GARRISON ENGINEER (AF) THOISE 19 FBSU, c/o 56 APO, PIN 937219
REPAIR REPLACEMENT OF UNSERVICEABLE LED TYPE SECURITY LIGHT PERIMETER SECURITY LIGHT HPSV MV TO LED LIGHT FITTING AND OTHER CONNECTED WORK AT AF STN THOISE UNDER GE AF THOISE
2022_MES_541972_1
GEAF/T-22/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GARRISON ENGINEER (AF) THOISE
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF Thoise
₹70,000
Yes
28 Sept 2022
30 Jul 2022
23 Aug 2022
30 Jul 2022
20 Aug 2022
6 Aug 2022
Amount
M&L for in repair / replacement LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection, including LED lamps of 45 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-Charge. Make: Havells/Wipro/Philips/SYSKA/Crompton Greaves
M&L for in repair / replacement LED Flood light made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, Potted driver, IP66 protection, including LED lamps of 70 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-Charge. Make: Havells/Wipro/Philips/SYSKA/Crompton Greaves
M&L for in repair / replacement LED Flood light made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, Potted driver, IP66 protection, including LED lamps of 150 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-Charge. Make: Havells/Wipro/Philips/SYSKA/Crompton Greaves
M&L for in repair / replacement electronic LED driver for LED light fittings, capacity 45 Watt, 50Hz, complete all as specified and directed by Engineer-In-Charge. Make: Havells/Wipro/Philips/SYSKA/Crompton Greaves
M&L for in repair / replacement Supply and erecting in repair, in truly vertical position Steel tubular swaged pole with cast iron base plate finial tapper plug, bolts nuts and screws and specified type 410 SP-31 ( 9 mtr long) in truly vertical position 1.5 m length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30 cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified and as directed by Engr-in-Charge. Note - (i) Excavation and PCC shall be measured and paid separately (ii) Height of Pole may be trim as per user requirement but specification remain unchanged.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed by Engr-In-Charge.
All as per Srl Item No. 6.00 here-in-above but for depth exc 1.5m but n.exc 3.00 m complete all as specified and as directed by Engr-in-Charge.
Removing excavated material (soils) not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed, in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10 (1:3:6), type C-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregate), as in coping of poles including necessary form work, finish even and smooth without using extra cement complete all as specified and as directed by Engineer-In-Charge.
M&L for in repair / replacment XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16.0 Sqmm, 2-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends complete all as specified and as directed by Engineer-In-Charge.
All as per BOQ Srl Item No 13.00 above but of size cross-sectional area 16.0 Sqmm, 4 -core complete all as specified and as directed by Engineer-In-Charge.
All as per BOQ Srl Item No 13.00 above but of size cross-sectional area 185.0 Sqmm, 3.5 -core complete all as specified and as directed by Engineer-In-Charge.
All as per BOQ Srl Item No 13.00 above but of size cross-sectional area 300.0 Sqmm, 3.5 -core complete all as specified and as directed by Engineer-In-Charge.
M&L for PCC cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm laid Flat in trenches over the cable with length 250mm perpendicular to the direction of cable, adjacent/ abutting each other complete all as specified and as directed by Engineer-In-Charge. Note:-Excavation and earth work to be measured and paid for separately
Sand cushioning to protection of underground cables, laid 8 cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Thickness after punning down i.e 18cm shall be measured for payment purpose only.
Replacement of old unserviceable/damaged street light bracket made out of GI pipe 40 mm bore medium grade 1.5 m long bend to shape required fixed to pole / wall with MS clamps made out of 40x5 mm, 50 cm long incl nuts bolts of size 80x12 mm complete all as specified and as directed by Engineer-In-Charge.
S& F in replacement copper conductor cable 2.50 sqmm PVC insulated two core unsheathed and PVC insulated for connection of LED street light fitting from existing source complete all as specified and as directed by Engineer-In-Charge.
M&L for PVC conduit pipe 20mm dia medium grade for passing through wire between terminal box to street light with GI clamp complete all as specified and as directed by Engineer-In-Charge.
M&L for in repair / replacment of MCB SPN 32A C Curve and capacity 16KA with plastic enclosure complete all as specified and as directed by Engineer-In-Charge.
M&L for in repair / replacment fabrication and install street light terminal box outdoor canopy type size 40cm Height x 30 cm width x 12 cm thick size of canopy 30cm x 13 cm complete with locking arrangement, 4 Nos aluminium busbar size 20 x 5mm, 8 Nos nut, bolt, & 8 Nos aluminium cable socket suitable for upto 185 sqmm cable embeded in PCC foundation with 2 Nos angle iron leg 25x25mm 40 cm long as per sample incl taking down complete all as specified and as directed by Engineer-In-Charge.
M&L for providing in repair for earthing complete with copper earth plate electrode 60 x 60 cm x 3.5 mm thick buried dirictly in ground(Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level,connected to and including Copper earth wire 4 mm dia upto 7.5 meter long by means of bolts,nuts check nuts and washers of all galvanised iron or steel all as shown in electrical plate No.5 of SSR Part-1 and connected to test point including necessary excavation/ earth work in any type of soil/rock strata,funnel with wire mesh and watering pipe(GI medium grade) 20mm dia,PCC pit with 50mm thick PCC cover etc. including testing on completion excluding GI protection pipe light grade for earthing lead all as directed at site by Engineer-in-Charge.
M&L for applying two coat of synthetic enemal paint to 9 mtr long steel tubler swaged pole including marking alternate white and black strip painting upto 1.2m height and writing pole no on pole complete all as specified and as directed by Engineer-In-Charge.
M&L for applying two coat of synthetic enamel paint to street light terminal box 40cm hieight x 30cm wide x 12 cm depth including grouting angle with smoke gray paint complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged GI pipe with new GI pipes/ Tubes, 'Light grade', galvanised, 50 mm bore, ISI marked, laid in trenches or fixed to walls/ poles with mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and as directed by Engineer-In-Charge.
S & F in replacement Cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor type termination heat shrinkable joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185-300 sqmm complete all as specified and as directed by Engineer-In-Charge. Make: Denson/ M Seal/ Raychem
S & F in replacement Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete all as specified and as directed by Engineer-In-Charge. Make : Denson/ M Seal/ Raychem
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2 complete all as specified and as directed by Engineer-In-Charge. Make: Schneider cat part No- LV426167 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemens.
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 63 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu and as per IEC 60947-2 complete all as specified and as directed by Engineer-In-Charge. Make: Schneider cat part No- LV426165 or equivalent in in L&T/ Legrand/ ABB/ Merlin Gerin/ Siemens.
M&L for in repair / replacment Change over switch, rating 100 Amps, four poles, 415 Volts, AC, 50 Hz, on load, conforms to IS:13947 (Part-3); IEC:60947-2, side handle, fixing in repairs complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- IHBFFE0100 or equivalent in Indo-Asian/ L&T/ Legrand/ ABB/ Controls and switchgears/ Merlin Gerin/ Schneider/ Siemens.
M&L for in repair / replacment Change over switch, rating 200 Amps, four poles, 415 Volts, AC, 50 Hz, off load, conforms to IS:13947 (Part-3); IEC:60947-2, side handle, fixing in repairs complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- IHBFFE0200 or equivalent in Indo-Asian/ L&T/ Legrand/ Standard/ ABB/ Controls and switchgears/ Merlin Gerin/ Schneider/ Siemens.
M&L for in repair / replacment Mild steel bands, straps, including bolts, if required: clamps for house brackets for mounting street/ security light fittings; ties; hooks for hanging fans;and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed by Engineer-In-Charge.
M&L for in repair / replacment Solar Street Light 'All in One' of system voltage 12 V of 30 Watt with lumen of >125 with MPPT controller , Mono crystalline SPV Module (WP), Li Fi Battery with 2 days Back up including design pole , fabrication , fixation, and embedded in Plain Cement Concrete M-10 (1:3:6), type C-1 (using 20mm graded crushed stone aggregates) up depth as per manufacturer's instruction including two years warranty against defects if any arised complete all as specified and as directed by Engineer-In-Charge. Make Havells Cat Part No LHSTAKU7CBAF030 or Equivalent in Crompton and Philips.
Attending day to day complaints for maintenance and repair of street/ perimeter security light fittings of any type and any specifications or any accessories related to security light fittings of any descriptions, fitted/ fixed on poles, buildings or watching towers of any heights and any location, and re-fixing the same after necessary repairs/ replacement of defective parts including rectifying the same as per directions by concerned JE E/M and Engineer-In-Charge, at various locations, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of T&P, ladder or mechanical lift shall be deemed included in quoted rate. (ii) Supply of spare parts of light fittings shall be measured and paid separately.
Note: The work under subject BoQ (Srl item No. 1.00 to 36.00 ) is meant for maint of senstive security and street light in AF Stn Thoise under GE(AF) Thoise. The work shall be executed on ground on required basis. Contractor shall deploy sufficient resources to keep smooth working of Security and street light in the AF station. Contractor or his representative will daily attend the complaints at E/M complaint cell and in addition any breakdown shall be communicated to contractor or his representative by concerned Engineer-in-charge/JE E/M through phone call, text message, complaint slip and or in writing through site order book or through other means. Non complying of attending breakdown by contractor within 24 hours after notify the complaint, recovery @ Rs 1500/- per day shall be recovered from contractor's payment for each complaint so notified.
darshan kumar gandhi
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .