Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
| 4 | Not Admitted-Fee/PreQual/Technical 111 90 VIJAY PATH MANSAROVAR JAIPUR RAJASTHAN 302020 | JAIPUR | RAJASTHAN | 302020 | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
Tender Value
₹11 L
EMD Value
₹11,000
Closing Date
4 Aug 2021, 5:00 pmClosed
SE CIVIL JVVNL
SE CIVIL JVVNL RAM MANDIR BANI PARK JAIPUR
Renovation of Honble Chairman Chamber at RERC building, Sahkar Marg Jaipur
2021_JVVNL_234407_21
NIT NO.01 JPR/2021-22
Open Tender
Civil Works
Percentage
30 days
Jaipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
AO JCC JVVNL JAIPUR, PROCESSING FEE MD RISL JAIPUR
₹11,000
Yes
10 Aug 2021
30 Jul 2021
6 Aug 2021
30 Jul 2021
4 Aug 2021
30 Jul 2021
Amount
PART- B (Item Rate Basis)
Dismantling of Wall Paneling i/c all vertical and horizontal Members, ply, veneer, glass wool all electric fixtures like downlighting 2'x2' light etc complete and disposal of unwanted material away from site etc. Complete in all respect
Removing refixing of Air conditioners of capacity 1.00/1.5/2.00 tone including servicing of unit charging of gas up to required capacity including necessary repair of walls cost of copper pipe , cable switch socket as per site needs and making of the unit in running conditions.
Charges for cutting almirah shutter requires for their shifting/placing in other position. ( per cut)
Dismantling & Re-installation Labour work for existing sprinklers from main ceiling to false ceiling level by cutting & dismantling of pipe and socket and refixing the same. Incl painting of Red colour.
Dismantling & Re-installation of old smoke detectors from main ceiling level to false ceiling level by providing necessary joints in wiring through 2x1.5 sq. mm copper cable, Incl, re-commissioning of the smoke detectors with the existing control panel and making the system fucctional.
supply & Fixing of unbraided steel flexible of 1.5 Meter long with all brackets for fitting on False ceiling incl steel rosette plate. (Make Tyco/HD). UL Listed.
Supply & Fixing of multistrand copper flexible wire FR type (Make Poycab/JMP) ISI marked.
P/F wooden partition in board hollow core made of 9 mm oply both side with 4mm veneer of approved shade & superior quality on batten grid made with 19 mm board of size 50mmx38mm with malamine polish complete with provision of door and windows ( for which glass panel if any be deducted & paid separately)
Dismantling of stone work of window i/c sill, chajja Kangoora , Kanwalies , Dasa etc complete in all respect with necessary T & P
S&F stone Bansi Pahad pur pink stone/equivalent stone Dasa (sills) find dressed up to 15cm thickness including as per drawing out stone work type ornamental work complete labour material, T&P fixing charges with labour and material in existing building complete lift up to the height of 5mtr. Depth of carving about 1/2" or as per drawing enclosed of the same complete as per direction of Engineer in charges. ( Note measurements of the Dasa shall be out of outer width x Length of the Dasa) (A) Cut Stone 3" Thickness
(B) Top Stone up to 50mm Thick
S/F Bansi Pahad pur pink stone/equivalent stone kangoora find fressed and onamental cut work up to 1/2" depth or as per enclosed drawing the thickness of the stone shall be paid separately), complete labour material T&P lift up to the 5Mtr. And material required for the fixing in existng windows proch etc. complete as per direction of Engineer in charges.
S/F Bansi Pahad pur pink stone/equivalent stone stone side kanwalies (Jams) up to 3" thickness find dressed including minor cut stone work in faces. Complete labour, material T&P and fixing charges (including material and T&P) in existing building complete as per enclosed drawing sand direction of Engineer in charges for Dubari,tibari, Jali & Jharoka.
S/F of Bansi Pahad pur pink stone/equivalent todis for tibaries or Dubaries and cut stone work exposed 9''x6'' below ornamental sill stone cut stone work as per drawing thickness of the todi shall respect including fixing etc. as per direction of Engineer in charge
S/F bansi Pahad Pur Pink stone/ equivalent chajjas about 1' to 2' projected portion having thickness at the support 3"and the edge of the chajja about 2"round in shape and the end and clear water drop by mean of grooving about spacing from the edge 11/2"with cashing of the chajja minimum 6" to 8" below the galat and above the lintel as per direction of engineer in charge complete as per enclosed drawing. (Exposed surface to be measured for payment)
Providing and fixing in position P.O.P. false ceiling over G.I. metal frame work of appd. quality and wiremesh. The main G.I. frame ( 24g x 2” x 1”) shall be at 2’6” c/c and intermediate frame ( 21/2” x ¾” x 24g) shall be at 15” c/c. The main G.I. member to be hanged with help of G.I angle of 1" x 1" x 24 gauge and additional M.S flats 3/4" x 1/8" (Redoxide painted) and s.s dash fasteners including all necessary work required. Expanded metal mesh (0.07 Kg/Sft) shall be firmly stretched and screwed to the intermediate frame with G.I. washers and average 20 mm plaster of paris to be applied on in two layers. Necessary provisions and marking shall be made for cut outs for air conditioners supply, return air grills, slits, light fittings, smoke detector and music speaker by providing 6mm bwp ply template etc. The job shall include making steps ceiling, vertical surfaces, cove, taper ceiling, pelmet facia etc. as per detail in drg. the job shall also include hardwood frame required for fixing AC Grills. (As laid finished POP surface area shall be measured for billing).
Providing edge moulding to sand pink sand stone ( Bansi pahadpur) complete as per design approved by Engineer. (a) upto 20mm thick
(b) 20mm to 40mm thick
(c) 40mm to 75mm thick
Covering of RCC Rectangular column in circular Shape of dia 26.5"by wood work (i)Covering of RCC Rectangular column of size 20"x12"x 123" surface with 19mm ISIs marked ply for supporting of Vertical strips of size 3"x123"(12 Nos) and horizontal strips of size 25"x12"(12 Nos ) & 12 1/2"x12'(12 Nos) with extra strip of size "x6"(approx 24Nos) outer covering with 8mm thick flexible ply for giving circular shape of dia 26.5".
Removing, refixing of ceiling fan including their proper cleaning,overhauling & greasing, providing blade set, capacitor,shaft and bushes etc. required if any
P & F of IP20 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Downlight with die-cast aluminum housing & Heat Sink for heat dissipation, high purity reflector with external driver having efficiency > 85% and in compliance to IEC standards. Power Consumption of ≤ 7W/ 10W / 15W / 18W with ~ 500 / 750 / 1100 / 1250 lumens, System Lumen efficacy of 70 lm / watt output suitable to replace 1x18W / 2x18W / 2x 26W CFL Downlights, life time of 50000 Burning Hours with 70% of intial Lumen maintaned. CCT 3000°K , 4000°K & 6000°K. Fixture shall be CE compliance.LED Downlight 6/7W
Welding work for new slab reinforcement to old slab reinforcement welding length upto 15cm due to adjoining the new RCC slab to old RCC slab including dismantling of old RCC slab core upto 150mm to 200mm wide in full length by mechanical means. The job includes also all labour, scaffolding, disposed of malba away from site & all T&P complete in respect.(bars of dia upto 25mm)
SHREE VISHWAKARMA BUILDERS
SHREE VISHWAKARMA BUILDERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .