Directorate of Municipal Administration
V B HUNSIGIDAD.
Instalation of decorative light pole in the middle of the road from desai circle to hunnor and rani channamma circle to sa club via forest office and Instalation of HYMAST LIGHT polo ground in jamkhandi town at nagarothana phase 4 project
DMA/2024-25/EL/WORK_INDENT30945
DMA/2024-25/EL/WORK_INDENT30945
Open
Electrical
Two Tender Document System(Two Cover)
DMA District Urban Development Cell Bagalkote
5 documents required · 5 mandatory
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Liquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Executed in any one year (for a continuous period of 12 months) the following minimum quantities of work 1) Excavation-301.01cum, 2) PCC/RCC-81.70cum, 3) TMT-5.19 Tonne 4) LED Street light-195nos
Satisfactory completed, at least one similar Electrical works of value not less than Rs. 77.50 Lakhs as prime contractor (last five years i.e., 2019-20 to 2023-24)
Achieved in at least two financial years a minimum annual financial turnover of Rs . 310.00 Lakhs. (Usually not less than two times the estimated cost under this contract) (last five years i.e., 2019-20 to 2023-24)
liquid assets and or availability of credit facilities of not less than Rs. 46.50 Lakhs (Banker certificate/Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc
₹3,880
₹2.3 L
19 Nov 2024
19 Nov 2024
7 Dec 2024
28 Nov 2024
28 Nov 2024
Instalation of decorative light pole in the middle of the road from desai circle to hunnor and rani channamma circle to sa club via forest office and Instalation of HYMAST LIGHT polo ground in jamkhandi town at nagarothana phase 4 project
Decorative light pole EARTH WORK- 1.1 Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation ...
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushedgraded coarse aggregates and fine aggregates as per relevant ISC...
Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates an...
2.11a Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints...
1.6 Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Supply and laying Double walled corrugated (DWC) HDPE pipe including all necessary conneting sockets/couplings tees/Bends/End-caps of same materials in existing trench as per IS 14930 part-II suitable...
32. 215 32.05 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per ...
31. Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff. LT Cable
31.05 2.5 to 25 Sqmm
286 34.21 Installation of Pre-Insulated Lug - CPTAU for 16 Sqmm
5.42 Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equ...
127 14.03 Wiring for lighting/power circuit using one of FRLS PVC insulted 1.1 kV grade multi strand copper with low conductor resistance 4 Sqmm single core wire in open are concealed system of wiring...
2.5- 2.5.8 3C x 2.5 mm2 Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sh...
5.17 - 5.17.2 40 A SP Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short...
5.17- 5.17.1 6-32 A SP Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Shor...
5.19 Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 5.19.5 63 A 2 pole
5.7. Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 5.7.3 63 A.
Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts
and washers etc.,.) 3-120sec setting.
Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary
bolts, nuts, washers and wiring etc., complete with AC-3 Rating and ...
5.41- 5.41.1 40 x 40 x 6 mm Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then t...
4.3 Electrical SR 2023-24 Supply and erection of 14 Feet Height Street Light Pole 14 Feet Height Street Light Pole on suitable cement concrete foundation with 2.5 Feet height dia 95 mm cast iron decor...
11.8.2 LED Streetlight 40W Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser w...
13.5 Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.
5.20 Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 5.20.1 16-25 A 2 pole
5.40- 5.40.1 100 A 4 x 30 x 6 mm Aluminium Strips Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PV...
442 54.04 Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to e...
HYMAST Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, cau...
Providing and laying in position plain cement concrete for levellingcourse for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS ...
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 ...
Appendix I Additionalities for Formwork, Centering & Scaffolding -Bridges-SI.No.6-Box Culvert 5% (Pg No:116)
Supplying, Fitting and Placing un-coated TMT bar Reinforcement in sub-structure complete as per Drawing and Technical Specifications. Section1600 &2200 (PWD SR 2021-22 Vol-3, P.NO -99, Item No -13.1)
Fabrication, Supplying and Erection Testing and commissioning of12 m/12.5 m long polygon high mast with single /mutiple telescopic sections having (minimum overlap distance of 1.5 times of top sectio...
Supply of 240W LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded po...
Fixing halogen/metal halide floodlight fitting over existing pole /wall celling including clamps bolts and nuts and wiring using suitable capacity wires complete.
Supplying & fixing of Porcelain fuse channel with cut on existing wooden /panel using necessary nuts, bolts and wasgers etc., complete.C) 63Amps
Supplying & fixing and wiring earth electrode for grounding conduits I.C cutouts and other equipments on the meterboard using 40mm dia 2.9mm thick GI pipe 2.5mtr long buried in a pit.The pit should be...
Supplying & running GI/copper conductor for grounding connections, Using necessary fixing materials as required25x3 mm Copper strip
Supplying of 1.1Kv LT UG cable having aluminium conductor PVC insulated, sheated,galvanized steel strip (Except 2CX10Sqmm wire aroured) confiriming to IS -3975:1990(No of strip indicated in GTP N& ex...
Labour charges for laying of 1.1 KV class UG cable in existing trench Gipipe /stoneware pipe /on pole as required I) existing trench/duct.A) 6sqmm to 16 sqmm
Digging of trenche of 0.6m deep x 0.50 Mtr wide refilling the trench to the required ground level and consolidating etc…,complete
HDPE pipes 90MM dia
Supplying fixing and wiring 3phase Digital ammetrt voltmeter
Supplying fixing L.T cast iron pot heads suitable for 1.1 KV class UG cable filled with necessary bitumen /insulating compound complete with terminals, clamps,bolts,nuts,and washersetc...
Fabricating supplying and mounting MS box made out 14 SWG suitable for floor /wall mounting ,fully weather proof with provision for better heat dissipation ,provided with hinged front cover ,equipped ...
Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting.
Supplying and fixing and wiring Eart leatage miniature circuit breaker (ELMAB.,) 240.450V up to 300me sensitivity on existing wood panel board. 32-40 Amps 4 pole
Supplying and fixing Regular MCB distribution Boards on wall /aood Board / flush mounting using require clamps bolts nuts with provision for fixing suitable type capacity MCB SINGLE PHASE/ 3 phase /si...
Supplying and fixing angle iron frame fabricated out of S angle iron and M.S flat with bolt washer etc and painted with 2 coat of red oxide and then two coats of apporved paint 50X50X6mm
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BGK kw-4 30945.doc
Tender Document • 1.69 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .