Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.7 LAccepted-AOC BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹64.1 L+₹7,970 (0.12%)Rejected-Finance | L2 | Rejected-Finance Being other than Lowest | |
| 3 | L3₹77.7 L+₹13.7 L (21.4%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance Being other than Lowest | |
| 4 | Rejected-Technical NOT AVAILABLE | - | Rejected-Technical firm not enlisted in b (ii) category |
Tender Value
₹87 L
EMD Value
₹1.6 L
Closing Date
24 Jun 2020, 6:00 pmClosed
CWE (NW) MUMBAI
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIRS REPLACEMENT OF STREET LIGHT FITTINGS HT LT ELECTRIC CABLES HT LT CAPACITOR BANK OVERHAULING OF HT VCB LT ACB AND PAINTING OF ELECTRIC MACHINES EQUIPMENTS AND ALLIED ELECTRIC WORK AND REPAIR MAINTENANCE OF ELECTRIC FANS EXHAUST FANS MCB DBS
2020_MES_347568_1
8060/CWE(NW)/MUMBAI
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE (I) ASVINI
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
AGE (I) ASVINI
₹1.6 L
Yes
21 Sept 2020
26 May 2020
26 Jun 2020
26 May 2020
24 Jun 2020
10 Jun 2020
26 May 2020 - 9 Jun 2020
Amount
Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors complete all as specified and directed
M & L in replacement of point wiring with two run of PVC insulated unsheathed single core multi stranded copper conductor 1.5 sqmm (Red and Block colour), 1100 volts grade cable, FRLS, passing through PVC casing caping 25/32mm including accessories and S&F PVC box or uni modular PVC box with silver line border for mounting modular or non modular fittings like switches, switch socket, fan regulator complete all as specified and directed including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) FRLS earth wire and connected to earth dolly for the following:- NOTE :- Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm.
One light/Exhaust/Ceiling fan point controlled by one switch.
One 3 pin switch socket combination 5 Amps on the same board with other switches.
One 3 pin switch socket combination 5 Amps, independent.
One bell point controlled by one push button
All as per item No 2.00 above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch.
S & F in replacement of ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm complete all as specified and directed
S & F in replacement of buzzer, ding dong, AC, 230V single pole complete all as specified and directed.
S & F in replacement of modular switch, 6Amp, 1 module, single pole one way complete all as specified and directed . Make: Pressfit/Anchor/Crabtree/Legrand.
S & F in replacement of modular bell switch, 6Amp, 1 module, single pole one way complete all as specified and directed . Make: Pressfit/Anchor/Crabtree/Legrand.
S & F in replacement of modular socket 6Amp, 2/3 pin, 2 module complete all as specified and directed. Make: Pressfit/Anchor/Crabtree/Legrand.
S & F in replacement of modular socket 6/16A, 6 pin, 2 module complete all as specified and directed. Make: Pressfit/Anchor/Crabtree/Legrand.
S & F in replacement of modular switch, 16Amp, 1 module, single pole one way complete all as specified and directed. Make: Pressfit/Anchor/Crabtree/Legrand.
S & F in replacement of modular stepped type fan regulator, 2 module, single pole one way complete all as specified and directed. Make: Pressfit/Anchor/Crabtree/Legrand.
S & F in replacement of lamp holder, SX- Metal ring Angle/Batten, PVC/Polycarbonate body with 7 W LED Lamp complete all as specified and directed
S & F in replacement of Flash angle lamp holder (2 Module), PVC/Polycarbonate body with suitable LED lamp 5 to 7Watts complete all as specified and directed.
S & F in replacement of MCB TPN DB 8 Way, (8+24) conforming to IP 43 - IK 09 with acrylic door with 100 Amp copper bus bar for each phase, complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces complete all as specified and directed. Make :Legrand cat part no: 507732/ Siemens/ L & T.
S & F in replacement of MCB SPN, 240 Volt, 32 Amp, 10 KA, Complete all as specified and as directed. Make : Legrand / Siemens/ L & T.
S & F in replacement of MCB, single pole, 240 Volt, upto 32 Amp, 10 KA complete all as specified and directed. Make : Legrand/ L &T / Siemens.
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F in replacement of uni modular PVC Gang box, screwless, with silver border of 12 module for mounting of modular switches and sockets including blank plate for blank module complete all as specified and directed. Make- Pressfit/Indoasian/Crabtree/Anchor.
All as per Item No- 17.00 above but of uni modular PVC Gang box, 8 module.
All as per Item No- 17.00 above but of uni modular PVC Gang box, 6 module.
All as per Item No- 17.00 above but of uni modular PVC Gang box, 4 module.
All as per Item No- 17.00 above but of uni modular PVC Gang box, 3 module.
All as per Item No- 17.00 above but of uni modular PVC Gang box, 2 module.
All as per Item No- 17.00 above but of uni modular PVC Gang box, 1 module.
Taking down unserviceable FTL and supply and fix in replacement of 1 x 10Watts, 2 feet, LED fitting and fixture Decorative ultra slim square profile with extruded polycorbonate, environmental friendly , energy efficient ready to use pack, prewired complete with two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose complete all as specified and directed. Make : Havells cat part no: 10W LED 6500K or equivalent Wipro/Philips.
Taking down unserviceable FTL and supply and fix in replacement of 1 x 20Watts, 4 feet, LED fitting and fixture Decorative ultra slim square profile with extruded polycorbonate, environmental friendly , energy efficient ready to use pack, prewired complete with two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose complete all as specified and directed. Make : Havells cat part no: 20W LED 6500K or equivalent Wipro/Philips.
Taking down U/S Recess mounting FTL and S & F in replacement of LED Recessed/Surface 1 x 1 Feet , 18 Watts, Polaris IV is a exquisitely designed luminaire which is bound to deliver extra ordinary lumens through its pure from nd glare-less light , complete all as specified and directed. Make: - Crompton cat part no. LCTLRN -18-CDL or Equivalent Phillips/Wipro.
S & F in replacement of PVC moulded terminal boxes of following sizes, ISI marked suitable to accommodate switches/ sockets/ regulator etc including fixing of old switches, sockets, fixtures retrived from old PVC box or new fittings and fixtures complete all as specified and directed. Make : Plastobox/National/Plaza/Presto Teak/Pressfit/ Presto plast of following size : -
100 mm x 100 mm x 50 mm
175 mm x 100 mm x 50 mm
200 mmx 150 mm x 50 mm
M&L for Earthing complete with galvanized iron earth plate electrode 600 x600x6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.6 meter below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts check nuts galvanized iron or steel all as shown in Electrical plate No. 3 of MES sch pt I testing on completion with & incl. 15 mm bore light grade GI protection pipe 7.5 mtr long for earth lead, PCC (1:3:6) pit with pre cast RCC (1:2:4) cover watering arrangement with funnel, wire mesh 20 mm bore light grade GI pipe, common salt & char coal fixing necessary excavation earth work complete all as specified and directed
Supply and laying in replacement of service wire 1100 volts grade heavy duty cable with XLPC insulated aluminium conductor served with an inner sheathing of XLPE tape armoured with tape and overall PVC sheathed 10 sq. mm two core nominal cross section in complete all as specified and directed. Make-polycab/Havells/KEI
S & F in replacement of MCB TPN DB 4 Way, (4+12) conforming to IP 43 - IK 09 with acrylic door with 100 Amp copper bus bar for each phase, complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces complete all as specified and directed. Make :Legrand cat part no: 507730/ Siemens/ L & T.
M&L in replacement of sub main wiring with two single core pvc insulated unsheathed FR copper conductor 1100 volt grade multistandard of size 4.0 sqmm and incl drawn through PVC casing capping 25x12mm/32x12mm including accesssories (ISI marks), one run of 2.5 sqmm copper wire for earth continuity wire and connected of common earth dolly complete all as specified and directed. Make: polycab/finolex/Havells/ Plaza/Press Fit. Note:- One run of PVC casing capping 25x12mm/32x12mm, two run of 4 sq mm copper conductor & one run of 2.5 sq mm copper conductor is measured as one unit.
M&L in replacement of sub main wiring with two single core pvc insulated unsheathed FR copper conductor 1100 volt grade multistandard of size 6 sqmm and incl drawn through PVC casing capping 25x12mm/32x12mm including accesssories (ISI marks), one run of 4.0 sqmm copper wire for earth continuity wire and connected of common earth dolly complete all as specified and directed. Make: polycab/finolex/Havells/ Plaza/Press Fit . Note:- One run of PVC casing capping 25x12mm/32x12mm, two run of 6 sq mm copper conductor & one run of 4 sq mm copper conductor is measured as one unit.
REPAIR/REPLACEMENT OF FANS:- M&L for painting all expose surface including blades of ceiling fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after scrabing cleaning all old paint etc including writing MES No and MES in black paint at site complete all as specified and directed
All as per Item No 27 above but exhaust fan of any size and Make.
All as per Item No 27 above but Pedestal/wall mounting/Air circulator fan fan of any size and Make
Taking down servicable/ unservicable ceiling fans for day to day maint from site and overhauling of ceiling fans any size and Make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, replacing the unserviceable spare parts complete with re-assembling and connecting copper conductor multi stranded 3 core wire of size 14/0.0076, and testing after re-fixing at site complete all as specified and directed Note:- (i) Rate of petty items like hanging clamp set, bottom & top canopy, split pin, bolt & nut, spindle, cover fix screw and blade fixing screw, down rod shall be included in the above quoted rate. (ii) The spare parts bush, ball bearing, condensor, fan blade set, bottom cover/top cover, stator, rotor shall be measured and paid separately under relevant item.
All as per Item No 28 above but exhaust fan of any size and Make.
All as per Item No 28 above but Pedestal/wall mounting/Air circulator fan of any size and Make.
Supply and fixing in replacement of bush suitable for Ceiling/Exhaust/Pedestal/wall mounting/Air circulator fan of any type & size complete all as specified and directed Make : NBC/SKF/Tata
Supply and fixing in replacement of ball bearing suitable for Ceiling/Exhaust/Pedestal/wall mounting/Air circulator fan of any type & size complete all as specified and directed Make : NBC/SKF/Tata
Supply and fixing in replacement bottom & top cover suitable for ceiling fan any make and any size complete all as specified and directed
Supply and fixing in replacement Ceiling fan blade any make and any size complete all as specified and directed
Supply and fixing in replacement ceiling fan stator assembly with super enamelled copper wire of same grade/size/gauge, no of turns as per existing any make and any size complete all as specified and directed
Supply and fixing in replacement ceiling fan rotor assembly any make and any size complete all as specified and directed
Supply and fixing in replacement of condensor 2.5 Mfd oil filled metalic body complete all as specified and directed. Make:Universal/EPCOS/USHA
All as per Item No 36 above but cap 3.15 Mfd. Make: Universal/EPCOS/USHA
All as per Item No 36 above but 4 Mfd Make: universal/EPCOS/USHA
Supply and fixing in replacement of twin core flexible wire size 23/.0076 complete all as specified and directed. Make - Finolex/Havells/Plaza
Supply and fixing in replacement Exhaust fan blade any make and any size complete all as specified and directed
M&L for Re-winding the damaged burnt winding by taking out from ceiling fan stator assembly of 1200 mm sweep, cleaning the slot and, rewinding with super enamelled copper wire of same grade/size/gauge, no of turns as per existing and duly heating & varnishing including greasing/oiling and commissioning/ testing complete all as specified and directed
All as per Item No- 41 above but for ceiling fan of 1400 mm sweep.
All as per Item No- 41 above but for exhaust fan of 230/300mm sweep.
All as per Item No- 41 above but for exhaust fan of 380/400/450 mm sweep.
All as per Item No-41 above but for pedestal/wall mounting/air circulator fan 300/400/450mm sweep
Supply and fixing replacement of Plastic Ventilation fan 200mm sweep (8") white ,Energy saving fans ,230V AC ,50 HZ complete all as specified and directed . Make-Havells/Usha/Orient.
Supply and fixing replacement of Heavy duty exhaust fans 300mm sweep (12"), Energy saving fans,1400 RPM, 230V AC ,50 HZ, complete all as specified and as directed. Make-Havells/Usha/Orient.
Supply and fixing in replacement of ceiling fans 1200mm sweep (48"), summer cool type, Energy saving fans ,230V AC ,50 HZ complete all as specified and directed. Make-Havells/Usha/Orient.
Taking down deteriorted louvers and supplying and fix new louvers fixed type any size made out of 1.6mm GI sheet with horizontal ventilation, machine pressed cutting for horizontal ventilation with flat iron base of complete all as specified and directed
Cutting hole in existing concrete or brick wall suitable for fixing 230/300/380/450mm sweep exhaust fan making good the hole including proper internal plaster work and surface finish in side and outside the hole as per site requirement complete all as specified and directed
REPAIR/REPLACEMENT OF GEYSERS:- M&L for painting all external surface on Geyser 25/50 ltr capacity complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after scrabing cleaning all old paint etc including writing MES No and MES in black paint at site complete all as specified and directed
S&F in replacement of heating element 1.5 KW of any type ( Trangular/Threaded/ Cup type) for geyser 25 ltr capacity complete all as specified and directed (work will be executed at site where geysers installed).Make-Bajaj/Ujala/pearl.
All as per Item No- 52 above but 2 KW for 50 ltr capacity geysers. Make-Bajaj/Ujala/pearl.
S&F in replacement of indicating lamp round/flat type as per existing suitable for 25/50 ltr capacity geysers complete all as specified and directed. Make Bajaj/Ujala/pearl.
S&F in repair fusible plug for any size of geyser complete all as specified and directed
S&F for replacement of unserviceable thermostate cut-out adjustable for 40-80*C ISI marked suitable for 25/50 ltr capacity geysers complete all as specified and directed Make-Bajaj/Ujala/pearl.
S&F in replacement of safety/pressure release/non return valve brass (ISI marked) best quality size 15mm suitable for 25/50 ltr capacity geysers complete all as specified and directed Make-Bajaj/Ujala/pearl.
Opening of geysers 25/50 ltr capacity for examining inner shell of copper and repairing the same by brazing at the point of leakage and testing complete on completion (Rate includes the rate of taking down and refixing the geyser after repair) complete all as specified and directed
S&F in replacement of flexible connection pipe heavy duty braided hose PVC Pipe 600mm Long,15mm Dia (suitable for Hot water) of superior quality as per existing pattern with brass union & washer fitted at both end suitable to 15mm GI pipe line complete all as specified and directed
S&F in replacement of Brass apparatus plate assembly for 25/50 ltr geysers complete all as specified and directed. Make-Bajaj/Ujala/pearl.
S&F in replacement of rubber ring gasket suitable for apparatus plate assembly 25/50 ltr geysers complete all as specified and directed. Make-Bajaj/Ujala/pearl.
S&F in replacement of flexible connection pipe heavy duty braided hose PVC Pipe 450mm Long,15mm Dia (suitable for Hot water) of superior quality as per existing pattern with brass union & washer fitted at both end suitable to 15mm GI pipe line complete all as specified and directed
S&F replacement of Hot Water Heater Storage type 25 Ltr, 230Volts, star rating with heating element 2KW with fixing wall through proper nut, bolt ,fastner with three core 2.5 sqmm wire proper connected to top plug complete all as specified and directed. Make:Bajaj/Havells/Recold.
S&F replacement of Galaxy 3 pin plug top with indicator 16Amp, complete all as specified and directed. Make: Press Fit/Havelles/Standard.
M&L replacement of socket outlet 2 in 1 , 5 Pin 5 & 15 Amps, 230 Volts, ACcomplete all as specified and directed. Make- Press Fit/Anchor/Havells.
M&L replacement of Switch piano flush type single pole, one way 15 Amps 230 Volts, AC, complete all as specified and directed. Make- Press Fit/Anchor/Havells.
M&L replacement of Switch socket combination 2 in 1 ,3 pin 5 &15 Amps, 230 Volts, AC, complete all as specified and directed. Make- Press Fit/Anchor/Havells.
S&F replacement of metalic AC plug top & Socket 20Amp, 3 pole complete all as specified and directed. Make: Press Fit/Havelles/Standard.
S&F MCCB 04 pole, 50 KA, 630 Amps, AC 415 Voltscomplete all as specified and directed Make:-HPL/Havells/L&T Lexic/Legrand/C&S Electric Ltd/ABB
S&F MCCB 04 pole, 50 KA, 400 Amps, AC 415 Volts ,complete all as specified and directed Make:-HPL/Havells/L&T Lexic/Legrand/C&S Electric Ltd/ABB
S&F MCCB 04 pole, 36 KA, 250 Amps, AC 415 Volts complete all as specified and directed Make:-HPL/Havells/L&T Lexic/Legrand/C&S Electric Ltd/ABB
S&F MCCB 04 pole, 36 KA, 200 Amps, AC 415 Volts complete all as specified and directed Make:-HPL/Havells/L&T Lexic/Legrand/C&S Electric Ltd/ABB
S&F MCCB 04 pole, 25 KA, 125 Amps, AC 415 Volts complete all as specified and directed. Make:-HPL/Havells /L&T Lexic/Legrand/C&S Electric Ltd/ABB
S&F MCCB 04 pole, 25 KA, 100 Amps, AC 415 Volts complete all as specified and directed. Make:-HPL/Havells /L&T Lexic/Legrand/C&S Electric Ltd/ABB
S&F MCCB 04 pole, 16 KA, 63 Amps, AC 415 Volts complete all as specified and direct. Make:-HPL/Havells/L&T Lexic/Legrand/C&S Electric Ltd/ABB
Taking down U/S Recess mounting FTL and S & F in replacement of LED Recessed/Surface 2 x 2 Feet , 36 Watts, Polaris III is a exquisitely designed luminaire which is bound to deliver extra ordinary lumens through its pure from nd glare-less light, complete all as specified and directed Make: - Crompton cat part no. LCTLRN-36-CDL or Equivalent Phillips/Wipro.
Taking down U/S Recess mounting FTL and S & F in replacement of SPAN is LED Recessed/Surface 1 x 4 Feet , 40Watts, Flat panel ceiling light with high performance, commercial grade solution suitable for hospitals and so much more, complete all as specified and directed. Make: - Crompton cat part no. LCTLRN-40-CDL(1X4) or Equivalent Phillips/Wipro.
Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350 MVA, 400/630/800/1200 Amps from location and repair /overhauling and carrying out with complete all as specified and directed (Note: spare parts will be measured & paid seperately.) (i) Inspecting / overhauling of manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly. (ii) Inspecting / overhauling of tripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system. (iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptors by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces. (iv) Assembling all items/components parts to the respective position & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete.
Material and labour for painting of HT VCB capacity 250/350MVA,11KV, 400/630/800/1200Amps, with one coat of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities for out side surface and in side surface of OCB complete all as specified and directed
Overhauling, calibration and secondary injection of over current earth fault relays/release on each multiple setting readjustment by artificial load complete all as specified including testing complete.
Dismantling, overhauling and testing Potential transformer capacity 11 KV / 110 volts, AC and replacement of worn out spares such as contacts, bushing, control wiring fibre plates, gaskets , transformer oil and applying multi grease to the mechenical parts & dry graphite conductive sealant to contacts etc & re-assembling the same and commissioning complete all as specified and directed. (Note : Spare parts and oil will be measured and paid seperately)
Testing of dielectric strength of transformer oil of indoor type transformer, 11KV/433 volt, filteration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electic strength to above 40 KV for 1 minute including new transformer oil for toping up & testing after filtration complete all as specified and directed. (Note: Transformer oil will be measured & paid seperately.)
Supply only transformer oil with 50KV di-electric strength for topping up and replacement of old/burnt transformer oil complete all as specified and directed Make: Power /Asian/Savita/Electric.
Supply and fixing in repair of breather with 500 Grams silica gel of indoor type transformer for 1600KVA, complete all as specified and directed
Material and labour for Spray Painting of Transformer 1600KVA ,11KV/440Volt capacity, indoor type with two coats of synthetic enamel paint over a coat of red oxide primer after cleaning, scraping, and filling of cavities complete all as specified and directed
Material and labour for disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer 1600KVA ,11KV/440Volt, top cover and dismantling of 4Nos LT bushing and 3Nos of HT bushing including necessary tools and plant for attending leakage problem with replacement of oil seal, all gaskets, thermometer(oil temperature gauge) and reassembling complete all as specified and directed. (Note : New Transformer oil and spare parts will be measured and paid separately excluding oil seal and thermometer i.e oil temperature gauge)
Material and labour in repair of burnt out studs and bushing with nuts of Transformer 1600KVA ,11KV/440Volt, any material by providing new copper alloy stud with nut,washers and bushing with oil seals on HT side complete all as specified and directed
Material and labour in repair for burnt out studs and bushing with nuts of Transformer 1600KVA ,11KV/440Volt, any material by providing new copper alloy stud with nut,washers and bushing with oil seals on LT side complete all as specified and directed
Supply and fix in repair of following spare parts suitable for Siemens/ABB/Schnieder make VCB, 11 KV , 630/800/ 1000/1200 Amps indoor type complete all as specified and directed
Opening / Closing Push Button Assembly
Motor Charding mechanism gear box
Limit Switches
Closing Coil Assembly
Tripping Coil assembly
Spring Charging Motor
Auxiliary Switch with link
Spring return latch
Vaccum Interupter assembly
Spout Insulator assembly (3Phase) feeder side
Spout Insulator assembly (3Phase) Bus bar side
Potential Transformer,11KV/110Volt/Rout3,100VA burden Trolly mounted with HRC Fuse
Current Transformers,50-30,5+5Amps, Class1 and 5p10,15VA,18.3kA/3Sec
TNC Switch
PF meters digital type 96x96mm
Indicating Lamps LED type
Supply & fix in repair strip type heater 80watt with control wiring suitable for indoor VCB,11 KV switch gear Panel board complete all as specified and directed
Dismantling Air Circuit Breaker 4pole/3pole, 630/800/1200/2500 Amps, 415 Volts, draw out/fixed type from location and repair /overhauling of spring drive mechanism, coil, auxiliary switch including setting of over load coil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspecting male and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective position and testing complete all as specified and directed .(Note : Spare parts will be measured and paid separately)
Material & Labour for repairs/ Overhauling/Servicing to Existing LT electric panels Indoor type of each Transformer by taking shut down from appropiate authority including checking loose connections and tight connection and cleaning inside/out side all connection, replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors, providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting (silver colour) / powder coating and testing the entire panel board after the completion of servicing up to the satisfication complete all as specified and directed (Note: The tenders quoted rate per unit shall deemed to be inclusive of taking out burnt ACB/ MCB/MCCB/ Voltmeter/ Ampiermeter /CT/ LED lamps of any type and discription etc and refixing the same, which shall be measured and paid as supply only vide relivent items of this schedule.) (i) Cleaning inside the panel and all incoming and out going feeders i.e includinging MCCB/SFU/Changeover switches/Contactors/ ACB's thorouly with help of Vaccum Cleaner. (ii) Checking the loose connections of incoming and out going feeders and rectifify the same with help of new GI nut bolts and washers (iii) Replacing the burnt out color coated PVC Sleeve of main and fedders bus bar with appropriated size of New PVC heat shrinkable sleeves -01Job (iv) Replacing Burnt out Voltmeters/Ammeters/Indicating Lamps/Hrc Fuses-01Job. (Note: New items will be measured and paid separatly) (v) Replacing burnt out control wiring of Ammeter/Voltmeter/Indicating lamps and CT'swith 2.5/1.5Sqmm copper single core,1100V grade copper conductor cable- 01Job (vi) Replacing Burnt out Bus Bar of incomming and out going feededs with approprieted size of new bus bar (Copper/Aluminum) -01Job ( Note : Bus Bar will measured and paid separately). (vi) Replacing Burnt out Insulators of incomming and out going feeders with approprieted size of new Insulators -01Job ( Note : Insulators will measured and paid separately) (vii) Spray Painting of Panel Board with one coat of synthetic enamel paint.
S&F Aluminium Bus Bar strips, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and as directed . Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs. (b) Overall length of the strip shall be measured and paid after necessary conversion into weight. (c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account. (d) Rate of Bolts, Nuts etc shall be included in quoted rate.
S&F Copper Bus Bar stips, of any size, for extention of MCCB terminals for cable terminations, inside the cable alley of LT panel board, duly supported on the FRP / DMC support insulators including necessary drilling / bending to obtain required shape and size complete all as specified and directed Note :- (a) Size of the strip shall be determined depending upon the current carrying capacity of the individual outgoing MCCBs. (b) Overall length of the strip shall be measured and paid after necessary conversion into weight. (c) Cost of drilling / bending / Grinding of the strips at site as required shall be included in the unit rate quoted. No extra payment shall be admissible on that account. (d) Rate of Bolts, Nuts etc shall be included in quoted rate.
S&F of suitable type and size FRP / DMC bus bar support insulator (Bridge Insulator) for fixing the extended aluminium/copper bars, for cable terminations, duly fixed in the body of the panel board including galvanized steel bolts , nuts, washers etc.and necessary drillings, in the panel body complete all as specified and directed
Material and labour for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage complete all as specified and directed
Supply and fix cable jointing kit Straight Through Joint for 11KV grade cable complete with Jointing material (Heat shrinkable) and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size 120 to 185 sq mm complete all as specified and as directed by Engineer-In-Charge.
All as per Item No- 103 here in before but of size 240 to 300 sq mm x 3 core
Supply and fix cable jointing kit, End Termination Joint indoor for 11KV grade cable complete with Jointing material (Heat shrinkable) and accessories suitable for 3 core XLPE armoured, alluminum conductor cable of size 120 to 185 sq mmcomplete all as specified and directed
All as per Item No- 105 here in before but of size 240 to 300 sq mm x 3 core
Supply and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 10 sqmm x 2 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old u/s damaged cables.Make : Finolex/Havells/Polycab.
All as per Item No-107 here in before but of size 16 sq mm x 4 core
All as per Item No-107 here in before but of size 25 sq mm x 4 core
All as per Item No-107 here in before but of size 35 sq mm x 4 core
All as per Item No-107 here in before but of size 50 sq mm x 4 core
All as per Item No-107 here in before but of size 70 sq mm x 3.5 core
All as per Item No-107 here in before but of size 95 sq mm x 3.5 core
All as per Item No-107 here in before but of size 120 sq mm x 3.5 core
All as per Item No-107 here in before but of size 150 sq mm x 3.5 core
All as per Item No-107 here in before but of size 185 sq mm x 3.5 core
All as per Item No-107 here in before but of size 240 sq mm x 3.5 core
All as per Item No-107 here in before but of size 300 sq mm x 3.5 core
All as per Item No-107 here in before but of size 400 sq mm x 3.5 core
Taking out carefully for old XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, from the trenches/pipes/walls keeping safely for re- use at site the crossectional area 10 to 50 Sqmm x 4 core complete all as specified and directed
Laying only old XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles the crossectional area 10 to 50 Sqmm x 4 core complete all as specified and directed ( Cable taken out Sch "A" srl item no 26.00 to be re-used.)
Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out complete all as specified and directed Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables .
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material from the site of work to outside MD land complete all as specified and directed
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I complete all as specified and directed Note :- Only compacted thickness of sand will be measured and paid separately.
S & F machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 100 mm thickness M-50 Grade not less than 0.45 mtr wide for repairing road cut/footpath carried out under Sch "A" srl item No -26.00.
Supply, laying un-reinforced precast concrete cable cover class LV type 1 flat size 250mm x 150 mmx 40 mm complete all as specified and directed.
Cutting existing road surfaces or hard standing 0.45 mtr depth (22 thick comprising bituminuous topping) for laying of pipes/cables and making good disturbed surfaces to match with existing surfaces complete all as specified and directed.
M&L for PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) for road/Hard standing cutting complete all as specified and directed
M&L for replacement 50mm High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, for road crossing of cable or for cable protection laid in trenches or above ground surface after taking out old one complete all as specified and directed . Make- Prince/Dutron/National
All as per Item No-130 here in before but for 32mm dia (HDPE).
All as per Item No-130.00 here in before but for 25mm dia (HDPE).
M&L for GI pipe ,light grade 40mm dia for road crossing of cable for cable protection or above ground surface including taking out old one complete all as specified and directed
Supply and fixing in replacement PVC insulated, stranded copper conductor of size 2 x 2.5sqmm + 1 x 1.5sqmm connecting from FRP type looping box to street light fitting connector, passing through steel tubular pole complete with fixing arrangement after taking out old u/s one complete all as specified and directed
S & F in repair looping box of size 225mm x 295mmx122 including connector blocks four way having suitable size bolt to connect upto 35 sqmm x 3.5 core cable two Nos with the help of suitable gland, thimble nuts, washers supports by flat aluminium clamps not less than 25 mm x 3mm with suitable size nuts, bolts and washers inside and outside looping box including fixing with electric pole and taking out old one of any type complete all as specified and directed. Make : Hansel , Cat ref : KF3535G. or equivalent make as approved by AGE
Scraping old paint from steel tubular poles more than 7/8/9 mtr length above ground level including street light arms, applying one coat of steel primer and one coats of aluminium paint and marking of pole numbers serially with 150 mm circle blue base sticker and pole serial no written with radium letter in white colour, 160 cm above benching of pole complete all as specified and directed
S & F in repair time switch 3 phase of capacity 63 Amps incl any type of accessories with suitable capacity of contractor after taking out unserviceable one complete all as specified and directed. Make :-(a) Timer switch -Legrand Cat No-649915, MaxiRex 4QT. (b) Power contactor - 1 No, Make-Legrand cat no-412544,Nominal rating 25A, 2 Nos Contactor.
Taking down old conventional SV/MH street light fitting of any make wattage and S&F LED 120 Watts in Aluminium PDC housing, toughened glass cover in IP66 protection including making electric connection from Loop box to fitting complete all as specified and directed Make : Bajaj Cat No-BRTFG120WLEDHXE or C&S Cat- LTESSI120WLED or Crompton Cat No-LSTP-120-CDL.
All as per Item No 138 here in before but LED 60 Watts complete all as specified and directed. Make : Bajaj Cat- BRTFG60WLEDV3 or C&S Cat- LTESSI60WLED or Crompton Cat No-LSTP-60-CDL
All as per Item No 138 here in before but for street or building security light with LED 45 Watts complete all as specified and directed . Make : Bajaj Cat No- BRTFG45WLEDV2 or C&S Cat - LTESSI45WLED or Crompton Cat No- LSTP-45-CDL.
Taking down old conventional SV/MH/Halogen flood light of any make wattage and S&F LED flood light luminaires 350 Watts with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 including making electric connection from Loop box to fitting complete including taking out old u/s light fitting complete all as specified and directed Make : Bajaj, Cat : BARFEG350W LED or C&S Cat- LTEFI350WHPLED or Crompton Cat no LSFO-350-CDL/60.
All as per Item No 141 here in before but LED flood light luminaires 200 Watts complete all as specified and directed. Make : Bajaj, Cat ref : 169783 BARFEG 200W LED or Crompton Cat no LSFO-200-CDL/60. or C&S Cat- LTEFI200WHPLED.
All as per Item No 141 here in before but LED flood light luminaires 60 Watts complete all as specified and directed. Make : Bajaj Cat-BJFL60WLEDI or Crompton Cat-LFL-60-CDL/60.
S&F in replacement of street light bracket bend to shape made as required of 40mm dia 1 mtr long GI pipe light grade fixed to pole/ Wall with flat iron clamp of size 40x6mm two numbers with the help of nuts and bolts for fixing of street light fitting including making all electric connection including taking out old one complete all as specified and directed
M&L for Replacement of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 metre Long) and applying one coat of steel primer and one coat of aluminium paint and pole ser number as per existing number including Earth work, excavation, foundation, PCC 1:3:6 type C-2 and coping in PCC 1:3:6 type C-1 of pole including taking out old unserviceable/broken pole by cutting or digging complete complete all as specified and directed
M & L for earthing complete with Galvanised steel earth plate eletrode 60cmx60cmx6mm thick buried directly in ground vertically to (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised Iron Strip of size 32x6mm size, by means of Bolts, Nuts, Check Nuts and washer made of GI or Steel Earth connecting with test point, provision of Charcal and salt in alternate layers, watering pipe 20mm dia medium grade MS funnel with jali, PCC M-15 Type B-1 in pit with XPM not elss than 4Kg per Sqm and Earthpit with cover returning, filling, removing excavated material all as specified in electrical plate No 3 of SSR Part-I making good excavated surfaces such as hard standing refixing machine pressed precast concrete interlocking paver blocks removed during excavation on earthpit to mach existing surfaces after taking out old/unserviceable one complete and testing on completion complete all as specified and directed
M & L for Galvanised iron strip 32 x 6mm burried in ground or fixed on walls/floor with suitable saddles and screws beyond 7.5mtr of earth lead connecting with test point after taking out old/unserviceable complete all as specified and directed
S & F test point terminal block for connecting the earth pit and down conductor or Aluminium strip, made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw after taking out old/unserviceable complete all as specified and directed
NOEL ENGINEERS
Shree Ayyappa Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .