Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹19.3 L+₹39,813 (2.10%)Rejected-Finance | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder | |
| 3 | L3₹20.2 L+₹1.2 L (6.52%)Rejected-Finance | L3 | Rejected-Finance Rejected being 3rd Lowest Bidder | |
| 4 | L4₹20.5 L+₹1.6 L (8.46%)Rejected-Finance 51 HANUMAN COLONY GALI NO 4 CHAK 5 E CHHOTI SRI GANGANAGAR RAJ | L4 | Rejected-Finance Rejected being 4th Lowest Bidder |
Tender Value
₹22.9 L
EMD Value
₹45,800
Closing Date
4 Jul 2020, 6:00 pmClosed
COMMANDER WORKS ENGINEER, SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR-81 OF 2019-20 SPECIAL REPAIRS OF OR MARRIED ACCOMMODATION BUILDING NO. P-63/01 TO P-63/08 AT MILITARY STATION LALGARH JATTAN
2020_MES_335940_1
CA NO. CWE SGNR - 81 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
LALGARH JATTAN
Class E
Category a(i)
10 documents required · 10 mandatory
₹500
GE LALGARH JATTAN
₹45,800
Yes
27 Aug 2020
6 Jun 2020
7 Jul 2020
6 Jun 2020
4 Jul 2020
20 Jun 2020
Amount
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm in thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specificlly provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick / stone walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engineer-in-Charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engineer-in-Charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engineer-in-Charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engineer-in-Charge.
M&L for glazed ceramic coloured tiles of size 350 X 250 X 7 mm / 450 x 350 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engineer-in-Charge.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid over cement screed base laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as specified and directed by Engineer-in-Charge.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub-base complete all as specified and directed by Engineer-in-Charge.
M&L for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in kerb stones size 300mm x 300mm x 100mm with plain fair faces, including chamfers, weathering, throating etc setting in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for Machined pressed precast concrete interlocking paver block glossy with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade over 50mm thick Fazilka sand cushion complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to chajjas, troughs and similar items including edges , for rough surface of concrete, complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete 1:1.5:3 type A-1 using 20mm graded stone aggregrate in Chajjas complete all as specified and directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid seperately under respective item(s) of BOQ.
S&F for mild steel TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clip complete all as specified and directed by Engineer-in-Charge.
S&F for mild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clip complete all as specified and directed by Engineer-in-Charge.
M&L for rendering, 15 mm thick on brick work or concrete surfaces in cement mortar 1:6 on wall finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering, 10 mm thick on brick work or concrete surfaces in cement mortar 1:4 on ceiling finished even and fair complete all as specified and directed by Engineer-in-Charge.
M&L for two coats of oil bound distemper on newly plastered surfaces of walls paint over 3mm thick wall care putty including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment and two coats of oil bound distemper over 3 mm thick wall care putty on plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for 3 coats of white wash on newly / old plastered surfaces incl preparation etc. complete on wall complete all as specified and directed by Engineer-in-Charge.
M&L for 3 coats of white wash on newly / old plastered surfaces incl preparation etc. complete on ceiling complete all as specified and directed by Engineer-in-Charge.
M&L for two coats of cement base paint on newly / old plastered surfaces incl preparation etc. complete on wall complete all as specified and directed by Engineer-in-Charge.
M&L for broken brick boulder hard core of gauge, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and directed by Engineer-in-Charge.
M&L for continous brick edging; with fly ash bricks old size bricks, with width equal to the width of the brick; liad dry on end vertically complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. and getting out hard / dense soil complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation, filling & mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with fly ash bricks, old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with fly ash bricks, old size bricks straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B2 using 40mm graded aggregates as in benching / haunchig of manholes including forming channels including necessary formwork etc. complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B1 using 20mm graded aggregates as in coping and the like including weatjeromg.slightly rounded or chamfered angles and throating, as directed including necessary formwork etc. complete all as specified and directed by Engineer-in-Charge.
M&L for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and set cement mortar 1:6 as in cover slabs (for manholes etc,) chajjas, shelves and similar articles with plain faces complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 10mm thick on fair face of brick work in cement mortar 1:4 and finished surfaces even and smooth with using extra cement as specified including WPC complete all as specified and directed by Engineer-in-Charge. Note : - WPC shall be measured and paid seperately under respective item(s) of BOQ.
M&L for moorum / red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed by Engineer-in-Charge.
Supply and laying DWCPE (SN8) drain pipes 150mm inner dia as per IS-16098 (Part-II), laid in trenches on moorum bed to required slope, including all assessories / fittings, jointing and tested complete all as specified and directed by Engineer-in-Charge. Make :- Rex Polyextrusion Limited/ Dura line / Alom Poly Extrusions Ltd / Jain Irrigation
Returning, filling in, including spreading levelling including watering & well ramming in layers n. exc 25 cm any type of soil all complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n.exc 50m and depositing where direcrted at a level n.exc 1.50 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Cutting into existing manholes for connection of new drain making pipes and rendering cutting out existing benching & forming branch channel in PCC 1:2:4 type B1 smooth finished & forming benches as reqd etc for 150 mm bore complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Dismantling of brick tiles in floor laid dry and pointed in cement morter complete all as specified and directed by Engineer-in-Charge.
Demolition mud in roofs, any thickness, including plastering and leeping complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:7:12) using 40mm graded stone aggregate as filling of sunken floors/bottom and side of drain complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:4 and finished fair and even including mixing of WPC in mortar complete all as specified and directed by Engineer-in-Charge.
Supply only integrated water proofing compound complete all as specified and directed by Engineer-in-Charge. Make:- Dr Fixit / Fosroc / BASF / STP
Material and labour for creating fillet caving 50x50mm with polymer modified mortar on the junction of slab and wall as per manufacture instructions, Material and labour Providing for applying two coats of two component (1 part Liquid: 2 part Powder) ready to use cementitious waterproof coating on properly prepared surface by brush having elongation of >50% for the applying water proofing treatment as per following and complete all as specified and directed by Engineer-in-Charge. (i) Applying 1st coat of two components modified polymer coating on horizontal and verticle surfaces. (ii) Provn of glasses fiber mess of 2x2mm immediately on alone coating. (iii) Applying 2nd coat of two components modified polymer coating after 72hrs on horizontal and verticle surfaces. NOTE:- Complete treatment to be carried out by authorised applicatior of waterproofing manufacture. Make : Dr Fixit / Fosroc / BASF / STP
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm as in roof including cleaning surfaces complete all as specified and directed by Engineer-in-Charge.
M & L for Lime concrete terracing as specified in roof (excluding bitumen tack coat) complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm thick brick tiles laid flat on lime concrete & joints grouted flush in cement mortar (1:3) bedded in 15mm th cement morter (1:6)mixed with 5% of crude oil by weight of cement on lime concrete complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 54 here-in-before but for except tiles complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges including necessary form work etc complete all as specified and directed by Engineer-in-Charge.
M&L for racking out joints/pointing to brick work or brick tiles laid flat in wall to bricks on edges in floors, surface channels, roofs etc. and keyed pointing to bricks walls in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames n.exc 1.5 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames exc 1.5 sq. m but n.exc 4.0 sq. m each with shutters (without taking off shutters from the frame) complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exc 1 Sqm and n.exc 2 Sqm each complete all as specified and directed by Engineer-in-Charge.
S&F for frame work as in chowkats of doors windows of angle iron ,gates or other section with gusset plates, rails, braces etc conforming to Gde Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
S&F for hold fast of flat iron 25 x 3 mm conforming to Fe-290 or Fe 330 including preparing the surfaces & treated with two coats for coaltar & sanded with clean sharp sand complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete 1:3:6 type C–1 (using 20mm graded crushed stone aggregate) as in coping, hold fast, bed blocks or similar block etc complete all as specified and directed by Engineer-in-Charge.
Providing CASEMENT UPVC WINDOW/vent fabricated by approved manufacturer in diferent size of wall thickness 1.2mm + .25 made out of extruded section plain UPVC sections, The window/vent frame made out of Rigid UPVC sections meter cut at 4 Corners & joint with plastic fution welding with internal reinforce require. The Shutter section made out of extruded Rigid UPVC with internal reinforced with provision of 5 MM glaze wire mesh aas per requirement. The Window shall be fixed to the wall using 65 x 100 MM long MS fasterners at suitable place provided for each vertical and horizontal member etc. complete as per manufacturere's complete all as specified and directed by Engineer - in - Charge. Make : Rajshri products and equivalent as approved by GE
Supply and fixing for Fibre glass Reinforced plastic (FRP) door frame of required built in colour in three legged of cross-section 90mm x 45mm having single ribate of 32mm x 15mm to recieve shutter of 30mm thick including laminated door frame moulded with fire retardant grade unsaturated polyster resin and chopped strand mat(CSM) also door frame laminated shall be 2mm thick and shall be filled with suitable wooden block of 2nd class hard wood in all three legs frame shall be covered with fibreglass from all sides MS stay flat iron 25mm x 3mm shall be provided at the bottom to steady the frame complete all as specified and directed by Engineer - in - Charge.
Supply and fixing for 30 mm thick glass fibre reinforced plastic (FRP) paneled doorshutter conferming to IS:14856-2000 of required colour and made with fire retardant grade unsaturated polyster resin,moulded to 3mm thick FRP laminated for forming hollow rails and style with suitable second class hardwood timber block inside at required places for fixing of fittings,cast molithically with 5mm thick FRP laminated for panels including fixing to frames, complete all as specified and directed by Engineer - in - Charge.
S&F for 100 mm long butt hinge, extruded aluminium alloy with galvanised mild steel hinge pin, anosied and fixed type B-21 complete all as specified and directed by Engineer - in - Charge.
S&F for 200 mm long aluminium anodised barrel tower bolt, of extruded complete all as specified and directed by Engineer - in - Charge.
S&F for 150 mm long aluminium anodised handle, cast type complete all as specified and directed by Engineer - in - Charge.
Taking down existing shutter and refixing in same opening shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm each complete all as specified and directed by Engineer - in - Charge. Note:- 'Refixing' includes taking down, easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc.
S&F for 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer - in - Charge.
S&F for 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed by Engineer - in - Charge.
S&F for flush shutter 25mm thick solid core construction with block board core and plywood face panels; commercial type on both sides as cupboard and kitchen shutters complete all as specified and directed by Engineer - in - Charge.
S&F for 100 mm long butt hinge, medium weight, cold rolled mild steel complete all as specified and directed by Engineer - in - Charge.
S&F for 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed by Engineer - in - Charge.
S&F for 300mm long aluminium alloy, anodised, sliding door bolt type not less than 16mm dia fixed complete all as specified and directed by Engineer - in - Charge.
S&F for 300mm ordinary rat tail rod pattern springs including roller and roller plate complete mild steel fixed complete all as specified and directed by Engineer - in - Charge.
M&L for Block board, 19/20mm thick, grade 1 quality, exterior grade, decorative type with decorative face veneer on both face, fixed with screws to timber frame work complete all as specified and directed by Engineer - in - Charge.
M&L for plain fillets, square, rectangular or triangular in section, wrought, secured with nails or brads, sectional area exc 3 & n.exc 6 Sqcm of 2nd class hard wood complete all as specified and directed by Engineer - in - Charge.
S&F for continous (piano) hinges, mild steel, bright finish or electrogalvanised (width of flaps 30mm ) complete all as specified and directed by Engineer - in - Charge.
S&F for 125mm hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engineer - in - Charge.
S&F for 125 mm long aluminium anodised handle, cast type complete all as specified and directed by Engineer - in - Charge.
S&F for stainless steel wire cloth 0.63 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 83 here-in-before but for fixing in repairs complete all as specified and directed by Engineer - in - Charge.
S&F for 4mm thick sheet glass ordinary quality and glazing with oil putty in squares n. exc. 0.5 Sqm in each pane complete all as specified and directed by Engineer - in - Charge.
S&F for 4mm thick figured glass pin head tuype and glazing with oil putty in squares n. exc. 0.5 Sqm in each pane complete all as specified & directed by Engineer-in- charge.
M&L for 12 mm thick Pre-laminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed by Engineer - in - Charge.
S&F for 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of old painted wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint complete all as specified and directed by Engineer - in - Charge.
S&F for drapery rods, coloured, standrad quality, powder coated not less than 25mm dia with heads at both ends and middle support, rings, etc. complete all as specified and directed by Engineer - in - Charge.
S&F in repair brass hat pegs, solid body, 125 mm to 175 mm (4 legs) complete all as specified and directed by Engineer - in - Charge.
S&F in repair towel rails 20mm dia 600mm long brass chromium plated superior quality brass chromium plated fancy type complete all as specified and directed by Engineer - in - Charge.
S&F in repair vitrieous china wash down WC (Pedestal pattern) white and flush pipe including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc., complete all as specified and directed by Engineer - in - Charge.
S&F in repair plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, seat and cover for water closet (European type) complete all as specified and directed by Engineer - in - Charge.
S&F in repairs PVC valve less, syphonic action type flushing cistern,10 ltrs capacity low level, white, with inlet ball valve, float, handle and telescopic pipe and connection to pipe and flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern complete all as specified and directed by Engineer - in - Charge.
S&F in repair vitreous china wash hand basin coloured Flat back of size 550x400mm, long screwed shank fly nut flange end including cutting for and pinning in ends of brackets in 1:3 CM including 32mm dia chromium plated waste coupling / trap complete all as specified and directed by Engineer - in - Charge.
S&F in repairs pillar tap, fancy type, cast copper alloy chromium plated with capston head, screwed down high pressure with or without lettered with long screwed shank and fly nuts, screwed for iron pipe of 15 mm bore complete all as specified and directed by Engineer - in - Charge. Note : Weight not less than 450 gms
S&F in repair bib tap 15mm bore cast copper alloy chromium plated long body fancy type with capston head and cup screwed down, hand operated, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer - in - Charge.
S&F in repair CP brass stop/angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup fixed complete all as specified and directed by Engineer - in - Charge.
S&F in repair CP brass stop valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup (Concealed type) fixed complete all as specified and directed by Engineer - in - Charge. Make : Jaquar cat No- 7053 / Marc / Plumber or equivalent as approved by GE
S&F in repair, shower rose, 125 mm size, brass chromium plated with sweivel joint complete all as specified and directed by Engineer - in - Charge.
S&F for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed by Engineer - in - Charge.
Dismentling of water tanks of capacity exc 500 and n.exc 1000 ltrs and removing from site complete all as specified and directed by Engineer - in - Charge.
S&F for rotational moulded polythene water storage tank 500 ltr capacity of tripple layer vertical with closed top hoisted and fixed in position all as specified in SSR part-I complete all as specified and directed by Engineer - in - Charge.
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore complete all as specified and directed by Engineer - in - Charge.
S&F in repair ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20mm dia bore pipe complete all as specified and directed by Engineer - in - Charge.
Taking down 15 mm dia steel GI tubing including all connected fittings of any dia and in any position including cleaning for re fixing the serviceable pipe complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 109 here-in-before but for 20mm dia pipe complete all as specified and directed by Engineer - in - Charge.
S&F for 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No 111 here-in-before but for 15mm dia pipe fixing only complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No 111 here-in-before but for 20mm dia pipe complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No 111 here-in-before but for 20mm dia pipe fixing only complete all as specified and directed by Engineer - in - Charge.
Dismantling of cast iron pipes, jointed in cement mortar and taking out of trenches if required upto 100mm dia complete all as specified and directed by Engineer - in - Charge.
Dismantling of cast iron pipes, jointed in cement mortar and tabing out of trenches if required 75mm dia complete all as specified and directed by Engineer - in - Charge.
Supply & fixing for 100 mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed to wall with cement joints complete all as specified and directed by Engineer - in - Charge.
Supply & fixing for 75 mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed to wall with cement joints complete all as specified and directed by Engineer - in - Charge.
Fixing only 100 mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed to wall with cement joints complete all as specified and directed by Engineer - in - Charge.
Fixing only 75 mm bore cast iron sand cast soil, waste and vent pipe in any length with or without ears fixed to wall with cement joints complete all as specified and directed by Engineer - in - Charge.
M&L in repairs 75mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate complete all as specified and directed by Engineer - in - Charge.
S&F in repairs branch pieces single (equal or unequal) ordinary or inverted (spring or socket type) or with paralled branch 100mm dia but with oval access door complete all as specified and directed by Engineer - in - Charge.
S&F in repairs branch pieces single (equal or unequal) ordinary or inverted (spring or socket type) or with paralled branch 75mm dia but with oval access door complete all as specified and directed by Engineer - in - Charge.
S&F in repairs 75mm cast iron sanitary connections-short connections pipe of length upto 300mm with socket fixed complete all as specified and directed by Engineer - in - Charge.
S&F in repairs 100mm cast iron sanitary connections-short connections pipe of length upto 300mm with socket fixed complete all as specified and directed by Engineer - in - Charge.
S&F in repairs 75mm bore cast iron bends (any radius) dimining pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and directed by Engineer - in - Charge.
S&F in repairs 100mm bore cast iron bends (any radius) dimining pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and directed by Engineer - in - Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store (measured overalll as fixed along the cente line over fittings and accessories) complete all as specified and directed by Engineer - in - Charge.
S&F for 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed by Engineer - in - Charge.
S&F 110 mm dia PVC (SWR) bend any radius complete all as specified and directed by Engineer - in - Charge.
S&F in repairs 32 mm dia low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors complete all as specified and directed by Engineer - in - Charge.
S&F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed by Engineer - in - Charge.
Sand filling under flooors or in foundation including and consolidation complete all as specified and directed by Engineer-in-Charge.
M & L for brick sub class 'B' locally available best quality laid in trenches above sand consolidted forcable protection complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE PVC insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 16 sqmm 2 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes complete all as specified and directed by Engineer-in-Charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of BOQ.
Taking down carefully copper /aluminium point wiring (light ,fan ,socket or power) complete incl fixture and fitting such as Switches, ceiling roses, pandents, regulators,sockets, light fitting etc removing materials to store for keeping in safe custody for taking credit(credit for above items shuold be made as per conditions separately) and making good distrubed surface of wall ,floors etc. complete all as specified and directed by Engineer-in-Charge.
Taking dwon MCB with sheet metal enclosure, main switch, DB etc and making good disturbed surfaces to match with existing surfaces complete all as specified and directed by Engineer-in-Charge.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge.
M & L point wiring with PVC FRLS insulated unsheathed multistranded copper conductor drawn in and incl of size 1.5 Sqmm, 1100V grade in concealed PVC regid conduit, including provn of of 1.2 mm thich pressed steel sunken terminal boxes 60mm deep,suitable lenthand painted with red oxide primer for mounting switches, sockets, fan regulators covered with and including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 1.5Sqmm PVC insulated stranded copper conductor as earth continuity wire and connected to common earth dolly with copper lugs inserted in including MS boards complete heavy duty for housing switches, sockets, regulators, bell push etc for one light / fan point controlled by one way switch 5 Amps complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 139 here-in-before but for one bell / buzzer point controlled by one way switch 5 Amps complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 139 here-in-before but for one light point controlled by one two way switch 5 Amps
All as per Srl item No. 139 here-in-before but for one 3 pin socket outlet, 5 Amps on the same board with other switches with cable 1.5 Sqmm of size complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 139 here-in-before but for one 3 pin socket outlet, 5 Amps on independent board with other switches, with cable 1.5 Sqmm of size complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 139 here-in-before but for wiring with 4 Sqmm multistandard cable and earth wire with copper conductor of size 4Sqmm for 15 Amps power point complete all as specified and directed by Engineer-in-Charge.
S&F for switch piano, flush type single pole, one way 5 Amps complete all as specified and directed by Engineer-in-Charge.
S&F for switch piano, flush type single pole, one way 15 Amps complete all as specified and directed by Engineer-in-Charge.
S&F for switch piano flush button single pole 2 way 6 Amps complete all as specified and directed by Engineer-in-Charge.
S&F in repairs socket outlet 2 in 1, 3 pin 5 Amps complete all as specified and directed by Engineer-in-Charge.
S&F in repairs socket outlet 2 in 1, 3 pin 5 Amps and 15 Amps complete all as specified and directed by Engineer-in-Charge.
M&L for ceiling rose 3 Pin / PVC / Polycarbonate isolated body complete all as specified and directed by Engineer-in-Charge.
S & F for LED light fittings 1 x 20 w, 230volts integral sleek polycarbonate LED channel with white acrylic cover incl making connection complete all as specified and directed by Engineer-in-Charge. Make : Havells, Cat Part No. LUMILINEBS20WLED830SPCWH or equivalent in Crompton / Syska or as approved by GE.
S & F for lamp holder insulated body with back plate for angle/batten fitting with LED of 09 watt complete all as specified and directed by Engineer-in-Charge.
S & F for bell push fulsh type 6 Amps complete all as specified and directed by Engineer-in-Charge.
S & F for bell AC 230 volts single pole complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required complete all as specified and directed by Engineer-in-Charge.
S & F for sheet metal enclosures for DBs double door type when MCBs to be used single pole & nuteral 8 ways complete all as specified and directed by Engineer-in-Charge.
S&F for MCB SPN 'B' Curve 40 Amps, 240 Volts complete all as specified and directed by Engineer-in-Charge.
S&F for MCB SP 'B' Curve 6 to 40 Amps, 240 Volts complete all as specified and directed by Engineer-in-Charge.
S&F for MCB SP 'B' Curve 32 Amps, 240 Volts complete all as specified and directed by Engineer-in-Charge.
S&F for PVC blanking plate complete all as specified and directed by Engineer-in-Charge.
S & F for LED building security light fitting 25 watt with epoxy powder coated sheet aluminum housing with epoxy powder coated CRCA sheet grey tray, clear acrylic cover and accessories complete incl street light bracket made out of 25mm dia GI pipe medium grade pipe 0.6mtr long complete with 2 set of FI clamps made out of 30mm x 5mm MS flat & nuts, bolts & washers including painting to clamp with two coats of aluminum silver paint over a coat of primer after taking down old unserviceable complete all as specified and directed by Engineer-in-Charge. Make : Bajaj Cat Part No. BRLEP25WLED or equivalent in Crompton / Havells or as approved by GE.
S & F for sheet metal enclusure single pole and nutral with 02 pin and earth plug and socket complete with MCB SP 20 Amps, 240 Volts complete including necessary fixing arrangement and all incoming and outgoing electric connection complete all as specified and directed by Engineer-in-Charge.
Taking dwon LT UG cable of size 16sqmm 2 core complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCB SPN 63 Amps 10 KA complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earht strip 32x6mm thick fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and water pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engineer-in-Charge. Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip upto DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
M & L for taking down old existing tube light fittings and refixings the new tube light fittings in replacement incl all electrical connection, fastners of required size complete all as specified and directed by Engineer-in-Charge.
M & L for taking down old existing switch/socket/ceiling rose/ batton holder and refixing the new accessories in replacement incl all electrical connection complete all as specified and directed by Engineer-in-Charge.
M & L for taking down ceiling/exhaust fan 300m sweep single phase 240 volts 50 Hzs and refixing the same after servicing incl all electric connection, fastners of required size complete all as specified and directed by Engineer-in-Charge. -------------------------------------------------------------------------------------------------------------- Note : A sum of Rs. 66,193.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 38 & 39(R) (Schedule of Credit) of Tender document
ram rattan dass aggarwal
Aggarwal brothers and company
SHIVA CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .