| 1 | L1₹22.4 LAccepted-AOC RANGIYA STATION ROAD WARD NO 2 PO RANGIYA DIST KAMRUP ASSAM PIN 781365 | BAKSA | ASSAM | 781365 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹25.6 L+₹2.2 L (9.58%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹27.0 L+₹3.6 L (15.6%)Rejected-Finance 0 BINOVA NAGAR KAMRUP ASSAM 781018 | KAMRUP METRO | ASSAM | 781018 | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹27.4 L+₹4.1 L (17.5%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
19 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NARANGI
GE Narangi C/O 99 APO Guwahati
CERTAIN MISC REPAIRS TO VARIOUS MES INSTALLATIONS IN THE AOR OF AGE B/R I AND AGE B R II UNDER GE NARANGI
2020_MES_406222_1
8593/B/E8
Open Tender
Civil Works
Works
270 days
GE NARANGI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NARANGI
₹50,000
Yes
28 Jan 2021
23 Dec 2020
23 Jan 2021
23 Dec 2020
19 Jan 2021
5 Jan 2021
60 days
Amount
SCHEDULE 'A' PART-I
Demolition of brick work, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and pre-cast concrete articles complete all as directed.
Dismantling of plain or corrugated steel sheeting, any gauge or any thickness in roof covering all as directed. Note : Serviceable sheets shall be kept aside for reuse and unserviceable sheets shall be removed from site complete all as directed.
Dismantling of asbestos cement sheet (corrugated or semi corrugated etc) as in roofing complete all as specified and as directed.
Demolition of plain cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thick, above or below ground level complete all as specified and as directed.
Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description complete all as directed.
Dismantling timber scantling 40 Sqcm and over in section in any position (unframed work) complete all as directed.
Taking down chowkats with shutters, area n.exc. 1.5 Sqm each (without taking off shutters from the frame) complete all as directed.
Taking down chowkats with shutters, area exc 1.5 Sqm but n.exc. 4 Sqm each (without taking off shutters from the frame) complete all as directed.
Taking down shutter of any description, area exc 1 sqm but nexc 2 sqm each all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing complete all as specified and as directed.
Demolition of stone slab and tiles of any description or thickness in floor apron etc laid, bedded and pointed in cement mortar complete all as directed.
Dismantling, posts or struts(wood, steel or RCC) any section, including taking out embedded portion in natural ground and making good disturbed ground etc complete all as directed.
Dismantling posts or struts embedded in concrete (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as directed.
Dismantling fencing wire mesh, any type including connected mild steel flats complete all as directed.
M&Lfor hard core with broken stone or boulder of gauge not exc 63 mm, deposited , spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed
M&L for PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M&L for providing reinforced cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) in precast posts, fencing post, straining or terminal posts, struts etc. for fencing, average sectional area exceeding 100 sqcm and n exc 250 sqcm with or without chamfered angles and flat, splayed, rounded or mitred tops complete all as specified and as directed. Note:- Reinforcement will be measured and paid seperately)
M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan, exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
All as per item No 19 here in before but except bricks. Note: Old serviceable bricks as obtained from demolition under item no. 1 here-in-before shall be reused under this item complete all as specified and as directed.
M&L for brick work with sub class ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and as directed.
M&L for 2nd class hard wood in scantling, clean sawn timber and fixed in position etc complete all as directed
S&F 30 mm thick flush shutter, solid core construction with particle board core and plywood face panel, commercial type on both side complete all as specified and directed.
S&F cold rolled mild steel butt hinges, 100 mm long, medium weight all as specified and directed.
S&F aluminium barrel tower bolt, 150 mm long,extruded section all as specified and as directed.
S&F aluminium handle 150 mm long, extruded section all as specified and as directed.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy all as specified and directed
S & F in repairs, aluminium body door closer hydraulically regulated, designation No. 2 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg complete all as specified and as directed.
S & F stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless wire staples complete all as specified and as directed.
S & F in repairs stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless wire staples complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia as in reinforcement bar complete all as specified and as directed.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed.
M&L for mild steel rolled sections of FE-410W (Grade E 250) Quality B, as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates all as specified and as directed.
M&L for rolled mild steel work in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes and painted with one shop coat of zinc chromate primer paint complete, tubes conforming to IS 1161-1979, grade St-240 all as specified and as directed.
S&F rolled mild steel plates (plain or chequered), channels, square cut ot notched (ordinary and counter sunk), forming holes, without any attachment conforming to fe 410-W(gde-E-250) quality -A as in duct cover complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section confirming to Fe 290 (Gde-E-165) with gusset plates, rails braces, etc. complete drilled for fixing of steel sheeting with and including Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete all as specified and directed.
S&F 1.25mm thick mild steel, plain, black sheet in cladding of steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
S&F 1mm thick mild steel, plain black sheet in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; waters tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size, edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed.
S&F mild steel angle/flat iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. including all necessary drilling, bolting or riveting and similar work conforming to Fe- 290 Gde E-165 etc complete all as specified and directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and diameter of shank 5 to 10mm completed all as specified and as directed.
M&L for welding in repairs, n. exc 2.5cm in length & n. exc. 6mm thickness of metal to be welded complete all as directed.
M&L for running welding in repairs, not exceeding 6 mm thickness of metal to be welded complete all as directed.
S&F steel windows with side hung shutters both mosquito proof and glazed shutter including projecting type hinges with steel handle and steel peg stay with glazing bars and 12 mm square bar or guard bar of approved design welded to steel window frame dovetailed or welded including making good disturbed surface in cement mortar (1:2) or PCC (1:2:4) type B-1 after steel work fixed complete all as specified and as directed .
S & F anodized aluminium push pull type partly panelled and partly glazed door shutter single leaf including necessary jointing cleats, glazing clips, rubber packing, snap beading, screws, handle, locking arrangement, 12 mm thick pre laminated particle board, interior grade pre laminated with decorative face laminations both sides on bottom panel and 5.5 mm thick float glass tinted quality on top panel, 1 No of aluminium door closer per leaf (Diecast) body hydraulically regulated, designation No 3, universal type completecomplete all as specified and as directed. (Refer Jindal Cat Main-2016) Aluminium sections : (i) Shutter top, bottom middle rails :- 85.00 mm x 44.45 mm x 1.40 mm thick (19600) (ii) Shutter vertical rail : 47.62 mm x 44.45 mm x 1.35 mm thick (iii) Frame top and sides :- 63.50 mm x 38.10 mmx 1.31 mm thick (20027)
S & F three track aluminium sliding window double leaf glazed shutter and single leaf mosquito proof shutter each in single frame work) without sash bars with approved make of following extruded section of anodised glazed shutter as per Standard Engineering practices including necessary jointing cleats, glazing clips, rubber packing snap beading, screws, handle and locking arrangement etc, 4 mm thick sheet glass, tinted quality on panel and stainless steel wire cloth for mosquito proofing, 0.36 mm nominal dia and average width of aperture 1.40 mm fixed with alumininum screws and tacks complete all as specified and as directed. (Refer Jindal Cat M-2014 ) Aluminium sections : 'A' series (i) Shutter bottom & top :- 37.50 x 15 x 1.3 mm thick (20690) (ii) Shutter interlock :- 37.50 x 23 x 1.3 mm thick (20689) (iii) Shutter side (Handle) :- 37.50 x 23 x 1.3 mm thick (20689) (iv) Frame bottom :- 75 x 26 x 1 mm thick (20671) (v) Frame top and sides :- 75 x 26 x 1 mm thick (20672)
S&F in repairs, mild steel rolling shutters with 1mm thickness of laths, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; push pull or manual type all as specified and as directed.
Taking down rolling shutter of any type including cover, anchoring rod, manual/ gear operated type with gear box and crank handle etc repairs to defective components/replacement such as pulling system to gear system, gear box, locking plate, guide channel, bracelet plate etc, reassembling the whole rolling shutter including greasing complete, welding, drilling where required and refixing the shutter after rectification in the same opening complete area of each shutter n exc 10 sqm each complete all as directed. (Items required to be replaced shall be paid separately under respective item of schedule 'a' as supply only. The items to be replaced / repaired has to be decided by the Engineer in Charge.)
Taking down rolling shutter of any type including cover, anchoring rod, manual gear operated type with gear box and crank handle etc repairs to defective components/replacement such as pulling system of gear system, gear box, locking plate, guide channel, bracelet plate etc reassembling the whole rolling shutter including greasing complete, welding, drilling where required and refixing the shutter after rectification in the same opening complete area of each shutter exc 10 sqm but n exc 20 sqm each complete all as specified and as directed. All the shutters shall be removed carefully with accessories without damaging to the adjacent structures. Contractor shall lay out all the defective parts of removed shutters at site and after verification by Engr-in-charge, defective parts shall be replaced with new fixture/items. These fixtures/items/parts shall be paid extra as supply only rates. The contractor shall repair all the repairable defective parts of shutter without any extra cost to the department. All the repaired parts/accessories alongwith new parts/accessories shall be re-assembled and fixed. (Note : Contractor shall carry out necessary greasing, easing etc for functioning of the shutter without any extra cost).
Supply only lath section 1.20 mm thick for shutter width exc 35 m conforming to IS-6248-1979 (section of lath shall have a distance of 75 mm between rolling center) complete all as specified and as directed.
Supply only roller of steel pipe (Shaft) confirming to heavy duty of size 50 mm nominal bore complete all as specified and directed.
Supply only ball bearing of No 6213/6214 complete all as specified and directed
Supply only locking plate made of 3.15 mm thick reinforced with mild steel angle section not less than 35 x 35 x 5 mm size bottom complete all as specified and directed.
Supply only 100 mm dia 450 mm long SWG ‘O’ high tensile spring conforming to relevant IS complete all as specified and directed.
Supply only MS sheet 1.00 mm thick as in hood cover complete all as specified and directed.
Supply only guide channel made of mild steel deep channel section not less than 3.15 mm thick depth of channel 75 mm complete all as specified and as directed.
Supply only mild steel clip suitable for riveting to lath curtain complete all as specified and as directed.
Supply only chain link fencing wire mesh of any size or type complete all as specified and directed.
Fixing only chain link MS galvanised fencing of any size or type including line wires, to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as directed.
S&F in repairs, galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and orovising of galvanised mild steel wire, staples or steel pins, etc. complete all as directed. (each line wire measured)
S&F 0.63mm thick galvanised corrugated mild steel sheeting with two corrugation side lap, fixed with 'L' type or 'J' type or cranked hook bolts, in roofs, walls etc with grade of zinc coating 275gm/sqm complete all as specified and directed
All as per item No 60 above but except sheets. Note : Serviceable sheets obtained from item No 2 shall be reused.
All as per item No 60 above but 0.80 mm thick plain sheets in hips, ridges or valley gutters etc complete all as specified and as directed. Note : Serviceable sheets obtained from item No 2 shall be reused.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of colour as approved by GE, having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of colour as approved by GE, having tensile strength of 550Mpa as in ridge/flasing board of width or girth not less than 610mm complete all as specified and as directed.
M&L for 6mm thick asbestos cement, corrugated sheets in roof, wall etc, fixed with 'L' type or 'J' type or cranked hook bolts complete all as specified and as directed.
M&L for asbestos cement two piece adjustable serrated ridge for corrugated or semi corrugated sheets fixed with 'L' type or 'J' type or cranked hook bolts complete all as specified and directed.
M & L for water proofing treatment to RCC roof slab, including parapet comprising with the following of treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish n exceeding 100 mtr distance from starting point. (ii) Screed bed or bedding layer of cement mortar 10 mm thick in CM 1:4 with mixing of water proofing compound @3% weight of cement or as per manufacturers instructions and surface finished fair and smooth without using extra cement after applying a coat of cement slurry @ 3 kg/sqm. (iii) Cleaning of plastered roof surface and applying one coat of bituminous primer @ 0.25 ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be applied over bituminous primer as specified above over by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) applying two coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm.
S&F in repairs, suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board ) in a grid of GI system duly suspended with 4mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid complete all as specified and as directed.
M&L for 100mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base for path/paving/hard standing/floor etc. complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed.
M&L for 100mm thick PCC 1:2:4, type B2 (using 40mm graded stone aggregate) as in path/paving/hard standing and finishing the surfaces even and smooth without using exra cement complete all as specified and directed.
M&L for 40mm thick PCC 1:2:4, type B1 (using 20mm graded stone aggregate) as in floors, finished even and smooth using extra cement complete all as specified and as directed.
M&L for non skid coloured ceramic tiles 7 to 8mm thick, (square/rectangular) area of each tiles exc 0.06 sqm but not exc 0.11 sqm as in floors, set and jointed in cement slurry and pointed in white cement mixed with colour pigment to match colour of tile surfaces over and including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
M & L for coloured non-skid ceramic tiles, 9 to 10 mm thick (Square/rectangular), area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over and including 15 mm thick screed bed or bedding layers in cement mortar (1:4) complete all as specified and as directed.
All as per item No.74 above but in vertical surfaces such as skirting and dado, laid over and including 10 mm thick rendering in cement mortar 1:4.
M&L for glazed light coloured/printed ceramic tiles 300x200x7mm/350x250x7 mm /450x350 x7mm thick in vertical surfaces such as skirting, dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 20 to 25 mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab laid over and including 20 mm thick screed in cement mortar (1:4) including rubbing and polishing complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed base and jointed with grey cement slurry mixed with pigment to match the shade of the slab fixed over and including 10mm thick screed bed in CM 1:4 including rubbing, polishing and treating the surface with beeswax polish etc complete all as directed.
S&F in repairs, pre polished chequered cement concrete tiles in floor, area of each tile exc 0.06 Sqm but not exc 0.11 Sqm, 25 mm thick with white cement and pigments of approved make jointed with cement slurry and pointed with white cement mixed with colour pigment to match with the tiles over and including screed bed of 20 mm thick cement mortar (1:4) complete all as specified and as directed.
S&F in repairs, 60 mm thick machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 M-35 Grade over and including 30 mm thick sand bed complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound to be measured and paid separately as "Supply only".
M&L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Supply only approved integral water proofing compound.
M&L for preparation of new plastered surface of walls and applying three coats of white wash complete all as specified and as directed
M&L for preparation of old plastered surfaces of wall and applying one coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surface of walls and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
M&L for preparation of old decorated plastered or unplastered surfaces of ceiling and applying one coat of white wash complete all as specified and as directed.
M&L for preparation of old plastered surface of wall and applying one coat of cement base paint complete all as specified and as directed
M&L for preparation of old decorated wall surface and applying one coat of weather proof acrylic emulsion paint (Apex) complete all as specified and as directed.
Hacking out old broken glass (any thickness, quality or description) from wooden/steel frame or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as directed.
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty or beads, in square n exc 0.5 sqm in each pane complete all as specified and directed.
S&F 3mm thick figured glass, pin head type and glazing with oil putty or beads, in square n exc 0.5 sqm in each pane complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials , new or old, of any description and girth, not otrherwise described and treated with two coat of creosote oil complete all as specified and as directed.
M&L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed.
M&L for preparation of old wood or wood based surface of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paints complete all as specified and as directed.
M&L for preparation of new and previously un-treated steel surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old steel surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old steel surface over 10 cm width or girth and applying two coats of aluminium paint complete all as specified and directed.
S&F in repairs, bib tap, 15mm dia, cast copper alloy, chromium plated, fancy type with crutch or butter-fly handles screwed down for iron pipe or for brass ferrule complete all as specified and as directed.
S&F in repairs, GI tubing, 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repairs, GI tubing, 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F in repairs, 500 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and as directed.
M/S MANOJ PAUL
KAMAKHYA CONSTRUCTION & BUILDERS
M/S PRADYUT ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .