Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-AOC SRINIKETAN ROAD BOLPUR BIRBHUM 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L1 | Accepted-AOC AOC Issued | |
| 2 | L2₹3.2 L+₹9,760 (3.10%)Rejected-Finance 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹4.0 L+₹81,545 (25.9%)Rejected-Finance 46 S P MUKHERJEE ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L3 | Rejected-Finance that the bid is not L1 | |
| 4 | L4₹4.2 L+₹1.0 L (33.3%)Rejected-Finance | L4 | Rejected-Finance that the bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹7,000
Closing Date
14 Oct 2022, 1:00 pmClosed
EE II KNHED PW Dte
KIT Building Annex, 4th Floor, P-16, India Exch. Place Extn., Kolkata -700073
Construction of Dean office others office Room along with toilet block inside the Student Section Area under Medical College Kolkata Air Conditioning installation Work
2022_PWDE_406924_1
WBPWD/EEII/KNHED/40Q/2nd Call/22-23
Open Tender
A/C ORG
Item Rate
21 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹7,000
20 Jun 2025
15 Sept 2022
17 Oct 2022
17 Sept 2022
14 Oct 2022
17 Sept 2022
Amount
Dismentaling the existing A.C Machine (including electrical connection) both indoor & outdoor and submit the pwd section office as per direction of EIC
Supply & delivery 2.0 TR capacity concealed type Split Air Conditioner R410a of rated cooling capacity of 24000 BTU/hr, with 1 No. Rotary compressor, 1 No. IDU of rated power supply - 230V - 1ph-50Hz, 1 No. ODU of rated power supply - 230V, 1ph, 50 Hz, Air-flow/per IDU :- 800cfm, (Make : Hitachi 00370099/ Mitshubishi Electric/Blue ster/Voltas)
Erection, testing and commissioning charges for the above said 2.0 / 1.5 TR concealed Split AC. The Indoor (IDU) & Outdoor (ODU) unit must be supported by structure made of 40 x 40 x 5 mm amgle and tie rod incl. necy. Painting & as per direction & satisfaction of EIC.
Copper Refrigeration pipe line for Liquid Line hard drawn Cu piping (1/4" OD with 0.6 mm thick) & Copper Refrigeration pipe line for Suction Line hard drawn Cu piping (5/8" OD with 0.7 mm thick) with necy supports & brackets as per direction of EIC
Supply & Fixing of Nitrile Rubber tube insulation (make : Twiga) of 9 mm thick on Suction & Liquid Line Copper Pipe.
Control Cabling from Condensing Unit to Control Panel, 4 core 2.5 sq.mm. communication Cable (Mk. Finilex / Havell's)
Supply and fixing flexible double canvass connection for concealed split air conditioners
Supply and fixing of Al poeder coated continious Grill
Supply & laying PVC Drain Pipe 25 mm dia with necy claming arrangement as per direction of EIC
Charges for Scaffolding arrangement including lifting for outdoor & indoor units.
Supplying, fitting & fixing in position suspended false ceiling with frame work of aluminium hollow section of size 50mm x 25mm (2.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm having size of 600mm x 600mm ceiling with aluminium composit panels (ACP) - Interior grade of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent complete in all respect including all incidental charges etc. as per direction of Engineer - in - charge. (PWD Bldg Schedule, Part G,P / No. 167, Item 22)
Construction of Trap Door (after proper cutting of ACP covering) made of Heavy Gauge Channel and particle board (hinged type door) for concealed split IDU maintenance as per direction of EIC. (Trap Door Size 3' x 1.5').
Supply & fixing of MS grill protection for refrigerant copper pipe line by 20" x 20" x 3 mm thick MS angle and suitable size MS flat/ rod including weilding as per direction of EIC incl necy painting
Terms&conditions: All tests mentioned above done by agency as per proper guidline given by EIC with co's own instruments,tools and tackles.Copy of calibration certificate of different instruments must be provided prior to any measurement to the EIC. Test results must be registered and provided by the agency as per proper proforma and guidline given by the EIC and same report should be provided in quadraplicate to the dpt.
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Rate should be quotated including all taxes and duties)
Defect Labilities period for 02 year from the date of completion of work. (Rate should be quotated including all taxes and duties)
CARRION AIR COOLING
C. CHOWDHURY AND CO
Auto-Tech Projects Pvt.Ltd.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .