Carrying out part work Incomplete work at Risk and Cost of previous agency for the works of construction of Sewerage and recycled water supply network
NBCC/SBG/IIT/BBSR/2022/30
NBCC/SBG/IIT/BBSR/2022/30
Open Tender-Domestic
Civil Works General
Unknown (Unspecified Location)
₹11,800
₹10.0 L
15 Jun 2022
26 Apr 2022
15 Jun 2022
15 Jun 2022
20 Jun 2022
GRAND TOTAL (DSR+NON DSR) Rs. 48,807,006.17
GRAND TOTAL 42646022.26
GRAND TOTAL 8349419.51
Earth work in excavation by mechanical means (Hydraulic excavator) /
manual means in foundation trenches or drains (not exceeding 1.5 m
in width or 10 sqm on plan), including dressing of sides and ramming
of bottoms, lift upto 1.5 m, including getting out the excavated soil
All kinds of soil
Excavation work by mechanical means (Hydraulic excavator)/ manual
means in foundation trenches or drains (not exceeding 1.5m in width
or 10 sqm on plan), including dressing of sides and ramming of
3 2.9 bottoms, lift upto 1.5 m, including getting out the excavated soil and 0
disposal of surplus excavated soils as directed, within a lead of 50 m.
Hard rock (blasting prohibited)
Excavating trenches of required width for pipes, cables, etc including
excavation for sockets, and dressing of sides, ramming of
bottoms,depth upto 1.5 m, including getting out the excavated soil,
and then returning the soil as required, in layers not exceeding 20 cm
4 2.10 in depth,including consolidating each deposited layer by ramming, 0
watering,etc. and disposing of surplus excavated soil as directed,
within a lead of 50 m :
All kinds of soil
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
Extra for excavating trenches for pipes, cables etc. in all kinds of soil
for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over
5 2.11 corresponding basic item for depth upto 1.5 metre). 0
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600
Excavating trenches of required width for pipes, cables, etc, including
excavation for sockets, depth upto 1.5 m, including getting out the
excavated materials, returning the soil as required in layers not
exceeding 20 cm in depth, including consolidating each deposited
layers by ramming, watering etc., stacking serviceable material for
measurements and disposal of unserviceable material as directed,
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
Hard rock ( blasting prohibited)
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
Extra for excavating trenches for pipes, cables etc. in ordinary/hard
rock exceeding 1.5 m, but not exceeding 3 m. (Rate is over
7 2.14 corresponding basic item for depth upto 1.5 metre).(106% on 0
2.13.1.2)(Pipes, cables etc. exceeding 80 mm dia but not exceeding
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600
b mmdia. Ordinary Rock metre 549.24 0.00 0 0
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
c Hard rock Rock ( Blasting Prohibited) metre 922.94 380.00 350717.2 0
Extra for excavating trenches for pipes, cables, etc. in ordinary/hard
rock exceeding 3m in depth but not exceeding 4.5 m. (Rate is over
corresponding basic item for depth upto 1.5 metre).(264% on 2.13.1.2) 0
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
a Ordinary Rock metre 1188.79 810.00 962919.9 0
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600
b mmdia. Ordinary Rock metre 1367.92 250.00 341980 0
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm
c dia., Hard rock ( blasting prhibited) metre 2298.65 602.00 1383787.3 0
Open timbering in trenches including strutting and shoring complete
(measurements to be taken of the face area timbered):
9 2.20 Depth exceeding 3 m but not exceeding 4.5 m 0
Depth exceeding 3 m but not exceeding 4.5 m
Open timbering in case of shafts, wells, cesspits, manholes and the
like including strutting and shoring complete (Measurements to be
taken of the face area timbered):
Depth exceeding 3 m but not exceeding 4.5 m
Extra rates for quantities of works, executed :
11 2.24.1 In or under water and/or liquid mud, including pumping out water as 0
Depth exceeding 3 m but not exceeding 4.5 m
Depth exceeding 4.5 m but not exceeding 6.0 m meter
Depth exceeding 6.00 m but not exceeding 7.50 m
Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth,
12 2.25 consolidating each deposited layer by ramming and watering, lead up cum 112.40 2160.30 242817.72 0
Extra for every additional lift of 1.5 m or part thereof in excavation /
banking excavated or stacked materials. 0
All kinds of soil
Ordinary or hard rock
Supplying and filling in plinth with Jamuna sand under floors, including
Extra for excavating trenches for pipes, cables, etc. in ordinary/ hard
rock exceeding 4.5 m in depth but not exceeding 6.0 m. (Rate is over
15 NDSR corresponding basic item for depth upto 1.5 metre). 0
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
Hard rock ( blasting prohibited)
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm
Extra for excavating trenches for pipes, cables, etc. in ordinary rock
exceeding 6.0 m in depth but not exceeding 7.5 m. (Rate is over
16 NDSR corresponding basic item for depth upto 1.5 metre). 0
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm
Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
Hard rock ( blasting prohibited)
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm
Extra for excavating trenches for pipes, cables, etc. in hard rock
exceeding 7.5 m in depth but not exceeding 9.0 m. (Rate is over
17 NDSR corresponding basic item for depth upto 1.5 metre). 0
Hard rock ( blasting prohibited)
Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm
TOTAL FOR SUB HEAD - I
Sub Head-II: CONCRETE WORK
Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work up to plinth
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
Providing and laying in position cement concrete of specified grade
excluding the cost of centring and shuttering - All work upto plinth
Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work up to plinth
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm
and shuttering including strutting, propping etc. and
removal of form work for : 0
Columns, piers, abutments, pillars, posts and struts
Extra for providing and mixing water proofing material in cement
concrete work in doses by weight of cement as per manufacturer’s per 50
specification kg cement
TOTAL FOR SUB HEAD - II
Sub Head-III: R C C WORK
Providing and laying in position specified grade of reinforced cement
concrete, excluding the cost of centering, shuttering, finishing and
reinforcement - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
Centering and shuttering including strutting, propping etc. and
removal of form for : Foundations, footings, bases of columns, etc. for
mass concrete. 0
Foundations, footings, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth
and string courses etc.
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Weather shade, Chajjas, corbels etc., including edges.
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand:
4 graded stone aggregate 6 mm nominal size), reinforced with
1.6 mm dia mild steel wire, including centering and shuttering,
roughening cleaning, fixing and finishing in cement mortar 1:3 (1
25 5.18.1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sqm 729.95 2.10 1532.895 0
sills and soffits.
Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars Kg 68.10 109264.00 7440878.4 0
Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete above plinth
Thermo-Mechanically Treated bars
Add for plaster drip course/ groove in plastered surface or moulding
28 5.30 to R.C.C. projections. metre 30.75 21.00 645.75 0
Providing and laying in position machine batched and machine mixed
29 5.33 design mix M-25 grade cement concrete for reinforced cement 0
concrete work, using cement content as per approved design mix,
works up of concrete
to plinth level. to site of laying but excluding the cost
All works above plinth level up to floor V level.
Extra for providing richer mixes at all floor levels.
Providing M-30 grade concrete instead of M-25 grade BMC/RMC.
5.34.1 (Note:- Cement content considered in M-30 is @340 kg/cum). cum 76.50 1049.00 80248.5 0
Add for using extra cement in the items of design mix over and above
31 5.35 the specified cement content therein. quintal 742.75 400.00 297100 0
TOTAL FOR SUB HEAD - III
SUB HEAD - IV: Brick Work
Brick work with modular extruded brunt fly ash clay sewer bricks
32 6.36 (Conforming to IS: 4885 ) in foundation and plinth : 0
Cement mortar 1:4 (1 cement : 4coarse sand)
Providing and laying autoclaved aerated cement blocks masonry with
100mm thick AAC blocks in super structure above plinth level up
to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ) The
rate includes providing and placing in position 2 Nos. 6 mm dia M.S. cum 6386.95 81.00 517342.95 0
bars at every third course of masonry work.
TOTAL FOR SUB HEAD - IV
SUB HEAD - V: Wood Work
Providing and fixing ISI marked flush door shutters conforming to IS :
2202 (Part I) decorative type, core of block board construction with
frame of 1st class hard wood and well matched teak 3 ply veneering
with vertical grains or cross bands and face veneers on both faces of
35 mm thick including ISI marked Stainless Steel butt hinges with
necessary screws
Providing and fixing M.S. grills of required pattern in frames
of windows etc. with M.S. flats, square or round bars etc.
35 9.48.2 including priming coat with approved steel primer all Kg 116.90 853.20 99739.08 0
complete.Fixed to openings/ wooden frames with rawl plugs screws
Providing and fixing bright finished brass hasp and staple (safety type)
36 9.87.1 with necessary screws etc. complete : 150 mm each 106.65 388.00 41380.2 0
Providing and fixing aluminium sliding door bolts, ISI marked anodised
anodic coating not less than grade AC 10 as per IS : 1868), transparent
dyed to required colour or shade, with nuts and screws etc. complete
Providing and fixing aluminium tower bolts, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868 ) transparent
38 9.97.4 or dyed to required colour or shade, with necessary screws etc. each 65.35 52.00 3398.2 0
Providing and fixing aluminium handles, ISI marked, anodised (anodic
coating not less than grade AC 10 as per IS : 1868) transparent or dyed
to required colour or shade, with necessary screws etc. complete : each 69.80 52.00 3629.6 0
TOTAL FOR SUB HEAD - V
SUB HEAD - VI: Steel Work
Structural steel work in single section, fixed with or without
connecting plate, including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer all complete. Kg 67.70 1418.00 95998.6 0
Structural steel work riveted, bolted or welded in built up sections,
trusses and framed work, including cutting, hoisting, fixing in position
a priming coat of approved steel primer all complete.
Supplying and fixing Rolling shutters of approved make, made of
required size M.S. laths, interlocked together through their entire
length and jointed together at the end by end locks, mounted on
specially designed pipe shaft with brackets, side guides and
arrangements for inside and outside locking with push and pull
operation complete, including the cost of providing and fixing
necessary 27.5 cm long wire springs manufactured from high tensile sqm 2142.10 26.00 55694.6 0
steel wire of adequate strength conforming to IS: 4454 – part 1 and
M.S. top cover of required thickness for rolling shutters 80x1.25mm
M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for Rolling shutters
Providing and fixing pressed steel door frames conforming to IS: 4351,
manufactured from commercial mild steel sheet of 1.60 mm thickness,
including hinges, jamb, lock jamb, bead and if required angle
threshold of mild steel angle of section 50x25 mm, or base ties of 1.60
mm, pressed mild steel welded or rigidly fixed together by mechanical
44 10.14 means, including M.S. pressed butt hinges 2.5 mm thick with mortar 0
guards, lock strikeplate and shock absorbers as specified and applying
a coat of approved steel primer after pre-treatment of the surface as
directed by Engineerin-charge:
Fixing with adjustable lugs with split end tail to each jamb
Steel work welded in built up sections/ framed work, including
cutting,hoisting, fixing in position and applying a priming coat of
approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and Kg. 90.10 761.73 68631.873 0
Providing and fixing hand rail of approved size by welding etc. to steel
ladder railing, balcony railing, staircase railing and similar works,
applying priming coat of approved steel primer.
G.I. pipes Railing
TOTAL FOR SUB HEAD - VI
SUB HEAD - VII: Flooring Work
62 mm thick cement concrete flooring with concrete hardener
topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20mm nominal size) and top
layer 12mm thick cement hardener consisting of mix 1:2 (1 cement
hardener mix : 2 graded stone aggregate, 6mm nominal size) by
volume, hardening compound mixed @ 2 litre per 50 kg of cement or
as per manufacture’s specifications. This includes cost of cement
slurry, but excluding the cost of nosing of steps etc. complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and
jointed with grey cement slurry mixed with pigment to match the
shade of the slab, including rubbing and polishing complete with base
of cement mortar 1: 4 (1 cement : 4 coarse sand) :
Providing and fixing on wall face unplasticised Rigid PVC Rain water
pipes conforming to IS : 13592 Type A including jointing with seal ring
49 12.41.2 conforming to IS : 5382 leaving 10 mm gap for thermal expansion. metre 231.65 39.00 9034.35 0
(i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC Rain water pipes conforming to
IS : 13592 Type A including jointing with seal ring conforming to IS :
5382 leaving 10 mm gap for thermal expansion.'Bend 87.5° 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC rain water pipes conforming to
51 12.42.6.2 IS : 13592 Type A including jointing with seal ring conforming to IS : each 295.10 4.00 1180.4 0
5382 leaving 10 mm gap for thermal expansion. 'Shoe (Plain) 110 mm
Providing and fixing unplasticised -PVC pipe clips of approved design
to unplasticised - PVC rain water pipes by means of 50x50x50mm hard
wood plugs, screwed with M.S. screws of required length including
cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse each 189.05 8.00 1512.4 0
sand) and making good the wall etc. complete. 110 mm
TOTAL FOR SUB HEAD - VII
SUB HEAD - VIII: Finishing Work
20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Providing & applying 12 mm thick cement plaster in
54 13.7.1 single coat on fair side of Ceiling Surface with a floating coat of neat sqm 217.15 1190.00 258408.5 0
15 mm cement plaster on the rough side of single or half brick wall of
mix & with floating coat of neat cement slurry.
(I) Cement mortar 1:4 (1 cement : 4 sand)
18 mm cement plaster in two coats under layer 12 mm thick cement
plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick
56 13.12 cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sqm 258.90 626.00 162071.4 0
Extra for providing and mixing water proofing material in cement Per Per bag of 50
bag of plaster work in proportion recommended by the manufacturers. kg cement
White washing on wall & ceiling surface with lime to give an even
shade for new work (three or more coats)
Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade :
59 13.41.1 New work (two or more coats) over and including water tinnable sqm 89.70 130.00 11661 0
priming coat with cement primer
Finishing walls with water proofing cement paint of required shade for
New work (Two or more coats applied @ 3.84 kg/10 sqm)
Finishing walls with Premium Acrylic Smooth exterior paint with
Silicone additives of required shade :
New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and
including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Applying priming coat :
With ready mixed Red oxide zinc chromate primer of approved brand
and manufacture on steel galvanised iron/steel works sqm 27.00 23.00 621 0
Painting with black anti-corrosive bitumastic paint of approved brand
and manufacture to give an even shade : sqm 61.40 57.00 3499.8 0
Two or more coats on new work
Painting with Synthetic enamel paint , having VOC (Volatile Organic
Compound) content less than 150 grams/litres, of approved brand
64 13.84 and manufacture, including applying additional coats wherever 0
required to achieve even shade and colour.
Applying priming coats with primer of approved brand and
having low VOC (Volatile Organic Compound ) content.
With ready mixed pink or grey primer on wood work (hard and soft sqm 36.10 26.00 938.6 0
wood) having VOC content less than 50 grams/ litre
With ready mixed red oxide zinc chromatic on steel / iron works
having VOC content less than 250 grams/ litre
TOTAL FOR SUB HEAD - VIII
SUB HEAD - IX: Dismantling and Demolishing Work
Disposal of building rubbish / malba / similar unserviceable,
dismantled or waste materials by mechanical means, including
loading, transporting, unloading to approved municipal dumping
67 15.60 ground or as approved by Engineer-in-charge, beyond 50 m initial cum 123.70 500.00 61850 0
lead, for all leads including all lifts involved.
TOTAL FOR SUB HEAD - IX
SUB HEAD - X: Road Work
Scarifying metalled (water-bound) road surface including disposal of
rubbish, lead upto 50 m and consolidation of the aggregate received
from scarifying with power road roller of 8 to 10 tonne capacity. sqm 13.75 9800.00 134750 0
Cutting road and making good the same including supply of extra
quantities of materials i.e. aggregate, moorum screening, red bajri and
labour required. 0
bituminous portion
Water bound macadam
Fencing with angle iron post placed at required distance embedded in
cement concrete blocks, every 15th post, last but one end post and
corner post shall be strutted on both sides and end post on one side
only and provided with horizontal lines and two diagonals interwoven
with horizontal wires, of barbed wire weighing 9.38 kg per 100 m
70 16.18 (minimum), between the two posts fitted and fixed with G.I. staples, 0
turn buckles etc. complete.
(Cost of posts, struts, earth work and concrete work to be paid for
separately). Payment to be made per metre cost of total length of
barbed wire used.
With G.I. barbed wire
Construction of granular sub-base by providing close graded Material
conforming to specifications, mixing in a mechanical mix plant at
OMC,carriage of mixed material by tippers to work site, for all leads &
lifts,spreading in uniform layers of specified thickness with motor
71 16.78 grader on prepared surface and compacting with vibratory power 0.00 0 0
roller to achieve the desired density, complete as per
specifications and directions of Engineerin- Charge.
With material conforming to Grade-II (size range 53 mm to 0.075 mm )
TOTAL FOR SUB HEAD - X
SUB HEAD - XI: Aluminium Work
Providing and fixing aluminium work for doors, windows, ventilators
and partitions with extruded built up standard tubular
sections/appropriate Z sections and other sections of approved make
conforming to IS: 733 and IS: 1285, fixing with dash fasteners of
required dia and size, including necessary filling up the gaps at
junctions, i.e. at top, bottom and sides with required EPDM
rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust
72 21.1 free, straight, mitred and jointed mechanically wherever required 0
including cleat angle, Aluminium snap beading for glazing / paneling,
C.P. brass/ stainless steel screws, all complete as per architectural
drawings and the directions of Engineer-in-charge. (Glazing, paneling
and dash fasteners to be paid for separately) :
For fixed portion
Anodised aluminium (anodised transparent or dyed to required shade
21.1.1.1 according to IS: 1868, Minimum anodic coating of grade AC 15) Kg 348.50 380.00 132430 0
For shutters of doors, windows & ventilators including providing and
fixing hinges/ pivots and making provision for fixing of fittings
wherever required including the cost of EPDM rubber / neoprene
gasket required (Fittings shall be paid for separately).
Anodised aluminium (anodised transparent or dyed to required shade
21.1.2.1 according to IS: 1868, Minimum anodic coating of grade AC 15) kg 405.90 260.00 105534 0
Providing and fixing glazing in aluminium door, window, ventilator
shutters and partitions etc. with EPDM rubber / neoprene gasket etc.
complete as per the architectural drawings and the directions of
engineer-in-charge . (Cost of aluminium snap beading shall be paid in 0
With float glass panes of 5.5 mm thickness
Filling the gap in between aluminium frame & adjacent RCC/ Brick/
Stone work by providing weather silicon sealant over backer rod of
approved quality as per architectural drawings and direction of
Engineer-in-charge complete.
Upto 5mm depth and 5 mm width
Providing and fixing stainless steel (SS 304 grade) adjustable
friction windows stays of approved quality with necessary
21.12.1 stainless steel screws etc. to the side hung windows as per direction 0
of Engineer-in-
charge complete.
Providing and fixing aluminium tubular handle bar 32 mm outer
3.0 mm thick & 2100 mm long with SS screws etc .complete as 0
per direction of Engineer-in-Charge.
Anodized (AC 15 ) aluminium tubular handle bar
Providing and fixing 100mm brass locks (best make of approved
quality) for aluminium doors including necessary cutting and
good etc. complete.
TOTAL FOR SUB HEAD - XI
SUB HEAD - XII: Waterproofing Work
Providing and Placing in position suitable PVC water stops conforming
to IS:12200 for construction/ expansion joints between two
RCC members and fixed to the reinforcement with binding wire
pouring concrete etc. complete :
Providing and laying integral cement based water proofing treatment
including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations: a) Applying
a slurry coat of neat cement using 2.75 kg/sqm of cement admixed
with water proofing compound conforming to IS. 2645 and approved
by Engineer-in-charge over the RCC slab including adjoining walls upto
300 mm height including cleaning the surface before treatment. b)
Laying brick bats with mortar using broken bricks/brick bats 25 mm to
115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse
sand) admixed with water proofing compound conforming to IS : 2645
and approved by Engineer-in-charge over 20 mm thick layer of cement
mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water
proofing compound conforming to IS : 2645 and approved by Engineer-
in-charge to required slope and treating similarly the adjoining walls
upto 300 mm height including rounding of junctions of walls and slabs
22.7 c) After two days of proper curing applying a second coat of cement 0.00 0 0 0
slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar
of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-
charge including laying glass fibre cloth of approved quality in top
layer of plaster and finally finishing the surface with trowel with neat
cement slurry and making pattern of 300x300 mm square 3 mm deep.
e) The whole terrace so finished shall be flooded with water for a
minimum period of two weeks for curing and for final test. All above
operations to be done in order and as directed and specified by the
Engineerin-Charge :
With average thickness of 120 mm and minimum thickness at
TOTAL FOR SUB HEAD - XI
SUB HEAD - I: Sanitary Work
Providing and fixing soil, waste and vent pipes :
Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS:
TOTAL FOR SUB HEAD - I
SUB HEAD - II: Water Supply work
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)
pipes, U V stabilized & anti - microbial fusion welded, having thermal
stability for hot & cold water supply, including all PP - R plain & brass
threaded polypropylene random fittings, including trenching, refilling
82 18.6 & testing of joints complete as per direction of Engineer in 0
Charge(External Work)
PN - 16 Pipe, 50 mm OD (SDR - 7.4)
Providing and fixing gun metal gate valve with C.I. wheel of approved
83 18.17 quality 0
C.I/ DUCTILE IRON SPECIALS
84 18.25 Providing and laying S&S C.I. standard specials such as tees, bends, 0
collars, tapers, caps etc. (Heavy class) :
Up to 300 mm dia
C.I/ DUCTILE IRON SPECIALS
Providing and laying flanged C.I. standard specials such as tees, bends,
85 18.26 collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 : 0
Up to 300 mm dia
Providing lead caulked joints to spun iron or C.I. pipes and specials,
86 18.28 including testing of joints but excluding the cost of pig lead : 0
100 mm diameter pipe
150 mm diameter pipe
200 mm diameter pipe
Supplying pig lead at site of work
Providing and fixing C.I. sluice valves (with cap) complete with
bolts, nuts, rubber insertions etc. (the tail pieces if required will
100 MM DIA SLUICE VALVE
Providing and fixing C.I. sluice valves (with cap) complete with
nuts, rubber insertions etc. (the tail pieces if required will be
paid separately) :
150 MM DIA SLUICE VALVE
Providing and fixing C.I. sluice valves (with cap) complete with
bolts, nuts, rubber insertions etc. (the tail pieces if required will
200 MM DIA SLUICE VALVE
Constructing masonry Chamber 60x60x75 cm inside, in brick work
in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with
C.I. surface box 100mm top diameter, 160 mm bottom diameter and
180 mm deep ( inside) with chained lid and RCC top slab 1:2:4
mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm
91 18.33 ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 0
fine sand : 10 graded stone aggregate 40 mm nominal size) and inside
plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm
thick, finished with a floating coat of neat cement complete as
per standard design :
With common burnt clay F.P.S.(non modular) bricks of
Providing and fixing C.I. double acting air valve of approved
92 18.59 quality with bolts, nuts, rubber insertions etc. complete (The tail 0
Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes
conforming to IS : 8329 :. 0
100 mm dia Ductile Iron Class K-9 pipes
150 mm dia Ductile Iron Class K-9 pipes
200 mm dia Ductile Iron Class K-9 pipes
300 mm dia Ductile Iron Class K-9 pipes
Providing and laying Double Flanged (Screwed / Welded) Centrifugally
(Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 :
100 mm dia Ductile Iron Class K-9 pipes
150 mm dia Ductile Iron Class K-9 pipes
300 mm dia Ductile Iron Class K-9 pipes
Providing and fixing C.I. sluice valves (with cap) complete with
bolts, nuts, rubber insertions etc. (the tail pieces if required will
be paid separately) : each 0 2217.04 36 79813.44
63 MM DIA SLUICE VALVE
Providing and fixing C.I. sluice valves (with cap) complete with
bolts, nuts, rubber insertions etc. (the tail pieces if required will
be paid separately) : each 0 3167.20 7 22170.4
90 MM DIA SLUICE VALVE
Providing and fixing C.I. double acting air valve of approved
quality with bolts, nuts, rubber insertions etc. complete (The tail
96 NDSR pieces, tapers etc if required will be paid separately) : each 0 23036.28 1.00 23036.28
TOTAL FOR SUB HEAD - II
SUB HEAD - III: Drainage work
Constructing brick masonry circular type manhole 0.91 m internal dia
at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement
:4 coarse sand), in side cement plaster 12 mm thick with cement
mortar 1:3 (1 cement : 3 coarse sand) finished with a floating
coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3
97 19.9 coarse sand : 6 graded stone aggregate 40 mm nominal size), and 0
making necessary channel in cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size) finished
with a floating coat of neat cement, all complete as per standard
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade
esignation) 560 mm internal diameter conforming to I.S. 12592, total
weight of cover and frame to be not less than 182 kg., fixed in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20
mm nominal size) including centering, shuttering all complete.
(Excavation, foot rests and 12mm thick cement plaster at the external
surface shall be
paid for separately) :
With Sewer bricks conforming to IS : 4885
Extra depth for circular type manhole 0.91m internal dia (at bottom)
With Sewer bricks conforming IS : 4885
Constructing brick masonry circular manhole 1.22 m internal dia
at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement
:4 coarse sand) inside cement plaster 12 mm thick with cement
mortar 1:3 (1 cement : 3 coarse sand) finished with a floating
coat of neat cement foundation concrete 1:3:6 (1 cement : 3
coarse sand : 6 graded stone aggregate 40 mm nominal size) and
making necessary channel in cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size) finished
with a floating coat of neat cement, all complete as per standard
1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade
designation) 560 mm internal diameter conforming to I.S. 12592, total
weight of cover and frame to be not less than 182 kg. fixed in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20
mm nominal size) including centering, shuttering all complete.
(Excavation, foot rests and 12 mm thick cement plaster at the external
surface shall be
paid for separately) :
With Sewer bricks conforming IS : 4885
With Sewer bricks conforming IS : 4885
Extra depth for circular type manhole 1.22 m internal dia (at bottom)
beyond 1.68 m to 2.29 m : 0
With Sewer bricks conforming IS : 4885
Constructing brick masonry circular manhole 1.52 m internal dia
at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement
: 4 coarse sand) inside cement plaster 12 mm thick with cement
mortar 1:3 (1 cement : 3 coarse sand) finished with a floating
coat of neat cement, foundation concrete 1:3:6 (1 cement : 3
coarse sand : 6
graded stone aggregate 40 mm nominal size) and making
2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade
esignation) 560 mm internal diameter conforming to I.S. 12592, total
weight of cover and frame to be not less than 182 kg. fixed in cement
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20
mm nominal size) including centering, shuttering all complete.
19.13.1 (Excavation, foot rests and 12 mm thick cement plaster at the external 0
surface shall be
paid for separately) :
With Sewer bricks conforming IS : 4885
With Sewer bricks conforming IS : 4885
Extra depth for circular type manhole 1.52 m internal dia (at bottom)
With Sewer bricks conforming IS : 4885
With Sewer bricks conforming IS : 4885
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement
: 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement :
2 coarse sand : 4 graded stone aggregate 20 mm nominal
size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8
graded stone aggregate 40 mm nominal size), inside plastering 12
mm thick with cement mortar 1:3 (1 cement : 3 coarse sand)
finished with floating coat of neat cement and making channels in
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) finished with a floating coat of neat
cement complete as per standard design :
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame
(heavy duty) 560 mm internal diameter, total weight of cover and
19.7.3 frame to be not less than 208 kg (weight of cover 108 kg and weight of 0
frame 100 kg) :
With Sewer bricks conforming to IS : 4885
Extra for depth for manholes
With Sewer bricks conforming to IS : 4885
Providing sand cast iron drop connection externally for 60 cm drop
from branch sewer line to main sewer manhole including inspection
and cleaning eye with chain and lid, sand cast iron drop pipe and bend
encased allround with cement concrete 1:5:10 (1 cement : 5 fine sand
: 10 graded stone aggregate 40 mm nominal size) with all centering
and shuttering required, cutting holes in walls and making good with
brick work in cement mortar 1:4 (1 cement : 4 coarse sand) plastered
with cement mortar 1:3 (1 cement : 3 coarse sand) on inside of the
manhole wall, lead caulked joints between sand cast iron pipes and
fittings, stiff cement mortar 1:1 (1 cement : 1 fine sand) joints
between sand cast iron tee and S.W. pipe, making required channels
complete as per standard design and specifications :
150 mm dia sand cast iron drop connection
Extra for depths beyond 60 cm of sand cast iron drop connection
For 150 mm dia sand cast iron drop connection
Providing M.S. foot rests including fixing in manholes with 20x20x10
107 19.15 cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded 0
aggregate 20 mm nominal size) as per standard design :
With 20x20 mm square bar
Supplying and fixing C.I. cover without frame for manholes :
455 x 610 mm rectangular C.I. cover (light duty) the weight of the
cover to be not less than 23 kg
Providing and fixing in position pre-cast R.C.C. manhole cover and
109 19.19 frame of required shape and approved quality 19.19.3 EHD- 35. 0
Circular shape 560 mm internal dia
Constructing brick masonry chamber for underground C.I. inspection
chamber and bends with bricks in cement mortar 1:4 (1 cement : 4
coarse sand) C.I. cover with frame (light duty) 455x610 mm internal
dimensions, total weight of cover with frame to be not less than 38 kg
(weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with
1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10
110 19.30 graded stone aggregate 40 mm nominal size), inside plastering 12 mm 0
thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished
smooth with a floating coat of neat cement on walls and bed concrete
etc. complete as per standard design:
Inside dimensions 600x 850 mm and 45 cm deep for pipe line with
three or more inlets : 0
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Extra for depth beyond 45 cm of brick masonry chamber :
For 600x850 mm size
With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C.
pipes including collars/spigot jointed with stiff mixture of cement
mortar in the proportion of 1:2 (1 cement : 2 fine sand) including
testing of joints etc. complete.
200 mm dia RCC Pipe
250 mm dia RCC Pipe
300 mm dia RCC Pipe
350 mm dia RCC Pipe
400 mm dia RCC Pipe
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C.
pipes including collars/spigot jointed with stiff mixture of cement
118 19.35.1 mortar in the proportion of 1:2 (1 cement : 2 fine sand) including metre 1920.50 203.02 389899.91 0
testing of joints etc. complete.
Providing and laying Non Pressure NP-3 class (Heavy duty) R.C.C. pipes
including collars/spigot jointed with stiff mixture of cement mortar in
119 NDSR the proportion of 1:2 (1 cement : 2 fine sand) including testing of metre 0 641.67 59.75 38339.7825
joints etc. complete
250 mm dia RCC pipe
400 mm dia RCC pipe
Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes
including collars/spigot jointed with stiff mixture of cement mortar in
the proportion of 1:2 (1 cement : 2 fine sand) including testing of
joints etc. complete 450 mm dia RCC Pipe
450 mm dia RCC pipe
Providing and supplying in standard length ISI mark high density
Polyethylene H.D.P.E. Pipes suitable for potable water as per
IS specification each 4984/1995 including trenching ,refilling & testing
123 NDSR of joints complete as per direction of Engineer-in-Charge.External metre 0 197.44 2496 492810.24
63 MM DIA HDPE PIPE
Providing and supplying in standard length ISI mark high density
Polyethylene H.D.P.E. Pipes suitable for potable water as per
IS specification each 4984/1995 including trenching ,refilling & testing
of joints complete
124 NDSR as per direction of Engineer-in-Charge.External work 10 Kg/Cm2 metre 0 341.92 2633 900275.36
With Excise Duty
90 MM DIA HDPE PIPE
Suplying,fitting & fixing approved patent vent cowl I.C.I confirming to
TOTAL FOR SUB HEAD - III
SUB HEAD - IV: Pumps and Accessories work
Providing, supplying, erecting, testing and commissioning of
Submersible Centrifugal Pump of 6 HP Capacity and Head -39 m,
Capacity -975 LPM with a bronze impeller, 3 phase 50 cycles, 380-440
volts, A/C supply with all standard tools ( Main switch & starter
of required rating ) as per relevant I.S. codes including set 0 19795.64 4 79182.56
complete as per satisfactionof engineer-in-charge
Providing, supplying, erecting, testing and commissioning of
Submersible Centrifugal Pump of Capacity 3 HP and Head 23 m,
Capacity -306 LPM with a bronze impeller, 3 phase 50 cycles, 380-440
volts, A/C supply with all standard tools ( Main switch & starter
of required rating ) as per relevant I.S. codes. including
foundation etc complete as per satisfactionof engineer-in-charge.
Providing, supplying, erecting, testing and commissioning of
Submersible Centrifugal Pump of 3 HP CapacityHead 23 m, Capacity -
306 LPM with a bronze impeller, 3 phase 50 cycles, 380-440 volts, A/C
supply with all standard tools ( Main switch & starter of required
129 NDSR rating ) as per relevant I.S. codes including foundation etc complete as set 0 15166.66 2 30333.32
per satisfactionof engineer-in-charge.
Providing, supplying, erecting, testing and commissioning of
SewagSubmersible Pump With SS CF8M Impeller, C.I casing , SS316
shaft suitable for 3 phase, 415V, 50 Hz, AC Supply, Submersible motor
having TEFC enclosure with Class F insulation and IP 68 protection.
The pump shall be operated at 1450 RPM.Th scope shall include all
required accesories viz. pump delievry pipe and header pipe including
specials (M.S\Ducctile Iron\HDPE), check valve, sluice valve,pressure
gauge automatic coupling device, guide pipe, chain with shacle,thrust
block flat submersible cable upto starter panel through suitable size
G.I pipe (20 mtr 3 core flat copper conductor, PVC insulated cable for
each pump-motor set) with necessary electrical connection and
130 NDSR electrical control panel with starter as per the specifications including each 0 56538.45 2 113076.9
foundation etc complete as per satisfactionof engineer-in-charge. The
pump set shall be provided along with automatic shut down
arrangement when water level in pumping station will be go down to
the minimum water level (M.W.L)
Casing C.I, SS CF8M Impeller ,Bronze casing wearing ring and bearing
bush, Mechanical seal Sic vs Sic, CS/SS Bearing, SS Shaft with sleeve, SS
strainer and MS motor body.
AVG. FLOW PUMPS
Capacity : 27.78 LPS Head : 11.10 metre.
Motor : 5.59 KW (7.5 HP)
Providing, supplying, erecting, testing and commissioning of
Submersible Pump With SS CF8M Impeller, C.I casing , SS316 shaft
suitable for 3 phase, 415V, 50 Hz, AC Supply, Submersible motor
having TEFC enclosure with Class F insulation and IP 68 protection. The
pump shall be operated at 1450 RPM.Th scope shall include all
required accesories viz. pump delievry pipe and header pipe including
specials (M.S\Ducctile Iron\HDPE), check valve, sluice valve,pressure
gauge automatic coupling device, guide pipe, chain with shacle,thrust
block flat submersible cable upto starter panel through suitable size
G.I pipe (20 mtr 3 core flat copper conductor, PVC insulated cable for
each pump-motor set) with necessary electrical connection and
electrical control panel with starter as per the specifications including
foundation etc complete as per satisfactionof engineer-in-charge. The
pump set shall be provided along with automatic shut down
arrangement when water level in pumping station will be go down to
the minimum water level (M.W.L)
Casing C.I, SS CF8M Impeller ,Bronze casing wearing ring and bearing
Providing Non clog Sewage Submersible Pump With SS CF8M Impeller,
C.I casing , SS316 shaft suitable for 3 phase, 415V, 50 Hz, AC Supply,
Submersible motor having TEFC enclosure with Class F insulation and
IP 68 protection. The pump shall be operated at 1450 RPM.Th scope
shall include all required accesories viz. pump delievry pipe and
header pipe including specials (M.S\Ducctile Iron\HDPE), check valve,
sluice valve,pressure gauge automatic coupling device, guide pipe,
chain with shacle,thrust block flat submersible cable upto starter
panel through suitable size G.I pipe (20 mtr 3 core flat copper
conductor, PVC insulated cable for each pump-motor set) with
necessary electrical connection and electrical control panel with
starter as per the specifications.
The pump set shall be provided along with automatic shut down
arrangement when water level in pumping station will be go down to
the minimum water level (M.W.L)
Casing C.I, SS CF8M Impeller ,Bronze casing wearing ring and bearing
bush, Mechanical seal Sic vs Sic, CS/SS Bearing, SS Shaft with sleeve, SS
strainer and MS motor body.
AVG. FLOW PUMPS
Capacity : 6.94 LPS Head : 11.10 metre.
Motor : 2.23 KW (3 HP)
Providing, supplying, erecting, testing and commissioning of
Submersible Pump With SS CF8M Impeller, C.I casing , SS316 shaft
suitable for 3 phase, 415V, 50 Hz, AC Supply, Submersible motor
having TEFC enclosure with Class F insulation and IP 68 protection. The
pump shall be operated at 1450 RPM.Th scope shall include all
required accesories viz. pump delievry pipe and header pipe including
specials (M.S\Ducctile Iron\HDPE), check valve, sluice valve,pressure
gauge automatic coupling device, guide pipe, chain with shacle,thrust
block flat submersible cable upto starter panel through suitable size
G.I pipe (20 mtr 3 core flat copper conductor, PVC insulated cable for
each pump-motor set) with necessary electrical connection and
electrical control panel with starter as per the specifications including each 0 24499.99 2 48999.98
foundation etc complete as per satisfactionof engineer-in-charge. The
pump set shall be provided along with automatic shut down
arrangement when water level in pumping station will be go down to
the minimum water level (M.W.L)
Casing C.I, SS CF8M Impeller ,Bronze casing wearing ring and bearing
bush, Mechanical seal Sic vs Sic, CS/SS Bearing, SS Shaft with sleeve, SS
strainer and MS motor body.
AVG. FLOW PUMPS
Capacity : 2.38 LPS Head : 9.00 metre.
Motor : (2 HP)
Erection of Non Clog submersible pump with overhead etc. complete.
Avg Flow Pumps -Working each 0 22435.89 4 89743.56
Erection of Non Clog submersible pump with overhead etc. complete.
2 Avg Flow Pumps -Working each 0 22435.89 2 44871.78
Erection of Non Clog submersible pump with overhead etc. complete.
136 NDSR 3 Avg Flow Pumps -Working each 0 22435.89 2 44871.78
Providing, supplying, installation, including cost of all labour, testing &
commissioning of C.I.D.F. NON RETURN VALVE of PN 1.0 rating with CI
FG-260 body & Door, Hinge & Hinge pin of SS 410 and as per latest
137 NDSR revision of IS 5312 for following sizes. For additional parameters refer each 0 4800.00 4 19200
specifications.
100 mm for "1 or 2 or 3" DWF pump line
Providing, supplying, installation, including cost of all labour, testing &
commissioning of C.I.D.F. NON RETURN VALVE of PN 1.0 rating with CI
FG-260 body & Door, Hinge & Hinge pin of SS 410 and as per latest
138 NDSR revision of IS 5312 for following sizes. For additional parameters refer each 0 8501.00 4 34004
specifications.150 mm for "1 or 2 or 3" DWF pump line
Providing, supplying, installation, including cost of all labour, testing &
commissioning of C.I.D.F. NON RETURN VALVE of PN 1.0 rating with CI
FG-260 body & Door, Hinge & Hinge pin of SS 410 and as per latest
139 NDSR revision of IS 5312 for following sizes. For additional parameters refer each 0 25359.00 4 101436
specifications.300 mm for "1 or 2 or 3" DWF pump line
*Providing & supplying, installation, including cost of all labour,
testing & commissioning of CAST IRON KNIFE GATE VALVE manually
hand wheel operated as per latest revision of AWWA C 520/MSS-
140 NDSR SP81. Gate of SS 304. Rising Spindle of SS 410. P.N. 1.0 each 0 7705.00 4 30820
*100 mm for "1 or 2 or 3" DWF pump line or Common header
*Providing & supplying, installation, including cost of all labour,
testing & commissioning of CAST IRON KNIFE GATE VALVE manually
hand wheel operated as per latest revision of AWWA C 520/MSS-
141 NDSR SP81. Gate of SS 304. Rising Spindle of SS 410. P.N. 1.0 each 0 10591.00 4 42364
*150 mm for "1 or 2 or 3" DWF pump line or Common header
*Providing & supplying, installation, including cost of all labour,
testing & commissioning of CAST IRON KNIFE GATE VALVE manually
hand wheel operated as per latest revision of AWWA C 520/MSS-
142 NDSR SP81. Gate of SS 304. Rising Spindle of SS 410. P.N. 1.0 each 0 24543.00 4 98172
*300 mm for "1 or 2 or 3" DWF pump line or Common header
Expasion Bellows
Supply, Installation, Testing & Commissioning including cost of all
labour, jointing material etc. of flanged single EXPANSION BELLOW of
corrugated design with flanges as per EJMA standards of PN: 1.0 and
overall length minimum 300 mm up to size<= 900 mm NB, designed
for 15 mm axial compression and 5 mm axial extension with tie rods
and capcbility to take lateral movements.MOC: Bellow: SA 240 Gr.
143 NDSR 304; Internal sleeve: SA 240 Gr. 304; Weld ends: IS 2062 Gr. B; Flanges: each 0 5595.00 4 22380
IS 2062 Gr. B (Drilling as per IS 1538) and Limit nuts and rods : SS 304).
For additional parameters refer specifications.
100 mm for "1 or 2 or 3" DWF pump line or Common header or Flow
Expasion Bellows
Supply, Installation, Testing & Commissioning including cost of all
labour, jointing material etc. of flanged single EXPANSION BELLOW of
corrugated design with flanges as per EJMA standards of PN: 1.0 and
overall length minimum 300 mm up to size<= 900 mm NB, designed
for 15 mm axial compression and 5 mm axial extension with tie rods
and capcbility to take lateral movements.MOC: Bellow: SA 240 Gr.
144 NDSR 304; Internal sleeve: SA 240 Gr. 304; Weld ends: IS 2062 Gr. B; Flanges: each 0 5869.00 4 23476
IS 2062 Gr. B (Drilling as per IS 1538) and Limit nuts and rods : SS 304).
For additional parameters refer specifications.
150 mm for "1 or 2 or 3" DWF pump line or Common header or Flow
Expasion Bellows
Supply, Installation, Testing & Commissioning including cost of all
labour, jointing material etc. of flanged single EXPANSION BELLOW of
corrugated design with flanges as per EJMA standards of PN: 1.0 and
overall length minimum 300 mm up to size<= 900 mm NB, designed
for 15 mm axial compression and 5 mm axial extension with tie rods
and capcbility to take lateral movements.MOC: Bellow: SA 240 Gr.
304; Internal sleeve: SA 240 Gr. 304; Weld ends: IS 2062 Gr. B; Flanges:
IS 2062 Gr. B (Drilling as per IS 1538) and Limit nuts and rods : SS 304).
Providing and fixing C.I. Scour Valves (with cap) complete with
bolts, nuts, rubber insertions etc. (the tail pieces if required will
be paid separately) :
Providing and fixing C.I. Scour Valves (with cap) complete with
bolts, nuts, rubber insertions etc. (the tail pieces if required will
be paid separately) :
Providing, laying, jointing Pressure Reducing Valve in position
with jointing materials, nut-bolts and giving satisfactory hydraulic
Providing, laying, jointing Pressure Reducing Valve in position
jointing materials, nut-bolts and giving satisfactory hydraulic
Providing & erecting single girder type fully electrically operated E.O.T.
crane with electrically operated hoist, geared travelling trolly with
seven meter lift complete with long travel rail track ( 40 mm sq bar),
moving or cross girder, all three motions electrically operated by
suitable rating motor, control panel & down pendant control
block, brake, safetry device, cables from motor to starter panel & each 0 252179.42 3 756538.26
Other required accessories & tested to 50% overload.
2 Tonne Capacity
Providing & erecting single girder type fully electrically operated E.O.T.
crane with electrically operated hoist, geared travelling trolly with
seven meter lift complete with long travel rail track ( 40 mm sq bar),
moving or cross girder, all three motions electrically operated by
suitable rating motor, control panel & down pendant control
block, brake, safetry device, cables from motor to starter panel & each 0 229743.53 2 459487.06
Other required accessories & tested to 50% overload.
1 Tonne Capacity
*Supply, Installation, Testing & Commissioning including cost of all
labour of CI FG 260 SLUICE GATE as per latest revision of IS 13349 with
wall thimble, SS 410 stem, and all accessories. For additional
152 NDSR parameters refer specifications. each 0 13038.84 2 26077.68
Size: 150x150 mm
*Supply, Installation, Testing & Commissioning including cost of all
labour of CI FG 260 SLUICE GATE as per latest revision of IS 13349 with
153 NDSR wall thimble, SS 410 stem, and all accessories. For additional each 0 85161.26 1 85161.26
parameters refer specifications.
*Supply, Installation, Testing & Commissioning including cost of all
labour of SS 304 MECHANICAL BAR SCREEN as per tender technical
specifications.
154 NDSR Fixed Type Manual Coares Bar Screen Suitable channel dimensions: each 0 314102.48 6 1884614.88
Channel width : 1200 mm
Channel depth : 835 mm Water depth : 335
Bar spacing : 25 mm
Angle of Inclination : 60 degree
TOTAL FOR SUB HEAD - IV
SUB HEAD - I: Water Level Indicator work
Providing and erecting C. l. and M.S ventilating columns 15 cms . dia.
with C.l. ornamental cap and min 6.00 mtr.(Height may beas per
site)base fixed firmly with necessary foundation with one coat of red
lead oxide paint and one coat of any approved colour with 15 cms ,dia
10 mt .in length with 0.35mt*0.35mt encasing stoneware or RCC pipe
connection with M.H. including excavation and jointing as required etc
complete as per drawing.
(For 6 Metre Height )
Providing and fixing Water Level Indicator or depth gauge painted on
TW plank 25 mm / MS plate 4 mm thick float,level indicator sliding
156 NDSR wire on standard pulleys incl.necessary arrangement to prevent the each 0 4706.15 5 23530.75
Supplying & erecting D.C.P. type fire extinguisher for
following capacity cartridge type with gun metal cap 150
gram CO2 gas cartridge, powder and brackets confirming to IS
157 NDSR 2171 1985 and complete erected with necessary clamps made each 0 2243.59 4 8974.36
from 50 x 6 mm M S
Flat with nuts and bolts grouted in wall complete.
TOTAL FOR SUB HEAD - I
SUB HEAD - II: Sewer Cleaning work
Supplying, testing and Commissioning Jetting machinery inclusive of
Four wheeler of MAKE TATA 275/TATA ACE or Equivalent Vehicle with
suitable RPM Triplex Plunger Pump
having minimum capacity 13 LPM and minimum pressure 200 Bar
directly coupled with a separate 10 HP heavy duty, 4 stroke, air cooled
diesel Engine, with water tank having capacity 500 lit. with jetting
158 NDSR hose of 30 m length with ID 1/4", etc. complete with hose reel, each 0 825640.81 1 825640.81
spraying hose and gun, valves, instruments, accessories, with cost of
vehicles etc. complete conforming with tender specifications.
Supplying, testing and Commissioning Jetting cum suction
machinery inclusive of four wheeler vehicle TATA 1613/Eicher 20.16 or
equivalent make with suitable RPM Imported Italian make Triplex
Plunger Pump of running on vehicle engine having flow rate of
minimum 255 LPM and pressure minimum 140 bar with high
pressure jetting hose of I.D.
length 60 mt with MS tank of minimum 5 mm thickness having
159 NDSR total tank capacity 9000 lit. Partitioned with fresh water of 5000 each 0 3534774.73 1 3534774.73
liter and sludge tank of 4000 liter. With suction unit
inclusive of vacuum pump of minimum capacity 390 m3/hr having
maximum vacuum pressure of 85 to 95% having maximum operating
relative absolute pressure of 1.5 bar running on vehicle engine with
Supplying, testing and Commissioning Hydraulic operated cum Winch
Driven De-silting Grab Bucket System inclusive of Four wheeler of
MAKE TATA 275/TATA ACE or Equivalent Vehicle with system
having travelling depth of at least 12 m, steel grab bucket of 20 ltrs
capacity, hydraulic system driven by vehicle engine, 6mm wire
rope with appropriate size reel, with hydraulic cylinder , hydro
motor, flexible hose, oil tank, hopper, boom, hose of appropriate
size etc. complete with valves, instruments, accessories, with
cost of vehicles etc. complete conforming with tender
specifications.
TOTAL FOR SUB HEAD - II
SUB HEAD - III: Operation & Maintanence 0
a MV CABLE LAYING 0
Laying of one number of PVC insulated and PVC sheathed / XLPE
power cable of 1.1 KV grade of following size direct in ground
7.1 including excavation, sand cushioning, protective covereing and 0
refilling the trench etc as required.
Above 185 sq.mm and upto 400 sq.mm
MV CABLE JOINTING & END TERMINATION
Supplying and making end termination with brass compression gland
and aluminium lugs for following size of PVC insulated and PVC
sheathed / XLPE aluminium conductor cable of 1.1 KV grade as 0
Brass compression gland for (22 mm) 2 X 16 SQ.MM
1.1 KV grade cable
SWITCH DISCONNECTOR SFU & MCCB
4 pole MCCB, 250 A, 36kA
Supply, testing and commissioning of armoured PVC / XLPE
insulated type, alumuniumr of the following sizes fixing alluminium
1625 tag numbers at every two meter etc, complete to the satisfaction of 0
EIC (Verify the actual legnth at site)
3.5C X 240 SQ.MM Alu. A2XFY CABLE
End termination of following PVC / XLPE insulated armoured cables
including supply and fixing of brass heavy duty double
compression type cable glands with PVC hoods and crimping type
long barrel heavy duty copper / alluminum lugs (as per conductor of
cable) suitable for terminations of armoured cables, including making
e connection / terminations of all leads of cables, including drilling 0
and tapping of equipment for cable entries as required and including
all labour and materials complete to the satisfaction of E.I.C
3.5C X 240 SQ.MM Alu. A2XFY CABLE
SLUDGE UTILIZATION ARRANGEMENT
Designing, providing, constructing sludge drying beds as per required
capacity, size as per drawings.The sludge drying bed shall be
utilised to dewater sludge via filtration and evaporation. The
perforated pipes of required dia shall be provided at the bottom
of the bed to drain seepage water or filtrate. The sluge drying beds
shall be designed for reduction of about 35% or less in moisture
content after drying. The Sludge drying beds shall be situated beside
NDSR treatment plants to readily receive and treat incoming sludge coming Job 0 1076922.80 1 1076922.8
from primary or secondary treatment facilities.
The basic components of the sludge drying bed shall composed of (i)
concrete structure for bed and walls, (ii) sand and gravel to be used as
filter media, (iii) splash block, (iv) under drain, and (v) inlet. The work
shall be carried out as per CPHEEO manual.
TOTAL FOR SUB HEAD - III
SUB HEAD - IV: Electric Work
Wiring for light point/ fan point/ exhaust fan point/ call bell point with
1.5 sq.mm FR PVC insulated copper conductor single core cable in
surface / recessed steel conduit, with modular switch, modular plate,
suitable GI box and earthing the point with 1.5 sq.mm. FR PVC
insulated copper conductor single core cable etc as required.
Exhaust Fan Point
Wiring for circuit/ submain wiring along with earth wire with the
following sizes of FR PVC insulated copper conductor, single core cable
164 1.7 in surface/ recessed steel conduit as required 0
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For DB to SB and SB to
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing of following sizes of steel conduit along with
accessories in surface/recess including painting in case of surface
165 1.2 conduit, or cutting the wall and making good the same in case of 0
recessed conduit as required.
Supplying and fixing stepped type electronic fan regulator on the
existing modular plate switch box including connections but
excluding modular plate etc. as required. Each 284.00 2.00 568 0
Supplying and fixing suitable size GI box with modular plate and cover
in front on surface or in recess, including providing and fixing 3 pin 5/6
amps modular socket outlet and 5/6 amps modular switch,
connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover
in front on surface or in recess, including providing and fixing 6 pin 5/6
amps & 15/16 amp modular socket outlet and 15/16 amps Each 395.00 4.00 1580 0
modular switch, connection etc. as required.
Supplying and fixing following way, single pole and neutral, sheet
steel, MCB distribution board,240 volts, on surface/ recess, complete
169 2.3 with tinned copper bus bar, neutral bus bar, earth bar, din bar, 0
interconnections, powder painted including earthing etc. as required.
(But without MCB/RCCB/Isolator
2+ 8 WAY, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C"
curve, miniature circuit breaker suitable for inductive load of following
170 2.10 poles in the existing MCB DB complete with connections, testing and 0
commissioning etc. as required.
Supplying and fixing following rating, double pole, 240 volts, MCB in
the existing MCB DB complete with connections, testing and
commissioning etc. as required.
Supplying and fixing following rating, double pole, (single
phase and neutral ), 240 volts, residual current circuit breaker
(RCCB), having a sensitivity current upto 300 milliamperes in the
172 2.14 existing MCB DB complete with connections, testing and 0
commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including
accessories, and providing masonry enclosure with cover plate having
locking arrangement and watering pipe etc. without charcoal/ coke
and salt ) as required
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground
level for conductor earth electrode, including connection/ termination
174 5.7 with GI thimble etc. as required. Metre 27.00 50.00 1350 0
Supplying and laying 25 mm X 5 mm copper strip at 0.50 Meter below
ground as strip earth electrode, including connection/ terminating
with nut, bolt, spring, washer etc. as required. (Jointing shall be done
175 5.8 by overlapping and with 2 sets of brass nut bolt & spring washer Metre 753.00 50.00 37650 0
spaced at 50mm)
MV CABLE LAYING
Laying of one number of PVC insulated and PVC sheathed / XLPE
power cable of 1.1 KV grade of following size direct in ground
including excavation, sand cushioning, protective covereing and
refilling the trench etc as required.
MV CABLE JOINTING & END TERMINATION
Supplying and making end termination with brass compression gland
177 9.1 and aluminium lugs for following size of PVC insulated and PVC 0
sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
CHAPTER-14 MISC. CIVIL ITEMS
Providing, laying and fixing following dia RCC pipe NP2 class (light
duty) in ground complete with RCC Collars jointing with cement
178 14.14 mortar 1:2 (1 cement : 2 fine sand ) including trenching (75 cm 0
deep)and re-filling etc as required.
Supply, installation, testing and commissioning of Panel with seperate
compartment for switchgear compartment. All necessary
compartment shall have locking arrangement etc. complete as per
drawing and specification duly fabricated from 14 / 16 SWG CRCA
sheet, painted with seven tank processed, approved epoxy paints
complete with following components, with internal wiring using
appropriate rated wires, lugs, cable ties, terminal blocks, copper
busbars, copper earth busbar, knock outs for cable entries, m.s.
channel base frame etc. as per drawing and specifications complete . '-
All MCCBs shall be ICS = 100 % of ICU
'- Incomming - 1 : 80 A FP MCCB, 25kA TMD
'- 100 A FP Change Over Switch
'- Phase Indicating Lamps
- Digital Multifunction meter - Voltage, Amperes & Frequency only)
- Outgoings feeder :
DOL Starters (9 - 15) (2 nos.)
Star Delta Starters (9 - 15) (2 nos.)
- 16 A FP MCBs-10kA (1 each)
- 25 A FP MCBs-10kA (4 nos.)
- 40 A DP MCBs-10kA (1 each) (TAKEN IN ABOVE SOR) (All Panel,
MCCB, Relays, Meter etc Should be compitible for auto operation and
Supply, installation, testing and commissioning of Panel with seperate
compartment for switchgear compartment. All necessary
compartment shall have locking arrangement etc. complete as per
drawing and specification duly fabricated from 14 / 16 SWG CRCA
sheet, painted with seven tank processed, approved epoxy paints
complete with following components, with internal wiring using
appropriate rated wires, lugs, cable ties, terminal blocks, copper
busbars, copper earth busbar, knock outs for cable entries, m.s.
channel base frame etc. as per drawing and specifications complete . '-
All MCCBs shall be ICS = 100 % of ICU
- Incomming - 1 : 63 A FP MCCB, 25kA TMD
- 63 A FP Change Over Switch
- 200 A TPN, 440V, 50 Hz., Cu. Busbar.
- Phase Indicating Lamps
- Digital Multifunction meter - Voltage, Amperes & Frequency only)
Supply, testing and commissioning of armoured PVC / XLPE insulated
type, Aluminium conductor of the following sizes fixing alluminium
181 NDSR tag numbers at every two meter etc, complete to the satisfaction of Metre 0 134.62 50 6731
Supply, testing and commissioning of armoured PVC / XLPE insulated
type, Aluminium conductor of the following sizes fixing alluminium
182 NDSR tag numbers at every two meter etc, complete to the satisfaction of Metre 0 112.18 50 5609
4C X 16 SQ.MM Alu. 2XFY CABLE
Supply, testing and commissioning of armoured PVC / XLPE insulated
type, Aluminium conductor of the following sizes fixing alluminium tag
183 NDSR numbers at every two meter etc, complete to the satisfaction of EIC. Metre 0 158.85 20 3177
4C X 4 SQ.MM Cu. 2XFY CABLE
Supply, testing and commissioning of armoured PVC / XLPE insulated
type,Aluminium conductor of the following sizes fixing alluminium tag
184 NDSR numbers at every two meter etc, complete to the satisfaction of EIC. Metre 0 116.67 10 1166.7
4C X 2.5 SQ.MM Cu. 2XFY CABLE
End termination of following PVC / XLPE insulated armoured cables
including supply and fixing of brass heavy duty double compression
type cable glands with PVC hoods and crimping type long barrel heavy
duty copper / alluminum lugs (as per conductor of cable) suitable for
terminations of armoured cables, including making connection /
185 NDSR terminations of all leads of cables, including drilling and tapping of Nos. 0 179.49 4 717.96
equipment for cable entries as required and including all labour and
materials complete to the satisfaction of E.I.C
4C X 4 SQ.MM Cu. 2XFY CABLE
End termination of following PVC / XLPE insulated armoured cables
including supply and fixing of brass heavy duty double compression
type cable glands with PVC hoods and crimping type long barrel heavy
duty copper / alluminum lugs (as per conductor of cable) suitable for
terminations of armoured cables, including making connection /
186 NDSR terminations of all leads of cables, including drilling and tapping of Nos. 0 287.18 2 574.36
equipment for cable entries as required and including all labour and
materials complete to the satisfaction of E.I.C
4C X 2.5 SQ.MM Cu. 2XFY CABLE
Supply, of following Fans / Exhaust fans / Wall fans etc. Including
supply and installation of flexible cords, hardwares etc complete.
Ceiling Fan with condensor A.C. 230V. 50 Cys. 1200 mm sweep
complete having 3 blades alluminium body and blade sets without
regulator, canopy with necesary down rod upto 1000 mm long erected
with 3 core 1.5 qs.mm flexible cable with earthing.
Supply, of following Fans / Exhaust fans / Wall fans etc. Including
supply and installation of flexible cords, hardwares etc complete. 600
188 NDSR mm dia. Exhaust fan heavy duty with louvers with all required Nos. 0 8615.38 8 68923.04
hardwares complete .
Supply, installation, testing and commissioning of following Light
fixtures etc. Including supply and installation of flexible cords, ball
sockets, down rods, hardwares etc. Excluding supply and fabrication
of structural steel supports for industrial fixtures in plant bldgs. but
inclusive of erection of fixtures with all necessary structural steel
supports and to be welded or nut-bolting with all necessary
fabrication and drilling etc.complete.
20W, 2000 Lumens LED Batten light fixture surface mounted with in-
built driver etc complete
Supply, installation, testing and commissioning of following Light
fixtures etc. Including supply and installation of flexible cords, ball
sockets, down rods, hardwares etc. Excluding supply and fabrication
of structural steel supports for industrial fixtures in plant bldgs. but
inclusive of erection of fixtures with all necessary structural steel
supports and to be welded or nut-bolting with all necessary
fabrication and drilling etc.complete.
600 lumens, 6 W EnduraLED Bulkhead light fixture with control driver
duly mounted on wall / ceiling etc. complete
Supplying and erecting, commissioning and testing diesel generating
set having continuous rating, 3 phase, 415 volts, 50 cycles A.C. supply
comprising of a totally enclosed air/water cooled diesel engine with
multi-cylinders developing suitable BHP not less than following
capacity at 1500 RPM with 10% overload for one hour in 24 hours
with standard accessories like fly wheel, lubricating oil cooler, "A"
class governor, heavy duty fuel wheel and lubricating oil filter, oil
bath air filler, lubricating oil pressure gauge, end exhaust
manifold, standard set of tools with adjustable spanners, screw
drivers, feeder gauge, cylinder head to cover, joint cylinder head
to exhaust, element lube oil filter, 12/24 volts electric starting
equipment complete with standard battery, dynamo, cut-outs,
ammeter, necessary wiring, pressure gauge, starter etc and heavy
duty Residential type exhaust silencer and vertical hot air duct both
logged with asbestos rope, save oil trays, exhaust piping of
required length, standard wall/floor mounted fuel with level indicator
and piping and drip proof alternator, self excited, self regulated,
screen protected, with excitation system, capable of delivering the
rated system output at 415 volts, 3 phase, 0.8 PF, 50 Hz, 4 wire,
running at 1500 RPM, conforming to IS-4722- 1968 with voltage
regulation +/- 5% of rated voltage from no load to full load. Both
the engine and alternator fitted on a common fabricated steel
base plate with antivibration mounting engine and alternator both
connected to each other by flexible flange coupling and with
floor/wall mounted control panel box comprising of voltmeter
ammeter, selector switches, ACB / MCCB / MCB of adequate capacity,
indicator lamps duly wired with HRC fuses. The alternator & control
panel shall be connected with provided suitable capacity armoured
cable and complete with Acoustic enclosure (canopy) made out
of 18 SWG CRCA Sheet, sound absorbing material Rockwool of 64
density & 100 mm thick conforming to IS:8183 The resin bonded
rockwool covered from inside the canopy by perforated sheet
with 3/4 mm holes, sound level not more than 75 dB at a
distance of 1 mtr, as per PVCT norms. Erection, commissioning and
satisfactory testing as per requirement with first filling of fuel, oil,
etc. with guarantee of complete system for One year. & with
obtaining all necessary certificate from Electrical Inspector. The
Capacity and Ratings of DG sets are as below.
Continuous Rating of 15 KVA ,BHP not less than 19 BHP
Supplying and erecting, commissioning and testing diesel generating
set having continuous rating, 3 phase, 415 volts, 50 cycles A.C. supply
comprising of a totally enclosed air/water cooled diesel engine with
multi-cylinders developing suitable BHP not less than following
capacity at 1500 RPM with 10% overload for one hour in 24 hours
with standard accessories like fly wheel, lubricating oil cooler, "A"
class governor, heavy duty fuel wheel and lubricating oil filter, oil
bath air filler, lubricating oil pressure gauge, end exhaust
manifold, standard set of tools with adjustable spanners, screw
drivers, feeder gauge, cylinder head to cover, joint cylinder head
to exhaust, element lube oil filter, 12/24 volts electric starting
equipment complete with standard battery, dynamo, cut-outs,
ammeter, necessary wiring, pressure gauge, starter etc and heavy
duty Residential type exhaust silencer and vertical hot air duct both
logged with asbestos rope, save oil trays, exhaust piping of
required length, standard wall/floor mounted fuel with level indicator
and piping and drip proof alternator, self excited, self regulated,
screen protected, with excitation system, capable of delivering the
rated system output at 415 volts, 3 phase, 0.8 PF, 50 Hz, 4 wire,
running at 1500 RPM, conforming to IS-4722- 1968 with voltage
regulation +/- 5% of rated voltage from no load to full load. Both
the engine and alternator fitted on a common fabricated steel 0.00 0 0 0
base plate with antivibration mounting engine and alternator both
connected to each other by flexible flange coupling and with
floor/wall mounted control panel box comprising of voltmeter
ammeter, selector switches, ACB / MCCB / MCB of adequate capacity,
indicator lamps duly wired with HRC fuses. The alternator & control
panel shall be connected with provided suitable capacity armoured
cable and complete with Acoustic enclosure (canopy) made out
of 18 SWG CRCA Sheet, sound absorbing material Rockwool of 64
density & 100 mm thick conforming to IS:8183 The resin bonded
rockwool covered from inside the canopy by perforated sheet
with 3/4 mm holes, sound level not more than 75 dB at a
distance of 1 mtr, as per PVCT norms. Erection, commissioning and 0
satisfactory testing as per requirement with first filling of fuel, oil,
etc. with guarantee of complete system for One year. & with
obtaining all necessary certificate from Electrical Inspector. The
Capacity and Ratings of DG sets are as below.
Continuous Rating of 30 KVA ,BHP not less than 42 BHP
Lightning Conductor
Providing and fixing of lightning conductor finial, made of 25 mm dia
300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6
G.I. base plate including holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate
194 6.3 including holes etc. complete as required. Each 154.00 6.00 924 0
Jointing copper / G.I. tape (with another copper/ G I tape, base of the
finial or any other metallic object) by riveting / nut
bolting/sweating and
soldering etc as required
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or
196 6.7 surface of wall for lightning conductor complete as required. (For Meter 68.00 100.00 6800 0
horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or
197 6.8 surface of wall for lightning conductor complete as required. (For Meter 98.00 50.00 4900 0
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I.
strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and
spring washers Each 71.00 12.00 852 0
etc. complete as required
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT_30.pdf
Tender Document
BOQ_30.pdf
Tender Document
GCC_CONTRACTING_2017.pdf
Tender Document
GCC Amendments 01 to 06.pdf
Tender Document
SCC_30.pdf
Tender Document
Integrity Pact_30.pdf
Tender Document
TECH_Specifications_30.pdf
Tender Document
Soil_30.pdf
Tender Document
1_Schematic_Sewerage Layout.pdf
Tender Document
2_Sewer Collection Network.pdf
Tender Document
Instruction to Bidder for online Bid Submission.pdf
Tender Document
Unconditional Acceptance_30.pdf
Tender Document
Approved makes.pdf
Tender Document
corrigendum-784-NOTICE_30.pdf
pdf • 0.27 MB
corrigendum-755-Corrigendum 07_30.pdf
pdf • 0.60 MB
corrigendum-735-Corrigendum 06_30.pdf
pdf • 0.44 MB
corrigendum-718-Corrigendum 05_30.pdf
pdf • 0.28 MB
corrigendum-699-Corrigendum 04_30.pdf
pdf • 0.28 MB
corrigendum-675-Corrigendum 03_30.pdf
pdf • 0.60 MB
corrigendum-640-Corrigendum 02_30.pdf
pdf • 0.60 MB
addendum-b2b5226885ce-Corrigendum 01 _30.pdf
pdf • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .