| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.0 LAccepted-AOC | ₹61.0 L Quoted ₹63.2 L | L1 | Accepted-AOC Negotiated the Lowest rate Quoted tenderer accepted |
| 2 | L2₹64.6 LRejected-AOC | ₹64.6 L | L2 | Rejected-AOC Rate quoted Higher than L1 Bidder |
| 3 | L3₹66.1 LRejected-AOC | ₹66.1 L | L3 | Rejected-AOC Rate quoted Higher than L1 Bidder |
| Sl No | Description | Qty | Unit | L RAMESH L3 | Ravi Electricals L1 | T PAULKANNU & CO L2 |
|---|---|---|---|---|---|---|
| 1.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End). | 113 | Pts. | 2,814 ₹3.2 L | 2,686 ₹3.0 L | 2,750 ₹3.1 L |
| 2.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plateand making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End. | 43 | Pts. | 2,279 ₹97,997 | 2,188 ₹94,084 | 2,233 ₹96,019 |
| 3.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End.(Street light point only) | 3 | Pts. | 3,081 ₹9,243 | 2,958 ₹8,874 | 3,020 ₹9,060 |
| 4.00 | Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. Higher end. | 84 | Nos. | 1,135 ₹95,340 | 1,090 ₹91,560 | 1,112 ₹93,408 |
| 5.00 | Supply and fixing of Philips make / eq) 9W LED bulb with battern holder for BH point. | 12 | Nos. | 335 ₹4,020 | 321 ₹3,852 | 328 ₹3,936 |
| 6.00 | Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb. | 19 | Nos. | 723 ₹13,737 | 695 ₹13,205 | 709 ₹13,471 |
| 7.00 | Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1no. 32mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting. | 3 | Nos. | 6,474 ₹19,422 | 6,216 ₹18,648 | 6,345 ₹19,035 |
| 8.00 | supply and fixing of 1200mm (48") sweep AC ceiling fan complete (Higher end) with 2 module 100W fan step regulator (Higher end) with 300mm down rod with fan clamp with side plates and cross arm of size 450mm (18"). | 30 | Nos. | 2,953 ₹88,590 | 2,835 ₹85,050 | 2,894 ₹86,820 |
| 9.00 | Supply and fixing of 400mm (16 inch) wall mount, Oscillating type fan with aerodynamically designedsemi transparent PP three blades for noise free operation with in built Speed regulator with necessary accessories with connections complete (Havells make Accelero HS/ Crompton High Flo Wave/ Usha Maxx Air/Eq.) | 1 | No. | 2,747 ₹2,747 | 2,638 ₹2,638 | 2,692 ₹2,692 |
| 10.00 | Supply and fixing of 300 mm (12") sweep (light duty) AC exhaust fan complete without provision of hole in the wall. | 15 | Nos. | 2,141 ₹32,115 | 2,055 ₹30,825 | 2,098 ₹31,470 |
Tender Value
₹61 L
EMD Value
₹40,500
Closing Date
18 Feb 2026, 3:00 pmClosed
Superintending Engineer
Office of Superintending Engineer PWD Buildings construction and maintenance circle Madurai
Provision for internal and external electrical arrangements including UPS Lift arrangements to the Construction of additional Building in Govt Hospital at Sholavandan in Madurai District
2026_PWD_652348_1
50SE/Bldgs C and M Circle Madurai 2025-26-2 dated 03.02.2026
Open Tender
Electrical Works
90 days
Sholavandhan, Madurai Dist
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹40,500
18 May 2026
10 Feb 2026
18 Feb 2026
10 Feb 2026
18 Feb 2026
10 Feb 2026
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End).
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plateand making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End.
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End.(Street light point only)
Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. Higher end.
Supply and fixing of Philips make / eq) 9W LED bulb with battern holder for BH point.
Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb.
Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1no. 32mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting.
supply and fixing of 1200mm (48") sweep AC ceiling fan complete (Higher end) with 2 module 100W fan step regulator (Higher end) with 300mm down rod with fan clamp with side plates and cross arm of size 450mm (18").
Supply and fixing of 400mm (16 inch) wall mount, Oscillating type fan with aerodynamically designedsemi transparent PP three blades for noise free operation with in built Speed regulator with necessary accessories with connections complete (Havells make Accelero HS/ Crompton High Flo Wave/ Usha Maxx Air/Eq.)
Supply and fixing of 300 mm (12") sweep (light duty) AC exhaust fan complete without provision of hole in the wall.
Supply and fixing of louvers shutters arrangements for 300 mm (12") sweep (light duty) AC exhaust fan.
Supply and fixing of 3nos.6A two module 3pin socket, 3nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End.
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End.
Supply and fixing of 20A Flush type Wall socket with 32A DP MCB in flush with wall with earth connection (For AC Plug).
Supply and fixing of 32A DP MCB in sheet enclosure inflush with wall and making good of the concealed portion with earth connection. [The MCB and metal enclosure should be of higher end]. UPS
Supply and fixing of 63A FP MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with earth connection. [The MCB and metal enclosure should be of higher end].
Supply and fixing of 8way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCB as incoming and 6nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End.(UPS out)
Supply and fixing of 4way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 100A 4P MCB switch as incoming and 4nos. 63A TP MCB as outgoing in flush with wall with earth connection only. Higher End.
Supply and fixing of 8 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board ( with MCCB incomer) with double door (metal door) with 1 No 160A 4P MCCB as incoming and 2Nos of 100ATP MCB, 4 Nos 63A 3P MCB, 6 Nos 6A to 32A SP MCB as outgoing with suitable cable end box in flush with wall with Earth connection only. Higher End.
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no.6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wireconnection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End.
Wiring with 2 x 1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with MS switch Box and 5A FT switch with painting of suitable colour continuous earth wire connection of 1.5 sq.mm copper wire for light point / fan point (for electronic regulator)
Wiring with 2 x 1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mm x 100mm x 75mm MS switch box for 5A 3 pin non interlocking flush type CS plug wfth painting of suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for open plug point.
Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable heavy gauge MS coundit pipe on wall and ceiling with continous earth wire connection of 4 sq.mm copper wire with painting of suitable colour.
Supply and fixing of 1.5 sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in existing concealed PVC pipe with necessary connection complete.
Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal door cover flush type fitted with busbars and neutral links with single phase MCB outgoings and seperate 4 way provision for accomodating one No 4 pole incoming MCB and another seperate 4 way provision for accomodating one No 4 pole RCD (totally 8 ways in one segment) (3x 4 ways in Each segment) and seperate provision for MCB ( totally 12 Nos) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with Earth connection only. i) 63A 4P MCB - 1 No ii) 63A 4P 30mA RCCB - 1 No, iii) 63A DP MCB Isolator -3 Nos, iv) 6A to 32A SP MCB - 12 Nos.
Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion.
Supply and run of 2 of 4sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4sq.mm copper wire and making good of the concealed portion with suitable colour.
Supply and run of 4 of 6sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6sq.mm copper wire and making good of the concealed portion with suitable colour.(7seg DB)
Supply and run of 2 of 6sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with contiinuous earth wire connection of 6sq.mm copper wire and making good of the concealed portion with suitable colour.UPS in
Supply and Run of 4 of 16 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 16 sq.mm copper wire and making good of the concealed portion.4W VTPN
Supply and clamping of 3-1/2 x 95 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps. (MCCB DB)
Supply and fixing of brass cable gland for 3-1/2 x 95 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3-1/2 x 95sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
Supply and clamping of 3-1/2 x 50 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps.(100A TPN switch)
Supply and fixing of brass cable gland for 3-1/2 x 50 sq.mm. aluminium PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3-1/2 x 50 sq.mm. aluminium PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
Supply and clamping of 3 1/2 x 240 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.
Supply and fixing of brass cable gland for 3 1/2 x 240 sqmm PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3 1/2 x 240 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.
Supply and fixing of 3 phase 315A aerial fuse unit for 3 Nos. 315A fuse units (500V) on suitable MS sheet covered with 6 mm thick hylem sheet on suitable angle iron work the tapping pole with necessary clamps.
Supply,erection,testing and commissioning of 2.0TR (6000K.cal/hr) ABS plastic split type inverter AC units Conforming to IS.1391(part-2) with AMT 1 to 2 fitted with inverter compressor operating on refrigerant (non-CFC) suitable for wall mounting) expect power consumpition norms suitable for operation on 230V.50Hz single phase AC supply with star rating of 5 as per BEE specification and capable of performing the functions of 1) Mounting / Fitting indoor and outdoor units at the respective locations. 2) Laying refrigerant pipeline of required length distance and connecting both units after drilling hole / holes in the wall, if required. Thickness of copper tubing shall not be less than 0.8mm.
3) Insulating the suction pipe with expanded polyethylene foam 8mm tubing. 4) Laying 25mm dia flexible PVC drain pipe to throw out the condensate water being formed within indoor unit. 5) Leakage testing the entire system. 6) Charging refrigerant gas in the unit. 7) Suitable electric wiring to be provided with 2.5sqmm PVC insulated copper wire between indoor and outdoor units upto 6 mtrs length and upto switch within 3 mtrs of location of indoor unit (Carrier/ Voltas/eq)
Supply,erection,testing and commissioning of 1.5TR (5000K.cal/hr) ABS plastic split type AC units Conforming to IS.1391(part-2) with AMT 1 to 2 fitted with Rotary compressor operating on refrigerant non-CFC suitable for wall mounting) expect power consumpition norms suitable for operation on 230V.50Hz single phase AC supply with star rating of 5 as per BEE specification and capable of performing the functions of 1) Cooling 2) Dehumidifying 3) Air circulating 4) Filtering The installation work for the above split type AC units inculds the following. 1.Mounting /fitting indoor and outdoor units at their respective locations.
2.Laying refrigerant pipe line of required length connection not exceeding 4meters distance and both units after drilling hole/holes in the wall if required.Thickness of the copper tubing shall not be less than 0.8mm. 3.Insulating the suction pipe with expanded polythylene foam 5mm tubing. 4. Laying 15mm dia flexible PVC drin pipe to throw out the consensate water being formed with in indoor unit. 5.Leakage testing the entire system gas in the unit. 6.Charging refrigerant gas in the unit. 7.Suitable electric wiring to be provided with 2.5sqmm PVC insulated copper wire between indoor units upto 6 mtrs length and up to switch with in 3meters of the location of indoor unit.(Carrier/Voltas/eq).
Supply and Installation of 5 KVA Electronic Automatic Voltage Stabilizer (V- GUARD make VND 500 Model / Eq) with Input Voltage range of 150Volt - 285Volt and Output Voltage range 200Volts to 230 Volts with High and Low Voltage cut off and 3minutes time delay relay with demonstration.
Supply and Installation of 4KVA Electronic Voltage stabilizer (V-guard make model VGS 500/Eq) with input voltage range 170-270V and output voltage range 200-240V with high and low voltage cut of 3min time delay relay with demonstration.
Supply and Laying of 5/8" and 3/8" copper pipe (Extra beyond 3 meters supplied with AC unit.
Supply and fixing of MS stand for fixing outdoor unit.
supply, commissioning, testing and handing over of 5KVA single phase input to single phase output micro processor controlled double conversion true on line UPS system with isolation transformer and suitable 12V, SMF batteries with suitable battery interlink cables for 1 Hour back up time and with suitable MS powder coated Rack for batteries complete with the following specifications
Configuration: True on line double conversion UPS system with pulse width modulation (PWM)Technology using IGBT inverter. RECTIFIER: Full wave (shall fully meet the specified input power requirements) INPUT : single phase 230V + 15% OUT PUT : 1% on battery mode FREQUENCY ; 47HZ - 53HZ SYSTEM DC VOLTAGE : 240V DC for 5KVA UPS INVERSION TECHNOLOGY : Micro processor controlled, pulse width modulation with instanataneous sine wave control using IGBT. INVERTER OUT PUT : ( Out put Galvanic Isolation through Double winding Isolation Transformer at Output of Inverter shall be part of UPS Design ) LOAD POWER FACTOR: 0.9 to unity REGULATION : for Balanced load ± 1% For 100% unbalanced load ± 2% FREQUENCY: 50Hz + 0.5%
WAVE FORM : Pure sine wave TOTAL HARMONIC DISTORTION : < 3% OVERLOAD CAPACITY: Inverse Time Characteristic 125% for 10 minutes 150% for 1 minutes EFFICIENCY : 1. Converter – 95% 2. Inverter - 95% 3. Overall >90% ( full load) Operating Temperature : 0 to 45 Degrees centigrade on full load CREAST FACTOR: 3 : 1 RELATIVE Humidity : : 95% at 35 Degree Centigrade non- Condensing CHARGER: Built in solid state automatic float- cum boost charger with constant current, constant voltage mode of charging along with current limiting features. Ripple in DC shall not exceed 2% when battery is disconnected.
PROTECTION( In built) i) Output under Voltage ii) Output over Voltage iii) Output over load iv) Output short circuit. v) HRC fuses /output/ battery vi) Battery low trip vii) Battery charges current limit. INDICATIONS: i. Mains ON ii. Inverter ON iii. UPS ON battery iv. Load On UPS v. Battery LOW
METERING: i. Output AC Voltage ii.Output DC Voltage / Load details and Frequency By Pass: Manual Centigrade non- Condensing CHARGER: Built in solid state automatic float- cum boost charger with constant current, constant, voltage mode of charging along with current limiting features. Ripple in DC shall not exceed 2% when battery is disconnected.
Supply and fabrication, erection 315A capacity dust vermin proof cubical EB LTCT metering panel board size of 4'x3'x1.5 made up of 16SWG sheet steel complete with hinged type locked key arrangement on support of 3'x2' TW plank with supporting of suitable angle iron work with 6mm thick hylem sheet with 1 1/4" x 1/4" with bus bar 3phase neutral to provide earth connection incoming fuse & meter champer, earth bus, 3Nos 315A 500V fuse unit with inter connection of 4x 19/16 copper wire fron EB meter to fuse unit CT coil 3Nos with earth connection complete. The panel board should be painted with High quality powder coated painted with super subcriptions.
Design, Engineering, supply, fabrication, erection, testing, commissioning and handing over of 1 No 20 persons capacity Bed cum passenger Gearless lift with machine room speed 1m/s with stainless steel panels, disable friendly,microprocessor based controller , VVRF drive, fire rated doors and ARD (KONE / OTIS /JHONSON) as per the following technical specifications with free Guarantee period of one year from the date of commissioning. Technical specifications: 1. Type of lift : passenger lift 2. Capacity of lift : 20 persons capacity passenger lift 3. Speed : 1.00 Meter/Sec 4. Type of Drive: specific variable voltage variable frequency V3F drive with enhanced ride comfort and leveling functions. 5. No. of floors: Ground + 1 floor 6. Leveling Accuracy: High level
7. Construction of Car: 18 SWG high quality stainless steel car, powder coated stretcher impact protection car size 2400 mm(D) x 1600 mm(W). 8. Position of machine: Directly above the lift well 9. No. of landing entrance: 2Nos 10. No. of car entrance: one in front only 11. Car entrance door: power operated. 12. Car entrance door: power operated center/side opening sliding 18 SWG stainless steel vandal proof door with provision for emergency key opening at all landings. 13. Lift well : existing (as per IS) 2335mm wide x 3000mm Deep
23.Minor builders work: included in the scope. 24.Scaffolding: Included in the scope 25.Sill angles and facia plates: included in the scope 26.Steel for lift machinery: Included in the scope 27.Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year. 28.Automatic Rescue device: To facilitate the landing of the lift to the nearest floor at the time of power failure. This shall consist of suitable type battery system with charger, invertor, under voltage protection system etc., complete with all accessories.
29.Provision of intercom with phone: To be provided by lift contractor with one handset in the lift car and another handset in the lift machine room with telecom exchange unite with one trunk and three extension linked proton 103 matrix telecom unit and required length of single twisted pair with thickness of 0.5 mm to 1mm connecting the handsets and telecom exchange unit. 30.Lift License: Preparation of Drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor. 31.Floor announciator with music. 32.Special features: a. Infra red door sensor with full height screen. b. Full width half height rear panel mirror. c. Tubular stainless steel hand rail in cars.
d. Voltage stabilizer for circuit control. e. Stainless. Steel signal fixtures. f. Vandal proof S.S. Button with S.S. cover g. SS door frames for landing doors. h. VF door operator. i. Call Register signal j. Stainless steel facia plate for car operating panel and landing fixtures. k. On – Off switch for fan and light l. Over load warning indicator with audio announcement 33. Other standard features: Over speed governor, phase failure and phase reversal relay, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, electro mechanical door locks emergency keyside supporting angles, motor over load protection devices final limit switch main suspension ropes counter weights lifting joist for mounting the machineries
34.Site testing in accordance with IS 14665 should be carried out at the time of handing over. 35.Supply of operation and maintenance manual with necessary tools for operation. 36.Guarantee: Free Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period of one year from the date of commissioning. (KONE / OTIS /JHONSON)
Supply and fixing of 63A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with earth connection only.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.
Supply and Run of 1 of No.8 SWG copper wire for earth connection.
Supply and run of 25mmx3mm tinned copper flat with necessary clamps /supports on wall /floor /ground for earth connection.
Supply, fabrication, erection and commissioning of 315A dust and vermin proof floor mounting cubical type panel board of size 7.5ft x 5ft x 1ft made up of 16 SWG CRCA sheet steel for outer body and stiffness and doors, switch supports respectively and supply and fixing of following interior mounting switches with centre bus bar chamber and vertical covers on both sides of the bus bar chamber at the extreme ends side and confirming to IS specification. All the main switches should be L&T / Siemens make only interconnection of switches with busbar chamber.
(2) 315 A TPN switch disconnector interior only with HRC fuses double break as outgoing - 1 No (L&T/Siemens) with interconnections of 1 1/4" x 1/4" tinned copper flat from bus bar chamber. (3) 200 A TPN switch disconnector interior only with HRC fuses double break as outgoing - 1 Nos (L&T/Siemens) with interconnections of 1" x 1/4" tinned copper flat from bus bar chamber. (4) 125 A TPN switch disconnector fuse interior only with HRC fuses double break as outgoing - 6 Nos (L&T/Siemens) with interconnections of 1" x 1/8" tinned copper flat from bus bar chamber. (5) 63 A TPN switch disconnector fuse interior only with HRC fuses double break as outgoing - 5 Nos (L&T/Siemens) with interconnections of 3/4" x 1/8" tinned copper flat from bus bar chamber.
A separate chamber on top of one side should be built with multi function digital volt meter, ammeter and frequency meter with one set of LED pilot lamp set with fuse base, top with 10A HRC link for 3 phase (Siemns) the bus will have 2 Nos 1 1/4" x 1/4" earth bus must be run all around the panel to provide double earth connection to the cubical switches cable glands, cable adopter box etc the bus should be mounted on synthetic moulded compound bus support at equal interval as per IS specifications. The switch should be separated from the bus by 6mm thick hylum sheet separators, and properly earthed by tinned solid copper flat as per CEIG sepecifications. The panel should be powder coated, the cable size, capacity of switch, location etc., should be marked with white paint and 2 Nos. metallic danger board affixed complete with mounting on base channel 3"x1½"x½" iron frame work support complete.
Supply and fixing of 100A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with Earth connection only. (X-ray block)
Supply and clamping of 3-1/2 x 25 sq.mm. aluminium PVC LTUG armoured cable on post or on wall with MS clamps. (Lift)
Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. aluminium PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3-1/2 x 25 sq.mm. aluminium PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
formghsholandhanelect.pdf
Tender Documents • 1.36 MB
BOQ_782212.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid