| 1 | L1₹65.6 LAccepted-AOC | L1 | Accepted-AOC work order awarded | |
| 2 | Rejected-Technical | - | Rejected-Technical not qualified for price bid opening |
Tender Value
₹58 L
EMD Value
₹1.2 L
Closing Date
11 Feb 2020, 3:00 pmClosed
SE (REMC), RVPN, Jaipur
SE (REMC), SLDC building RVPN, Heerapura Jaipur
Supply, Installation, Testing and Commissioning of 2 Nos. of 40 KVA UPS along with all associated accessories complete in all respect for REMC setup in SLDC, Heerapura and Dismantling Shifting Installation Testing and Commissioning of 160 KVA DG Set
2019_RRVPN_173102_1
BN 8415001903
Open Tender
Electrical Works
Turn-key
210 days
SE (REMC), SLDC building RVPN, Heerapura Jaipur
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,950
Yes
As per specification
₹1.2 L
Yes
12 Oct 2020
26 Dec 2019
12 Feb 2020
26 Dec 2019
11 Feb 2020
10 Jan 2020
Complete UPS System alongwith all associated accessories complete in all respect :
40 KVA UPS: 415V, 3Ph, 40KVA, 50Hz, IP-20, Output-40 KVA
80 KVA Bipass transformer: 415V+-10%, 3Ph-4 Wire, 50Hz+-5%, Output transformer rating-80KVA, efficiency 95%, delta star Copper winding.
384V-200AH 2V Stationary Lead acid (Tubular) type Battery Set: Each battery cell 2V-200AH
UPS Spares & Accessories for maintenance of Stationary Lead acid (Tubular) type batteries: MCCB, Fuse, DC Filter Assembly, Input/output AC Filter assembly, Control Board SCR and IGBT
FAT and SAT Procedure for UPS 2x40 KVA and input and output ACDB.
Monitoring work station: Hardware and Software
Phase sequence corrector
Battery Circuit Breakers: Minimum battery voltage-420VDC
Input ACDB: 415V+-10%, 3Ph-4 Wire, 50Hz+-5%, Indoor type Floor mounting, Degree of protection as per IS-13947 IP-20 suitable for 4 Incomers 250A, output 12 Nos. for Lighting 63A and Misc 12 Nos. of 6A.
Output ACDB: 415V+-10%, 3Ph-4 Wire, 50Hz+-5%, Indoor type Floor mounting, Degree of protection as per IS-13947 IP-20. Incomer I & II plus bus coupler and outgoing 10 Nos. 32A and 20 Nos. 63A and 20 Nos. 25A and Misc 60 Nos. 10A(1Ph, 2Wire) .
Unarmoured PVC insulated FRLS copper control cable size 4CX2.5 Sq. mm
4CX120 Sq mm LT XLPE insulated & PVC sheathed Al armoured cable(3 Ph- 4Wire)
4CX32 Sq mm LT PVC insulated & PVC sheathed Copper armoured cable(3 Ph- 4Wire)
Misc item like Lugs, Ferrules, Cable glands, Insulating tape, teflon tape, soap duster, hacksaw blade etc.
Any other item required for successful completion of the works.
Dismantaling, shifting, installation, testing & commissioning and integration of 160 KVA DG Set System from 132 KV GSS, RVPN, MNIT, Jaipur to the identified location at SLDC building, Heerapura, Jaipur.
Description of Work / Item(s)
Complete UPS System alongwith all associated accessories complete in all respect :
40 KVA UPS: 415V, 3Ph, 40KVA, 50Hz, IP-20, Output-40 KVA
80 KVA Bipass transformer: 415V+-10%, 3Ph-4 Wire, 50Hz+-5%, Output transformer rating-80KVA, efficiency 95%, delta star Copper winding
384V-200AH 2V Stationary Lead acid (Tubular) type Battery Set: Each battery cell 2V-200AH
UPS Spares & Accessories for maintenance of Stationary Lead acid (Tubular) type batteries: MCCB, Fuse, DC Filter Assembly, Input/output AC Filter assembly, Control Board SCR and IGBT
FAT and SAT Procedure for UPS 2x40 KVA and input and output ACDB.
Monitoring work station: Hardware and Software
Phase sequence corrector
Battery Circuit Breakers: Minimum battery voltage-420VDC
Input ACDB: 415V+-10%, 3Ph-4 Wire, 50Hz+-5%, Indoor type Floor mounting, Degree of protection as per IS-13947 IP-20 suitable for 4 Incomers 250A, output 12 Nos. for Lighting 63A and Misc 12 Nos. of 6A.
Output ACDB: 415V+-10%, 3Ph-4 Wire, 50Hz+-5%, Indoor type Floor mounting, Degree of protection as per IS-13947 IP-20. Incomer I & II plus bus coupler and outgoing 10 Nos. 32A and 20 Nos. 63A and 20 Nos. 25A and Misc 60 Nos. 10A(1Ph, 2Wire) .
Unarmoured PVC insulated FRLS copper control cable size 4CX2.5 Sq. mm
4CX120 Sq mm LT XLPE insulated & PVC sheathed Al armoured cable(3 Ph- 4Wire)
4CX 32 Sq mm LT PVC insulated & PVC sheathed Copper armoured cable(3 Ph- 4Wire)
Misc item like Lugs, Ferrules, Cable glands, Insulating tape, teflon tape, soap duster, hacksaw blade etc.
Any other item required for successful completion of the works.
Dismantaling, shifting, installation, testing & commissioning and integration of 160 KVA DG Set System from 132 KV GSS, RVPN, MNIT, Jaipur to the identified location at SLDC building, Heerapura, Jaipur.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .