and commissioning of distribution boxes except distribution box).
Dismantling and removing of following T/F,s and double pole and shifting at site of the work complete in all respect as per RESSPO Norms.
11/0.4 KV 100 KVA T/F
11/0.4 KV 250 KVA T/F
Mounting of following Transformer as per norms complete in all respect
11/0.4 KV 100 KVA T/F
11/0.4 KV 250 KVA T/F
Dismantling and removing of following 11/LT Lines and poles as per norms complete in all respect.
LT ABC (3x95+1x70+1x16) SQ. MM
LT ABC (3x120+1x95+1x16) SQ. MM
ACSR Rabbit Conductor
Safe back carriage of Following item (if any) from work site to Store Center, Nawada, Budaun approx distance upto 0-60 Km including loading & unloading.
A.B. Cable Scrap
Iron Scrap
STP Pole Scrap
ACSR Weasel Conductor Scrap
M/S TIWARI TRADING COMPANY (BID ID -4791535)
M/S RAHAT & BROTHERS ELECTRICALS (BID ID -4775231)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .