Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹41.8 L+₹1.7 L (4.32%)Rejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L2₹50.0 L+₹9.9 L (24.8%)Rejected-Finance | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L3₹42.0 L+₹1.9 L (4.82%)Rejected-Finance A 1 DEEPMALA BUNGLOW CADILLA ROAD GODASAR AHMEDABAD CITY | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 5 | L4₹44.3 L+₹4.3 L (10.7%)Rejected-Finance 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L4 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
₹45.8 L
EMD Value
₹91,620
Closing Date
8 May 2023, 6:00 pmClosed
HQ CWE Allahabad
HQ CWE New Cantt Allahabad
PROVISION OF GENERATOR SET FOR 600 SEATER AUDITORIUM CUM CINEMA HALL AT NEW CANTT UNDER GE (WEST) PRAYAGRAJ.
2023_MES_586711_1
81742/W/E8
Open Tender
Civil Works
Item Rate
180 days
Prayagraj
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (West) Prayagraj
₹91,620
Yes
16 Jun 2023
23 Mar 2023
11 May 2023
24 Mar 2023
8 May 2023
24 Apr 2023
Amount
Silent/containerzed diesel engine driven generating set complete to give an output of 400 KVA AC 415 Volts, 50 Cycles per second, 3 phase 4 wire supply with power factor 0.8, 1500 RPM diesel engine and alternator mounted on common base plate, anti vibration rubber mounting pad (AVM Pads "B" series) complete in all respect with and including accessories and components as specified below including sound proof integral accoustic enclosure for 400 KVA Gen Sets ECO friendly and as per Ministry of Environment, forests notifaction 17 May 2002 complete including, emergency stop button, illumination inside canopy, Temperature sensor for high temp safety, exhaust fan etc complete as per IS 4722, AMF type with relay panel for automatic starting on mains failure. (a) Diesel Driven Engine (Prime mover):- Multi cylinder, vertical/horizontal, 4 stroke cycle, suitable for 400 KVA alternator, water cooled conforming to BSS- 649 rated for continuous running diesel engine suitable to FF matching BHP at 1500 RPM as per latest ISS/BSS, capable of taking 10% over load for any one hour in any 12 hour running, complete with and including following accessories:- (i) Fuel filter (ii) Governor ( Electronic) (iii) Complete battery set with lead & lugs as recommended by manufacturer. (iv) Lubricant oil cooler (v) Lubricant oil pump. (vi) Lubricant oil filter (vii) Digital oil pressure gauge
(viii) Any other parts as prescribed by manufacturer for its good functional performance. (ix) Battery charging alternator suitable for charging Batteries. (x) Dry type air filter (xi) MS channel fabricated frame rigidly welded suitable for receiving the diesel engine and alternator and anti vibration pads. (xii) Coupling guard. (xiii) Exhaust pipe fully extended to exhaust gases outside the acoustic enclosure including silencer and necessary insulation lagging all as per manufacturer's recommendations. (xiv) Fuel tank of MS sheet and of capacity for 12 hours running on full load with inlet and outlet connection, filling cap, drain valve, air vent with caliberated scale on outer surface, floor mounted with suitable angle iron supports. (xv) Digital type RPM meter with hour meter. (xvi) Self starter of suitable size (xvii) Turbo charger (xviii) In line mono block (xix)Fuel pump (xx)Digital type Coolant temp gauge. (xxi)Self starter with auto electric start accessories (xxii) Engine safety low lubricant oil pressure and high coolant temperature. (xxii) Test certificate
(xi) Auto change over complete with suitable size power contactor of size upto 400 Amps with tripping relay complete. (xii) Engine starting relay. (xiii) Frequency stabilizer auto mechanism to maintain the supply. (xiv) Battery charger suitable to charge the battery of 12 V/24 Volt DC with buck/ boost system - 02 No (e) Supply & install of Acoustic Enclosure suitable for 400 KVA DG set as under (i) Fabricated out of CRCA sheet of suitable thickness as per manufacture design. Polyster based powder coated internaly and externaly with lockable type door handle. All nuts and handles shall be zinc coated. (ii) The doors are gasketed with EPDM gaskets. (iii) Sound proofing with high quality rock wool/ mineral wool confirming to IS 8183 of 50mm thickness and density at 96 Kg/M3 covered with fiber glass cloth and perforated powder coated sheet specialy designed allenuators (Sound controller) at air entry and exit of the container noice level shall be not exceed 75 Db at 1 meter distance as per CPCB/Government of India Norms.
(iv) Adequate ventilation to meet air requirement for combustion and heat removal with provn of a blower. (v) Emergency stop push button outside the container. (vi) Provn of light inside the canopy i.e. providing LED light fitting 1 x20 Watt with wiring and control switch. (f) MOUNTING ARRANGEMENT- Prime mover and alternator shall be mounted on skid mounting type base frame fabricated from ISMC channel or in sheet metal providing common bed for engine and alternator directly coupled together the base frame has provision for grouting on foundation bolt as well as fixing on vibration mounts provision is made in base frame for tilting arrangement of DG set as recommended by manufacturer. The base frame shall have provision of lifting hook for convenient lifting of complete set ie along the canopy engine and alternator. (g) cost of constr of PCC plinth of DG Set as per manufuacture design and recommendation deemed to be included in this item.
M&L for Earthing complete with GI earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground ( earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6mm thick by means of bolts, nuts, check nutsa and excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B1 using (20 mm graded stone aggregate ), mild steel frame made out of angle iron of size 40 mm x 40mm x 3mm thick duly painted with two coats of synthetic enamal paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thicks CI cover with handle, watering arrengement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 40mm dia light grade GI pipe for lead protection in and including alternate layer of charcoal dust and comman salt complete all as shown in electrical plat no. 3 connected to earthing test point all as specified and indicated including testing on completion as directed. Note:- If the desired earth resistance is not found, eathing shall be redone by the contractor at no extra coast to the department
Excavating in trenches in soft/loose soil n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc exc 10 sqm on plan and n.exc 1.5 m in depth and getting out as I soft/ loose soil complete all as specified and directed
Returning filling in, including spreading levelling, watring and well ramming in layers n exc 25 cm complete all as specified and directed
Removing excavted material n exc 50 m and depositing where directed at level n exc 1.5 m above the staring point as soil complete all as specified and directed.
Sand cushioning (dry sand) to under ground cable for cable protection in layers of 23cm thick ( 8 cm thick before laying of cable and 15cm thick after laying of cable) in trenches complete all as specified & directed. Note:- Only puned layers shall be measured.
M&L for old size brick well burnt sub class 'B' Designation 75, laid flat, for cable protection complete all as specified and directed.
S&F 100 mm dia Galvanised steel tubing light grade with all necessary fittings laid in trenches, fixed to walls, poles, under road/ floor etc for cable protection, complete all as specified and directed.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm of 3.5 core complete all as specified and directed.
Electromech Engineers
A ONE ENGINEERING
M/S VIJAY SINGH
BRITE INDUSTRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .