Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹15.4 L+₹39,772 (2.66%)Rejected-Finance H NO 496 SECTOR 10 GURGAON 122001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹16.2 L+₹1.2 L (8.12%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L3 | Rejected-Finance Not the lowest tenderer |
Tender Value
₹26.5 L
EMD Value
₹53,000
Closing Date
15 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
SPL REPAIR TO BLDG NO P 184 P 185 AND P 186 THREE COOK HOUSE OF 11 RAJ RIF AND PROVN OF OPEN RAIN WATER DRAIN NEAR BUILDING NO P 01 P 90 P 19 P 41 P 20 P 57 AND P 60 AT SHANKAR VIHAR UNDER GE SOUTH DELHI CANTT 10
2020_MES_368235_1
GE/DS-112/2019-20
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹53,000
Yes
22 Oct 2020
11 Aug 2020
17 Sept 2020
11 Aug 2020
15 Sept 2020
31 Aug 2020
12 Aug 2020 - 22 Aug 2020
60 days
Amount
Excavation in trenches n.exc 1.5m wide and 1.5 m deep for shafts, wells, manholes or similar items and n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out including forming bottom surface to required level / slope for drains etc in soft/loose soil complete all as specified and directed by Engineer-in-charge
Returning, filling in, incl spreading, levelling, watering and well ramming in layers n.exc 25 cm. In soft/loose soil complete all as specified and directed by Engineer-in-charge
Removing excavated material for a distance exc 5 KM & n.exc 10 KM and depositing out side the Defence premises on descreation of contractor complete all as specified and directed by Engineer-in-charge
PCC 1:4:8 type D-2 (using 40MM graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-charge
M&L brick work with sub class 'B' bricks (old size bricks) straight or curved on plan exc 6 m mean radius built in cm 1 : 4 with and including weep holes in brick work complete all as specified and directed by Engineer-in-charge
M&L rendering 15 mm thick on fair faces of brick work/ concrete surfaces, finishing even and smooth without using extra cement in cement mortar 1:4 complete all as specified and directed by Engineer-in-charge
M&L for precast drain covers RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) with 40mm dia holes made in the cover slabs to drain run off set in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge
M&L for PCC 1:2:4 type B-2 using 40mm graded aggregate in surface channel and drains complete all as specified and directed by Engineer-in-charge
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, incl forms, moulds, mitred/ stopped ends etc complete all as specified and directed by Engineer-in-charge
All same as per item No 09 above but here-in-before add for each 25 mm grith or part thereof over 30 cm.
PCC 1:2:4 type B-1 using 20mm graded aggregate as in coping including necessary form work complete all as specified and directed by Engineer-in-charge
M&L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410 or Fe 310 GDE E-165 complete all as specified and directed by Engineer-in-charge
S&F 10 mm dia and over TMT bars for precast cover slab cut to length, bent to shape & binding with MS wire(annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed by Engineer-in-charge.
All as per item No. 13 above but here-in-before 8 mm dia bars
Taking down unserviceable sub main wiring any type and size and making good the disturbed surface to match the existing surface complete all as specified and directed by Engineer-in-charge.
M&L for submain wiring complete multistrand copper conductor cable 2 runs of 6 Sqmm for phase and neutral and 1 run o 4 sqmm for earth wire drawn through existing concealed PVC conduit in wall not less than 25mm dia with all fittings like tees, bends, junction/terminal boxes etc as per site requirement complete all as specified and directed by Engineer-in-charge. Note :- Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour . Two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length).
Taking down carefully the old u/s Aluminium/ Copper point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, pendants, sockets, regulators, call bell etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete all as specified and directed by Engr-in-Charge. Note:- Temporary powe supply shall be provided by contractor.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable drawn through existing concealed PVC/ MS conduit and including PVC flexible pipe and all assessories complete in walls and in steel terminal boxes suitable for swtches, sockets, fan regulators etc with screw, cup washer and 1.5 sqmm copper eath continuity wire conneced to ceiling rose to fitting and earth dolly complete all as specified and directed . Note : 1. The rate is inclusive cutting/chasing and making good disturbed surface with CM d to disturbed surface of 1:3 and same surface finishes with the adjoining surface of disturbed area with OBD/colourwash/white wash complete all as specified and directed by Engineer-in-charge. 2. In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes.
One light/fan point controlled by one switch.
One switch socket outlet type 5 Pin 6 Amp on same board.
All as per item No. 18 above but here-in-before One switch socket outlet type 5 Pin 6 Amp on independent board.
All as per item No 18 above but here-in-before 2.5 Sqmm cable for phase and neutral and 2.5 sqmm for earthing one switch socket outlet type 5 Pin 16 Amp on independent board.
All as Item No 18 above but here-in-before for one socket outlet 5/15 Amps on Independent board with cables 4.0 sqmm size for phase and neutral and 2.5 Sqmm for earthing including sheet metal enclosure point for Geyser complete all as specified and directed by Engr-in-charge.
S&F in replacement surface mounting tubelight fitting, 1 x 20Watt, 230Volts 4ft LED CRCA batten including retrofit T8 glass (LED tube rod) with and including, internally prewired with all accessories and including connecting uo to fitting, complete all as specified and directed by Engineer-in-charge. Make:- Cat part No TARA MI 20 of C&S or its equivalent as Havelles/Philips
S&F in replacement surface mounting tubelight fitting, 1 x 20Watt, 230Volts 4ft LED CRCA batten including retrofit T8 glass (LED tube rod) with and including, internally prewired with all accessories and including connecting uo to fitting, all as specified and directed by Enfr-in-charge Make:- Cat part No TARA MI 20 of C&S or its equivalent as Havelles/Philips
S&F in replacement of Building security light fitting 30 Watts LED 5000K new powder coated pressure die cast aluminium compact LED Street light suitable for and including pole dia 40mm of bracket duly fixed with clamps, nut, bolts, & washers etc and complete all as specified and directed by Engineer-in-charge. Make C&S Model INDUS E-series or its equivalent as Bajaj/CG/Havelles/Syska.
S&F in replacement of energy saving ceiling fan 1400mm sweep, 5 star rated with copper wound in white colour complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge. Make:- Havells/Cromption Greaves/USHA Note:- Old ceiling fan to be deposited in MES store of AGE E/M.
S&F 4 step type electronic regulators for ceiling fan 1200mm/1400mm sweep, 240V complete all as specified and directed by Engineer-in-charge.
S&F in replacement of metal body exhaust fan 450mm sweep 230V with louver and copper wound including necessary electric connection with Appropriate size of PVC copper wire from ceiling rose/switch board to exhaust fan including fixing of nut-bolts at suitable size and making good the disturb surface of wall with OBD/white wash to match with existing surface complete all as specified and directed by Engineer-in-Charge. Make:- Bajaj/Havells/Cromption Greaves Note- Old exhaust fan to be deposited in MES store yard of AGE E/M.
S&F ceiling rose surface bakelite 65x25mm two to three terminals complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush type 5/6 Amps SP one way complete all as specified and directed by Engineer-in-charge.
S&F socket 2 in 1, 3 pin 5 Amps complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush type single pole one way 15 Amp complete all as specified and directed by Engineer-in-charge.
S&F socket 2 in 1, 3 pin 5& 15 Amps complete all as specified and directed by Engineer-in-charge.
S&F in replacement TPN DB 4 way double door type for fixing MCCB upto 100 Amps as incomer and MCB as out going with metal door and IP 43 protection & connecting complete all as specified and directed by Engineer-in-charge. Make Legrand/ABB/Crabtree.
S&F in replacement SPN DB 8 way double door type with metal door and IP 43 protections flush mounting for MCBs & connecting complete all as specified and directed by Engineer-in-charge. Make:- Legrand/ABB/Crabtree.
S&F in replacement MCB DP 40 Amps 'C' series, breaking capacity 10 KA 'C' curve 240volts , 50 Hz including necessary incoming and outgoing electric connection with suitable size copper lugs etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB SP 5 to 32 Amps 'C' series, breaking capacity 10 KA 'C' curve 240volts , 50 Hz including necessary incoming and outgoing electric connection etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCCB 100 Amps 3 pole 415 volts fixed type with breaking capacity 36KA 415 volts, including necessary incoming and outgoing electric connection with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement concealed double door sheet metal enclosures with socket plug top and 20 Amps MCBs for geyser complete all as specified and directed by Engineer-in-charge.
S&F in replacement of water heater storage type (Geysers) of capacity 50 Ltrs, vertical type, AC Electric 230 volts complete with heating element, thermostate, 3 core lead, plug top, safty valve, including electric and water connection, and fixing suitable size of nut-bolts and washer and making good the disturb surface of wall with OBD/white wash to match the existing surface complete all as specified and directed by Engineer-in-charge. Make:- VENUS / USHA LEXUS /CROMPTON GREAVES /BAJAJ Note:-Old Geyser is to be deposited in MES store yard of AGE E/M.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to GI srip by means of nut, bolts and check nuts and washers, GI all as shown in electrical plate No 3 connected to eathing test point and testing on completion and including test point termination, complete all as specified and directed by Engineer-in-charge. Note: The cost of excavation and earth work, PCC pit and CI cover, funnel & watering pipe, wire mesh, charcoal dust and common salt and 15mm dia medium grade GI pipe as protection to earth lead wire shall be deemed included in the unit rate of earthing.
S&F in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicate distulation for loop earthing etc as required 4mm dia galvanised iron or steel wire complete all as specified and directed by Engineer-in-charge.
Excavating over areas, n. exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-charge.
S&F PVC casing pipe 110mm bore medium grade 6 KG/cm2, ISI marked, plain with bail plug at the bottom of each bore complete all as specified and directed by Engineer-in-charge.
M&L for pea gravel / fine aggregate spread and leveled in trenches / recharging wells complete all as specified and directed by Engineer-in-charge.
M&L for gravel 5 to 10mm size spread and leveled in trenches / wells complete all as specified and directed by Engineer-in-charge.
M&L for loose filling with aggregates of guage 8 to 15cm size spread and leveled in trenches/wells etc complete all as specified and directed by Engineer-in-charge.
M&L for rugs made of mild steel not less than 20mm round bar fixed in recharge pits including applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed by Engineer-in-charge.
S&F reinforced concrete pipes, class NP 2, 300mm bore with one collar per length of pipe fixed in trenches / rechare pits etc for connecting / by pass arrangements complete all as specified and directed by Engineer-in-charge.
M&L for drilling 200 mm dia bore holes by DHT cum rotary method at any depth as in any type of soil maximum upto 40 mtr depth from natural ground level and including removal of surplus soil to a distance n. exc 50 M complete all as specified and directed by Engineer-in-charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
P R Constructions
verma enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .