| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.2 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹53.2 L | L1 | Accepted-AOC SINCE L1 BIDDER |
| 2 | L2₹58.6 L+₹5.3 L (10.1%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹58.6 L+₹5.3 L (10.1%) | L2 | Rejected-Finance SINCE NOT L1 BIDDER |
| 3 | L3₹68.7 L+₹15.5 L (29.2%)Rejected-Finance | ₹68.7 L+₹15.5 L (29.2%) | L3 | Rejected-Finance SINCE NOT L1 BIDDER |
| 4 | L4₹72.7 L+₹19.5 L (36.6%)Rejected-Finance VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | ₹72.7 L+₹19.5 L (36.6%) | L4 | Rejected-Finance SINCE NOT L1 BIDDER |
| 5 | L5₹73.6 L+₹20.4 L (38.3%)Rejected-Finance 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹73.6 L+₹20.4 L (38.3%) | L5 | Rejected-Finance SINCE NOT L1 BIDDER |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
9 Sept 2023, 6:00 pmClosed
CWE AMRITSAR CANTT
HQ CWE AMRITSAR OLD CANTT
PROVN OF HIGH MAST SECURITY LIGHTS IN OLD AMRITSAR CANTT AND GG FORT UNDER AMWP 2023-24
2023_MES_613131_1
CWE/ASR-16/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE AMRITSAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE AMRITSAR
₹1.9 L
Yes
20 Dec 2023
10 Aug 2023
16 Sept 2023
10 Aug 2023
9 Sept 2023
4 Sept 2023
Amount
Supply install test and commissioning of 12.5 mtr motorised (integral motor not les than 0.75 HP with mechanical tripping facility), high mast system with crane, winch double drum SWL-350 Kgs, tailing cable copper 5 core, 2.5 sqmm PVC insulated and accessories alongwith complete material with BSEN10025 steel plate avg 70 micron hot deep galvanised internally and externally, minimum 12 sided polygonal, base 360 mm dia and top 150 mm, base flange dia 445 mm, 3 mm thickness for both top and bottom sections (2 piece pole) minimum 04 No foundation bolts size M24/750x4, stainless steel 304 grade with rope 7/19 construction, 180 Km / Sec wind speed design with 08 Nos of 250 W LED flood light (Cat No PRAZE F 300L WH NB-A5 TG SD of bajaj or equivalent in Philips / Crompton) and out put shall be > 120 lumens per watt, toughened glass additional 10 KV surge protection inside fitting over and above 4 KV inbuilt driver surge protector, IP-66 PROTECTION, pf>0.95, THD<10%, potted driver with ROHS compliance, UE, CE marking certification, driven efficiency >90%, Power 120-270 V, AC 50 Hz each LED shall have individual peanut lenses including avaiatiion obstruction light, lightning arrestor with suitable feeder panel supplied by OEM, with astronomical time switch, contactors and suitable MCB protection. Make for high mast and LED Fittings : Philips / Bajaj / Crompton or other equivalent makes of Appendix 'B' Note : (i) The rate quoted shall be inclusive of excavation and earth work for foundatiion and also inclusive of RCC foundation as per manufactureres instruction and drgs. (ii) The contractor shall procure the items OEM only and the same shall be verified by GE. (iii) The Accepting Officer will detail the inspection officer at the factory for inspection of poles before despatch and the same will be in scope of contrcator to make arrangement for testing at factory and nothing extra will be paid on that account. (iv) The make fitting shall be same as that of pole make. (v) The contractor shall give 5 years warranty on LED light fittings.
Supply install test and commissioning of 16 mtr motorised (integral motor not les than 0.75 HP with mechanical tripping facility), high mast system with crane, winch double drum SWL-350 Kgs, tailing cable copper 5 core, 2.5 sqmm PVC insulated and accessories alongwith complete material with BSEN10025 steel plate avg 70 micron hot deep galvanised internally and externally, minimum 12 sided polygonal, base 410 mm dia and top 150 mm, base flange dia 490 mm, 3 mm thickness for both top and bottom sections (2 piece pole) minimum 08 No foundation bolts size M30/850x8, stainless steel 304 grade with rope 7/19 construction, 180 Km / Sec wind speed design with 08 Nos of 250 W LED flood light (Cat No PRAZE F 300L WH NB-A5 TG SD of bajaj or equivalent in Philips / Crompton) and out put shall be > 120 lumens per watt, toughened glass additional 10 KV surge protection inside fitting over and above 4 KV inbuilt driver surge protector, IP-66 PROTECTION, pf>0.95, THD<10%, potted driver with ROHS compliance, UE, CE marking certification, driven efficiency >90%, Power 120-270 V, AC 50 Hz each LED shall have individual peanut lenses including avaiatiion obstruction light, lightning arrestor with suitable feeder panel supplied by OEM, with astronomical time switch, contactors and suitable MCB protection. Make for high mast and LED Fittings : Philips / Bajaj / Crompton or other equivalent makes of Appendix 'B'. Note : (i) The rate quoted shall be inclusive of excavation and earth work for foundatiion and also inclusive of RCC foundation as per manufactureres instruction and drgs. (ii) The contractor shall procure the items OEM only and the same shall be verified by GE. (iii) The Accepting Officer will detail the inspection officer at the factory for inspection of poles before despatch and the same will be in scope of contrcator to make arrangement for testing at factory and nothing extra will be paid on that account. (iv) The make fitting shall be same as that of pole make. (v) The contractor shall give 5 years warranty on LED light fittings.
Supply & laying in trenches/drawn through pipes or in road crossing/paths/drains/along poles etc., of XLPE insulated, armoured with multistranded aluminium conductor cable conforming to IS-7098 Part-I (1998), heavy duty (LT UG cable) conforming to IS-1554, 1100 Volts grade of size 10 sqmm 4 core nominal cross sectional area including connecting up using suitable size double compression copper gland, testing and commissioning complete all as specified and directed NOTE: 1) Excavation, earthwork & cable protection etc. will be measured and paid separately under relevant items of this schedule. 2) The cables teriminated in the panels / busbars / high mast poles shall be provided with heat shrinkable cable end joints and the rate quoted shall be inclusive of the same.
Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying cables and getting out in soft/loose soil and in road cutting all as specified and as directed
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed
Removing excavated material/surplus soil not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above starting point complete all as specified and as directed
Supply & laying double wall corrugated (DWC) high density poly ethylene (HDPE) of size 50mm dia including all necessary fittings, PN-4 rating, pressure 6 Kgf/cm², conforming to IS-16205 (Part-24) with high ring stiffness & cursh resistance capacity, etc., laid in trench for protection of cable complete all as directed.
Material & Labour in repairs earthing complete with galvanised earth plate electrode 600mm X 600mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 metres below ground level) with top edge of earth plate not less than 1.5metres below normal ground level, connected to GI strip of size 25 x 4mm by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No.3 of MES SSR 2009, Part – I (Specifications) and connected to main switch board/LT feeder panel including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in alternate layers with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150mm both ways center to center with suitable lifting handle to cover, earth pit made of PCC 1:3:6 type C-1, GI protection pipe light grade 40 mm bore up to 7.5metres length from earth electrode including testing complete all as specified and directed NOTE: (i) Earth lead and protection pipe beyond 7.5 m shall be measured and Paid separately. (ii) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt. (iii) The earthing shall be done in the presence of JE / Engineer-in-charge and if done in the absence of JE/Engineer-in-Charge the same will not be measured and paid contractor has to redo the complete earthing as directed.
Bus bar chamber out door type of size 600 mm x 450mm x 300mm made out of 3.15 mm thick CRCA sheet duly powder coated with hinged door and consting of MCCB 80-100 and incomer and Bus bar 200 amps capacIty 04 Nos on epoxy insulators incl RYB LED indicator and Outgoing MCB TPN 32 amps 415 V 10 KA - 02 nos and 63 amps MCB TPN 415V 10 KA-01 No. with locking arrangement and suitable stand made of 40x40x5mm thick MS angle iron of length 90 cm.complete all as directed by Engineer-in-Charge( Note - the Bus bar chamder drg will be approved by the contractor from GE before manufactring)
kailu construction co
Choice india
M/s Sahib and Company
JCC ENGINEERS PRIVATE LIMITED
Raman Electric Trading Co
M/s Ravinder Kapoor Engineers and Builders
Vardhman Airport Solutions Pvt Ltd
SATISH AND CO
DIVYA ELECTRIC CORPOORATION
J and K constructions company
POONAM ELECTRIC INDUSTRY
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .