| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹8.7 L+₹1.0 L (13.2%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L2 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
11 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineer NB Kochi
Commander Works Engineer NB Kochi Kataribagh Naval Base PO Kochi 682 004
REPAIR AND MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY SUCH AS HT 11 KV VCB, TRANSFORMERS AND ALLIED HT EM WORKS AT KAVARATTI ANDROTH AND MINICOY UNDER GE NAVY LAKSHADWEEP
2023_MES_618209_2
81103
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
LAKSHADWEEP
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (NAVY) LAKSHADWEEP
₹18,000
Yes
16 Dec 2023
17 Oct 2023
13 Nov 2023
17 Oct 2023
11 Nov 2023
24 Oct 2023
Amount
Repairs and servicing of HT 11 KV VCB of current rating upto 630Amps capacity type by drawing out breaker assembly from panel and carry out the following work :- (i) Cleaning/ decarbonising of all fixed and moving contacts, levers, springs using suitable cleaning agent and tightening of screws, nuts, bolts, spring etc, (ii) Adjust the trolley in and out mechanism (iii) Lubricating/greasing of all operating mechanism and moving parts, switching & tripping mechanism, automatic shuttering system, necessary brazing, turning, polishing of main and auxiliary contact, demoisturing of insulators, etc to be done (iv) Checking all end terminals, tighting the nut bolt and washers, replace the unserviceable nut, bolt & washers, draw-in the breaker, put in position, engage the VCB with the supply system and testing for smooth functioning complete all as specified and directed by Engineer in charge. Note 1 :- Cost of unserviceable spare parts such as charging motor, EFR, Aux relays, Vertical connection adapter, Fixed/Moving contacts, Battery backup etc. will be measured and paid under respective items. Note 2 :- Primary/Secondary injection Test Kit and Insulation testing equipment shall be arranged by the contractor and rate deemed to be included the unit rate. Make: M/s Siemens India Ltd / Shneider/ABB.
Supply and Fix in replacement Earth fault relay suitable HT 11 KV VCB including taking down old unserviceable one complete all as specified and directed by Engineer in charge.
Supply and Fix in replacement Auxilary relays suitable for existing make HT11 KV VCB including taking down old unserviceable one complete all as specified and directed by Engineer in charge.
Supply and Fix in replacement of vacuum interrupters 11KV with all fittings suitable for existing makes and testing complete all as specified and directed by Engineer in charge.
Supply and Fix in replacement of current transformer 5/5 A suitable for existing makes and testing complete all as specified and directed by Engineer in charge.
Supply and Fix in replacement of Potential Transformer 11KV/110V suitable for existing makes and testing complete all as specified and directed by Engineer in charge.
Supply and Fix Charging motor operates on single Phase 230 V AC,50 Hz power supply for auto charging of HT breaker suitable for existing make HT11 KV VCB including taking down old unserviceable one complete all as specified and directed by Engineer in charge.
Supply and Replacement of unserviceable Battery 12 Volts 150 AH including taking down unservisable battery complete all as specified and directed by Engineer in charge. Make - Exide /Amaron/Standard farukwa/AMCO
Disconnection and removing old unserviceable Power Pack unit providing, installation & commissioning of Power Pack Input 230 V AC, Output 12 V DC suitable for H.T. VCB Panel complete all as specified and directed by Engineer in charge.
Topping up / complete renewal of transformer oil having breakdown strength not less than 60 KV/Min for oil cooled Transformers complete all as specified and directed by Engineer in charge. Make : Power oil/Servo /any ISI make.
Supply and replace the silica gel for transformer of any capacity complete all as specified and directed by Engineer in charge.
Disconnection and removing unserviceable Transformer Tap changer and Supply and Fix new Transformer Tap changer made of Brass/Copper material for regulating LT volage suitable for existing Transformer of capacity 250 KVA complete all as specified and directed by Engineer in charge. Make : Kirlosker /ITE
Disconnection and taking down the Transformer of any capacity from the existing position and transporting to work shop and opening the outer cover, draining out the oil and lifting the core along with winding, finding the faulty /burnout primary and secondary winding and rewinding with fine enameled insulated copper winding of same size/guage, turns keeping in hot air oven till the moisture evoporates, reassembling the transformer parts such as core, winding, outer cover, refilling back the Transformer oil complete and transporting back to its original position and reconnecting the LT/HT cable connections complete all as specified and directed by Engineer in charge.
Material and labour for outdoor type jointing kit heat shrinkable for 11KV grade UG cable end termination suitable for 3 core Aluminium conductor complete along with jointing material all as specified and as directed of size 95 Sqmm complete all as specified and directed by Engineer in charge.
Material and labour for outdoor type jointing kit heat shrinkable for 11KV grade UG cable end termination suitable for 3 core Aluminium conductor complete along with jointing material all as specified and as directed of size 185 Sqmm complete all as specified and directed by Engineer in charge.
Material and labour for indoor type jointing kit heat shrinkable for 11KV grade UG cable end termination suitable for 3 core Aluminium conductor complete along with jointing material all as specified and as directed of size 95 Sqmm complete all as specified and directed by Engineer in charge.
Material and labour for indoor type jointing kit heat shrinkable for 11KV grade UG cable end termination suitable for 3 core Aluminium conductor complete along with jointing material all as specified and as directed of size 185 Sqmm complete all as specified and directed by Engineer in charge.
Material and labour for outdoor type straight through jointing kit heat shrinkable for 11KV grade UG cable suitable for 3 core Aluminium conductor complete along with jointing material all as specified and as directed of size 185 Sqmm complete all as specified and directed by Engineer in charge.
Material and labour for outdoor type straight through jointing kit heat shrinkable for 11KV grade UG cable suitable for 3 core Aluminium conductor complete along with jointing material all as specified and as directed of size 95 Sqmm complete all as specified and directed by Engineer in charge.
Material and labour for replacement of XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 3 core, 11000 volts, grade of the size 95 Sqmm complete all as specified and directed by Engineer in charge.
Material and labour for replacement of XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 3 core, 11000 volts, grade of the size 185 Sqmm complete all as specified and directed by Engineer in charge.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth for taking out/laying of cable and getting out in any type of soil complete all as specified and directed by the Engineer-in-charge.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and directed
Removing excavated material (Soil) to a distance n exc. 50 m and depositing where directed at a level n exc. 1.5 m above starting point complete all as specified and directed.
Material and labour for sand cushioning with sand in two layer, first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts for cable including consolidation of each layer complete all as specified and directed. Note:- Punned thickness only shall be measured for the purpose of payment.
Supply and laying unreinforced precast concrete cable cover class HV, Type I, flat, size 300x180x40 mm for HT cable all sizes complete all as specified and directed.
Supply and fix in repair of transformer LT side bushing/insulator with neoprene washer with terminal studs and bolt, nuts, etc complete all as specified and directed by Engineer in charge.
Supply and fix in repair of transformer HT side bushing/insulator with neoprene washer with terminal studs and bolt, nuts, etc complete all as specified and directed by Engineer in charge.
Earthing complete with galvanized iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the Galvanised iron earth lead 32x6 mm size, by means nut, bolt, check nuts and washer of galvanized iron and 32x6 mm as earth lead protected by provision of GI light grade pipe 40mm bore incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement CI funnel wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr all as per electrical plate No.3 of SSR Part I and connecting to earth test point all as specified incl testing on completion complete all as specified and directed by Engineer in charge.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and directed by Engineer in charge.
Jack Electrolinks Private Limited
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .