Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹21.4 L+₹43,815 (2.09%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹22.0 L+₹99,940 (4.76%)Rejected-AOC 1 16 70 SAI NAGAR COLONY ALWAL SECUNDERABAD 500 015 | SECUNDERABAD | HYDERABAD | TELANGANA | 500015 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹25.8 L+₹4.8 L (22.7%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
23 Nov 2022, 6:00 pmClosed
CWE KARANJA
CWE KARANJA NAVAL STATION KARANJA URAN RAIGAD - 400704
PREVENTIVE MAINTENANCE OF DG SET AND CONTROL PANEL INCLUDING REPAIR AND REPLACEMENT OF DISPLAY BOARD AND PAINTING OF MACHINERIES IN TUNIR AND COMMON AREA AT NAVAL STATION KARANJA
2022_MES_560218_1
84184-K/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NAVAL STATION KARANJA
Please refer tender documents
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER (NW) KARANJA
₹70,000
6 Dec 2022
28 Oct 2022
25 Nov 2022
28 Oct 2022
23 Nov 2022
11 Nov 2022
Amount
Annual maintenance contract for DG Set 750 KVA, Make - Crompton Cummins, through authorised service agency of OEM, Location: (DG SET -1, Near club TP) complete all as specified and as directed by Engr-in-charge. Note: Spares required for above maintenance will be measured and paid separately under relevent items and the AMC involving the following scope of works: (I) Scope of works: (a) Check the sample of coolent concentration. (b) Check the fan belt for tension and replace if needed. (c) Check exhaust condensate drain and remove any debris or dust. (d) Examine the charge level of battery and check for any loose connection and de-scale carbon deposits if any on terminals and application petroleum jelly. (e) Check the air cleaner components and clean the dirt with air pressure. (f) Check and adjust the voltage level of the battery charger. (g) Drain out the water from the container of the bottom of the filter housing and fuel tank. (h) Check the control panel wiring, instrumentation, contact fuses, etc., (j) Check the specific gravity of battery every month and condition of plates once in three months. (k) Check the serviceability of safety controls of engine. (l) Checking of all electrical connections for its proper tightness. (m) Check AVR connections and power cable connections for tightness.
(n) Check RPM/ frequency and adjust it. (o) Checking of Load balancing of alternator/ AMF panel output. (p) Check the condition wire breaded/ nonbreaded hoses of engine. (II) In addition to above the following checks will be carried out by contractor in six monthly: (a) Replace the fuel filter and oil filter. (b) Clean the crank case breather. (c) Check the radiator hoses. (III) In addition to above the following checks will be carried out by contractor annually: (a) Greasing of alternator bearing. (b) Cleaning the diesel tank. (c) Check the installation. (d) Checking of exhaust back pressure. (e) Checking of temperature of exhaust. (f) Check the performance of radiator. (IV) Unit rates quoted shall be inclusive of the following: (a) Checking of all rotary and stationery parts of engine and adjust/ repair the defects as required for satisfactory running of DG set. (b) Cleaning and refitting the air cleaner.
(c) Cleaning of fuel filter assembly and replacement of filter element along with rubber 'O' ring. (d) Replacement of 'V' belt for driving radiator fan/ water pump/battery charger alternator with proper adjustment. Repair to nozzle by replacement plunger and spring valves. Replacement of high pressure stainless steel tubing not less than 1m length from FIP to nozzle including benjoo bolts, copper washer etc., Replacement of upper gasket kit. (e) Renewal of oil filter elements including checking of serviceability of lubricants oil pump and repair where necessary for proper oil pressure. (f) Drain out the lub oil and refill new oil after proper cleaning. (g) Checking and adjustment of tappet clearance. Notes: (i) In case of any breakdown service engineer shall attend the break down immediately and make the DG set serviceable within 24 working hrs. (ii) Repair, if any must be carried by contractor through authorised workshop of original manufacturer and payment will be made to the contractor on produce of original manufacturer's bills/vouchers.
All as per item No. 1.00 here-in-before but for 500 KVA DG set Make: Kirloskar (Tunir DG Set-1) complete all as specified and as directed by Engr-in-charge.
All as per item No. 1.00 here-in-before but for 400 KVA DG sets Make: Kirloskar CG (Near SUB Station 'K' long term, MRF INS Tunir, STP Near firing range DG set-3) complete all as specified and as directed by Engr-in-charge.
All as per item No. 1.00 here-in-before but for 380 KVA DG sets Make: Cummins (Eklavya Hanger DG set-1) complete all as specified and as directed by Engr-in-charge.
All as per item No. 1.00 here-in-before but for 200 KVA DG sets Make: Kirloskar, CG, KOEL (Abhimanyu sub station B, MRF sub station (I), NAD AC magazine 75 Ton (DBM-19 & 18 DG set-4) complete all as specified and as directed by Engr-in-charge.
All as per item No. 1.00 here-in-before but for 250 KVA DG set Make: Crompton Greaves, KOEL (Jetty sub station, Map saillor MD accn and SM-39 Missile workshop DG-3) complete all as specified and as directed by Engr-in-charge.
All as per item No. 1.00 here-in-before but for 160 KVA DG set Make: Kirloskar (Main w/s pump house Tunir DG -1) complete all as specified and as directed by Engr-in-charge.
All as per item No. 1.00 here-in-before but for 180 KVA DG set Make: Cummins (Map office Accn, FODC and Bldg No 515, 385 and 388 (Opposite ATIME Sub station) DG-3) complete all as specified and as directed by Engr-in-charge.
All as per item No. 1.00 here-in-before but for 125 KVA DG set Make: Kirloskar (ISAT Chamber RMSFF, 84-leading, ISAT Chamber NAI Fire fighting pump house and RFS Tunir area DG-4) complete all as specified and as directed by Engr-in-charge.
All as per item No. 1.00 here-in-before but for 110 KVA DG set Make: Kirloskar (36 Lt cdr md Accn (P/H) DG -1) complete all as specified and as directed by Engr-in-charge.
All as per item No. 1.00 here-in-before but for 82.5 KVA DG set Make: Cummins (War head DG-1) complete all as specified and as directed by Engr-in-charge.
All as per item No. 1.00 here-in-before but for 75 KVA DG set Make: Kirloskar (Fire fighting pump house Tunir and Aradhana Bldg DG-2) complete all as specified and as directed by Engr-in-charge.
All as per item No. 1.00 here-in-before but for 62.5 KVA DG set Make: Kirloskar and Cummins (Common, Chukar-III squardon, Bldg No 515, 385 & 388 (opposite of EMR workshop) and NAI Bldg No 573 DG-4) complete all as specified and as directed by Engr-in-charge.
All as per item No. 1.00 here-in-before but for 50 KVA DG set Make: Kirloskar (Chunnabhatti pump house DG -1) complete all as specified and as directed by Engr-in-charge.
All as per item No. 1.00 here-in-before but for 30 KVA DG set Make: Cummins (Volna Tower, Mora gate, Sub station 'B' security light DG set, Sub station 'K' security light DG set, Mangera sub station security light DG set & Type III Md Accn NAD Colony DG-6) complete all as specified and as directed by Engr-in-charge.
All as per item No. 1.00 here-in-before but for 15 KVA DG set Make: Kirloskar (RMSF ECRW Area (NAI) Chunnabhatti, RMSF ERC Area (NAI Office area), FODC & Tunir 'K' sub station DG-4) complete all as specified and as directed by Engr-in-charge.
All as per item No. 1.00 here-in-before but for 10 KVA DG set Make: Kirloskar (Near NHK Sewage s/pump Room & Near chuunnabhatti S/Pump Room DG-2) complete all as specified and as directed by Engr-in-charge.
Supply only following filters for 750 KVA Cummins make DG set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 500 KVA Kirloskar make DG set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 400 KVA Kirloskar make DG Set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 380 KVA Cummins make DG Set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 250 KVA KOEL & Crompton Greaves make DG Set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 200 KVA Kirloskar make DG Set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 180 KVA Cummins make DG Set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 160 KVA Kirloskar make DG Set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 125 KVA Kirloskar make DG Set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 110 KVA Kirloskar make DG Set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 82.5 KVA Cummins make DG Set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 75KVA Kirloskar make DG Set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 62.5 KVA Kirloskar make DG Set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 50 KVA Kirloskar make DG Set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 30 KVA Cummins make DG Set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 15 KVA Kirloskar make DG Set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following filters for 10 KVA Kirloskar make DG Set complete all as specified and as directed by Engr-in-charge.
Fuel filters
Oil filters
Bypass oil filters
Water filters
Air filters
Supply only following belts for 750 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 500 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 400 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 380 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 250 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 200 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 180 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 160 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 125 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 110 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 82.5 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 75 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 62.5 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 50 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 30 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 15 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only following belts for 10 KVA DG Set complete all as specified and as directed by Engr-in-charge.
Fan belt for radiator
Belt for battery alternator
Belt for water pump
Supply only water safety control complete all as specified and as directed by Engr-in-charge.
Supply only lab oil safety control complete all as specified and as directed by Engr-in-charge.
Supply only ON-OFF coil / shut down coil complete all as specified and as directed by Engr-in-charge.
Draining out the old sludge oil from the DG set and replace with new oil complete all as specified and as directed by Engr-in-charge. Note: Draining out of oil shall be done twice in year each time refilling/Top up.
Supply and fix for industrial battery of capacity suitable for 62.5 to 750 KVA DG sets heavy duty, 25 plates including removing existing unserviceable battery from existing places and cleaning of battery terminals and clamps properly and refixed and reconnected complete all as specified and as directed by Engr-in-charge.
Battery of 12 volt, 180 AH
Battery of 12 volt, 150 AH
Battery of 12 volt, 100 AH
Battery of 12 volt, 90 AH
Servicing of AMF panel suitable for 15 KVA DG set to750 KVA DG set including cleaning properly with blower, checking of control wiring, replacement of burnt out/ damaged wiring connections, calibration of control relay, replacement of control fuses/ MCBs complete all as specified and as directed by Engr-in-charge. Note: Spare parts shall be measured and paid separately in respective item of this schedule if required.
Supply only LED type indicator indication lamps (R,Y,B) complete all as specified and as directed by Engr-in-charge.
Supply only push buttons with element complete all as specified and as directed by Engr-in-charge.
Supply only control relay 9/11 pin 12 /24 volt DC of suitable for 62.5 KVA to 125 KVA DG set complete all as specified and as directed by Engr-in-charge.
Supply only bar primary CT of ratio upto 150 / 5A burdan complete all as specified and as directed by Engr-in-charge.
Supply only bar primary CT of ratio upto 400/ 5A burdan complete all as specified and as directed by Engr-in-charge.
Supply only bar primary CT of ratio upto 600/ 5A burdan complete all as specified and as directed by Engr-in-charge.
Supply only bar primary CT of ratio upto 1000/ 5A burdan complete all as specified and as directed by Engr-in-charge.
Supply only HRC fuse 200 Amps complete all as specified and as directed by Engr-in-charge.
Supply only PVC insulated and unsheathed singal core multi strandred copper cable of size 4 sqmm for control wiring complete all as specified and as directed by Engr-in-charge.
Supply only PVC insulated and unsheathed singal core multistrandred copper cable of size 2.5 sqmm for control wiring complete all as specified and as directed by Engr-in-charge.
Supply only PVC insulated and unsheathed singal core multistrandred copper cable of size 1.5 sqmm for control wiring complete all as specified and as directed by Engr-in-charge.
Supply only excitation coil for 250 KVA DG set complete all as specified and as directed by Engr-in-charge.
Supply only AVR card for 750 KVA DG set complete all as specified and as directed by Engr-in-charge.
Material and labour for servicing of turbo charger including replacement of turbo charger kit for capacity upto 750 KVA DG set complete all as specified and as directed by Engr-in-charge.
Material and labour in servicing of self starter 24 Volt DC for self starter upto110 KVA DG set, dismantling and replacement of solenoid field coils, cleaning the cummulator strips including replacing the bearing, bends pinion re-assembling, connecting and testing complete all as specified and as directed by Engr-in-charge.
All as per item No. 73.00 here-in-before but for capacity up to 250 KVA DG set complete all as specified and as directed by Engr-in-charge.
All as per item No. 73.00 here-in-before but for capacity up to 400 KVA DG set complete all as specified and as directed by Engr-in-charge.
All as per item No. 73.00 here-in-before but for capacity up to 750 KVA DG set complete all as specified and as directed by Engr-in-charge.
Material and labour in repairs of fuel pump for aquastic DG set for capacity upto 110 KVA complete all as specified and as directed by Engr-in-charge.
All as per item No. 77.00 here-in-before but for capacity up to 250 KVA DG set complete all as specified and as directed by Engr-in-charge.
All as per item No. 77.00 here-in-before but for capacity upto 400 KVA DG set complete all as specified and as directed by Engr-in-charge.
All as per item No. 77.00 here-in-before but for capacity upto 750 KVA DG set complete all as specified and as directed by Engr-in-charge.
Disconnecting the alternator from the engine of upto capacity 110 KVA by removing the coupling and outgoing cable transporting the alternator to authorized maintenance service center for repairs, cleaning the armature, applying one coat of varnish and heating and assembling the alternator at workshop and testing at NO load, transporting the same to the site, re-connecting the alternator to the engine after proper alignment including testing and commissioning complete all as specified and as directed by Engr-in-charge.
All as per item No. 81.00 here-in-before but for capacity upto 250 KVA DG sets complete all as specified and as directed by Engr-in-charge.
All as per item No. 81.00 here-in-before but for capacity upto 400 KVA DG sets complete all as specified and as directed by Engr-in-charge.
All as per item No. 81.00 here-in-before but for capacity upto 750 KVA DG sets complete all as specified and as directed by Engr-in-charge.
Draining out the water from engine of capacity upto 110 KVA radiator, dismantling the leaking radiator assembly from the engine body, transporting to workshop, cutting the bottom chambers, repairing the damaged pipes, brazing the leaking portions, descaling/ clearing all the blocked pipes including repairing the fins, brazing the bottom chambers, testing the radiator for leakages, transporting the same to the site and re-fixing and testing complete all as specified and as directed by Engr-in-charge.
All as per item No. 85.00 here-in-before but upto capacity 250 KVA DG sets complete all as specified and as directed by Engr-in-charge.
All as per item No. 85.00 here-in-before but upto capacity 400 KVA DG sets complete all as specified and as directed by Engr-in-charge.
All as per item No. 85.00 here-in-before but upto capacity 750 KVA DG sets complete all as specified and as directed by Engr-in-charge.
Material and labour including taking down carefully old rusted silencer and exhaust pipe upto 250 KVA from engine scraping and cleaning in side and out side applying one coat of zink primer for out side silencer pipe and providing self adjestive asbasto rope 12mm dia from engine to exhaust pipe and painting with 2 coats of syenthetic enameled paint for expose portion of exhaust complete all as specified and as directed by Engr-in-charge.
All as per item No. 89.00 here-in-before but for capacity upto 750 KVA DG sets complete all as specified and as directed by Engr-in-charge.
Material and labour for scraping the peeled paint of DG set, preparing the surfaces, cleaning the dust and dirt etc., of (alternator and engine) applying 2 coats of synthetic enamel paint of approved shade and writing of MES/SM No on the set of capacity upto 110 KVA complete all as specified and as directed by Engr-in-charge.
All as per item No. 91.00 here-in-before but for capacity up to 250 KVA DG sets complete all as specified and as directed by Engr-in-charge.
All as per itemNo. 91.00 here-in-before but for capacity upto 400 KVA DG sets complete all as specified and as directed by Engr-in-charge.
All as per item No. 91.00 here-in-before but for capacity upto 750 KVA DG sets complete all as specified and as directed by Engr-in-charge.
Supply olny solenoid switch 12 Volt DC complete all as specified and as directed by Engr-in-charge.
Supply only battery terminal heavy duty made of brass with nut and bolt including washers suitable for 12 volt DC battary complete all as specified and as directed by Engr-in-charge.
Supply only radiator hose pipe as per existing set for 110 KVA DG set complete all as specified and as directed by Engr-in-charge.
All as per item No. 97.00 here-in-before but for capacity upto 250 KVA DG sets complete all as specified and as directed by Engr-in-charge.
All as per item No. 97.00 here-in-before but for capacity upto 400 KVA DG sets complete all as specified and as directed by Engr-in-charge.
All as per item No. 97.00 here-in-before but for capacity upto 750 KVA DG sets complete all as specified and as directed by Engr-in-charge.
Supply only door hinges assembly for aquastic DG set complete all as specified and as directed by Engr-in-charge.
Supply only heavy duty automatic electronic battery charger suitable for 12 /24 Volt DC complete all as specified and as directed by Engr-in-charge.
Supply only ignition switch for capacity upto 750, 500, 250, 125, 82.5 KVA DG set complete all as specified and as directed by Engr-in-charge.
Supply only solenoid switch 24 Volt DC for 10 to 750 KVA DG set as per existing complete all as specified and as directed by Engr-in-charge.
Supply only coolant premix as manufafacture recommendations and required for top up for accostic DG set complete all as specified and as directed by Engr-in-charge.
Supply only fuel pipes with benjo bolt and washers for fuel pipe upto capacity 110 KVA DG set complete all as specified and as directed by Engr-in-charge.
All as per item No. 106.00 here-in-before but for capacity upto 250 KVA DG sets complete all as specified and as directed by Engr-in-charge.
All as per item No. 106.00 here-in-before but for capacity upto 400 KVA DG sets complete all as specified and as directed by Engr-in-charge.
All as per item No. 106.00 here-in-before but for capacity upto 750 KVA DG sets complete all as specified and as directed by Engr-in-charge.
Supply only water coolant hose set suitable upto 110 KVA DG set complete all as specified and as directed by Engr-in-charge.
All as per item No. 110.00 here-in-before but for capacity upto 250 KVA DG sets complete all as specified and as directed by Engr-in-charge.
All as per item No. 110.00 here-in-before but for capacity upto 400 KVA DG sets complete all as specified and as directed by Engr-in-charge.
All as per item No. 110.00 here-in-before but for capacity upto 750 KVA DG sets complete all as specified and as directed by Engr-in-charge.
Supply only fuel hose set suitable for capacity upto 110 KVA DG set complete all as specified and as directed by Engr-in-charge.
All as per item No. 114.00 here-in-before but for capacity upto 250 KVA DG sets complete all as specified and as directed by Engr-in-charge.
All as per item No. 114.00 here-in-before but for capacity upto 400 KVA DG sets complete all as specified and as directed by Engr-in-charge.
All as per item No. 114.00 here-in-before but for capacity upto 750 KVA DG sets complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of MCB SP 6 Amps AC/DC complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of LED type indicator complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of contactor 4 pole 165 Amp coil voltage 230 volt AC complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of contactor type ML-4 complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of contactor type ML-2 complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of change over switch 100 Amps 4 pole as par existing complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs onload change over switch complete in sheet steel enclosure and connecting up, mounting on wall / floor of rating 400 Amps TPN 415 Volts complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of MCB type change over switch 4 pole 63 Amps complete all as specified and as directed by Engr-in-charge.
Servicing of DG manual panel upto 110 KVA DG set including cleaning properly with blower, checking of control wiring, replacement of burnt out/ damaged wiring connections, replacement of control fuses/ MCBs complete all as specified and as directed by Engr-in-charge. Note: Spare parts shall be measured and paid separately in respective item of this schedule if required.
All as per item No. 127.00 here-in-before but upto 250 KVA DG set complete all as specified and as directed by Engr-in-charge.
All as per item No. 127.00 here-in-before but upto 400 KVA DG set complete all as specified and as directed by Engr-in-charge.
All as per item No. 127.00 here-in-before but upto 750 KVA DG set complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of temperature gauge complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of oil pressure gauge 0-10 bar complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of digital frequency meter complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of DC Voltmeter 0 to 30 volt complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of DC ammeter 0 to 20 Amp complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of excitation coil for 75 KVA DG set complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement oil feed pump for aquastic DG set for capacity 15 to 75 KVA complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of alternator for battary charging 12/24 volt DC complete all as specified and as directed by Engr-in-charge.
Material and labour for scraping the peeled paint of DG set, preparing the surfaces, cleaning the dust and dirt etc., of (alternator and engine) applying 2 coats of synthetic enamel paint over a coat of red oxide of approved shade and sign writing of SM/ MES No on the set of capacity 75 KVA complete all as specified and as directed by Engr-in-charge.
All as per item No. 139.00 here-in-before but for 10 KVA to 750 KVA DG set complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of solenoid switch 12 Volt DC complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of stopping relay 24 volt DC complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement anti-vibrating pad suitable for 15 to 40 kVA DG set complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of ignition switch for capacity upto 75 KVA DG set complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of coolant as required for top up complete all as specified and as directed by Engr-in-charge.
Material and labour for refilling of distilled water for top up battery 12 volt DC complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement radiator hose pipe as per existing set of 2 complete all as specified and as directed by Engr-in-charge.
Material and labour in replacment of door lock assembly with key for aquastic DG set complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of heavy duty automatic electronic battery charger suitable for 12/24 Volt DC complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of solenoid coil for capacity upto 75 KVA DG set complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of rubber coupling with nuts, bolts and washer in between alternator and engine upto 75 KVA DG set complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement of battery lead with lug as per existing length and size for capacity upto 110 KVA DG set complete all as specified and as directed by Engr-in-charge.
All as per item No. 152.00 here-in-before but for capacity upto 250 KVA DG set.
All as per item No. 152.00 here-in-before but for capacity upto 400 KVA DG set.
All as per item No. 152.00 here-in-before but for capacity upto 750 KVA DG set.
Material and labour for testing of APFC panel for proper functioning in manual and auto mode, re-wiring the burnt out wires and replacing the unserviceable spares and testing complete all as specified and as directed by Engr-in-charge. Note: Spares like power capacitors, load managers, push button, contactors, ammeter, voltmeter, MCBs will be measured and paid separately under respective item of schedule.
Material and labour in replacement of genset controller for 75 KVA DG set complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement water pump of capacity 75 KVA for DG set complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement water pump of capacity upto 125 KVA for DG set complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement water pump of capacity upto 250 KVA for DG set complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement water pump of capacity upto 400 KVA for DG set complete all as specified and as directed by Engr-in-charge.
Material and labour in replacement water pump of capacity upto 750 KVA for DG set complete all as specified and as directed by Engr-in-charge.
D.N.PATIL
Atul Enterprises
Radha Engineering Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .