Tender Value
₹39.1 L
EMD Value
₹78,300
Closing Date
28 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS Rajouri
SPL REPAIR TO DEFECTIVE OH LT LINE AND PROVN OF GEYSER AT NAUSHERA UNDER AGE EM OF GE 862 EWS
2024_MES_685591_1
GER-71/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 862 EWS Rajouri
As per NIT
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹78,300
Yes
15 Jan 2025
25 Nov 2024
30 Dec 2024
25 Nov 2024
28 Dec 2024
10 Dec 2024
25 Nov 2024 - 5 Dec 2024
Amount
Dismantling of overhead ACSR conductor of any size including removing of PG clamps jumpering etc and removing unserviceable conductor from site, complete all as specified and directed. Note:- Underground XLPE cable shall be provided here-in- after from Srl item no 02.00 to 10.00 against ACSR conductor
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 150 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, brick cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 120 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, brick cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, brick cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, brick cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, brick cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, brick cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply, install, testing and commissioning LT Feeder piller box outdoor type of size 1500mmx1500mmx600mm suitable for working on 415 volts AC, 3 phase, 4 wire, 50 Hz, outdoor cubical type and tested at CPRI, outer shell be made out of 3.15mm thick CRCA sheet & MS angle iron frame duly powder coated of size 50 X 50 X 6 mm frame , with front & back open, double door system lockable, inner shell be made out of 2.0 mm thick CRCA sheet and completely vermin & dust proof entry holes for incoming & outgoing cables as approved by GE. Panel shall have bus bar chamber and switch gear compartment, hinged door with rubber gasket, earthing terminals, and consisting of following, Compete all as specified and directed:-.
Incomer MCCB (a) MCCB, 250 Amp, 4 Pole, 50 Hz, 415 V, having rupturing capacity 35 KA-01 No as incoming (thermal magnetic) release and adjustable on load. Outgoing MCCB (a) MCCB, 200 Amp, 4 Pole, 50 Hz, 415 V hanving rupturing capacity 35 KA-01 No as out going (thermal magnetic) release and adjustable on load (b) MCCB, 100 Amp, 4 Pole, 50 Hz, 415 V hanving rupturing capacity 25 KA-04 No as out going (thermal magnetic) release and adjustable on load (c) MCCB, 4 pole 40 amps -02 Nos (d) Digital voltmeter (0-500) & Digital Ammeter (0-100) Amps with suitable CTs. (e) LED phase indication lamps RYB-01 set. (f) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 volts grade and cupper Bus Bar including painting etc. (g) Copper bus bar, TPN, 400 Amp rating 4 Nos. Notes : (i) Rates are deemed to be inclusive of PCC platform of suitable size of 45 cm height and 04 Nos legs of 50mm x 50mmx6mm for fixing the panel (ii) MCCB & MCB shall be fixed in suitable sheet metal enclouser made up of 3.15mm thick CRCA sheet. (iii) Danger notice plate (02 Nos) LT size 20cm x 15 cm shall be fixed on the panel (iv) Panel shall be from CPRI approved make.(v) Make of panel and drawing shall be got approved from GE before placing order for procurement
Supply, install, testing and commissioning LT Feeder piller box outdoor type of size 1500mmx1500mmx600mm suitable for working on 415 volts AC, 3 phase, 4 wire, 50 Hz, outdoor cubical type and tested at CPRI, outer shell be made out of 3.15mm thick CRCA sheet & MS angle iron frame duly powder coated of size 50 X 50 X 6 mm frame, with front & back open, double door system lockable, inner shell be made out of 2.0 mm thick CRCA sheet and completely vermin & dust proof entry holes for incoming & outgoing cables as approved by GE. Panel shall have bus bar chamber and switch gear compartment, hinged door with rubber gasket, earthing terminals, and consisting of following, Compete all as specified and directed.
Incoming MCCB (a) MCCB, 160 Amp, 4 Pole, 50 Hz, 415 V, having rupturing capacity 35 KA-01 No as incoming (thermal magnetic) release and adjustable on load Outgoing MCCB (a) MCCB, 100 Amp, 4 Pole, 50 Hz, 415 V, having rupturing capacity 25 KA-01 No as outgoing (thermal magnetic) release and adjustable on load (b) MCCB, 63Amps, 50 Hz, 415 V having rupturing capacity 25 KA-02 No as outgoing (thermal magnetic) release and adjustable on load (c) MCB SPN 63 amps -05 Nos (d) Digital voltmeter (0-500) & Digital Ammeter (0-100) amps with suitable CTs (e) LED phase indication lamps RYB-01 Set (f) Internal wiring with PVC insulated copper conductor multistranded cable 1100 volts grade and cupper Bus Bar including painting etc. (g) Copper bus bar, TPN 600 amp rating-04 Nos. Notes : (i) Rates are deemed to be inclusive of PCC platform of suitable size of 45 cm height and 04 Nos legs of 50mm x 50mmx6mm for fixing the panel (ii) MCCB & MCB shall be fixed in suitable sheet metal enclouser made up of 3.15mm thick CRCA sheet. (iii) Danger notice plate (02 Nos) LT size 20cm x 15 cm shall be fixed on the panel (iv) Panel shall be from CPRI approved make.(v) Make of panel and drawing shall be got approved from GE before placing order for procurement
Supply, install, testing and commissioning LT Feeder piller box outboor type of size 1500mmx1500mmx600mm suitable for working on 415 volts, 3 phase, 4 wire, 50 Hz AC, outdoor cubical type, and tested at CPRI, outer shell be made out of 3.15mm thick CRCA sheet & MS angle iron frame duly powder coated of size 50 X 50 X 6 mm frame, with front & back open double door system lockable, inner shell be made out of 2.0 mm thick CRCA sheet and completely vermin & dust proof entry holes for incoming & outgoing cables as approved by GE. Panel shall have bus bar chamber and switch gear compartment, hinged door with rubber gasket, earthing terminals, and consisting of following, Compete all as specified and directed.
Incomer MCCB (a) MCCB, 200 Amp, 4 Pole, 50 Hz, 415 V, having rupturing capacity 35 KA-01 No as incoming (thermal magnetic) release and adjustable on load Outgoing MCCB (a) MCCB, 100 Amp, 4 Pole, 50 Hz, 415 hanving rupturing capacity 25 KA-02 No as out going (thermal magnetic) release and adjustable on load (b) MCCB, 63 Amp, 4 Pole, 50 Hz, 415 V hanving rupturing capacity 25 KA-01 No as out going (thermal magnetic) release and adjustable on load (c) MCB, SPN, 63 amps - 2 Nos (d) Digital voltmeter (0-500) & Digital ammeter (0-100) amps with suitable CTs. (e) LED phase indication lamps RYB-01 set. (f) Internal wiring with PVC insulated copper conductor multistranded cable 1100 volts grade and cupper bus bar including painting. (g) Copper bus bar, TPN 400 amp rating-04 Nos Notes : (i) Rates are deemed to be inclusive of PCC platform of suitable size of 45 cm height and 04 Nos legs of 50mm x 50mmx6mm & 60 CM height for fixing the panel (ii) MCCB & MCB shall be fixed in suitable sheet metal enclouser made up of 3.15mm thick CRCA sheet. (iii) Danger notice plate (02 Nos) LT size 20cm x 15 cm shall be fixed on the panel (iv) Panel shall be from CPRI approved make.(v) Make of panel and drawing shall be got approved from GE before placing order for procurement
Supply, install, testing and commissioning LT Feeder piller box outdoor type of size 1500mmx1500mmx600mm suitable for working on 415 volts, 3 phase, 4 wire, 50 Hz AC, outdoor cubical type, and tested at CPRI, outer shell be made out of 3.15mm thick CRCA sheet & MS angle iron frame duly powder coated of size 50 X 50 X 6 mm frame, with front & back open, double door system lockable, inner shell be made out of 2.0 mm thick CRCA sheet and completely vermin & dust proof entry holes for incoming & outgoing cables as approved by GE. Panel shall have bus bar chamber and switch gear compartment, hinged door with rubber gasket, earthing terminals, and consisting of following, Compete all as specified and directed.
Incomer MCCB (a) MCCB, 200 Amp, 4 Pole, 50 Hz, 415 V, having rupturing capacity 35 KA-01 No as incoming (thermal magnetic) release and adjustable on load. Outgoing MCCB (a) MCCB, 100 Amp, 4 Pole, 50 Hz, 415 hanving rupturing capacity 25 KA-03 No as out going (thermal magnetic) release and adjustable on load (b) MCCB, 63 Amp, 4 Pole, 50 Hz, 415 V hanving rupturing capacity 25 KA-01 No as out going (thermal magnetic) release and adjustable on load (c) MCB, SPN, 63Amps -2 Nos. (d) Digital voltmeter (0-500) & Digital ammeter (0-100) amps with suitable CTs. (e) LED phase indication lamps RYB-01 set. (f) Internal wiring with PVC insulated copper conductor multistranded cable 1100 volts grade and cupper bus bar including painting. (g) Copper bus bar, TNP 400 amp rating - 04 Nos Notes : (i) Rates are deemed to be inclusive of PCC platform of suitable size of 45 cm height and 04 Nos legs of 50mm x 50mm x 6mm & 60 cm heigh for fixing the panel (ii) MCCB & MCB shall be fixed in suitable sheet metal enclouser made up of 3.15mm thick CRCA sheet. (iii) Danger notice plate (02 Nos) LT size 20cm x 15 cm shall be fixed on the panel (iv) Panel shall be from CPRI approved make.(v) Make of panel and drawing shall be got approved from GE before placing order for procurement
S&F for FRP looping box/Junction box of size 300x250x150 with aluminium bus bar (04 Nos) 63 Amps capacity mounted on epoxy insulator weather proof, comprising of MCB SP 6 Amps, ISI marked 240 V, 'C' series/curves complete with including providing GI calmps 40x6mm, nuts bolts etc suitable for fixing on PCC pole/wall etc and making connection with cable & thimble of suitable size after taking down old unserviceable looping box of any type complete all as specified and directed.
S&F for copper conductor cable, PVC insulated, sheathed flexible, multistranded ISI marked 1100 volts grade 2 core 1.5 sqmm and including connection of security light to junction box and testing, complete all as specified and directed.
M&L for street light bracket made out of 32mm bore light grade GI pipe 1.2 m long bent to shape 120 degree and duly fixed alongwith existing pole/ bldg with the help of 2 nos of MS clamp of size 32x3mm including suitable size of nuts, bolts and washer etc, complete all as specified and directed
M&Lfor earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including 25X4mm thick galvanised iron strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mm c/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:-Earthwork, Earth strip and protection pipe upto board is included in the rate quoted)
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m in depth in soft/loose soil, for foundation, etc, or for shafts, wells, drain, pipes, laying of cable/pipes, foundation of poles/stays etc n.exc 10 Sqm on plan and getting out, complete, all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick ,complete all as specified and as directed.
Removing excavated material, not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting poin, complete all as specified and directed.
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable, complete all as specified and as directed (Note: Punned thickness of sand shall be measured and paid).
S&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mmx115mmx75mm over the cable abutting each other, complete all as specified and as directed.
S&L in for 50mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls with clampss, nuts, bots for protection of cable, complete all as specified and directed.
S&L in for 80mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls with clampss, nuts, bots for protection of cable, complete all as specified and directed.
S&F in repair for LED bldg street light fitting 35 watt dusk and down type, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish prismatic polycarbonate cover with IP 65/66 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper able from connector to fitting and removing old unserviceable item, complete all as specified and directed
M&L for storage water heater (geyser) 5 star rating as per BEE norms electricall operated suitable for 230 volts, 50hz, AC supply system complete with porcelain/ glass coated insulated heating element, copper tank of 2KW capacity 25 litre, complete with all accessories such as safety valve, thermostat, NRV, complete all as specified and directed by Engr-in-Charge.
M&L for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly, complete all as specified and directed. (Note : - 02 run of 4 sqmm single core copper conductor cable and 01 run of 4 sqmm single core copper conductor and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
M&L for single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole 230 volt MCB 20 amps, complete all as specified and directed.
S&F for MCB single pole, 240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, 'C' curve including providing thimble for out going cables, complete all as specified and directed.
M&L for 15 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors including taking down existing GI tubes complete all as specifed and directed.
S&F of stop cock, with iron wheel head, complete with suitable for 15mm bore pipe, screwed both side ends for GI pipe or unions and fixed in size 15mm dia, complete all as specified and directed
S&F for 15mm bore bib tap cast copper alloy, chromium plated with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule, complete all as specified and directed.
narayan construction (BID ID -3201066)
KRISHNA ENGINEERING ENTERPRISES (BID ID -3190669)
m/s vishkarma construction (BID ID -3200760)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .