Tender Value
Refer Docs
EMD Value
₹3,991
Closing Date
9 Apr 2021, 2:00 pmClosed
Director, DSCI
Delhi State Cancer Institute Dilshad Garden Delhi
Repair of leakage /seepage from Pediatrics ward (Female) toilet, replacement of old rusted pipe at hospital and Dharamshala Building and other miscellaneous civil repairs at main kitchen area at Delhi State Cancer Institute(East) Dilshad Garden, Delh
2021_DSCI_202575_1
DSCI-H012(12)/2/2019
Open Tender
Miscellaneous Works
Item Rate
15 days
Delhi State Cancer Institute Dilshad Garden Delhi
As per eligibility creteria of e-tender
7 documents required · 7 mandatory
₹0
₹3,991
Yes
13 Apr 2021
1 Apr 2021
9 Apr 2021
1 Apr 2021
9 Apr 2021
1 Apr 2021
Amount
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (i/c equivalent designmix)
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :
1:3 (1 cement: 3 fine sand)
Providing and laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, piers,abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing :1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. ealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N.Softening point of membrane not less than 150°C. with ASTM, D - 5147.The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade
Area of slab upto 0.50 sqm
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including all lifts involved
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
32 mm nominal outer dia Pipes
40 mm nominal outer dia Pipes
50 mm nominal outer dia Pipes
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete
25 to 40 mm nominal bore
50 to 80 mm nominal bore
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.
25 mm nominal bore, 152mm long, weighing not less than 440 gms
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :
15 mm to 40 mm nominal bore
Providing & fixing soil,waste & vent pipes of PRINCE/SUPREME/KISSAN make unplasticised rigid PVC pipe as per is 4985 of 6 kg/sq cm working pressure i/c fixing with adhesive and all joints to be covered with M-seal complete as per direction of Engineer-in-charge
90 mm outer diameter
Providing & fixing unplasticised - PVC moulded fittings/ accessories for unplasticised rigid PVC pipes of PRINCE/SUPREME/KISSAN make as per is 4985 of 6 kg/sq cm working pressure i/c fixing with adhesive and all joints to be covered with M-seal complete as per direction of Engineer-in-charge Self ceansing trap/floor
90 mm outer diameter
Providing & fixing glass mosaic files of brand approved by engineer in charge. The colors/ blends with size (11.5 mmx11.5mm x 4mm as required upto 10 m height).The glass mosaic tiles to be fixed on the wall & curved surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge:
Dismantling and re-fixing vitreous china dual purpose wall mounted closet suitable (all ready available )for use as squatting pan wall mounted water closetlid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40mm flush bend, 20 mm over flow pipe, with specials of standardmake and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Ball valve (Handle valve) of approved quality : This includes jointing with one step CPVC solvent cement testing of joints complete as per direction of Engineer in Charge.
32 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) Union of approved quality : This includes jointing with one step CPVC solvent cement testing of joints complete as per direction of Engineer in Charge.
32 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
Providing and fixing CPVC Tank nipple /Tank connector of approved quality : This includes jointing with one step CPVC solvent cement testing of joints complete as per direction of Engineer in Charge.
40 mm dia nominal bore
Credit for old dismentled MS scrap received from the site.
vinay shanker
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .