Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC 28 GREEN PARK PO BELGHARIA KOLKATA WEST BENGAL 700 056 | 24 PARAGANAS NORTH | WEST BENGAL | 700056 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹37.5 L+₹5.2 L (16.2%)Rejected-Finance PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹38.6 L+₹6.3 L (19.7%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹40.9 L+₹8.6 L (26.6%)Rejected-Finance 27 WESTERN STREET ROOM NO 307 KOLKATA 700012 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹43.7 L+₹11.4 L (35.4%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹29.8 L
EMD Value
₹59,600
Closing Date
26 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R and D Chandipur
GE I R and D Chandipur, Post- Chandipur, PIN-756025
CERTAIN BLDG REPAIR TO EM INSTALLATIONS AT RESIDENTIAL AND TECH AREA AND REPAIR TO DOMESTIC SUMMER APPLIANCES AND VOLTAGE STABLIZERS AT PXE CHANDIPUR
2021_MES_417894_1
8607/CDP
Open Tender
Civil Works
Item Rate
180 days
Chandipur
Please refer Tender Documents
6 documents required · 6 mandatory
₹500
Yes
GE I R and D Chandipur
₹59,600
Yes
20 Mar 2021
1 Feb 2021
27 Feb 2021
1 Feb 2021
26 Feb 2021
17 Feb 2021
60 days
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.
PART-I Demolition of cement concrete of any description and in any position not otherwise specifically provided for
M/L for PCC 50 mm thick type C1 1:3:6 (20mm stone aggregate) as in plinth protection, finished even and smooth without using extra cement.
M & L 25 mm thick PCC (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) as in roof paddding complete all as specified
M&L roof treatment using APP based polymeric membrane minimum weight 3.5 kg/sqm and 3 mm thick reinforced with polyster non woven fabric (weight not less than 150 gms/sqm) over a coat of primed and bonding surface by forced application, including taking down old felt complete all as specified and directed by Eng-in-charge.
M&L one coat of aluminium paint 300ml per sqm above the APP membrane felt and all as specified
M&L Rendering 10 mm thick cement plaster in CM 1:4 on roof surface .
Demolition of cement concrete (un reinforced) in floor and paving n exc 15 cm thick (above or below GL) complete all as specified and directed
M/L for PCC 75 mm thick type C2 1:3:6 (40 mm stone aggregate) as in paving, finished even and smooth without using extra cement and making impression whilst concrete is green.
M&L for 15 mm thick screed bed or bedding layer of mortar in CM 1:6 for laying floor finishes for non skid ceramic and grinaite tiles .
M&L for heavy duty vitrified tile not exc 0.16 sqm as in footpath & hard standing set in CM (1:6) includung filling joint with white/coloured cement to match complete all as specified & directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for
M&L precast cover slab 1:2:4,type B1 ( Using 20 mm graded aggregates) as in cover slab for manhole,drain etc and set in cement mortar 1:4.
M&L RCC 1:2:4, type B-1 (using 20 mm graded aggregates) as in chajjas and similar suspended work in any situation.
M&L mild steel TMT bar 10 mm dia and over cut to length bent to shape with MS wire (annealed) not less than 0.90 mm dia complete.
M&L mild steel TMT bar 6 to 8 mm dia cut to length bent to shape with MS wire (annealed) not less than 0.90 mm dia complete.
Form work to chajja, weather shades, cooking platform, shelves incl fair finish surface of the concrete slab.etc
Greasing, tightening, fitting, easing steel rolling shutter without taking down.
Taking down care fully steel rolling shutters of any size complete gear operated/manual operated all as specified and as directed
S&F Steel Rolling shutters, without ball bearing thickness of lath 1.25mm as specified including top cover, anchoring rod, hasp and staple also one shop coat of primer erected in position as indicated, complete push pull or manual type .
Refixing of steel rolling shutters including necessary repairs/replacement of spare parts if required and cleaning dust, greasing etc including making good the disturb surface of brick/ RCC wall in existing all as specified and as directed (spare parts to be paid separately).
M&L Two coats of aluminium paint over a coat of aluminium red oxide primer on steel surfaces including preparation of surfaces over 10 Cm in width or girth complete all as directed by Engineer-in-Charge.
Supply only 75mm wide, 1.25mm thick MS profile for rolling shutter, riveted/welded were necessary including taking out old unserviceable profile one coat of red oxide primer and painting one coat.
S&F in repairs ball bearing for rolling shutter
S&F in repairs safety lever locks MS with 4 lever for rolling shutter.
Supply only MS spring 40 Cm long for rolling shutter for counter balancing the weight of rolling shutter.
S&F in repairs 0.80mm Mild steel, plain, black sheet in wall cladding,steel gates and similar work (like rolling shutter cover hood) cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
Demolition of brick work built in cement mortar incl quoin, arches etc complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6 mtr mean radius, built in CM 1:6.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing ) and rubbish off the premises.
M&L for 15 mm thick screed bed or bedding layer of mortar in CM 1:6 for laying floor finishes for non skid ceramic and grinaite tiles .
M&L Rendering 10 mm thick cement plaster in CM 1:3 on fair faces of brick Work (internal surfaces) for fixing of wall tiling.
M&L Non Skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exc 0.11 sqm in floors etc set & jointed in neat cement slurry and pointed in coloured cement.
M&L Glazed ceramic coloured tiles 300 cm x 200 cm x 6 mm thick white or coloured tiles as in dado, skirting and vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles.
Taking down cement plaster on wall; ceiling, roof etc incl racking out joints hacking for keys, scrubbing with etc complete all as specified and directed
M&L Rendering 10 mm thick cement plaster in CM 1:3 on fair faces ceiling , Chajja, shelves and surface to be even and fair .
M&L Rendering 10 mm thick cement plaster on internal surfaces of brick work in CM 1:6 and surface to be finished even & smooth without using extra cement.
M&L Rendering 15 mm thick cement plaster with WPC @ 3% of wt of cement on external surfaces of brick work in CM 1:4 andn surface to be finished even & smooth without using extra cement. (WPC will be measured and paid separately).
Supply only WPC
M&L Preparation of old plastered surfaces of ceiling and applying one coats of white wash .
M&L Preparation of new plastered surfaces of ceiling and applying three coats of white wash .
M&L Preparation of old plastered surfaces of walls and applying one coats of white wash.
M&L Preparation of new plastered surfaces of walls and applying three coats of white wash.
Complete removal of existing treatment and applying two coat of exterior emulsion on external wall over a coat primer .
Preparation of new plaster surface of wall and apply two coat of exterior emulsion over a coat of primer.
-ditto- all as per item No 1.044 but in over head tank structures exceeding 10 metres height from the average ground level but not exceeding 20 metres height
Dismantling water tanks exc 250 litres and n exc 500 litres.
S&F 500 litre capacity rotational moulded polythylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as per specified in SSR part-I.
S/F PVC ball valves high pressure with polythene float and fly nut complete, screwed for iron pipe of 20mm bore in repair
Disconnecting existing tanks, setting aside (or lowering if required) for repairs,cleaning, etc. and hoisting if required reconnecting and re-fixing in position after Cleaning and removing all scale and dirt from tanks and from mouth of circular pipes etc of tank capacity 500 ltrs
Taking up or down steel water tubing and connecting incl cleaning for refixing or removal to stores for 15 mm bore.
Taking up or down steel water tubing and connecting incl cleaning for refixing or removal to stores for 20 mm bore.
S&F 15 mm dia galvanised steel tubing "medium grade" with all fittings and fixed complete to walls and ceiling or laid in floor as per specification
S&F 20 mm dia galvanised steel tubing "medium grade" with all fittings and fixed complete to walls and ceiling or laid in floor as per specification
Taking down shutter of any description exc 1.00 sqm but n exc 2 sqm complete all as specified and directed.
Taking down shutter of any description n exc 1.00 complete all as specified and directed.
Taking down chowkath or frame exc 1.5 sqm n exc 4 sqm with shutter ( without taking of shutters from frames ) complete all as specified and directed.
Taking down chowkath or frame n exc 1.5 sqm with shutter ( without taking of shutters from frames ) complete all as specified and directed.
M&L Plain cement concrete 1:3:6,type C1 ( Using 20 mm graded aggregates ) in bed blocks for fixing hold fasts etc including necessary form work.
S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, frame rabated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
M/L 30 mm thick glazed and skeleton shutter open rebated and prepared to receive glass auze etc (with sash bar) edges of framing plain using oil putty to securing glass gauge etc compelte all as specified 2nd class hardwood for window & ventilator.
35 mm thick plain framed factory made panalled shutters( two panels) with 12 mm thick veneered particle board with commercial face veneers on both side as panel inserts, styles & rails shall be of second class hard wood timber generally conforming to IS-1003(Part-I) (Door shutters) Kiln seasoned and chemically pressure treated.
Material only for small fitting such as brackets of any type latch and hinge block shaped door and window stops incl all necessary labours articles not exc 200 Cucm of 2nd class hardwood
S/F factory made solid panel PVC door shutter prelaminated one side 30 mm thick(style) conisiting of frame made out of M S tubes for top and bottomrails. MS frame shall be covered with heat moulded plain colour PVC ;C; channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail. Pannelling of plain colour PVC sheet to be fitted ithe MS frame welded/sealed to the stile and rail with suitable PVC sheet bedding and jointed with solvent cement as inrepair
S&F solid PVC door and window frame of size 50 mm x 50 mm made out of 5 mm wood grain sheet reinforced with MS Square tube, suppling & fixing in opening as in repair
S&F 100 mm long aluminium,anodised barrel tower bolts of extruded section.
S&F 150 mm long aluminium,anodised barrel tower bolts of extruded section.
S&F 250 mm long stainless steel sliding door bolts with hasp,staple (bolt type).
S&F 100 mm size mild steel butt hinges medium weight , cold rolled and fixed.
S&F 75 mm size mild steel butt hinges medium weight , cold rolled and fixed.
S&F 50 mm size mild steel butt hinges medium weight , cold rolled and fixed.
S&F 125 mm size alumunium handle, cast type, anodised.
S&F 100 mm size alumunium handle, cast type, anodised.
Refix MS framed guard bar for window or ventilator confo to Fe-410-0 or Fe 310-0 including taking down old.
M&L MS flat iron for hold fast and similar item conforming to Fe-290-0.
S/F sheet glass ordinary quality and glazing with oil putty not exe 0.5 sqm in each pane 3mm thick
M&L Preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer.
Preparation of old wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint .
All as per item No. 1.077 here-in-before but small articles such as hold fasts etc area n.exc. 0.1 sq.mtr each including sanding tarred surfaces.
Preparation of old steel surfaces of any description over 10 cm width and girth and applying two coats of synthetic enamel paint over one coat of red oxide primer.
S&F 15 dia fancy type chromium plated Bib tap cast copper alloy with crutch or butterfly handle fixed in repair .
S&F fancy type chromium plated stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle 15mm bore.
S&F PVC grating doom 100 mm dia .
S/F PVC connection pipe 15mm size with PTMT nuts 450mm long
S/F PVC (SWR & RWP) floor trap plain with grating inclu. Jointing with solvent cement of out let dia 75mm.
M&L for vitreous china squatting pan of Orissa pattern size 580 X 440 mm white with intregal foot rest (excluding flushing cystern and flush pipe) in repairs .
.M&LPVC valve less syphonic action type flushing cistern 10 ltr capacity low levelhigh level white with inlet ball valve , float flush pipe and handle including bracket fixed in repair.
Dismantling of MS fencing post of any section embedded in concrete including taking out embedded portion and making good disturbed ground complete all as directed.
Dismantling fencing wire mesh any type
Excavation in post holes (or similar holes) in soft soil each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with eath around, in layers n.exc 25cm , watering, and removing surplus soil to a distance n.exc 50m and making good surface
PCC 1:4:8 type D-2 using 40 mm graded broken stone aggregate as in foundation for concrete post/strut.
M&L MS work as in fencing posts & struts on top of wall including cutting top to shape as directed, drilling holes, notching for wire etc including all necessary drilling bolting or riveting etc and similar work quality conforming to Fe-410 or Fe-310 complete all as shown on drawing and as directed
TMT bar 10mm dia and over cut to length ,bent to shape required including cranking , bending spirally for hooping column hooking ends and binding with mild steel wire (annealed ) not less than 0.9mm dia
S&F Mild screw bolts 12mm dia (machine made) with hexagonal or square heads at one end and screwed the other end to be fitted with washers and one hexagonal or square nut n.exc 5 cm long
MS flat iron of any size conforming to Fe 410-0 or Fe 310-0 cut to required size for fixing chain link fencing with clamp etc complete including drilling holes, applying coat of Red oxide Zinc Chrome Primer.
Fixing only Chain link fencing of any dia galvanised iron wire mesh of any size, made upto into mattress or cages, straining and fixing to Brick post .
Supply MS galvanised Chain link fencing made out of 3.10 mm dia galvanised iron wire of mesh 75 mm x 75 mm size, made upto into mattress or cages, straining and fixing to Brick post.
Framed work as in doors or gates of angle or other section with gusset plates, rails braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and hanging; also fastening and fixing complete.
M&L Applying 2 coats of Synthetic Enamel paint over a coat of Primer Red Oxide on steel surface over 10 cm girth including preparation of surface
PART-II Supply and charging of Refrigerant gas R-22 (Mafron) for Window type/ Split type AC of various capacity after leak test,Make :- Mafron/Floron.
All as per Item No. 1.099 but for R-134a gas for water cooler of any capacity after leak test,Make :- Mafron/Floron.
All as per Item No. 1.099 but for R-410 gas for Split AC of various capacity after leak test,Make :- Mafron/Floron.
S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 2.5 MFD, + 5% for fan motor of water cooler and airconditioners.Make: TIBCON/SARDA/UNIVERSAL
S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 3.0 MFD, + 5% for fan motor of water cooler and airconditioners.Make: TIBCON/SARDA/UNIVERSAL
S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 3.5 MFD, + 5% for fan motor of water cooler and aircondtioners.Make: TIBCON/SARDA/UNIVERSAL
S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 4 MFD, + 5%for fan motor of water cooler and aircondtioners.Make: TIBCON/SARDA/UNIVERSAL
S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 6 MFD, + 5% for window type airconditioners.Make: TIBCON/SARDA/UNIVERSAL
S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 8 MFD,+ 5%, 4 pin for window type airconditioners.Make: TIBCON/SARDA/UNIVERSAL
S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 10 MFD,+ 5%, 4 pin for window type airconditioners.Make: TIBCON/SARDA/UNIVERSAL
S&F, in replacement, burst proof series dual capacitor 230/440 VAC, 50 Hz, 36 MFD, + 5% for Airconditioners.Make: TIBCON/SARDA/UNIVERSAL
S&F, in replacement, burst proof series dual capacitor 230/440 VAC, 50 Hz, 36+6 MFD, + 5%, 7 pin for Airconditioners.Make: TIBCON/SARDA/UNIVERSAL
S&F, in replacement, burst proof series dual capacitor 230/440 VAC, 50 Hz, 45 MFD, + 5%, 4 pin for Airconditioners.Make: TIBCON/SARDA/UNIVERSAL
S&F, in replacement, burst proof series dual capacitor 230/440 VAC, 50 Hz, 50 MFD, + 5%, 7 pin PSC system for Airconditioners.Make: TIBCON/SARDA/UNIVERSAL
S&F, in replacement, burst proof series dual capacitor 230/440 VAC, 50 Hz, 50+6 MFD, + 5%, 7 pin PSC system for Airconditioners.Make: TIBCON/SARDA/UNIVERSAL
S&F, in replacement, burst proof series dual capacitor 230/440 VAC, 50 Hz,55 MFD, + 5% for Airconditioners.Make: TIBCON/SARDA/UNIVERSAL
Supply and replacement of Single phase Power contactor ,25 Amps,50Hz , 230 volts for Split Ac of 2TR capacity with taking down old one.Make:L&T /Legrand/HPL)
Supply and replacement of PTMT float valve of 15mm size suitable for water cooler of cap 40/80 ltr/hr, 60/120 ltrs/hr and 80/150 ltrs/hr capacity including taking down old float valve. (Make : PRAYAG or equivalent as approved by GE..
Supply and replacement of printed circuit board (PCB) with display board,sensor and remote control for WTAC of 1.5 TR capacity all as per existing type and make including taking down. (Make of existing AC : LG / Voltas).
Supply and replacement of printed circuit board (PCB) for indoor units of Split type AC of 1.5 TR capacity with display board, sensor and remote control including taking down all as per existing type.(Make of existing AC : LG/VOLTAS/SIDWAL/ VIDEOCON).
Supply and replacement of printed circuit board (PCB) for indoor units of Split type AC of 2 TR capacity with display board, sensor and remote control including taking down all as per existing type.(Make of existing AC : LG/SIDWAL/VOLTAS/INVERATOR MODEL).
Supply and fix, in replacement, Fin and Tubes type air cooled condenser Unit for WTAC/STAC of capacity 1.5/2.0 TR with copper tubing of size 1/4" as per sample. (Make : Carrier/LG/Videocon/Voltas).
S&F, in replacement, polystyrene soft thermocol, clear and rather brittle quality required at site during installation of window type air conditioners of size : 180 cm x 90 cm x 40 mm.
S&F, in replacement, Brass Liquid line service value suitable for Split type AC condensing unit of size 1/4"dia of any make and type of STAC all as specified and directed.
S&F, in replacement, Suction line service value suitable for Split type AC condensing unit of size 5/8"of any make and type of STAC all as specified and directed.
S&F, in replacement, fan blade assembly made of aluminium alloy complete for out door unit of split type AC.(Make of AC : LG/ Camipro/ Sidwal)
S&F, in replacement, PVC fan blade suitable for water cooler of any capacity and size.
S&F, in replacement, PVC fan blade suitable for any make of window type air conditioners of cap 1 TR to 2 TR as required and directed.
S&F, in replacement, PVC blower suitable for any make of window type air conditioners of cap 1 TR to 2 TR as required and directed.
S&F, in replacement, PVC connection adaptor pipe of 15 mm dia for Water cooler. (Make : Prayag or equivalent as approved by GE)
S&F, in replacement, Thermostat of 20 Amps capacity for 1.5/2.0 TR WTAC compressor including knob for thermostat. (Make : Annapurna / Indfos)
Supply and replacement of thermostat any capacity or any type for water cooler compressor including knob for thermostat as per sample including taking down. (Make :Annapurna / Indfos)
Supply and replacement of over load relay for water cooler of 40/80, 60/120, 80/150 Ltrs/hrs including taking down. (Make : SRIRAM/ MICROTECH/ ANNAPURNA)
Supply and replacement of synthetic thermal insulation pipe with binding tape of 3/8" dia suitable for suction copper pipe of Window / Split type AC complete all as directed including taking out old deterioted pipe and burried in ground.
All as per Sl Item 1.133 but of dia 5/8" suitable for discharge/liquid line of Window / Split type AC.
All as per Sl Item 1.133 but of dia 1/2" suitable for discharge/liquid line of Window / Split type AC.
Supply and Replacement of internal wirings with single core FRLSH, copper conductor of size 1.5 sq.mm with taking down of old unserviceable wirings of WTAC/STAC.
Supply and Replacement of internal wirings with single core FRLSH copper conductor of sizes 2.5 sq.mm with taking down of old unserviceable wirings of WTAC/STAC.
Supply and Replacement of elect cable of size 2.5 sqmm 3-core FR copper conductor circular type with taking down of old unserviceable incoming cables of WTAC/STAC.
S&F PVC Drain pipe of dia 3/4" suitable for Split type AC including taking down old deterioted pipe and burried in ground.
S&F Non-return valve with dead cap suitable for 1/4" dia charging pipe.
S&F corrugated PVC flexible drain pipe of out let of water cooler, size 36 mm inner dia of standard length including taking down old deterioted pipe and burried in ground.
Supply & Fix, in replacement, Hose clamps suitable for holding of 36 mm dia pipes.
Supply & Fix, in replacement of Hose clamps suitable for holding of 20 mm dia pipes.
Supply and replacement of Rubber bush suitable for holding of Blower motor of Carrier/Videocon WTAC.
Supply and replacement of Clamp sets for the bush of WTAC of make-Carrier.
Supply and replacement of Clips ( steel ) suitable for holding of Blower motor and fan blade of WTAC of make-Carrier.
Supply and replacement of Rubber bush suitable for holding of condensing fan motor of water cooler of any size and capacity.
Supply and replacement of Clamp sets for the bush of water cooler of any size and capacity.
Supply and replacement of Defrost PVC water drain pipes of size 20 mm dia for split type AC including taking down deterioted pipe and burried in ground.
Dismantling of Air Conditioner ( Window / Split type), Refrigerator, water coolers of any capacity & 'make', opening up for servicing, inspection / examination for serviceability of compressor, fan, motor, relay, overload protectors, capacitors, cleaning the evaporator and condenser with compressed air/ water as required, lubrication of moveable parts, replacement of worn out bolts , screws, rubber gaskets, seals, terminal & link clips, unserviceable wiring, rubber mounting for compressor including all minor spare parts for carrying out servicing including reassembling & testing of AC, Refrigerator & water cooler complete all as directed
Supply and replacement of hermetically sealed Rotary type compressor of 1.5 TR capacity for window type/split type AC of existing make and model with new compressors and assembling testing the same with replacement of necessary drier and capillary tube complete all as directed by Engineer-in-Charge including taking down.(Make : Kirloskar/Hitachi)+E87
All as per Sl Item 1.152 but 2.0 TR Window/Split type Room Air Conditioner compressor including taking down.
All as per Sl Item 1.152 but reciprocating type Window/Split type Room Air Conditioner compressor of 1.5 TR capacity including taking down.
All as per Sl Item 1.152 but reciprocating type Window/Split type Room Air Conditioner compressor of 2.0 TR capacity including taking down.
Supply and replacement of compressor for water cooler 40/80 Ltr capacity and assembling and testing the compressor unit complete including taking down all as directed and specified.(Make : DANFOS/ LG/ Kirloskar
All as per Sl Item 1.156 but for water cooler 80/150 Ltr capacity including taking down. (Make : DANFOS/ LG/ Kirloskar
Supply and Replace hermetically sealed reciprocating type compressor for Refrigerator/Deep Freeze 170 to 300 Ltr capacity including taking down. (Make : DANFOS/INDFOS/ LG/KIRLOSKAR)
Repair to worn out body of WTAC/STAC of any make & capacity by replacing worn out portion by providing new CRCA flat sheet / MS angle or strip of appropriate gauge as per existing and fabricated to the shape as required including necessary welding, filling of putty, grinding to make the jointed surface even and apply two coats of synthetic paint over one coat of red oxide all as directed and specified including taking down.
Repair to body of water cooler by providing MS sheet 2 mm thick including welding, replacement of wornout nuts & bolts and repair/fabrication of the compressor mounting base as per existing fabrication work including all as directed and specified ( Approx area of MS Sheet 0.75 Sqm) and painted by two coats of synthetic enameled paint of existing cooler over a coat of red oxide primer.
Taking out blower motor of Window type AC of 1.5/2.0 TR capacity from its existing base and dismantling the same and rewinding the burnt out winding with super enameled copper conductor with existing gauge and size of conductor and varnishing all insulating materials including making necessary heat treatment complete all as directed by Engineer-in-charge.
All as per Sl Item 1.161 but of condensing fan motor of split type AC of 1.5/2.0/3.0 TR capacity.
All as per Sl Item 1.161 but for Condensing fan motor of water cooler of 40/80, and 80/150 Ltrs capacity.
Supply and replacement of unserviceable blower motor of WTAC/condensing motor of STAC with new motor suitable for WTAC/STAC of 1.5 TR capacity including taking down old one. (Make: GE/Crompton Greaves or equivalent as approved)
Supply and replacement of unserviceable blower motor of indoor unit of split AC with new blower motor of split type AC including taking down old one. (Make: GE/Crompton Greaves or equivalent as approved)
Dismantling the voltage stabilizer of any capacity (1 to 5 KVA) and make, opening up for inspection/checking serviceability of voltage regulating transformer relays, circuit board, voltmeters, incoming/outgoing connections etc and reassembling the same with dismantled component after replacement of burnt spare parts and internal wiring complete all as directed and specified by Engineer-in-Charge. Note. Replacement of spare parts shall be measured and paid separately under items below :-
Supply only transformer of any capacity between 4 to 5 KVA including taking down.
Supply only transformer of any capacity between 1 to 3 KVA including taking down.
Supply only square/ round type voltmeter of size 2" x 2" for various voltage stabilizers including taking down.
Supply only transformer relay for various capacity of stabilizers including taking down.
Supply only circuit board for various capacity of stabilizer including taking down.
Supply only 3 way connector for voltage stabilizer including traking down
M&L for dismantling of Window type AC of 1.5 / 2.0 TR capacity and painting externally with one coat of synthetic enamel paint of existing shade and approved make after cleaning the surfaces and assembling, testing complete all as directed and specification by Engineer-in-Charge.
Supply and replace push type water tap made of stainless steel chrome plated suitable for 40/80 Ltr capacity water cooler as per existing including taking down.
Replacement of rusted and damaged bracket with new one for holding of WTAC at the rear side as a platform made up of MS angle of size 50 x 50 X6 mm and MS plate of size 50 x 6 mm and grouted on the wall all as directed and specified including painting with two coat of enameled paint over a coat of primer.
Dismantling of Kent/Usha R.O.water purifier , Replacement of unserviceable components such as PCB, all Filters and membrane, Solenoid-valve, UV Lamp and other minor spare parts, refixing of serviceable spare parts and reassembling all as directed and specified.
Dismantling of Aquagard water purifier, segregation of unserviceable & serviceable components, supply & fixing of new spare parts in place of unserviceable items such as PCB, Filter, Carbon, Solenoid-Valve, UV Lamp, photo resistor and other minor spare parts, refixing of serviceable spare parts and re assembling all as directed and specified.
Supply and replacement of RO Water purifier connection pipe of size 1/4" including taking down.
Supply and replacement of RO Water purifier connection pipe of size 3/8" including taking down.
Supply and replacement of RO Water purifier connectrion pipe of size 1/6" including taking down.
RANA ENTERPRISES
M/s R.C REFRIGERATION
ELECTRO COMMERCIAL CO
jlenterprise
CONSTRUCTION AND MAINTENANCE ENGINEERING CORPORATION
PODDAR SALES CORPORATION
Bidder Name
RANA ENTERPRISES
M/s R.C REFRIGERATION
J B NATH AND SON
ELECTRO COMMERCIAL CO
CONSTRUCTION AND MAINTENANCE ENGINEERING CORPORATION
PODDAR SALES CORPORATION
jlenterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .