COMPREHENSIVE ANNUAL MAINTENANCE CONTRACT OF THE EQUIPMENT INSTALLED AT HIGH CONTAINMENT FACILITY, DRDE GWALIOR
2020_DRDO_602702_1
CCE(EN)/DEL/AMC-01/20-21/9118
Limited
Miscellaneous Works
Item Rate
360 days
Gwalior
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
CCE RnD Estates, North
₹42,400
Yes
5 Jan 2021
14 Dec 2020
31 Dec 2020
14 Dec 2020
30 Dec 2020
18 Dec 2020
Amount
Annual Maintenance of the equipments installed in HC Facility at DRDE, Gwalior comprising of the following and mandatory servicing through OEM at least once during the currency of contract and providing servicing atleast once every quarter and on breakdown call or complaint by the user. In case OEM doesn't provide repair/servicing/maintenance cover, prior permission to be obtained from Engineer-in-Charge to get the same done through authorized dealer or any other service provider subject to approval of Enginner-in-Charge. The scope is comprehensive and nothing extra shall be payable beyond the quoted rates :-
BIO-SAFETY CABINETS
Class II, Type B1, Vertical Laminar Flow Biological saftey Cabinets 70% air exhaust throw house exhaust fan and 30% air recirculating by internal blower, Model No. NCB-C4, Make - Baker and fume hoom Make: Lab excel.
Class II, Type A or Type B3 Vertical flow Biological Saftey Cabinets 100% air exhaust throw house exhaust fan, Model No. - SG403, Make-Baker and Isolators Make: Germany
Auto-clave Horizontal / Vertical
Barrier Autoclave, PLC Based (Pressure type, double door Chamber size 600x600x1200 mm Working Pressure 1.26 Kg/sq cm Chamber Pressure 1.90 Kg/Sq cm Jacket Pressure 2.60 Kg/Sq cm Direct Steam Pressure 2.10 Kg/Sq cm Heating Load 18 KW/ 3Phase/ 440 V Connected Load 2.6KW Make Yorko
Barrier Autoclave Steri Horizontal Rectangular Steam Sterilizer (Pressure type, double door) Chamber Size Working Pressure 1.26 Kg/Sq cm Chamber Pressure 1.90 Kg/Sq cm Jacket pressure 2.60 Kg/Sq cm Heating Load 0.6 KW / 3Phase / 440V Make Yorko
Vertical Autoclave (Steri Vertical Cylindrical Steam Sterilizer) (Cylindrical type) Chamber Size 160 x 240 mm Working Pressure 1.26 Kg/Sq cm Chamber Pressure 1.90 Kg/Sq cm Jacket Pressure 2.60 Kg/Sq cm Make Yorko
Ethylene Oxide Autoclave
(Cyclomatic Operation) Model No. EO-RA-DD-O-CY-DSP-HW-DS Chamber Size 450x450x900 mm Working Pressure 1.2 Kg/Sq cm Jacket Pressure 2.4 Kg/Sq cm Chamber Pressure 1.8 Kg/Sq cm Direct Steam Pressure 2.1 Kg/Sq cm Connected Load 2.6 KW/ 3Phase / 440V Make Machine Fabric
Uptel India
CLYMATE CONTROL
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .