Tender Value
₹33.0 Cr
EMD Value
₹66.1 L
Closing Date
31 Jul 2026, 3:00 pm
Supply installation testing and commissioning of S&T material in connection with following work:-Replacement of existing PI with new EI system at 9 stations in Nagda- Bhopal Section of Ratlam division. (Akodia, Shujalpur, Kalapipal, Jabri, Parbati, Baktal, Sehore, Panchawan, Bakanian Bhaunri)
SnT_RTM_W_26_15_Signal
SnT_RTM_W_26_15_Signal
Open
24 Months
Ratlam, Madhya Pradesh
₹0
₹66.1 L
2 Jul 2026
2 Jul 2026
17 Jul 2026
Item Breakup - SOR-SOR Schedule
3.00 130201.33 for Trouble Shooting and repair of hardware and software for the EI system should be supplied for stations as per schedule item 1 above. This includes tools required for EI maintenance sorts of crimping, insertion, removal. General purpose tools like screwdrivers, spanners, PCB extractor, temp. Controlled soldering iron, wire cutter, nose pliers, etc. Measuring instruments with carrying case/ holders/ cabinet for technicians/ J.E. for testing, Maintenance and repair at the site). Each set comprises the following: - 1. Crimping tool for all types of special cable assembly used in EI system. 2. Insertion tool for all types of special cable assembly used in EI system. 3 .Removal tool for all types of special cable assembly used in EI system. 4. Digital multimeter (Fluke 111 or better) 5. Steel cabinet/ Almira, Size: 1980mm height, 915 mm width and 485 mm depth (Godrej Make/Jalaram) of good quality to store tools, spare cards and documents.6. Clamp Earth Tester. 7. Clamp Current Meter. Data logger system for Railway S&T installation As per spec. IRS: S-
Monitoring Unit (Hardware Configuration as per Annexure) with UPS minimum 06 hrs battery backup and required Software tools. This also includes the supply of one no composite computer & printer table (Godrej workstation table) for keeping the Processor module and one no Godrej make operator chair model PCH7001.
9.00 630312.50 ( Godrej work station table & chair model PCH7001 orsuperior ) RATLAM DIVISION-S AND T/WESTERN RLY
50.00 Dia, 4.6 Mtr Length as per IRS: S- 6/81 or Latest & RDSO Drg. No. SA- 24625 (Advance).
50.00 housing multi-unit type for railway signalling suitable for RE area FOUR Aspects. Complete without lenses, lamps and signal transformer as per RDSO Drg.No. SA 23001/A/M Adv. Alt- Sand as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.
10.00 Complete with Post (made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990) Base, Hood, and Cover, etc. as per Drg. No. SA-23840, Signal Number Plate, suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item). Supply of DC Track Circuit Accessories as follows :-
54.00 AC input, 2 to 6/10 V DC Output; as per Specn. No. IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery.
108.00 Circuit on 25 KV 50 Hz AC Electrified Section as per Spec No IRS S 65/1983 with latest amendments.
54.00 disc type 30 ohms as per RDSO Drg. No. SA 20166/M (Adv.) with latest amendments (with Phenolic molded base). Provision of Field accessories of DC Track Circuits
500.00 C.Rly Drg. No.RST 11509 made from fiber glass/SMC/FRP along with terminal blocks.
200.00 Line, Non AC Immunized Relay, Style QN1, 24 V DC, 8F-8B/12F- 4BContact, Code ABCDF/ABCDE Spec: BRS: 930; IRS S 34; IRS S 23.
100.00 Line AC Immunized Relay, Style QNA1, 24 V DC, 8F-8B/12F- 4BContact, Code ABDGH/ABDFH Spec: BRS: 931A; IRS S 34; IRS S 23; IRS S 60-78.
100.00 (QSA3), AC immune, DC neutral line 24V, 12F/4B contacts, complete with plug board, retaining clip and connectors. Conforming to BRS930A, (as applicable) IRS: S34& IRS: S23 or latest RATLAM DIVISION-S AND T/WESTERN RLY
200.00 relay 24V DC, 4F-4B/6F-2B contacts, along with plug board, retaining clip and connectors. Conforming to BRS: 960, IRS: S60, IRS: S34 & IRS: S23. (No of each configuration will be decided by Engineer In-charge).
54.00 ,Line Relay QSPA1, 24V DC, Slow to Pick up AC Immunized, 12F-4B/8F- 4B Contact, Code ABDEJ Spec:BRS:933A ; IRS S 34 ; IRS S 23;IRS S 60-78.
54.00 Neutral ,Track relay, ACI, Style QTA2, 9 Ohm, 2F-1B contact, Code - FGHKX Spec : BRS :939-A & 966 (Appx-F2) & IRS : S-23, S-23,S-34 & 60.
40.00 AC immunize with different ward combinations (Three ward plates to be supplied with each relay). Key ward shall be specified by engineer incharge as per requirement.
18.00 Housing of Various S&T equipments like KLCR, Reset Box, IPS Indication Panel, CA VA Unit for FACS, SP AU for Point Reversal, Crank Handle, Quad Cable Earth Sensing Unit along with Fixing of KLCR (KLCR will be provided by Railway) as per instruction of Site Engineer, Make RITTAL, SANTEL, VERO , PRESIDENT, APC Schneider or similar reputed make
46.00 no. CSTE 5004, 5005, 5006 complete along with fitting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated.
1350.00 as per RDSO Drg No SA-23748 Alt 4 & Spec No IRS S 75/2006 with the latest amendment. The fuse block shall be suitable for round-head type voltage fuses. This also includes the supply of equivalent no of ND type Fuses of 2A capacity as per specification IRS S-78/92.
1450.00 type low voltage cartridge fuse as per Spec No IRS/S/78/92 with latest amendments 2A/4A/6A capacity. RATLAM DIVISION-S AND T/WESTERN RLY
10.00 use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 24 nos. of external Non-Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in signaling circuits. The system shall have 6 cards with a monitoring arrangement of 4 fuses in one card.
27.00 use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 32 nos. of external Non-Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signaling circuits. The system shall have 8 cards with a monitoring arrangement of 4 fuses in one card. Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments
30000.00 less type, 4-wire front entry (Two in-put & Two out-put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply.
7600.00 in thick as per site requirement.
of 10mm/0.0394 in width as per site requirement.
112.00 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement.
1350.00 single potential through screw less terminal block for 6 Sq.mm - 35 Sq.mm , 4 connection points 284- 621/624 or superior, suitable for power cable connection.
45.00 Telephone as per spec No IRS/TC- 79/2000 or with latest amendments.
Extinguisher (capacity 5 kg). ( capacity4.5 kg )
90.00 of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008. RATLAM DIVISION-S AND T/WESTERN RLY
18000.00 made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4.
68.00 SS 304 of size as per Drg. No. DRM/SG/945 dtd 03.03.2011 (Half app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply.
74.00 per WR CSTE Drg No. 6286 Modular Type Cold Rolled MS Full Location Box. It includes Angle frame Relay frame fixture , earthing Rod Drawing Board , Lock etc. as per WR CSTE Drg No. 6286.
9.00 174705.11 multi-core Indoor Cable 60core x 0.6mm Dia conforming to IRS:76/89 (Amd3) or latest.
9.00 183153.70 multi-core Indoor Cable 1mm x 24 mm x 1 mm Dia conforming to IRS:76/89(Amd3) or latest.
5.00 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest.
5.40 strand copper conductors cross section 1x6 Sq.mm.( 85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest.
5.40 136063.55 strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest.
5.40 132505.12 strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89.
11800.00 size width 240/340 mm, height 155/230 internal/external, length 1meter produced of polyolefin with fire protection class K-1 in accordance with DIN 53438 Part-II for laying signaling/telecom cables, channel attachable to each other with male female swallow tail connectors and having a suitable detachable cover, as per RDSO STS/E/cable laying Precise Vol-IV and as per technical specifications. RATLAM DIVISION-S AND T/WESTERN RLY
150.00 HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti- rodent & anti-oxidant and non- flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. . One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End- cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color -Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer.
100.00 (Pt.)-2004 or latest; 100mm dia. (int. Dia) 3.65 mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes.
720.00 room. (5mm thick).
9.00 Industrial, True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, 20A for up to 30 seconds or Superior. Total 60822245.92 Item- 2 B1- Signalling Execution items for replacement of existing PI with new EI at 9 stations. S No. Item No Description of Item Unit Qty Rate Amount Supply, Installation and Commissioning of EI VDU (Visual Display Unit, 4K with all suitable accessories Compatible to El Interlocking in Safe Mode 24x7 at controlling station. The item must comply minimum following specification:- a) Screen Size (Diagonal):- As below b) Resolution :- 4K c) Viewing angle degree: - 178x178 degree d) Brightness :- 500 Nits e) contrast ratio 4000:1 f) Backlit :- Direct LED g) Jack Interface: - HDMI -3 no. 1.2 DP, DVI USB 2.0 -2 no. CI Slot RF In AV In Component In (RCA5 Type) Digital Audio Out RGB In (D-sub 15pin)-PC PC Audio Input RS232C (D-Sub 9pin) RJ45 Stereo mini jack. h) Optical Out :- Available Note: - Screen size will be decided as per instruction of engineer incharge.
27.00 Grade Embedded PC as per RDSO TAN no. STS/E/TAN/3007 dated 2.11.12 or latest. RATLAM DIVISION-S AND T/WESTERN RLY
9.00 133269.46 racks and Power equipment etc. to be done along with the supply of all requisite materials. Earthing shall be in the form of Ring Earth conforming to RDSO specification No. RDSO/SPN/197/2008 (with a min. of 6 maintenance free earth electrodes) & RDSO Drawing issued under Railway Board letter No. 2010/Sig./SGF/EI (Ansaldo) Dated 22.06.11, made using copper rings with earth resistance less than 1 ohm. The earthing shall be maintenance free & earth enhancement compound should be used. The ring earth shall be connected to copper flat of size 25x3 mm in the relay room and IPS room. This copper flat shall be fixed on the wall to the entire breadth of the Relay room and IPS room as an earth bus bar and all earth connections shall be taken from it. A, B, C, & D class protection shall be provided for all EI equipment. Note: - This will also cover the earthing& necessary protection of EI equipment as per details given in the scope of work of Special Condition of Contract and other requirement given in Chapter of tender document & Pre- commissioning check list of EI system.
300.00 for installation, Commissioning, Testing, Repairs & Troubleshooting alteration, design of EI system, as per details given in Special Condition of Contract. (Hard copies of training manuals/ course module to be given to each participant). Design of Miscellaneous diagram consist of Floor Plan of Relay Room , Battery Room, Power Equipment Room, Data logger room, Power Supply Diagrams along with power supply calculation, Earthing Diagram, Power panel diagram, IPS wiring diagram , Auto change over diagram , Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawings (Three copy) for approval.
9.00 submission of Three paper copies for approval. Supply of Circuit Diagrams consisting wiring/Logic diagram, contact analysis, fuse detail, Input/output bit chart, VDU diagram, Interface in AutoCAD in Pen Drive and Six set of Copies after approval
Station RATLAM DIVISION-S AND T/WESTERN RLY Supply of diagrams consist of Floor Plan of Relay Room, Battery Room, Power Equipment Room, Data logger room, Power Supply Diagrams along with power supply calculation, Earthing Diagram, Power panel diagram, IPS wiring diagram, Auto change over diagram, Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawing in original tracing along with AutoCAD in Pen Drive and six set copies after approval.
Station Design and supply of cable courage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in AutoCAD in A3/A4 size. The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways along with PENDRIVE & 4 sets of final approved drawings. This includes designing of cable coreage plan based upon I.P in consultation with engineer-in-charge For small/medium yards.
Station Preparation of Cable Route Plan of buried S & T Cables using Radio Detector 8200 GS or Similar model GPS Model,DGSP and Drone for Per Trench per Km. For existing cables as per the instruction of Engineer in-charge. Submission of Drone Report in Hard Copy 1 set and DGPS output in KMZ File format. (Unit = Per Trench KM)
Kilometre RATLAM DIVISION-S AND T/WESTERN RLY
9.00 commissioning of Data logger complete along with accessories using Contractors' own wiring & fixing materials as per the following configuration. (It includes loading of NETWORKING software, networking of data logger, installation of FEP & Fault diagnosis system). The requisite communication cable/channel for networking will be arranged by Railway. 1024 digital & 32 analog inputs/ 4096 digital & 32 analog inputs. (All the Indoor & outdoor gears wiring in cataloged included in this along with laying 230V supply cable from IPS room,12 core cable from auto change over for monitoring supplied.) Note :- It included logging of all gears as per site incharge. Foundation, Erection & Installation of CLS without route indicator.
50.00 signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any... The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In- Charge at site. It also includes supply of padlock for signal units and cable termination box. X' arms to be provided by the contractor till the signals are introduced. The Item includes cutting of Signal post if required by Site In charge. 2/3/4 aspect signal unit mounted directly on signal post
54.00 equipments i.e. track feed charger, resistance, track relay, battery, PPTC fuses etc., in the Apparatus Case and battery box as per standard practice. Termination of tail cable on M 6 / Screw less terminals WAGO or FINOLEX or similar approved make terminals/ fuse blocks / HRC fuse. Item includes testing /commissioning of track circuit. Complete wiring material (including PPTC fuses) which are not covered in Schedule will be supplied by contractor. (Supply of Track feed battery charger, track feed battery, resistances & 'B' type choke & Track relays will be supplied by Railways / covered in Schedule separately). RATLAM DIVISION-S AND T/WESTERN RLY
54.00 covering points zones also. The item includes provision of continuity bonds of seven strand PVC jacketed wire/ GI wire 8 SWG on rail joints after drilling bond-hole of 7.0/7.1/7.2mm Dia (double bond with sleeves and rail clips are to be provided at each rail joint), insertion of insulated block joint, fixing of Track lead Junction box on MS angle two numbers of size 40X40X5 mm 1200 mm length for track feed/ jumper / track relay ends of track CCTs (as per double TLJB arrangements) and also for fixing jumper cables as per insulation diagram WR Drg No. CSTE/6055 and standard practice, making rail connections through suitable insulated sleeves from Track lead Junction box at TF, jumper & TR end with seven strand PVC jacketed wire /GI wire 8 SWG, rail clips for fixing bond wire on the TLJB as per standard practice, termination of tail cables on bootleg terminals etc. TF/TR wiring shall be fixed on the suitable arrangement on PRC sleepers with the help of hooks. Hooks shall be provided on PRC sleepers with the help of suitable steel bracket. This item also includes fixing & supply of channel pins etc. The item also includes supply of MS angles/ trestles, GI wire 8 SWG / seven strand PVC jacketed wire, hooks, rail clips etc.
162.00 80AH) with contractors' own battery grade sulphuric acid and distilled water with a minimum of two charge-discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per the extant practice of W.Rly & instruction of the Engineer-in- charge. Detailed measurements of initial charging shall be recorded jointly by the contractor & Rly's site-in-charge. RATLAM DIVISION-S AND T/WESTERN RLY
104.00 rail contact) including digging of Point (DP) trench, track crossing, laying of anti-rodent, anti-oxidant & non- flame propagating type Double Walled Corrugated (DWC) pipe as per IS- 14930 part- I or II or latest and all other accessories as per site requirement to be for laying of transmitter and receiver cable. The item also includes installation of EJB / Track side Electronics including foundation & earthing as per OEM's guidelines and Technical requirement & specification with their own material. NOTE: Installation / programming / configuration / commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/RDSO preferably by Authorized representative of OEM.
4.00 axle Counter, wiring from CT rack to Central Evaluator, installation and wiring of the reset box, LV box (if required) and associated power supply wiring. This includes supply of shielded cable of required conductor size for wiring between CT rack to evaluator rack, all other wires, power supply cable and wiring materials. The power supply cable from power room to Central Evaluator should not be less than 10 sq.mm PVC wire. Earthing as per OEM's guidelines & specification with their own material. This also includes painting and writing work on evaluator as per site requirement. NOTE: Installation /programming / configuration / commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/ RDSO preferably by Authorised representative of OEM.
40.00 includes supply of MS sheet box for fixing of KLCR relay along with push button etc. (KLCR will be supplied by Railway).
46.00 Racks Assembly complete including wall supports, scaffolding, 8 way/ARA terminals /Screw less connectors, Tag blocks & other necessary accessories etc. The work shall be done as per approved plan, extant practice on WR & the instruction of Rly engineer at site. RATLAM DIVISION-S AND T/WESTERN RLY
18.00 RDSO/SPN/256/2002 or latest with latest amendments. The basic detector unit shall comprise of 8 channels, for use on signaling circuits of 110V AC/DC and/or 60V/24V/12V DC as ordered by purchaser. If the detector is required for less number of channels, dummy plates shall be provided. For additional requirement add on /expendable cabinet may be used. The voltage specified shall be provided with + 25% and - 10% tolerance.
82.00 commissioning of Fuse changeover system (FACS). This includes the provision of a common Buzzer & indication at the ASM Room & ESM Duty Room and the painting of fuse details. This also includes the fabrication of a frame for the installation of FACS at the Station/ LC gate where the installation of relay racks is not feasible.
90.00 including MS flat for clamp etc. and connection to signalling equipments, lever frames, apparatus cases, signal, relay rack, block instrument, etc. as per technical specification given. This item includes digging of pit in earth 3 M deep & fixing earth electrode pipe, casting of cement concrete enclosure & cover as per RDSO/SPN/ 197/2016.Soiltreatment to be done as per std. practice. This item includes provision of MS Flat, Earth lead wires and Soldering of lead wires. The other end of the wire is to be connected to block equipment, power equipment, cable sheath, and signals etc. as per site requirements. 7strand GI wire shall be used as earth lead wire. Supply of earth electrode is covered in other Item').
90.00 Earth Electrode for Maintenance Free Earth spec of RDSO/SPN/197/2008.
18000.00 connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry.
45.00 cement and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor. RATLAM DIVISION-S AND T/WESTERN RLY
concrete miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).
45.00 guide bunds, around buried type abutments, bridge gaps, trolley refuges, rain bunds if provided, platforms etc. with earth excavated from outside railway boundary entirely arranged by the contractor at his own cost as per RDSO's latest guidelines and specifications and special condition of contract including all leads, royalty, lifts, ascents, descents, crossing of nallahs or any other obstructions. The rates shall include all dressing of bank to final profile, demarcation and setting out of profile, site clearance, removing of shrubs, roots of vegetation growth, heavy grass, benching of existing slope of old bank, all handling/re-handling. Taxes, Octroi and royalty etc. as a complete job. Cut trees shall be property of railways and to be deposited in the railway godown unless specified otherwise in the Special conditions of contract.
180.00 Signaling Gears. One Signalling gear will be all parts of one signal (consisting of CLS unit, Signal post along with base) or lever frame (5 levers set), or one point (consisting of all parts of a mechanical point, point machine, ground connections etc.) or one track circuits (consisting of battery box & other parts of DC Track circuit / AFTC /DAC) or one Block instruments or One Lifting Barrier or One Location Box etc. .This includes the cost of transportation of release materials to store depot or as decided by consignee in charge. This work to be done by contactors with his own vehicle and labour. (Per unit means Per Gear).
9.00 Equipments, relays and relay racks, CT racks, Batteries etc.as per the instructions of Rly Engineer at site & their transportation to nominated depot. This work to be done by contactors with his own vehicle and labour.
500.00 leading up to 1 Km including Loading from Starting point, unloading & Stacking at destination.
74500.00 part thereof RATLAM DIVISION-S AND T/WESTERN RLY Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost
84.00 or CSTE/5074 or SS Location
68.00 CSTE/5074 or SS Location. Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway.
Numbers Fabrication and fixing of SMC sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783-1/2. With latest alterations & as per instructions of Rly engineer at site. Note: SMC sheet will be taken in place of phenolic laminated sheet.
90.00 box board on 03 mm ACP sheet with size 12 x 18 size A3 for location box including pasting of printed/ painted vinyl sheet and lamination (printing/painting of location detail on vinyl sheet covered in schedule item separately).
5000.00 cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m. RATLAM DIVISION-S AND T/WESTERN RLY
360.00 rail flange/ road level and, 0.3 Mtr to 0.6 Mtr wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No. CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed.
90.00 Deep and 0.3 Mtr. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches.
900.00 without damage of surface road using Auger Machine. The bore shall be 150 mm Dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtr long. The HDD with or without HDPE pipe as per direction of Engineer In charge. Note: HDPE pipe supply is taken as separate item. This item also includes cable laying (HDD boring).
26.00 as per instruction of Site Engineer, supplying and filling of sand before and after coiling the cables, covering top of the cable pit with stones and providing brick masonry on all four sides of the cable pit and plastering thereafter.
900.00 with collars in trenches at places of track and road crossings, platform cuttings etc. also for straight cable laying. (Cable laying is covered separately.) RATLAM DIVISION-S AND T/WESTERN RLY
100.00 GI pipes 100 mm Dia (4.5 mm thickness) as per IS 1239 ( Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm Dia hole, or at any other locations as decided by Site Engineer. The GI pipe is to be filled with chattered compound. It includes supply of all material required for fi Xing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The e laying and fi Xing to be done as per RDSO drawings No. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest.
603000.00 cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trucking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of colored plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be daggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.
500.00 cable route marker engraved and painted on both side along the route every 50mm and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker. RATLAM DIVISION-S AND T/WESTERN RLY Installation, Wiring and testing of Integrated Power Supply System. This includes power distribution connection to bus bars and relay racks in the room with contractor's own wiring materials and fabrication and fixing of AC/DC power distribution board made on 8mm thick SMC sheets or any standard make with connections suitable for 32 A. Wiring to be done considering site requirement, depending upon the load with suitable wires, lugs & glands as per instructions of Engineer-in-charge. The work includes installation of ELD's, fixing & wiring of change over switch(program switch) for selection of DG set supply (DG1 & DG2) and wiring of change over switch (program switch) for selection of mains or DG supply. This item also includes supply & fixing of ladder along the wall for carrying power supply wires/cables from IPS room to Relay room/power room etc. Any masonry work required will be carried out by contactors own material.
Numbers Total 35449186.99 Item- 3 A 2 Telecom Supply Items S No. Item No Description of Item Unit Qty Rate Amount
100.00 HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti- rodent & anti-oxidant and non- flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. . One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End- cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color -Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer.
50.00 (Pt.)-2004 or latest; 100mm dia. (int. Dia) 3.65 mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes.
1.00 Aluminum with 05 digit counter, foldable with the bag. Total 254249.84 Item- 4 B 2 Telecom Execution Items. S No. Item No Description of Item Unit Qty Rate Amount RATLAM DIVISION-S AND T/WESTERN RLY
concrete miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).
75.00 Engineer in charge arranging /providing of labors for various safety related works such as protection of track etc. with contractor's T&P, equipment, hand signal flags, spanners, hammers, etc. as per specification special conditions and detailed scope of work as furnished in the tender and directed by the engineer incharge.
400.00 cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.
30.00 /Preparation of cable way/Chase 150mm wide at the bottom and 300 mm deep in hard rock (Drg prepared by contactor & approved by Engineer In charge) for laying of S&T cables where minimum required depth not possible & which is verified and agreed by Engineer In charge of the work or his representative shall be made as per Drg. No RE/S&T/ALD/SK/301/85. Refilling of the same with concrete mixture of 1:3:6 from top of the cable way/ chase. Payment of concrete will be made separately through a separate item in the schedule of work. RATLAM DIVISION-S AND T/WESTERN RLY
100.00 without damage of surface road using Auger Machine. The bore shall be 150 mm Dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtr long. The HDD with or without HDPE pipe as per direction of Engineer In charge. Note: HDPE pipe supply is taken as separate item. This item also includes cable laying (HDD boring).
100.00 with collars in trenches at places of track and road crossings, platform cuttings etc. also for straight cable laying. (Cable laying is covered separately.)
50.00 GI pipes 100 mm Dia (4.5 mm thickness) as per IS 1239 ( Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm Dia hole, or at any other locations as decided by Site Engineer. The GI pipe is to be filled with chattered compound. It includes supply of all material required for fi Xing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The e laying and fi Xing to be done as per RDSO drawings No. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest.
1000.00 cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trucking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of colored plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be daggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Total 643755.65
Item Breakup - XS1-NS Schedule
PVC insulated Railway Signaling Kilometre Indoor Single corewire conforming to IRS 76/89 (Amd3) or latest. Note:- Wire Colours shall be decided by engineer - in -Charge." (i)1 x 0.6 mm
PVC insulated Railway Signaling Kilometre Indoor Single corewire conforming to IRS 76/89 (Amd3) or latest. Note:- Wire Colours shall be decided by engineer - in -Charge (ii)1 x 1 mm
Provision of Printed PVC Vinyl Numbers Ferrule (up to 5mmDia) / custom label size of 50MM with thermal printfor CTR / Location Box and Junction Box (Color codingand With at least 300dpi print resolution, Ferrulecounting as approved & details provided by Railway)Colour of Ferrule: WHITE, BLACK, RED, LEMONYELLOW, GREEN, SKY BLUE, NEVY BLUE, ORANGE.FONT Colour: WHITE, BLACK, RED.
Supply of lead free Solder wire of Kg 20 SWG size96.5/3.5/0.5 (TIN/SILVER/COPPER) FLUX CORE/SOLID SOLDER WIRE. (Melting Point:- 217degreeCelsius to 218 degree Celsius).KHOSALA orCOOKSON or BT make of appropriate grade.
Supply of A -sign / AG - Sign/calling Numbers o n with LED Unit with Brackets &Fixing accessories complete.
Supply of Screw less typeFuse,2- Numbers wire front entry (one in-put & one out-put) The colourwill be decided by Engineer -in -Charge.(Preferably In Blue,Red& Grey Colors in the ratio of1:2:3)
Supply of Glass type cartidge fuse Numbers size 5x20 mm suitable for screwless terminal block 1 ampto 6 amp.
Supply of 16 Channel NVR as per Numbers technical specification 2.18
Supply of HDMI 10 meter long Numbers cable.
Supply of UTP reputed make.
Supply of 19" 9U Rack as per Numbers technical specification 1.48
Supply of offline UPS 1 KVA for Numbers single phase AC160V to 280V input with inbuilt batteries with 1 hour backup.
Supply strengthened outdoorunarmoured Optical fiber Cable ITU-T G652-D
Supply of 6 Fiber FDMS Box as Numbers technicalspecification and instruction of engineering incharge. RATLAM DIVISION-S AND T/WESTERN RLY
Supply of OFC patch cord having Numbers SC/LCA P Cconnector at one end SC/LC APCconnector atanother end as per siterequirement(suitable formediaconverter/SFP supplied)and lengthof patch cords 10 meters asper RDSO/SPN/TC/69/2007 rev. 1.0 orlatest asper instruction of engineering incharge.
Supply of Masonry RCC enclosure Numbers or box or Earth Chambers (6 sq mm Steel rein forced) for earth pits of Size 400mm Length(out side), 400mm Width (out side), 400mm Height and wall thickness of 40mm.
Supply Transformers per RDSOSpecification IRS/TC/76/2000 with latest Amendments suitable for underground quad cable. Total 955515.30 Item- 2 B3-Signalling Execution items for replacement of existing PI with new EI at 9 stations. S No. Item No Description of Item Unit Qty Rate Amount RATLAM DIVISION-S AND T/WESTERN RLY
Supply, Installation, Testing & Set Commissioning of Networkable Single loop addressable Fire alarm Control panel expandable upto 2 loops & interface with GSM/LTE module working as per RDSO/SPN/217/2025 ver-3.1 or latest. The control panel shall be networkable to Zonal /Divisional Headquarters preferably over TCP/lP and shall have clock synchronization facility. This schedule includes supply of TCP/IP converter/ Networking card. The control panel shall have provision of Graphical software to enable remote monitoring of entire fire detection and alarm system of a station from Head Quarters. The control panel shall be designed to work on power supply of 110V/230V AC as well as on DC battery backup of adequate capacity to work upto 24 hrs. Backup. The Power supplies like batteries and chargers shall be supplied by the contractor. The Control Panel shall have means for the user to visualize and interact with the complete Automatic Fire Detection and Alarm System layout through a user-friendly software executable on a standard Windows based Personal Computer. It shall be possible to download data and extend alarms from Control Panel through suitable ports like RS485/RS232/USB/TCP/IP into a PC/Laptop available with SSE at the installation and remote location (Divisional Control room) operating on Windows platform. The software for downloading and analysing fault data shall be provided & shall be compatible with the latest windows operating system. Detection, actuation, and control system shall have provision for automatic as well as manual operation. The GSM/LTE module for interfacing with Control panel duly providing compatible SIM with SMS facility on minimum of 5 numbers (users) and all other accessories. Spares cost are also included & to be supplied as per RDSO para no. 4.15. RATLAM DIVISION-S AND T/WESTERN RLY
Supply, Installation ,testing and Set commissioning of single channel laser or High power LED based Aspiration detection unit ( for AC room) with area covering 5000 sq. ft. with programmable 4 stage alarm generation and with 4 addressable modules. It should have auto cleaning facility in optical chamber, electronic discrimination of particle size, ultrasonic air flow sensing auto learn feature with TCP/IP network capability, the aspiration system shall also include external power supply unit with battery backup. Approval-UL/LPCB/VDS listed and shall comply to specification No. RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15
Supply, commissioning of Heat and smoke multi sensor with back box with integral short circuit isolator as per specification No. RDSO/SPN/217/2025 ver-3.1 or latest and required to be provided at suitable locations inside the diesel generator room, battery room, ASM room, and other S&T service rooms as directed by the Railway site Engineer. The location of fixing is to be meticulously decided so that full advantage of the system is achieved. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation and Testing, Numbers commissioning of Audio Visual alarm (Hooter and strobe) with back box controlled through addressable control model. Visual Alarms (Strobe): It shall be preferably flashing type RED/WHITE Color. Audio Alarms (Hooter): It shall be preferably with Piezoelectric type sounder. The sound level shall be preferably adjustable type up to 90dB at a distance of 1m as per specification No. RDSO/SPN/217/2025 Ver - 3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15. RATLAM DIVISION-S AND T/WESTERN RLY
Supply, Installation and Testing, Numbers commissioning of Analogue Addressable and resettable Manual call point with back box with integral short circuit isolator, Analogue addressable protocol having status LED for alarming & standby mode, Binary coded dip switch addressing. It shall have inbuilt fault isolator or alternate arrangement which shall isolate the Manual Call Point in case of open/short circuit fault within it as per specification No. RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, installation, Testing and Numbers Commissioning of Analogue Addressable type Isolator modules device for isolating in case of any fault, complying to the RDSO/SPN/217/2025 ver-3.1 or latest. Inspection by Rep. of Railway Engineer. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation, Testing and Numbers Commissioning of Relay module with back box and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation, testing and Numbers commissioning of Monitor module with back box and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, installation, testing & Numbers communication of Linear Heat Sensing (LHS) Interface module with all accessories for integration with main line fire alarm control panel as per RDSO specification No. RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation Testing and Metre commissioning of Analogue type Linear Heat Sensing cable with required module to be integrated on main Fire Alarm Panel as per specification No. RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply of Power supply System 24 Set V/2 Amp with built in Charger with battery backup as per specification No. RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15. RATLAM DIVISION-S AND T/WESTERN RLY
Supply, Installation Testing and Metre commissioning of FRLS/Fire Survival Circuit Integrity Cables and power cable with all accessories for connection of Fire Alarm devices specification No. RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation, Testing & Metre Commissioning of UL/LPCB/VDS listed CPVC Pipe with suitable diameter as per requirements & pipe accessories for the Aspiration detection shall comply to RDSO/SPN/217/2025 ver-3.1 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, installation, configuring, Numbers testing and commissioning of remote monitoring system along with software (GUI) along with license for Min. 20 addressing control panels with license as per RDSO/SPN/217/2025 Ver- 3.1 or latest. This includes necessary gateway card and network interface card for the system fully functional as desired by railways. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply and installation of remote Numbers sensing unit for fuse audio alarm & acknowledgement system.
Supply, installation, testing & Numbers commissioning of LED based point reversal indication & announcement system.
Installation ferules/cable stickers as per instruction of Engineer in charge. This includes supply of cable tie( if required) and shorting of ferules as per CTR and Location details. RATLAM DIVISION-S AND T/WESTERN RLY
Supply, Fabrication & fixing of Sqm hylam sheet of size12 mm thick (other dimension i.e. length andbreadthwill bedecided by Engg- in-charge) forA/case NE typebyproviding all fixtures includingfixing of PVCcoatedString Rods at the back side forcable supportwithcontractor own materials. Theitem includes fixingof M6terminals or screw less/fuse blocks /HRC fusesND typeon each strip. Twoextra holes on both sidesof M6terminals or screwless/ fuse blocks /HRC fuseand twoextra holes forfixing the sheet. Note: (i) Thecompletehylam sheetto be covered with either M6terminals orscrew less/fuse blocks /ND type HRCfuses as perinstructionsof engineer at site. (ii) Hylamsheet to be ofgradeP2. (iii) M6 terminals or screwless, HRC fuses willbesupplied by Railway. Theabove item alsoincludesfixing of Q series (GPR) relays.
Suppy and installation of ELD for Set quad cable conductors, earth resistance sensing unit for 24 nos of conductors with metering facility for one conductorat a time as per instructions of engineering in- charge.
Earthing & soldering of cable Numbers armour inside appratus case and other locations.
Provision of Earth connection RMT toLoaction Boxes and signals withMS Flat. A)Supply of MS flat ofsize 40X6mm at site which includes loading,unloading,transportation and fixing.
Supply of GI bolt of size M12 Set x25mm with two plan washers.
Drilling of holes in MS flat of Numbers defferent size at site.
Cutting bending, twisting of MSflat Per Weld duly heating at site.
painting of MS flat with onecoating RMT Red oxide and two coatsof Black paint .
Drilling of Holes in Location Boxes. Numbers
Termination of cable cores on ARA Numbers terminal/fuseblocks,8 way terminals block/ Screw-less connectorsin theapparatus cases/ cable termination rack at bothends.Both ends of a cable core terminated shall becountedas one terminal. This includes all associatedworks ofpulling out the cable from underground. Theitemincludes dressing of cables, making wiring treeetc. Thework shall be done as per Location/Cableterminationplans and as per the instruction ofEngineer-in-charge. RATLAM DIVISION-S AND T/WESTERN RLY
Complete painting varnishing work Station/IBH/Gate at station.This Includes painting of signal posts and fittings,apparatus cases, point machine, junctionboxes,signal machine, rail post etc. complete. This also includes Varnishing, Letter writing, on terminal Nos.and other details as per S.E.M part II annexure VI and instructions of Engineer at site. Item includes painting of distance of main cable run fromG.P oneach G.P. nearest to cable run and painting of distance of signal base from nearest line onthesignal base. At least two coats of paint is be applied besides primary coating of red oxide. This includes supply of paints varnishes and all material required for complete painting work at a station This includes painting on existing functional units also as per instruction of engineer- in-charge.
Laying of polylefin cable duct /RCC Numbers duct half round after laying of cable in the trenches before backfilling of soil as per the instrcutions of engineering in-charge.
Shifting of existing cables from old Numbers location boxes / relay room to new location boxes / new cable termination racks, terminating the conductors in serial order, bunching neatly for matching the circuits with new cables as per cable plan.
Supply, Installation, Testing and Numbers Commissioning of Full HD Fixed Bullet type IP Colour Camera along with 128 GB or Higher SD Card, housing and mount and all accessories required for installation purposes per RDSO Spec No RDSO/SPN/TC/65/2021, Rev 6.0 or latest.
Supply, Installation, Testing and Numbers Commissioning of Full HD PTZ type IP Colour Camera along with 128 GB or Higher SD Card, housing and mount and all accessories required for installation purposes as per RDSO Spec No RDSO/SPN/TC/65/2021, Rev 6.0 or latest.
Supply, Installation, Testing and Numbers Commissioning of Full HD Fixed Dome type IP Colour Camera along with 128 GB or Higher SD Card, Housing & Mount and all accessories required for installation purposes as per RDSO Spec No RDSO/SPN/TC/65/2021, Rev 6.0 or latest.
Supply and installation of 4 TB hard Numbers disk reputed make.
Installation, commissioning of NVR.
Supply &commissioning of 42" LEDdisplay of confirming as pertechnical specification 2.17. With HDMI port. RATLAM DIVISION-S AND T/WESTERN RLY
Supply and installation of 8 port Numbers POE manageable switch.
Installation of 19'' 9 U wall Numbers mounting rack supplied under Schedule.
Laying of OFC/Power cable/CAT-6 Metre cable/PA cable/Data cable and all the other types of telecom cable through HDPE pipe/casingcapping/fall ceiling with laying/fixing of HDPEpipe/casing capping/ PVC pipe for connecting/interfacing various components and system integration.
Splicing of fibers OFC Cable and Numbers making splice joint with contractor's own splicing machine and tools and consumables.
Supply and fixing of Variousgood Square Foot quality HD SignageTemplates with Caution slogansand other matter for display inRelay room, Duty Rooms, andother S&T Rooms. The abovematters should be printed on Forex, Vinyl foam sheet of atleast 5mm thickness withproper holes for fixing as perthe requirements of site and asinstructed by engineer in-charge, Size and quantity ofeach sheet will be decided by the engineer in-charge. The entire text matter, Font style and slogans will be decided by the Railway.
Fabrication, supply & provisionof Square Foot SWR Diagram Board onsuitable acrylic FRP sheet duly framed in Teak wood/ noncorasive Metalic Frame, as perthe supplied approved SWR diagram coloured.Size will bedecided by the engineer in-charge. RATLAM DIVISION-S AND T/WESTERN RLY
Maintenence of Track Mounted Numbers Equipments like S&T fittingon turnouts including different activities duringBCM/TTM/UNIMATE machine works as well as otherongoing engineering work and S&T maintenance work asfollows: Specially opening and refixing of DCTrack circuitjumpers/ Axle Counter transducers during differentEngineering Works. Opening of DCTrack circuit / AxleCounter transducers digging work from rail to TLJB / TMU/Location is required to be done as per site requirement alsoafter refixing of DCTrack circuit / Axle Counter transducersneeds to be buried in proper depth. It includes drilling hole inrail as per site requirement. The team to be provided for thiswork should comprise of: Fitter - 1 Nos., Blacksmith - 1 Nos.,Mason / Carpenter - 1 Nos. and Helpers - 5 Nos. also itincludes any work of Electrical operated lifting barriers(EOLB) or sliding boom and earthing arrangement ofSignalling gears. Any other work as per instruction ofRailway Engineer. All T&P & jigs required to execute thework will be supplied by the contractor. (NOTE: THE UNITFOR THIS ITEM SHALL BE READ AS "PER DAY PER TEAM")
Arranging/providing of labours for Man-Days various safety related works such as protection of track etc. with contractors T&P, equipment etc. as and when required by the Engineer in charge. Scope of work as furnished in the tender technical specification 3.1 and directed by the Engineer in charge.
Excavation foundation for Shunt Signal as per Drg. No. CSTE/6090 with Contractor's own materials including Cement and Anchor Bolts of Standard Size. The required scaffolding, Ferma etc. for Casting of foundation will have to be brought by the Contractor at his own cost and Erection and installation of Position Light Shunt signal with Base, Post, and Signal unit. Wiring & Fixing of Number Plate .The work shall be done as per instructions of Rly engineer at site.
Supply, Installation, testing & Numbers commissioning of New modular U Shape VDU Table for provision of 02 nos. VDU as per Detailed specifications and drawing intechnical specification 1.50 (attached with tender document). RATLAM DIVISION-S AND T/WESTERN RLY
Supply of documents and manuals Set for Installation,Testing, commissioning and maintenance of the (Oneset consist of 6 set of following drawings per Station).(i) Manual for installation, Testing, Commissioningand maintenance of the system for Technicians / Jr.Engineers. (Installation& Maintenance level) (ii)Functioning and system overview (Highermanagement level). (iii)Completion documents as perspecial conditions of contract. (iv) Design & Supply ofcircuits and plans to suit layout given in the signalingplan for Hot Standby Architecture ElectronicInterlocking (EI)system. All plans and wiring diagramshall be prepared on Auto cad Drawing and suppliedwith CD. This will include supply of Control cumIndication panel / VDU diagram, Square Sheet,Wiring Diagrams (Application Logic and InterfaceCircuit), Fuse Analysis, Contact Analysis, Tag BlockAnalysis, Power Supply Distribution / Powerequipment arrangement (with programswitch)Diagram, Auto Change over diagram (ifsupplied by the contractor), and all other relevantdrawings. NOTE: The contactor shall initially supply 1set of documents (Paper Prints) for approval ofRailways. He shall ensure the each sheet has a blockfor signature of Railway official as well as a block forsignature of firm, duly signed by the authoriesedsignatory of the firm. The name of the work as givenby Railways shall be written on every sheet under thework column. All the drawing shall be supplied inagood quality folder for each station. After approval of documents by Railways, the contractor will make copies of the approved documents and return the approved document to Railways. The contractor willthen make necessary correction to Application Logic software duly incorporating Railways' alterations/corrections/ comments, if any. After Complete Testing / Commissioning of the station,tracing of completion document as mentioned above will be submitted to Railways for approval. Along with the Completion application logic, difference report(showing addition & deletion in different colours) as compared to earlier approved application logic should also be submitted. After approval of completion application logic by Railways, 5 sets of copies of completion tracings will be submitted to Railways. RATLAM DIVISION-S AND T/WESTERN RLY
Supply Commissioning for Fibre Reinforced Calcium Sulphate Core Raised Access Flooring System as per technical specification 1.81.
Excavation foundation for main signal post as per CSTE/6294 (WR) with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost.
Fixing Sign/AG-Sign unit onsignal post.Item includes supply of bracket & fixing materials etc.. Total 32356112.30 Item- 3 A4 Telecom Supply Items . S No. Item No Description of Item Unit Qty Rate Amount
Supply of Permanently Lubricated Metre (PLB) High density polyethylene(HDPE) Telecom duct foruse as underground cable conduits -40/33 mm as per RDSO specification No.RDSO/SPN/TC/45/2013 Rev.2.0 amnd 1 & 2 or latest
Supply of Thermo shrink Universal Numbers Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC-77/2012 revision 3 Withlatest Amd
Supply of Half Round RCC pipes of Numbers 150mm inner dia (1 meter long) along with collars with material strength as per IS No. 458/2003 of NP type. Tenderer shall submit inspection/test report before supply for prior approval by Engineering incharge.
Supply of Thermo shrink Universal Numbers Jointing kit (TSF-1) for PIJF Cable (For 10/20 pair) as per RDSO Spec No RDSO/SPN/TC/57/2015, Rev.1, Amd.1
Supply of Straight Joint Enclosures Numbers (SJC)complete with all accessories as per GR/ OJC /02/02 Sept 2003for 48 fiber
Supply & installation of 8 port Numbers Manageable POE switch with 2 SFPs and its standard installation as per specification
Supply of RJ 45 Connector DAX, D- Numbers link, Digisol, AE, Molex,Amphenol make as approved by Engineer in charge
Supply of 6 core armoured Mono Metre mode OFC cable as per specification
Supply of CAT-6 cable of Dlink, Metre Digisol, Securenet,paramount,polycab make (with identificationmark/ferrules etc.) RATLAM DIVISION-S AND T/WESTERN RLY
Supply of SWITCH BOARD CABLE Metre (10 PAIR) CONFIRMING TO TEC SPECIFICATION G/WIR- 06/03 MAR 02 OR LATEST MAKE:- NETWORK CABLE OR SIMILAR
Supply of Two transformer type Numbers (2T) VF transformer derivation and termination of underground cable circuit Impedance ratio is 470:1120 as per RDSO specification no. IRS:TC- 76/2021 or latest (Cylindrical type).
Supply of OFC patch cord having Numbers SC/LC -ACP Cconnector at one end SC/LC- APCconnector atanother end as per siterequirement(suitable formediaconverter/SFP supplied) and length of patch cords 10 meters as per RDSO/SPN/TC/69/2007 rev. 1.0 or latest as per instruction of engineering incharge.
Supply of 9-U Dust proof Cabinet Numbers with cooling arrangement as per Technical specification 1.48.
Supply of PVC casing capping size Metre 32mm x12mm, conforming to IS 14927 Part-2 2001 or latest
Supply of White PVC Pipe of dia 1 Metre Inch of as per Standard IS:9537 (Part 3) with Pipe length of 3 mtrs each (Bend and Eblow as per site requirement will be supplied along with pipe)
Supply of Push Button Caller ID Numbers single line Auto Telephone with Line cord RJ-11 of Beetel, LG, Sony or Siemens make
Supply of wireless router/ access Numbers point for WI-FI connectivity as per technical specification
Supply of ONT with Dual- band Numbers wireless AC/N GGPON HGU with 4- port GbE LAN and RF Overlay as per technical specification
Supply of Tool Kit consisting of Numbers Optical power meter(Fibershot9990V or similar),Multimeter(Fluke 101 or similar),Ethernet Crimping Tool(Standard Make)Console cable(Cisco=RJ45- DB9),Wrist ripper(Standard Make),Universal Spanner Set (Taparia), Screw Driver Set (Taparia-7Pieces set), Cutting plier(Taparia), Wire Stripper, Industrial grade USB to Serial cable with all accessories or Similar.
Supply of Media Converter [OFC to Pair Ethernet] of make D-Link or MROTEK or DAX or similar as per RDSO SpecNo.RDSO/SPN/TC/103/2013Rev 2.0 or latest.
Supply of twin core shielded Metre microphone & speaker cable (Red &Black) each core shall be of 23/36 SWG PVC Insulated copper conductor in over all PVC Jacket of reputed make like Delton, Finolex,Asian or Superior. RATLAM DIVISION-S AND T/WESTERN RLY
Supply of 8 Port FXS Gateway (DC Numbers or AC based as per site requirement) including mounting kit and all other accessories. Its standard installation would be as per technical specifications.
Supply of Telescopic Ladder of Numbers Aluminum full of length 6.7 mtr when closed becomes 1.1mtr Long
Supply of VISUAL FAULT LOCATOR Numbers FOR OFC CABLES as per spcification
Supply of Metal OFC patch Cord Numbers Armoured , flexible, single mode, 9/125, duplex, SC-LC Connectors Optical fiber atch cords. Len th 20 mtrs. Make:lVEONET, D-LINK, ANDA only.
Supply of optical Patch cord cable Numbers (3 Meter long with connectors) as per RDSO specs no. RDSO /SPN/TC/69 /2007 or latest. Type of connector will be decide as per site requirement. Total 1841154.02 Item- 4 B 4 Telecom Execution Items . S No. Item No Description of Item Unit Qty Rate Amount
Blowing of OFC cable in already laid Metre PLB HDPE Duct, by using Blowing machine, providing the sufficient loops in loop/joint chambers and other associated works.
Laying of HDPE pipe as per Metre approved cable route plan in the excavated trench, taking due care while transporting and laying
Jointing /Signalingcable with Heat Shrinkable straight through Jointing Kit.
Laying of half round RCC pipe after Running Metre laying the cables in the trenches. (Cable laying is covered separately)
Supply and installation of RCC pre- Numbers fabricated OFC jointing Pits as per DRG. No- RDSO/TCDO/COP-21 (a)/latest
Supply, Installation, Testing, and Numbers commissioning of 24 port managed POE Layer 2 Access network switch as per RDSO SPECIFICATION- RDSO/SPN/TC/83/2020 Rev 2.0or latest.
Splicing of fibres OFC Cable and Numbers making Splice joint with contractor's own splicing machine
Installation of 9U complete accessories
Wiring, drawing, fixing, laying and Metre clipping of all telecom cable/PVC Power cable in PVC pipe/duct/Casing caping with complete fitting as per the instruction of site Engineer.
Supply and installation of CT box Numbers for 20 Pair for Termination of Telecom Cable as per technical specification RATLAM DIVISION-S AND T/WESTERN RLY
Supply, Installation, testing and Numbers commissioning of 48 Fiber (SC/APCSC/ APC) FDMS including splicing of OFC and termination of all fibres using pig tail cable of standard size ( All materials including pig tails (5 meter each) to be supplied by the contractor, this also includes arrangement & fixing of suitable metal box fixable in wall for spare OFC coil)
Supply, Installation, Testing & Numbers Commissioning of 19" 42U Rack with all accessories like Electrical fitting, Fan tray, STP Patch Panel, cable manager, spike buster for housing IP storage unit . All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost.
Supply GRP/FRPcable tray & required accessories asper specification Total 1740643.56
Item Breakup - XS2-NS Schedule
Design, manufacture and supply of Per Functional Hot Standby Architecture Electronic Vital Bit Interlocking (EI) system i.e. Centralized EI at Akodia station as per RDSO/SPN/192/2019 Ver.2.0 or latest and as per attached technical requirement & tentative approved Signalling Plans & Diagrams. This include Central Processing Equipment , Interface Equipment, All Interfacing Relays suitable for EI, In-built event Logger, interconnecting cables and Jumper wires, Required power supply converters for EI equipments, Housing for EI equipments & relay racks , fuses , screw less disconnecting type terminals, fixture mounting arrangements and other necessary accessories to make the EI system functional as per approved signalling plan. All items shall be supplied as per, per functional bit/station for functioning of EI. Negative variation in functional bit not permitted and for positive variation card wise/Modules etc. breakup should furnish by tenderer. Technical Requirement: 1. No of Bits Each station. 2. Architecture-Minimum 2 out of 2 Supply of 10% Essential spares of the EI equipments subject to minimum one of each type mainly consisting of processor, cards/ module, interface relay, DC DC Convertors, EI Relay Rack, OFC Connectors, etc. Item wise detailed break up with unit and quantity to be provided in separate annexure. (The quantity involves 10% spare). Note : Rate does not include cost of VDUs and Embedded PC . Dual operator Industrial Grade VDU panel and Embedded PC will be taken separately. Item wise detailed break up with unit and quantity to be provided in separately as per Annexure-1.1.9 of CA. (EI material to be supplied as per latest TAN and latest RDSO specification applicable before supply of the material) RATLAM DIVISION-S AND T/WESTERN RLY
Design, manufacture and supply of Per Functional Hot Standby Architecture Electronic Vital Bit Interlocking (EI) system i.e. Centralized EI at Shujalpur station as per RDSO/SPN/192/2019 Ver.2.0 or latest and as per attached technical requirement & tentative approved Signalling Plans & Diagrams. This include Central Processing Equipment , Interface Equipment, All Interfacing Relays suitable for EI, In-built event Logger, interconnecting cables and Jumper wires, Required power supply converters for EI equipments, Housing for EI equipments & relay racks , fuses , screw less disconnecting type terminals, fixture mounting arrangements and other necessary accessories to make the EI system functional as per approved signalling plan. All items shall be supplied as per, per functional bit/station for functioning of EI. Negative variation in functional bit not permitted and for positive variation card wise/Modules etc. breakup should furnish by tenderer. Technical Requirement: 1. No of Bits Each station. 2. Architecture-Minimum 2 out of 2 Supply of 10% Essential spares of the EI equipments subject to minimum one of each type mainly consisting of processor, cards/ module, interface relay, DC DC Convertors, EI Relay Rack, OFC Connectors, etc. Item wise detailed break up with unit and quantity to be provided in separate annexure. (The quantity involves 10% spare). Note : Rate does not include cost of VDUs and Embedded PC . Dual operator Industrial Grade VDU panel and Embedded PC will be taken separately. Item wise detailed break up with unit and quantity to be provided in separately as per Annexure-1.1.9 of CA. (EI material to be supplied as per latest TAN and latest RDSO specification applicable before supply of the material) RATLAM DIVISION-S AND T/WESTERN RLY
Design, manufacture and supply of Per Functional Hot Standby Architecture Electronic Vital Bit Interlocking (EI) system i.e. Centralized EI at Kalapipal station as per RDSO/SPN/192/2019 Ver.2.0 or latest and as per attached technical requirement & tentative approved Signalling Plans & Diagrams. This include Central Processing Equipment , Interface Equipment, All Interfacing Relays suitable for EI, In-built event Logger, interconnecting cables and Jumper wires, Required power supply converters for EI equipments, Housing for EI equipments & relay racks , fuses , screw less disconnecting type terminals, fixture mounting arrangements and other necessary accessories to make the EI system functional as per approved signalling plan. All items shall be supplied as per, per functional bit/station for functioning of EI. Negative variation in functional bit not permitted and for positive variation card wise/Modules etc. breakup should furnish by tenderer. Technical Requirement: 1. No of Bits Each station. 2. Architecture-Minimum 2 out of 2 Supply of 10% Essential spares of the EI equipments subject to minimum one of each type mainly consisting of processor, cards/ module, interface relay, DC DC Convertors, EI Relay Rack, OFC Connectors, etc. Item wise detailed break up with unit and quantity to be provided in separate annexure. (The quantity involves 10% spare). Note : Rate does not include cost of VDUs and Embedded PC . Dual operator Industrial Grade VDU panel and Embedded PC will be taken separately. Item wise detailed break up with unit and quantity to be provided in separately as per Annexure-1.1.9 of CA. (EI material to be supplied as per latest TAN and latest RDSO specification applicable before supply of the material) RATLAM DIVISION-S AND T/WESTERN RLY
Design, manufacture and supply of Per Functional Hot Standby Architecture Electronic Vital Bit Interlocking (EI) system i.e. Centralized EI at Jabri station as per RDSO/SPN/192/2019 Ver.2.0 or latest and as per attached technical requirement & tentative approved Signalling Plans & Diagrams. This include Central Processing Equipment , Interface Equipment, All Interfacing Relays suitable for EI, In-built event Logger, interconnecting cables and Jumper wires, Required power supply converters for EI equipments, Housing for EI equipments & relay racks , fuses , screw less disconnecting type terminals, fixture mounting arrangements and other necessary accessories to make the EI system functional as per approved signalling plan. All items shall be supplied as per, per functional bit/station for functioning of EI. Negative variation in functional bit not permitted and for positive variation card wise/Modules etc. breakup should furnish by tenderer. Technical Requirement: 1. No of Bits Each station. 2. Architecture-Minimum 2 out of 2 Supply of 10% Essential spares of the EI equipments subject to minimum one of each type mainly consisting of processor, cards/ module, interface relay, DC DC Convertors, EI Relay Rack, OFC Connectors, etc. Item wise detailed break up with unit and quantity to be provided in separate annexure. (The quantity involves 10% spare). Note : Rate does not include cost of VDUs and Embedded PC . Dual operator Industrial Grade VDU panel and Embedded PC will be taken separately. Item wise detailed break up with unit and quantity to be provided in separately as per Annexure-1.1.9 of CA. (EI material to be supplied as per latest TAN and latest RDSO specification applicable before supply of the material) RATLAM DIVISION-S AND T/WESTERN RLY
Design, manufacture and supply of Per Functional Hot Standby Architecture Electronic Vital Bit Interlocking (EI) system i.e. Centralized EI at Parvati station as per RDSO/SPN/192/2019 Ver.2.0 or latest and as per attached technical requirement & tentative approved Signalling Plans & Diagrams. This include Central Processing Equipment , Interface Equipment, All Interfacing Relays suitable for EI, In-built event Logger, interconnecting cables and Jumper wires, Required power supply converters for EI equipments, Housing for EI equipments & relay racks , fuses , screw less disconnecting type terminals, fixture mounting arrangements and other necessary accessories to make the EI system functional as per approved signalling plan. All items shall be supplied as per, per functional bit/station for functioning of EI. Negative variation in functional bit not permitted and for positive variation card wise/Modules etc. breakup should furnish by tenderer. Technical Requirement: 1. No of Bits Each station. 2. Architecture-Minimum 2 out of 2 Supply of 10% Essential spares of the EI equipments subject to minimum one of each type mainly consisting of processor, cards/ module, interface relay, DC DC Convertors, EI Relay Rack, OFC Connectors, etc. Item wise detailed break up with unit and quantity to be provided in separate annexure. (The quantity involves 10% spare). Note : Rate does not include cost of VDUs and Embedded PC . Dual operator Industrial Grade VDU panel and Embedded PC will be taken separately. Item wise detailed break up with unit and quantity to be provided in separately as per Annexure-1.1.9 of CA. (EI material to be supplied as per latest TAN and latest RDSO specification applicable before supply of the material) RATLAM DIVISION-S AND T/WESTERN RLY
Design, manufacture and supply of Per Functional Hot Standby Architecture Electronic Vital Bit Interlocking (EI) system i.e. Centralized EI at Baktal station as per RDSO/SPN/192/2019 Ver.2.0 or latest and as per attached technical requirement & tentative approved Signalling Plans & Diagrams. This include Central Processing Equipment , Interface Equipment, All Interfacing Relays suitable for EI, In-built event Logger, interconnecting cables and Jumper wires, Required power supply converters for EI equipments, Housing for EI equipments & relay racks , fuses , screw less disconnecting type terminals, fixture mounting arrangements and other necessary accessories to make the EI system functional as per approved signalling plan. All items shall be supplied as per, per functional bit/station for functioning of EI. Negative variation in functional bit not permitted and for positive variation card wise/Modules etc. breakup should furnish by tenderer. Technical Requirement: 1. No of Bits Each station. 2. Architecture-Minimum 2 out of 2 Supply of 10% Essential spares of the EI equipments subject to minimum one of each type mainly consisting of processor, cards/ module, interface relay, DC DC Convertors, EI Relay Rack, OFC Connectors, etc. Item wise detailed break up with unit and quantity to be provided in separate annexure. (The quantity involves 10% spare). Note : Rate does not include cost of VDUs and Embedded PC . Dual operator Industrial Grade VDU panel and Embedded PC will be taken separately. Item wise detailed break up with unit and quantity to be provided in separately as per Annexure-1.1.9 of CA. (EI material to be supplied as per latest TAN and latest RDSO specification applicable before supply of the material) RATLAM DIVISION-S AND T/WESTERN RLY
Design, manufacture and supply of Per Functional Hot Standby Architecture Electronic Vital Bit Interlocking (EI) system i.e. Distributed(Central+1 OC) EI at Sehore station as per RDSO/SPN/192/2019 Ver.2.0 or latest and as per attached technical requirement & tentative approved Signalling Plans & Diagrams. This include Central Processing Equipment , Interface Equipment, All Interfacing Relays suitable for EI, In-built event Logger, interconnecting cables and Jumper wires, Required power supply converters for EI equipments, Housing for EI equipments & relay racks , fuses , screw less disconnecting type terminals, fixture mounting arrangements and other necessary accessories to make the EI system functional as per approved signalling plan. All items shall be supplied as per, per functional bit/station for functioning of EI. Negative variation in functional bit not permitted and for positive variation card wise/Modules etc. breakup should furnish by tenderer. Technical Requirement: 1. No of Bits Each station. 2. Architecture-Minimum 2 out of 2 Supply of 10% Essential spares of the EI equipments subject to minimum one of each type mainly consisting of processor, cards/ module, interface relay, DC DC Convertors, EI Relay Rack, OFC Connectors, etc. Item wise detailed break up with unit and quantity to be provided in separate annexure. (The quantity involves 10% spare). Note : Rate does not include cost of VDUs and Embedded PC . Dual operator Industrial Grade VDU panel and Embedded PC will be taken separately. Item wise detailed break up with unit and quantity to be provided in separately as per Annexure-1.1.9 of CA. (EI material to be supplied as per latest TAN and latest RDSO specification applicable before supply of the material) RATLAM DIVISION-S AND T/WESTERN RLY
Design, manufacture and supply of Per Functional Hot Standby Architecture Electronic Vital Bit Interlocking (EI) system i.e. Centralized EI at Pachawan station as per RDSO/SPN/192/2019 Ver.2.0 or latest and as per attached technical requirement & tentative approved Signalling Plans & Diagrams. This include Central Processing Equipment , Interface Equipment, All Interfacing Relays suitable for EI, In-built event Logger, interconnecting cables and Jumper wires, Required power supply converters for EI equipments, Housing for EI equipments & relay racks , fuses , screw less disconnecting type terminals, fixture mounting arrangements and other necessary accessories to make the EI system functional as per approved signalling plan. All items shall be supplied as per, per functional bit/station for functioning of EI. Negative variation in functional bit not permitted and for positive variation card wise/Modules etc. breakup should furnish by tenderer. Technical Requirement: 1. No of Bits Each station. 2. Architecture-Minimum 2 out of 2 Supply of 10% Essential spares of the EI equipments subject to minimum one of each type mainly consisting of processor, cards/ module, interface relay, DC DC Convertors, EI Relay Rack, OFC Connectors, etc. Item wise detailed break up with unit and quantity to be provided in separate annexure. (The quantity involves 10% spare). Note : Rate does not include cost of VDUs and Embedded PC . Dual operator Industrial Grade VDU panel and Embedded PC will be taken separately. Item wise detailed break up with unit and quantity to be provided in separately as per Annexure-1.1.9 of CA. (EI material to be supplied as per latest TAN and latest RDSO specification applicable before supply of the material) RATLAM DIVISION-S AND T/WESTERN RLY
Design, manufacture and supply of Per Functional Hot Standby Architecture Electronic Vital Bit Interlocking (EI) system i.e. Centralized EI at Bakanian Bhaunri station as per RDSO/SPN/192/2019 Ver.2.0 or latest and as per attached technical requirement & tentative approved Signalling Plans & Diagrams. This include Central Processing Equipment , Interface Equipment, All Interfacing Relays suitable for EI, In-built event Logger, interconnecting cables and Jumper wires, Required power supply converters for EI equipments, Housing for EI equipments & relay racks , fuses , screw less disconnecting type terminals, fixture mounting arrangements and other necessary accessories to make the EI system functional as per approved signalling plan. All items shall be supplied as per, per functional bit/station for functioning of EI. Negative variation in functional bit not permitted and for positive variation card wise/Modules etc. breakup should furnish by tenderer. Technical Requirement: 1. No of Bits Each station. 2. Architecture-Minimum 2 out of 2 Supply of 10% Essential spares of the EI equipments subject to minimum one of each type mainly consisting of processor, cards/ module, interface relay, DC DC Convertors, EI Relay Rack, OFC Connectors, etc. Item wise detailed break up with unit and quantity to be provided in separate annexure. (The quantity involves 10% spare). Note : Rate does not include cost of VDUs and Embedded PC . Dual operator Industrial Grade VDU panel and Embedded PC will be taken separately. Item wise detailed break up with unit and quantity to be provided in separately as per Annexure-1.1.9 of CA. (EI material to be supplied as per latest TAN and latest RDSO specification applicable before supply of the material)
Installation, wiring, programming, Job testing and commissioning of EI equipment supplied as per supply item including transportation from Consignee's depot to site. The works and materials for installation, wiring, testing and commissioning, grouting, cutting of floors, walls, refilling of the same, re-plastering, required CC/ masonry works, fixing/ placing/ laying of insulated ladders/ casing-capping/ cable trays/ RCC/GI pipes / Cables, termination of cables with lugs/ connectors, painting, / lettering are to be provided/ done by the contractor for the equipments supplied vide supply Item of Schedule of this contract. This also covers the networking of built in EI Data RATLAM DIVISION-S AND T/WESTERN RLY loggers of all the stations to monitor the system to any other places where desired by Engineer- in-charge. Note: Installation shall be comply with RDSO Technical Advisory Note No STE/E/TAN/3012 ver 5.0 dtd 18.06.2026 or latest. Installation, wiring, programming, testing and commissioning of Operator VDU in Hot stand-by with Redundancy. Any Equipments/cards/Modules required for Hot stand-by with Redundancy shall be supplied & Installed by the Contractor. This also include supply of one no Godrej make operator chair model PCH7001 or better , one no. of composite computer & printer table (Godrej work station table or better) for keeping MT , one no Godrej make operator chair model PCH7001 or better. Termination of indoor/ PIJF cables in relay room on relays, tag blocks, CT racks as per approved wiring diagram including alterations/ modifications as required at site. Soldering to be done at all required termination. Dressing/ lacing of wiring shall be done neatly with help of dressing thread / plastic self-lock strip of suitable size. The tools/ equipments/ materials/ simulation boards required for testing shall be supplied / fabricated by contactor. This included replacement of modules/ cards/ LEDs/ equipments going defective during testing. Necessary power supply boards with required capacity plugs, sockets, surge & lightning protection boxes shall be supplied and installed by the contractor. 230V supply shall be arranged by Railways. In case supplies are required to be extended, from Power room / relay room then same shall be extended by the contractor with his own materials such as 1X16 sq. mm wires, cables, lugs, RCC/GI pipes, insulated ladders etc. After ST/LT testing, Factory Acceptance Tests (FAT) & Square Sheet testing system should be fault free while submitting to Railways, otherwise suitable necessary action can be taken by Engineer-in-charge Total 177770415.30
Item Breakup - XS3-Other items
Supply and commissioning of SMPS Set based Integrated Power Supply (IPS) System as per RDSO Spec. No. RDSO/SPN/165/2023 Ver. -4.0 Amendment 1.0 date effective 20.06.2024 with surge protection device, status monitoring panel, spares, tool kit, LMLA battery consisting of 55 plus 5 cells (cells as per RDSO spec. IRS: S-88/2004) along with battery stand.The configuration of IPS should be as per WR drawing 6295 (2 of 4 ).
Supply of Multi Section Digital Axle Per Detection Counter (MSDAC) for mentioned Point (DP) detection Point by the purchased & track Section as per SIP, complete with all accessories, cable required with each track device & card viz. Axle detectors, Track Side Electronics/DAC field units, Central Evaluator (Central Evaluator unit should be housed in a pre- fabricated rack to be supplied along with the system), reset unit, Relay unit, Event Logger & Diagnostic terminals, etc. Required for different Detection Points & Track Sections as per RDSO Specifications No. RDSO/SPN/176/2013, Ver.3 or latest and OEM/ manufacturer's specification and as per Annexures. (Quantity 01 No. = 01 DP) Inspection Authority: RDSO. Note:- As per WR's Policy No 03/2024 Para No. 3.4.2 .e .iv "VDU/Reset box can be used for resetting. At Stations having more than 10 Track sections, the Railway propose to use a separate VDU-based resetting system. Such a VDU- based system if using a PC, it must be industrial grade". For Shujalpur & Bakanian Bhaunri stations. Total 36912600.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril2022ACSNo_8.pdf
ATTACHMENT
GCCApril2022ACSNo_9.pdf
ATTACHMENT
GCCApril2022ACSNo_10.pdf
ATTACHMENT
I_CT_GCC-
ATTACHMENT
GCCApril2022ACSNo_1.pdf
ATTACHMENT
GCCApril2022ACSNo_2.pdf
ATTACHMENT
GCCApril2022ACSNo_3.pdf
ATTACHMENT
GCCApril2022ACSNo_4.pdf
ATTACHMENT
GCCApril2022ACSNo_5.pdf
ATTACHMENT
GCCApril2022ACSNo_6.pdf
ATTACHMENT
e-BGRBLetter.pdf
ATTACHMENT
GCCApril2022ACSNo11.pdf
ATTACHMENT
Appendix9EI010726.pdf
ATTACHMENT
AKDVERIFIEDSIP01.07.2026.pdf
ATTACHMENT
BKTLVERIFIEDSIP01.07.2026.pdf BKTL VERIFIED SIP
ATTACHMENT
BQEVERIFIEDSIP01.07.2026.pdf
ATTACHMENT
JBXVERIFIEDSIP01.07.2026.pdf
ATTACHMENT
KPPVERIFIEDSIP01.07.2026.pdf
ATTACHMENT
PNWNVERIFIEDSIP01.07.2026.pdf PNWN VERIFIED SIP
ATTACHMENT
PRBVERIFIEDSIP01.07.2026.pdf
ATTACHMENT
SEHVERIFIEDSIP01.07.2026.pdf
ATTACHMENT
SJPVERIFIEDSIP01.07.2026.pdf
ATTACHMENT
Tender_document_1.pdf
ATTACHMENT
Annexures.pdf
ATTACHMENT
GCCApril2022ACSNo_7.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
BKTLVERIFIEDSIP01.07.2026.pdf
ATTACHMENT
PNWNVERIFIEDSIP01.07.2026.pdf
ATTACHMENT
Download all tender documents and submit your bid