Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.8 L+₹1.3 L (8.63%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹19.1 L+₹3.6 L (23.2%)Rejected-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L3 | Rejected-AOC L3 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Kislay Kishore, IDSE
GE (AFA) Hyderabad PIn-500043
REPAIR TO ELECTRIC FOUR POLE STRUCTURES AND OTHER OUTDOOR ELECTRIC INSTALLATIONS AND RELATED ELECTRIC CABLE WORKS IN TECHNICAL AND PERIMETER AREA AT AFA HYDERABAD
2022_MES_549198_1
8270/E8
Open Tender
Civil Works
Item Rate
330 days
GE (AFA) Hyderabad
As per tender docuements
4 documents required · 4 mandatory
₹500
GE (AFA) Hyderabad
₹40,000
Yes
16 Dec 2022
1 Sept 2022
5 Oct 2022
1 Sept 2022
3 Oct 2022
19 Sept 2022
1 Sept 2022 - 14 Sept 2022
Amount
M&L for attending breakwown complaints and restoring power in external electrical distribution line by identifying the fault , ascertaining cause of the fault and under taking repairs such as replacing fuse wire , cut in jumpers , tighting of loose jumpers , replacing of defective insulators,Lugs & MCCBs etc, including checking of servicebility of cables by meggring process ,checking of LT switch gears, earthing and other equipments such as VCBs, RMUs & Transformer etc all as specified and directed
(i) Contractor will have to deploy not less then 01 Skilled Electrician and 01 Helper round the clock i.e 24x7 so as to attend complaints at any time.
(ii) Items for minor repairs for restortion of electric supply such as fuse wire, Insulation LT tapes and all types of Al Lugs shall be provided by the contractor . All Tools & Plants required for repair work shall be provided / arranged by the contractor at his own arrangement and expense to the trade men & helpers.
(iii) All complaints should be attended with in 01 hour of reporting of complaints. Penalty charges for non attending complaints with in 24 hrs shall be Rs 1000/- per complaint .
(iv) Any other items for restortion of electric supply will Paid under relevent items
(v) A joint inspection for checking of serviceability of all LT switch gears will be carried out with contrator's representative, user's representative and MES personal in every month.
Supply only pin type ,Polymer insulator of any type upto 11 KV capacity 320 cd 5 kn complete including all accessories yoke,clamps,nuts,bolts etc complete all as specified and as directed.
Supply only Disc type ,Polymer insulator of any type upto 11 KV capacity 320 cd 45 kn f complete including all accessories yoke,clamps,nuts,bolts etc complete all as specified and as directed.
Supply & Fix (In repairs) 3 Pole power contactor of AC 3 duty rating of 40 amps having 240 volts rated no volt coil and having 2 NO (Normally open) + 2 NC (Normally closed) configuration- 01 No all as directed
Supply only 3 Pole power contactor of AC 3 duty rating of 63 amps having 240 volts rated no volt coil and having 2 NO (Normally open) + 2 NC (Normally closed) configuration- 01 No all as directed
Supply & Fix (In repairs) ACSR conductor in OH lines conductor (Squirrel / Weasel / Rabbit) including binding with aluminium wire complete all as specified and as directed .
Supply only MCCB adjustable thermal & fixed magnetic release 4 pole 50 kA 400 A , connecting up complete all as directed at site.
Supply only MCCB adjustable thermal & fixed magnetic release 4 pole 35 kA 250 A , connecting up complete all as directed at site.
Supply only MCCB adjustable thermal & fixed magnetic release 4 pole 35 kA 200 A , connecting up complete all as directed at site.
Supply only MCCB adjustable thermal & fixed magnetic release 4 pole 16 kA 160 A including dismantling and taking out the existing unserviceable MCCB , connecting up complete all as directed at site.
M&L for cleaning of outdoor electric substation /Four pole structures /Two pole structure area free of vegetation and creepers by cutting vegetation/ grasses including cleaning the substation upto 3 meter outside fencing including removal of cut vegetation to a distance exc 250 m and not exc 500 m as directed and applyiing weedicide alongwith periphery for one meter width as specified
(i) List of Installation as in PS . Contractor to visit site for quoting.
M&L Repairing of panel boards / busbar of any size by removing of incomer/out going cables and connecting the same with same size of new lugs , nut bolts & welded the damgaged / broken portion making all doors to freely operatable by using grease and painting of two coats of synthetic enamel paint over one coat of red oxide primer for metal surface of panels/ busbar surface area etc.
Excavation in trenches in any kind of soil n.exc 1.5 m wide and n. exc 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables complete all as specified and as directed.
M&L River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punned thickness up to 18 cm and consolidation, complete all as directed. Note :- Punned thickness only will be considered for payment.
Returning, filling in trenches in any kind soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, and well ramming complete all as specified and directed.
Supply & lay common burnt, clay building bricks, sub class 'B' designation over the sand cushioning in cable trenched for protection of cables (LT) complete all as specified and as directed
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed
Taking down old Unserviceable XLPE UG cable any type and any size all as directed
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured conforming to relevant IS specifcations with aluminum conductor of size 10 sqmm 4 core laid in trenches or walls all as directed.
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured conforming to relevant IS specifcations with aluminum conductor of size 16 sqmm 4 core laid in trenches or walls all as directed.
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured conforming to relevant IS specifcations with aluminum conductor of size 95 sqmm 3.5 core laid in trenches or walls all as directed.
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 120 sqmm 3.5 core laid in trenches or walls all as directed.
POWER CONSTRUCTION COMPANY
L and S ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .