Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 CrAccepted-AOC | ₹7.3 Cr | L1 | Accepted-AOC Awarded being L1 |
| 2 | L2₹7.9 Cr+₹57.9 L (7.93%)Rejected-Finance 10 SHANTI VIHAR RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263153 | UDAM SINGH NAGAR | UTTARAKHAND | 263153 | ₹7.9 Cr+₹57.9 L (7.93%) | L2 | Rejected-Finance Rejected being L2 |
| 3 | L3₹8.2 Cr+₹89.3 L (12.2%)Rejected-Finance | ₹8.2 Cr+₹89.3 L (12.2%) | L3 | Rejected-Finance Rejected being L3 |
| 4 | L4₹8.5 Cr+₹1.2 Cr (16.3%)Rejected-Finance | ₹8.5 Cr+₹1.2 Cr (16.3%) | L4 | Rejected-Finance Rejected being L4 |
| 5 | L5₹8.9 Cr+₹1.6 Cr (21.8%)Rejected-Finance | ₹8.9 Cr+₹1.6 Cr (21.8%) | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹6.6 Cr
EMD Value
₹6.5 L
Closing Date
22 Feb 2022, 6:00 pmClosed
CE Lucknow Zone
HQ CE Lucknow Zone 17 Cariappa Road Lucknow Cantt-226002
PROVISION OF OTM ACCN AT NEW CANTT ALLAHABAD
2021_MES_495985_1
CELZ/ALD/T-32 OF 2021-2022
Open Tender
Civil Works
Lump-sum
540 days
Allahabad
As per Tender documents
7 documents required · 7 mandatory
₹3,000
Yes
GE (Project) Allahabad
₹6.5 L
Yes
6 Apr 2022
18 Dec 2021
24 Feb 2022
18 Dec 2021
22 Feb 2022
8 Feb 2022
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5.
Total amount of Sch 'A' Part II (Site clearance, excavation and earth work)
Total amount of Sch 'A' Part III (Internal Water Supply )
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (Road, Path & Culvert )
Total amount of Sch 'A' Part VI (Sewage Disposal)
Total amount of Sch 'A' Part VII (Area Drainage)
Total amount of Sch 'A' Part VIII (External Water Supply )
Total amount of Sch 'A' Part IX (External Electrification )
Total amount of Sch 'A' Part X (Refrigerator & Air Conditioning)
Total amount of Sch 'A' Part XI (Solar Water Heater )
Total amount of Sch 'A' Part XII (Football Ground and Basket ball Court)
Sch 'A' Part - XIII (Miscellaneous Items) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 siginifies this fact only.
INTERNAL WATER SUPPLY S& F of health faucent (1.5m tube) with hook ( hand spray) with CP body for 15 mm bore pipe complete all as specified and directed.
S& F of Angle cock, cast copper alloy chromium plated ISI marked, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule of 15 mm bore & fixed, complete all as specified and directed.
S& F of Shower rose fency type brass chromium plated 125 mm size with swivel joint suitable for 15 mm bore GI pipe complete all as specified and directed.
INTERNAL ELECTRIFICATION M&L for Point wiring complete for One light/Fan/Exhaust Fan point controlled by one switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for One light point controlled by two way switches with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on an independent board, with PVC insualted and unsheathed FRLSH CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall / roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost..
M&L for Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on same board, with PVC insualted and unsheathed FRLSH CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and MS conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :-In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for point wiring complete with PVC insulated and unsheathed, FRLSH cable 2.5 sqmm (nominal area) ,ISI marked, stranded copper conductor single core including ISI marked 20mm dia medium grade PVC conduit concealed in wall and MS conduit in roof/floor slab, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm, FRLS cable PVC insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories and all as specified. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Supply and fixing Switch flush type 5/6 Amps single pole two way complete all as specified and dierected..
Supply and fixing Telephone Socket with ISI marked complete all as specified and dierected..
Supply and fixing TV Scoket with ISI marked complete all as specified and dierected..
Supply and fixing LED batten Tube light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 FT 20 W), luminaire lumen >2000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed
S&F LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 9 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed.
S&F LED Building security light fitting with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption <20 W (14W) & luminaire lumen >2500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including three core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers complete all as specified and directed.
S&F round shape 12 watt 220 volts AC recessd type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F Mirror light Decorative ultra slim square profile liner LED lighting fixture with extruded polycarbonate body with Minimum 8 Watt & Maximum 11 Watt LED warm white in colour with a luminous efficacy of 120 lum/watt(min) with PF not less than 0.9 with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed.
S&F Engejment light Red and Green 11 Watts LED bulb complete fitting decorative type with ISI marked complete all as specified and directed.
S&F circular slim surface LED Decorative Wall mounting of 12 Watts with LED Bulb 12 watts complete Polycarbonate housing, globe type Glass protection with high transmitivity non yellowing PMMA diffuser for better light output and uniform light distribution without glare, power consumption <12W, luminaire lumen>1000lm, driver and accessories to be prewired, CRI>70, LED efficiency > 120 lm/W photo biological safety report as per IEC624718 & electrical insulation class I, LED life with L70 criteries -37000 hrs colour temp >6000K, Ingress protection IP-20, ambient temperature 0 to 450C, driver efficiency >85%, THD<10% as per IEC 61000-3-2, power factor >0.95, surge protection 2.5 KV, two stages isolatated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM79 & LM80 certification.
Supply and fixing Ceiling fan 1200 mm sweep single phase 230V AC, ISI marked alongwith steel down rod and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long with PVC connector 2 way/3 way for connection complete all as specified. Make Bajaj model Electra 50 or technocommercially equivalent in Philips/Crompton.
Supply and fixing Ceiling fan 1400 mm sweep single phase 230V AC, ISI marked alongwith steel down rod and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long with PVC connector 2 way/3 way for connection complete all as specified.. Make Bajaj model Electra 50 or technocommercially equivalent in Philips/Crompton.
Supply and fixing Exhaust Fan high quality engineering plastic, resistant to colour change with anti- statio properties (ventil air) 200 mm sweep 35 watt ,1200 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to exhaust fan motor complete all as specified and directed. Make- Usha/Baja/havells/CG.
Supply and fixing Exhaust Fan high quality mettalic body, resistant to colour change 300 mm sweep ,900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor complete all as specified and directed. Make- Bajaj model no Supreme Dlx /havells/CG
Supply and fixing Exhaust Fan high quality mettalic body, resistant to colour change 450 mm sweep ,900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor complete all as specified and directed. Make- Bajaj model no Supreme Dlx /havells/CG
MCCB 4 pole ,415 V ,AC fixed type 125 amps with breaking capacity 10 KA complete all as specified and directed.
MCCB 4 pole ,415 V , AC fixed type 63 amps with breaking capacity 10 KA complete all as specified and directed.
MCCB VTPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed. Note: MCCB shall be measured and paid seprately under respective item.
Supply and fixing MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 4 way ISI marked all as specified and directed
Supply and fixing MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 8 way ISI marked all as specified and directed
Supply and fixing MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 12 way ISI marked all as specified and directed
Submain wiring with two single core 2.5 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including 2.5 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly complete all as specified. Note:- (i) Two single core 2.5 sqmm copper conductor, one run PVC conduit and one run of 2.5 sqmm earth wire shall be considered & measured as one unit. (ii) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Submain wiring with two single core 4 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including 4 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified. Note:- (i) Two single core 4 sqmm copper conductor, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit. (ii) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Submain wiring with two single core 6 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including 6 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified. Note:- (i) Two single core 6 sqmm copper conductor, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit. (ii) In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using GI earth wire 4 mm dia as earth electrode connected to bolts, nuts, check nuts and washers of GI or steel etc at one end and connected to equipment at another end.GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipment 20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover slab of 50 mm thick precast RCC (1:1.5:3) type A-1 duly reinforced with MS TMT bars 8 mm dia @ 150 mm c/c both ways with 10 mm dia MS round bar as in lifting handles, excavation earth work including laying the GI pipe concealed in floor/wall all as described in electric plate no 3 of SSR part I complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Earthing wire beyond 7.5m shall be measured and paid separately.
ROAD PATH & CULVERT M & L for preparing black top surface of road and applying thermo plastic paint on marking of 2.50 mm thick single coat a center line, stop line, side line etc on roads as per IRC pattern. Road marking of 150/100 mm width using hot mark thermoplastiv paint hot application) white or yellow by indineous modem propelled road marking machine as directed including all ingredient such as binder, glass bends, titenium dioxide, calcium carbonate, inter fillets etc. Thermoplastic requirment for glass bends shall be cofirming to BS-6086 of MORTH specification including spraying of glass bends etc. as per IRC-35 with and including traffic diversion arrangement complete all as specified and directed.
EXTERNAL WATER SUPPLY Construction of brick masonary valve pit chamber of size 950mm x 950 mm x 950mm (internal dimensions ) including necessary excavation and earth work, PCC work in the foundation and top of the wall, plaster on internal surfacess with CM 1:4 cement mortar, Mild steel cover 3.15 mm thick and angle iron 40mmx40mmx6mm frame , locking arrangements with lock and key /pad lock brass 4 levers with key in duplicate), duly painting the steel surfacess with two coat of synthetic enamel paint over on coat of Red oxide primer complete all as specified shown on drawing and as directed.
Construction of brick masonary valve pit chamber of size 450mmx450 mm x450mm (internal dimensions ) including necessary excavation and earth work, PCC work in the foundation and top of the wall, plaster on internal surfacess with CM 1:4 cement mortar, Mild steel cover 3.15 mm thick and angle iron 40mmx40mmx6mm frame , locking arrangements with lock and key /pad lock brass 4 levers with key in duplicate), duly painting the steel surfacess with two coat of synthetic enamel paint over on coat of Red oxide primer complete all as specified shown on drawing and as directed.
Supply and laying pipe ductile iron S/S including specials, Class K-9, 100 mm dia complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply installation, commissioning and testing of transformer copper wound step down 160 KVA out door type 11/0.433 KV at no load 3 ph, 4 wire 50 HZ AC with oil immersed naturally cooled, delta connected on HV side and star connected in LV side in accordance with vector symbol DY-II with neutral brought out on secondary side and having tapping in step of ± 2.50½ %, ± 5% and ± 7.5 % to be changed by mean of hand operated OFF load tap changing gear including first fill of transformer oil as per IS-335, and including all fittings/accessories as specified in SSR Part I and as per revised IS-1180-2014, trannsformer should have cable box on LT side and exposed brass bushings on HT side, oil temprature gauge,dehydrating breather with first fill of dehydrating agent, oil conservator tank, explosion vent, rating and terminal marking plate, oil level gauge, oil drain and filter valve, providing independent earthings terminals for neutral and body ,PCC foundation of size 4 mtr (L) x 4 Mtr (W) x 1.20 mtr (H) alongwith chain link fencing & Gate complete as directed by Engineer-in-Charge as per TD-699 CELZ complete in all respect and all other standard accessories etc all as specified and directed. The transformer shall be complete in all respect and all other standard accessories etc all as specified with following accessories:-
Oil conservator tank with filling holesa and cap, filter type drain valve and oil level guage.
Silica gel breather with conecting pipe and first fills of dehydrafting agent.
Air release valve plug.
One table box on LV side (secondary) consisting of 04 nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out one 3 1/2 core, 240 Sqmm LT 1100 Volts grade cable including gland joints complete all as specified.
01 No 100mm dia type thermometer vapour pressure type having rating 0-120 degree centigratde with max temp indicator and resetting device inc max reading pointer washers etc.
Thermometer pocket on tank cover.
04 Nov Plain Solid CI detachable rollers.
Two numbers earthing termonals on tank cover to facilitate GI earth strip.
Rating plate and terminal marking plate.
Extra bushing for neutral outside the cable box brought on LV side.
Fidrst filling of oil confirming to IS and tested upto 50 KV/2.5mm dielectric stregnth
Lifting Lugs
Oild drain valve with plug
03 Nos Porcelain HV bushing with arching horns on HV side suitable for 11 KV complete bushing rods, nuts and wahsers etc.
Explosive vent
Note : Any other parts/items not specified above but have been considered essential for smooth and safe functioning of the transformer system shall be included in the items and are covered against the quoted rate.
Supply, laying, jointing, testing and commissioning of HT XLPE cable insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (Heavy duty) with aluminium stranded conductor 11 KV 'Earthed' grade conforming to IS 7098 (Part II) through pipes/ducts/trenches/under floor/under road of size 95 Sqmm 3 core complete all as specified and directed. Make: Havells/Gloster/Polycabs
Supplying, fixing, jointing and testing cable jointing kit for 11 KV (earthed) grade cable for outdoor termination cold shrink type joint complete with jointing materials and accessories suitable for HT XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed.
Supply and erecting Steel tubular swaged pole complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-55, 11 mtr long, all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Supply and erecting Steel tubular swaged pole complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-31, 9 mtr long, all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm thick by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B-1 using 20 mm graded stone aggregate, mild steel frame made out of angle iron of size 40 mm x 40 mm x 3 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 40 mm dia light grade GI pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No. 3 connected to earthing test point all as specified and indicated including testing on completion as directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 25 x 4 mm thick by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B-1 using 20 mm graded stone aggregate, mild steel frame made out of angle iron of size 40 mm x 40 mm x 3 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 40 mm dia light grade GI pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No. 3 connected to earthing test point all as specified and indicated including testing on completion as directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 10 Sqmm 2 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 10 Sqmm 4 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 16 Sqmm 4 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 25 Sqmm 4 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 35 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 70 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 120 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 240 Sqmm 3.5 core complete all as specified and directed.
Supply & fixing LED street light luminaire 70 watt IP 66 230 V AC outdoor type with high pressure dia cast aluminum housing and heat resistant complete with driver including bracket of 32 mm dia light grade GI tubing 1.20 m long bend to shape with suitable size nut, bolt & washer etc including making cable connection with 3 core PVC insulated copper conductor cable of 1.5 sqmm all as specified and directed.
Supply & fixing DK thermoplastic cable junction box IP 65 with metric knock outs for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 3.5/4 core and fixed to the PSC/Steel pols by means of suitable size of clamps with nut, bolt and washer with and including locking arrangement fixed to pole complete all as specified and directed. Sintex/Hensel or equivalent as approved by GE.
Supply and fixing sheet metal enclosure factory made with synthetic enamel painting complete and fix to the LT pole with suitable size FI clamp including time switches Digital type 24 hour 415 volts three phase of Max load 6 KW with contactor 32 Amp TP with One MCB 40 Amp TPN rating complete all as specified and directed
New generation, post top lantern , energy saving LED 40 WATT, aesthetically designed with symmetric light distribution including minimum half meter pole of suitable size dia grouted in PCC and cable connection by means of 3 core 1.5 sqmm copper conductor complete all as specified and directed. Make: CAT PART NO - SLE PT 40 W-ETPP of Surya/BGCT W4LED of BAJAJ, WW/LPTO-40-CDL of Crompton..
Electrolytic Copper bus bar, 3 Nos high conductivity properly insulated of 530 Amps for phases and 1 No of 265 Amp for neutral with provision of extension and mounted on heavy duty rubberised/porcelain support -03 Nos .
INCOMING: MCCB 350 Amp, 4 Pole, 50 Hz, 415 V with rupturing capacity 36 KA adjustable thermal magnetic and microprocessor 50 Hz -01 no
OUTGOING : MCCB 125 Amp, 4 Pole, 415 Volts with rupturing capacity 25 KA adjustable thermal magnetic release 50Hz- 01 No
MCCB 100 Amp, 4 Pole, 415 Volts with rupturing capacity 25 KA adjustable thermal magnetic release 50Hz- 02 Nos
MCCB 40 Amp, 4 Pole, 415 Volts with rupturing capacity 16 KA adjustable fixed and thermal magnetic release 50Hz- 02 Nos
RYB LED indicating lamp -01 Set (set of three)
Insulated copper bus bars suitable size shall be provided from the main bus bar to the outgoing MCCB's.
Wiring of panel complete all as specified and directed.
Drawing shall be approved by GE before placing the order.
Electrolytic Copper bus bar, 3 Nos high conductivity properly insulated of 200 Amps for phases and 1 No of 100 Amp for neutral with provision of extension and mounted on heavy duty rubberised/porcelain support -03 Nos .
INCOMING: MCCB 125 Amp, 4 Pole, 50 Hz, 415 V with rupturing capacity 25 KA adjustable thermal magnetic and microprocessor 50 Hz -01 no
OUTGOING : MCCB 63 Amp, 4 Pole, 415 Volts with rupturing capacity 16 KA adjustable Fixed and thermal magnetic release 50Hz- 02 No
MCCB 40 Amp, 4 Pole, 415 Volts with rupturing capacity 16 KA adjustable thermal magnetic release 50Hz- 02 Nos
MCB SPN 10 Amp, 220 Volts - 02 Nos
RYB LED indicating lamp -01 Set (set of three)
Insulated copper bus bars suitable size shall be provided from the main bus bar to the outgoing MCCB's.
Wiring of panel complete all as specified and directed.
Drawing shall be approved by GE before placing the order.
Electrolytic Copper bus bar, 3 Nos high conductivity properly insulated of 150 Amps for phases and 1 No of 75 Amp for neutral with provision of extension and mounted on heavy duty rubberised/porcelain support -03 Nos .
INCOMING: MCCB 100 Amp, 4 Pole, 50 Hz, 415 V with rupturing capacity 25 KA adjustable fixed and thermal magnetic 50 Hz -01 no
OUTGOING : MCCB 63 Amp, 4 Pole, 415 Volts with rupturing capacity 16 KA adjustable Fixed and thermal magnetic release 50Hz- 02 No
MCCB 40 Amp, 4 Pole, 415 Volts with rupturing capacity 16 KA adjustable thermal magnetic release 50Hz- 01 Nos
RYB LED indicating lamp -01 Set (set of three)
Insulated copper bus bars suitable size shall be provided from the main bus bar to the outgoing MCCB's.
Wiring of panel complete all as specified and directed.
Drawing shall be approved by GE before placing the order.
REFRIGERATOR, WATER COOLER,DESERT COOLER Supply and installation of desert cooler electric driven motor heavy duty with operating regulator (single phase) having nominal air flow of capacity 5000 Cum/hour complete with exhaust fan motor 450 mm sweep suitable RPM and submersible water lifting pump 2.80 m head 230 Volts AC including locally fabricated cabinet with three side panels front top and tank including vertical mention made out of 22 SWG PGI sheet of size not more than 121.10x76.50x55.5 cm with front side chequerd mess including horizontal and vertical manually operated air diverted fins including 4 way PVC distributer, PVC pipe 3 to 4 mtr for spray water, wood wool pads, plastic electrical box having two Nos 5 Amps piano switch and indicator lamp including suitable size stand for outdoor mounting of dessert cooler complete with electric wiring for fan & pumps controlled separately complete al as specified and directed. Make of sheet :- Jindal/Tata Make of Cooler :– Champion, Ram Coolers or equivalent make as approved by GE.
Refrigerator of capacity 200 liter , electric driven, single phase, 230 volt, AC, 50 Hz single door 3 star rated including plug top 15 Amps and necessary electric connection complete all as specified and directed.
Supply and installation of Voltage stabilizer of capacity 1.00 KVA for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of + 2.5 % complete all as specified and directed..
Supply and installation of Voltage stabilizer of capacity 3.00 KVA for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of + 2.5 % complete all as specified and directed.
Supply and installation of Voltage stabilizer of capacity 5.00 KVA for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of + 2.5 % complete all as specified and directed.
SOLAR WATER HEATER Supply and installation of 25 litres capacity water heater storage type, electric driven (Single phase) BEE 3 Star rated in the year of execution with thermostat, auto cutoff, copper tank, release valve, nob return valve and indicator lights complete all as specified and directed.
M&L for Hot water inlet/outlet connection made of brass chromium plated with Uion rubber washer suitable for 15 mm bore GI pipe for hot water complete all as specified and directed.
FOOT BALL GROUND AND BASKET BALL COURT Supply, assembling and grouting complete basket ball pole set (Pair) made out of 150mm dia heavy duty pipe, board of fiber glass board size 1.80mx1.05mx18mm thick with angle iron 35x35x5mm frame and Dunkin rings with Net etc complete all as per standard specifications and directed.
M/S Amar Enterprises
M/s NSA Engineering Corporation
DEORA ELECTRIC WORKS
SEAHAWK ENTERPRISES PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .