Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹247.32Accepted-AOC | ₹247.32 Quoted ₹247.40 | L1 | Accepted-AOC LOWEST QUOTED BIDDER |
| 2 | L2₹248.29+₹0.89 (0.36%)Rejected-Finance | ₹248.29+₹0.89 (0.36%) | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 3 | L3₹2.5 Cr+₹2.5 Cr (10060081.1%)Rejected-Finance | ₹2.5 Cr+₹2.5 Cr (10060081.1%) | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 4 | L4₹2.5 Cr+₹2.5 Cr (10273919.0%)Rejected-Finance | ₹2.5 Cr+₹2.5 Cr (10273919.0%) | L4 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 5 | L5₹2.6 Cr+₹2.6 Cr (10456591.6%)Rejected-Finance | ₹2.6 Cr+₹2.6 Cr (10456591.6%) | L5 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹2.7 Cr
EMD Value
₹3.5 L
Closing Date
24 Mar 2023, 10:00 amClosed
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD BOWENPALLY POST SECUNDERABAD 500011
PROVISION OF MULTIPURPOSE SHED , BRIEFING ROOM AND CYCLE SHED IN RESPECT OF WORK SERVICES FOR ALTERNATIVE VENUE FOR PARADE GROUND AT AFA HYDERABAD
2023_MES_575404_2
86700/E8
Open Tender
Civil Works
Item Rate
180 days
GE AFA HYDERABAD
AS PER NIT
9 documents required · 9 mandatory
₹2,000
GE AFA HYDERABAD
₹3.5 L
Yes
27 Mar 2023
3 Mar 2023
25 Mar 2023
3 Mar 2023
24 Mar 2023
17 Mar 2023
3 Mar 2023 - 13 Mar 2023
Amount
SCHEDULE 'A' PART - I (B/R PORTION) :- Taking down shutters including frame of any description not exc 1.0 sqm each complete all as specified and as directed.
Taking down shutters including frame of any description exc 1.0 sqm but not exc 2.0 sqm each complete all as specified and as directed.
Demolition of plain cement concrete (unreinforced) of any description and in any position and removing demolshed material up to 5.0 KM and depositing where directed complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position and removing demolshed material up to 5.0 KM and depositing where directed complete all as specified and as directed.
Demolition of PCC block masonry with cement mortar of any description and in any position and removing demolshed material , debris and rubbish up to 5.0 KM and depositing where directed complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors , aprons etc laid bedded and pointed in any mortar and removing demolshed material , debris and rubbish up to 5.0 KM and depositing where directed complete all as specified and as directed.
Taking up or down steel tubing including fittings 25 mm or 32 mm dia complete all as specified and as directed.
Taking up or down steel tubing including fittings 20 mm dia complete all as specified and as directed.
Taking down PVC flush tanks of any description complete all as specified and as directed.
Taking down EWC of any description complete all as specified and as directed.
Taking down wash hand basin of any description complete all as specified and as directed.
Taking down 15 mm bore bib tap of any description complete all as specified and as directed.
Taking down 15 mm bore pillar tap of any description complete all as specified and as directed.
Taking down toilet paper holder of any description complete all as specified and as directed.
Taking down15 mm bore angle cock of any description complete all as specified and as directed.
Taking down existing rotational moulded PVC water storage tanks exc 500 ltrs but not exc 1000 ltrs (cylindrical , vertical with closed top) of any description complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard / dense soil complete all as specified and as directed.
Removing excavated material exc 1.5 Km and not exc 5.0 Km and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and as directed.
Grubbing up tree trunk of girth exc 250 cm and not exc 300 cm including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance not exc. 50 mtr and clearing site complete all as specified and as directed.
Excavating in trenches not. exc 1.5 mtr width and not exc 1.5 mtr in depth for foundation or etc or for shafts , wells , cesspits , manholes , pier holes , for laying of cables etc n exc 10 sqm on plan and not exc 1.5 mtr in depth and getting out in hard / dense soil, complete all as specified and as directed.
Excavating in trenches not. exc 1.5 mtr width and exc 1.5 mtr but not exc 3.0 mtr in depth for foundation or etc or for shafts , wells , cesspits , manholes , pier holes etc n exc 10 sqm on plan and exc 1.5 mtr but not exc 3.0 mtr in depth and getting out in haard / dense soil, complete all as specified and as directed.
Returning filling in ,including spreading ,levelling,watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and as directed.
M & L for cement concrete 1:4:8 as in foundations, filling and mass concrete type D-2 mix using 40 mm graded stone aggregate, completed all as specified and as directed.
M & L for Reinforced Cement Concrete (Design Mix M-25), as in foundations, including rafts, footings, foundation beams, plinth beams, basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed.
M&L for Formwork to sides of concrete foundations, footing, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical ot to batter, of rough finished flat surface of concrete, complete all as specified and as directed.
S&F mild steel TMT bars 10 mm dia. and over, cut to length , bent to shape as required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. complete all as specified and as directed.
S&F mild steel TMT bars 6 mm to 8 mm dia. and over, cut to length , bent to shape as required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. complete all as specified and as directed.
S&F mild steel TMT bar 5 mm dia and over upto and including 10 mm dia as in stirrups , spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. complete all as specified and as directed.
M & L for Providing Reinforced Cement Concrete (Design Mix M-25), as in Columns, pillars, piers, posts and struts, complete all as specified and as directed.
M & L for Providing Reinforced Cement Concrete (Design Mix M-25), as in Beams, cantilevers, bressummers, lintels over 1.50m span, complete all as specified and as directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions and similar work, of rough finished surface (Square, rectangular or polygonal) of concrete, complete all as specified and as directed.
M&L for Formwork to sides and soffits of floors or roof beams, beam haunchings, gerders, bressummers, lintels, cantilevers, shalves including supports etc. and similar work, of rough finished flat surface of concrete, complete all as specified and as directed.
M&L for AAC (Autoclaved Aerated Concrete) block masonary, blocks exc 10 cm in width (Block size 600 mm x 200 mm x 200 mm) having compressive strength as per IS-2185 (Part-III) and set in Chemical mortar of LATICRETE or equivalent as per manufacturer directions complete all as specified and as directed. Make : - BIRLA / ULTRATEC / SHREE SHAKTI / PRIME
M & L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement plaster 1:4 and rendering is to be finished even and smooth with out using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of distemper oil emulsion over a coat of primer and over 3 mm thick wall care putty on plastered surfaces complete all as specified and as directed.
M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement plaster 1:4, including finished even and smooth without using extra cement, complete all as specified and as directed.
M&L for applying two coats of Acrylic smooth exterior weather proof paint of required shade @1.67 lit / Sqm over 10 cm width and including a coat of primer applied @2.20 Kg / 10 Sqm including preparation of new plastered surfaces complete all as specified and as directed.
M&L for Anti Termite Treatment , treating the bottom and sides of excavation at the rate of 5 litres of emulsion per sqm of the surface area complete all as specified and as directed.
M&L for Anti Termite Treatment , treating the back fill in contact with foundations at the rate of 7.5 litres of emulsion per sqm of vertical surface area complete all as specified and as directed.
M&L for Anti Termite Treatment , treatingg the top surface of filled earth at the rate of 5 liters of emulsion /Sqm of vertical surfaces complete all as specified and as directed.
M&L for Anti Termite Treatment , treating the soil along with external wall of the building at the rate of 2.5 ltr / RM complete all as specified and as directed.
M & L for Hard core of gauge n exc 63 mm deposited ,spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface, used broken stne or boulders,complete all as specified and as directed.
M & L for 100 mm thick cement concrete 1:4:8 type D-2 mix, (using 40 mm graded stone aggregate ) as in flooring / pavings etc complete all as specified and as directed.
M&L for 75 mm thick PCC (1:2:4) type B-1 mix using 20 mm graded aggregate as in plinth protection finished fair and even etc including joint cutting and filling the joint shall be filled with mastic filling compraising of 01 part of heated bitumen blown grade any penetration and 3 parts of sand (all by Weight) complete all as specified and as directed.
S&F Framed brackets of angles or tee with web and flanges cut to shape ,drilled and countersunk for screw , incuding bending and welding angles, as necessary gusset plates ,rivetting , etc. not exc. 10 Kg each brackets, conforming to Fe-290 Gde E-165, complete all as specified and as directed.
S&F Self Supported structural roofing colour coated Galvalume (aluminum-zinc alloy-coated steel sheets with 55% aluminum, 43.5% zinc and 1.5% silicon coating ) corrugated steel sheet 1.2mm thick (TCT) as in trussless roof in profiles and 20 m span all as per manufacturer instructions using requsite mechanical equipment. Sheet comes in cold roll coils of width 0.914 m including necessary fittings/fixtures & sealing the joints all as per manufacturer instructions. The panel forming and installation is a complete on-site process. The Pre Curved Corrugated Sheet, after launching is fixed at the supporting RCC structure or eave with self-splitting High Tensile Screws or Nuts & Bolts, as per manufacturer instructions and cost is deemed to included in quoted rate.
S&F Self supported structural roofing colour coated Galvalume (aluminum-zinc alloy-coated steel sheets with 55% aluminum, 43.5% zinc and 1.5% silicon coating ) corrugated steel sheet 1.0mm thick (TCT) as in trussless roof in profile and 10 m span all as per manufacturer instructions using requsite mechanical equipment. Sheet comes in cold roll coils of width 0.914m including necessary fittings/fixtures & sealing the joints all as per manufacturer instructions. The panel forming and installation is a complete on-site process. The Pre Curved Corrugated Sheet, after launching is fixed at the supporting RCC structure or eave with self-splitting High Tensile Screws or Nuts & Bolts, as per manufacturer instructions and cost is deemed to included in quoted rate.
S & F 2 mm thick Fibre glass reinforced transluscent corrugated sheeting with two corrugation side lap fixed with coach screw and washer in roof and wall etc. complete all as specified and as directed.
S&F stainless steel turbo ventilator wind driven of blade size 5.0 mm thick , ventilator throat diameter 610 mm , and outer dia 750 mm with high sesitive roller bearing system complete all as specified and as directed.
S&F Joist, channel, angle, or tee sections, fixed independently and connected with plates, etc. as in posts, horizontal and inclined bracings, inclined supports etc., confirming to Fe-410 -W (Gde E-250) quality B including necessary welding complete all as specified in drawings and as directed.
M& L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (GdeE- 250) quality B complete all as specified and as directed.
M&L for Preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L 100 mm thick cement concrete M-15 mix (20 mm graded aggregate) as in flooring (Vacum Dewater floor) including finishing mechanical trowel even and smooth with out using extra cement complete all as specified and as directed.
M&L for Forming contraction (Dummy) joints 30 mm x 10 mm wide, filled with epoxy sealing compound complete all as specified and as directed.
M&L for Forming expansion joint 12 mm thick and 100 mm deep filled with pre formed bituminous filler and top 30mm filled with epoxy sealing compound complete all as specified and as directed
S & F Vitrified Ceramic coloured tiles 10 mm thick Light shade, polished area of each tile exc 0.42 sqm but not exc 1.00 Sqm set and jointed in neat cement slurry and pointed in white or coloured cement to match in floors including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed.
S & F Vitrified Ceramic coloured tiles 10 mm thick Light shade, polished area of each tile exc 0.42 sqm but not exc 1.00 Sqm set and jointed in neat cement slurry and pointed in white or coloured cement to match in skirting/dado including screed plaster of mortar 10 mm thick in cement mortar 1:4 complete all as specified and as directed.
S & F GI snap grid frame work for false ceiling system complete all as specified and as directed.
S&F Hangers of any dia G I rods any lenth, with adjustable bolts of suitable dia complete all as specified and as directed.
M & L for suspended false ceiling system using decorative 10 mm thick PVC planks of 300 mm wide, of approved pattern and colour, jointed with interlocking slotted system of tongue and groove edges including connecting beading complete all as per manufacturer instructions complete all as specified and as directed.
S & F 12 mm thick Plywood, grade BWR,type BB as in wall panelling , fillets fixed with screws to ply wood complete all as specified and as directed.
M&L for 0.9 imm thiick Decorative laminate sheet type I, or surface finish, colour and pattern as approved complete all as specified and as directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass / stainless steel screws complete all as per architectural drawings and the directions of Engineer-in-Charge.
S&F, powder coated aluminium frame for doors, windows, ventilators, partitions etc with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F 4.0 mm thick plain glass, and glazing with oil putty or fixed in aluminium sections in squares n exc 0.5 sqm in each pane complete all as specified and as directed.
M&L for plain Cement concrete 1:3:6 type C-2, mix (using 40 mm graded stone aggregate) as in foundations , filling and mass concrete complete all as specified and as directed.
Supply and fixing of 12 mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes and fixing 02 no of SS Handles and floor springs, cleats etc., including etching of Air Force Emblem, lettering on two shutters) including necessary accessories complete all as specified and as directed.
Excavation over area, not exc 1.5 mtr deep and getting out in hard / dense soil complete all as specified and as directed.
Excavation over area, exc 1.5 mtr but not exc 3.0 mtr deep and getting out in hard / dense soil complete all as specified and as directed.
Excavation in post holes (or similar holes) each not exc 0.5 cum getting out in hard/dense soil including removal of excavated material complete all as specified and as directed.
M& L for Plain Cement concrete 1:2:4 Type B-2 mix (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for Machine pressed precast concrete inter locking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade over average thickness of 50 mm sand cushing / filling complete all as specified and as directed.
S&F Rolled steel work in Columns and posts, built up with one beam or channel section with flange plates, bases conforming toFe 410W ( Gde E 250) quality A, including necessary welding complete all as specified and as directed
S&F steel work in tubuler steel sections (Circular/Rectangular/Square) conforming to IS 1161-1971 & 4923-1968 Grade St-240 as in posts,trusses, brackets, rafters, purlin membersetc., including necessary welding complete all as specified and as directed
M&L for Preparation of new steel surfaces of any description not exc10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
S&F pre-painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in ridges/cladding to all, fixed with self tapping screws complete all as specified and as directed.
S&F pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof overing in curved / plain sloped , chajja / cladding to wall etc., fixed with self tapping screws complete all as specified and as directed.
S&F mild steel work as in wind ties to roof complete all as specified and as directed.
S&F mild steel framed work for cycle stand to hold cycles with angle / flat base and MS round bars welded to shape reqd, as in rings for locking the cycles complete all as specified and as directed.
S&F hangers / cleats / hooks suitable for light fittings , false ceiling suspenders or supports , inserted in panel seaming as per manufacturer standard pattern and to take load of minimum 50 kg load each and fixed in roofing bottom complete all as specified and as directed.
SCHEDULE 'A' PART - II (E/M) PORTION :- M & L for Point wiring with 1.5 Sqmm copper conductor unsheathed, multistranded, PVC insulated, single core cable FRLS with earth continuity conductor of 1.5 sqmm PVC insulated copper conductor and including rigid PVC concealed conduit of suitable size but not less than 20mm dia. and all accessories fixed to be consealed in wall & surface of the roof etc., including modular type terminal boxes made out of Galvanised sheet of thickness should be not less than 0.9mm thick for fixing of modular switches, modular fan regulators, modular socket outlet etc along-with suitable modular plate for housing switches, etc complete all as specified and as directed.
Description all as per Ser item No 81 above for one three pin socket 6 Amps plug point independent complete all as specified and as directed .
Description all as per Ser item No 81 above but with 2.5 sqmm copper cable in and including PVC conduit complete all as specified and as directed for 15A socket.
Supply and fix Modular Switch type polycarbonate white 1 way, 6A, 240Volts complete all as specified and as directed.
Supply and fix Modular Switch type polycarbonate white 1 way, 16A, 240Volts complete all as specified and as directed.
Supply and fix Modular Socket outlet polycarbonate white 6A - 2/3 pin 2 module complete all as specified and as directed.
Supply and fix Modular Socket outlet polycarbonate white 16A - 2/3 pin 2 module complete all as specified and as directed.
Supply and Fix 1X36 to 40W high efficiency 2X2 recess mounting LED light fitting with glare free homogeneous illumination including LED driver with all accessories internally pre-wired, connecting up with three core twisted flexible copper conductor cable complete all as specified and as directed.
Supply and Fix 1X18 W high efficiency LED light fitting , 220 volts with glare free homogeneous illumination including LED driver with all accessories internally pre-wired, connecting up with three core twisted flexible copper conductor cable complete all as specified and as directed.
Supply & fix Air Circulator fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting including all necessary fixing arrangements complete all as specified and as directed. Make : - Bajaj -Suprime plus or equivalent in Crompton Greaves / Havells.
Supply and fixing LED flood light 50 watt with polycarbonate optics, pressure die-cast housing along with IP 66 ingress protection, 4 kv in built surge protection, efficacy 110 lm/W including all fixing arrangement for fixing on RCC piller complete all as specified and as directed. Make :- Bajaj category refrence GLEAM F 55L WH SY PC SD V2 or equivalent in Crompton Greaves, Philips
Supply and fixing LED security light 45 watt pressure die-cast housing along with prismatic polycarbonate modular secondary lens optics with IP 66 ingress protection, 4 kv in built surge protection, efficacy 120 lm/W including all fixing arrangement for fixing on RCC piller complete all as specified and as directed. Make :- Bajaj category refrence ENXT P 84L WH CR PC SD or equivalent in Crompton Greaves, Philips
Supply and fix MCCB DB 4 way triple pole vertical type 415 volts 50 Hz AC supply including suitable provision for 4 pole MCCB incomer, fixed to the existing wall (concealed) and making good the disturbed surface of wall with the existing wall complete all as specified and as directed. Make :- Legrand / schneider/ siemens
Supply and fix MCCB DB 6 way triple pole vertical type 415 volts 50 Hz AC supply including suitable provision for 4 pole MCCB incomer, fixed to the existing wall (concealed) and making good the disturbed surface of wall with the existing wall complete all as specified and as directed. Make :- Legrand / schneider/ siemens
S&F MCCB 4 pole 63 Amps, 16KA breaking capacity, 415Volts 3-phase supply complete all as specified and as directed.
S&F MCCB 4 pole 100 Amps, 16KA breaking capacity, 415Volts 3-phase supply complete all as specified and as directed.
Supply and fix MCB DB 8 way SPN DB, 230volts 50 Hz AC supply including fixing to the existing wall (concealed/surface) and making good the disturbed surface of wall with the existing wall complete all as specified and as directed. Make :- Legrand / Schneider/ siemens
Description all as per Ser item No 97 above but MCB DBs SPN 2 Way complete all as specified and as directed.
Supply and fix MCB SPN 32 AMP rating 240V, 10 KA 'C' curve in the MCB DB with connection testing and commissioning complete all as specified and as directed.
Supply and fix MCB SP 240V, 10 KA 'C' curve and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed.
M&L for Sub Main wiring with 2 x 4 Sqmm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit of size 25 mm or higher suitable size with all necessary fittings, concealed in walls/roof/floor duly earthed with 1X4 Sqmm of single core cable but green in colour as continuous earthing wire and connecting to common earth dully complete including taking down old submain wiring complete all as specified and as directed. (NOTE :- 3 runs of 4 sqmm and PVC conduit shall be measured as one unit length)
Material and labour for Sub Main wiring with 2 x 6 Sqmm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit of size 25mm or higher suitable size with all necessary fittings, concealed in walls/roof/floor duly earthed with 1X6 Sqmm of single core cable but green in colour as continuous earthing wire and connecting to common earth dolly complete including taking down old sub main wiring complete all as specified and as directed. (NOTE :- 3 runs of 6 sqmm and PVC conduit shall be measured as one unit length)
Material and labour for Sub Main wiring with 4 x 16 Sqmm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit of size 25mm or higher suitable size with all necessary fittings, concealed in walls/roof/floor duly earthed with 2x16 Sqmm of single core cable but green in colour as continuous earthing wire and connecting to common earth dully complete including taking down old sub main wiring complete all as specified and as directed. (NOTE :- 6 runs of 16 sqmm and PVC conduit shall be measured as one unit length)
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps capacity complete all as specified and as directed.
Supply and fix single phase modular type motor starter 32 A, 240 Volts, 50 Hz for split AC including cover plate and PVC surface box of suitable size complete all as specified and as directed.
S & F security light brackets of GI pipe medium grade 40mm upto 1.5 mtr long bend to shape at 100-120 degree including arrangement of fixing at chanel/anglel with the help of flat iron clamps and suitable nuts and bolts including all material required for fitting, including weiding and drilling hole inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Material & labour for earthing complete with GI earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with 4.0 mm GI wire as earthing lead by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 25mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to test point including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to centre both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , for pit cover including testing on completion complete all as specified and as directed. Note :- After completion of work if desired test result is not obtained the earthing is to be redone without any extra cost to deptt.
Supply and fix smart solar LED street light (all in one) 20 watt inbuilt litium battery (24.2AH, 11.1 V) with solar charging time 5-6 hours, 24 Hrs day autonomy, frp made enclosure with IP 65 protection and sensor, 40 nos of white light emitting diodes. The PV module of mono crystalline with at least 17% efficiency inbuilt integrated solar panel complete all as specified and as directed.
Supply and lay 1100 volts grade LT UG cable XLPE insulated,armoured aluminium conductor laid in trenches/walls/pipes etc of size 2 core 6S qmm complete all as specified and as directed.
M&L for Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and as directed.
Supply, lay / spread in trenches, river sand including cleaning, spreading, levellng, punning for laying / cushioning of cable complete all as specified and as directed.
Removing excavated material/surplus soil not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and as directed.
S&F ceiling rose, three terminal, PVC/polycarbonate, insulated body, ISI marked complete all as specified and as directed
Supply and fixing wiring for circuit/sub main wiring along with 2 x1.5 sqmm +1x1.5 sqmm as earth wire of FR PVC insulated copper conductor, single core cable in surface/recessed in stove enameled PVC conduit of suitable size but not less than 20 mm dia including all accessories and necessary work for fixing like welding screws, clamps etc. on iron channel/angle/wall surface etc all as specified and as directed. (NOTE :- 3 runs of 1.5 sqmm and PVC conduit shall be measured as one unit length)
Supply and fixing Metal flush box 4 module and modulr white cover plate for mounting, switches, sockets, fan regulator etc. including all accessories and necessary work for fixing like welding screws, clamps etc. on iron channel/angle/wall surface etc including painting the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Supply and fixing wiring for circuit / sub main wiring along with 2 x 2.5 sq. mm +1 x 2.5 sq mm as earth wire of FR PVC insulated copper conductor, single core cable in surface/recessed in stove enameled PVC Conduit of suitable size but not less than 20mm dia including all accessories and necessary work for fixing like welding screws, clamps etc. on iron channel / angle / wall surface etc complete all as specified and as directed. (NOTE :- 3 runs of 2.5 sqmm and PVC conduit shall be measured as one unit length)
Supply and fixing Metal flush box 3 module and modulr white cover plate for mounting, switches, sockets, fan regulator etc. including all accessories and necessary work for fixing like welding screws, clamps etc. on iron channel/angle/wall surface etc including painting the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed for 6A/16A switch and socket.
Supply , install , testing and commisioning hi wall split Air Conditioner units of capacity 1.5 TR in door / out door complete with cordless remote control unit and with inbuilt air ioniser and plasma filter to better indoor air quality with minimum 5 star rating complete all as specified and as directed.
S & F voltage stabilizer for automatic operation single phase air cooled indoor type and designed input variation between 130 volts to 300 volts with output voltage stabilizer at 230 volts with accuracy of +/- 2.5 and capacity of stabilizer 4.0 KVA complete all as specified and as directed.
Saiansh Associates
M/s Amit Associates
Dwarka Pershad Radhey Ramanlal
GUTHIKONDA BROTHERS
OM INFRA
Universal refrigeration and Engineering Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .