Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
23 Oct 2021, 2:00 pmClosed
Executive Engineer, JPDCL,ED,Kathua
Office of the Executive Engineer, JPDCL,ED,Kathua
Laying of HT/LT Line for Buildings Constructed under NABARD on Turnkey basis at various locations in respect of O M Division, Kathua(JPDCL)
2021_PDD_141073_1
KED/21 of 2021-22 Dt.23.09.2021
Open Tender
Electrical Works
Turn-key
20 days
kathua
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Executive Engineer, JPDCL,ED,Kathua
Exempted
3 Nov 2021
24 Sept 2021
25 Oct 2021
24 Sept 2021
23 Oct 2021
24 Sept 2021
24 Sept 2021 - 29 Sept 2021
Amount
Creation of 25KVA Sub Station at Sander Basholi on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
11/0.433kV, 25KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al. wound ).
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
95mm² Single Core Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long ST Pole(410 SP 33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for LA,set/G.O set/Horn Gap set
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Pre-Fabricated LT Disconnector Fuse Set
Cement Bottoming of Pole with 1:2:4 mix as per RE Standard .5cum/pole
Danger Plates with Clamps
Laying of HT Line at Sander Basholi on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
9.0Mtr ST Poles(410-SP-33)
GI V Cross Arms with Top Bracket including Clamps
GI Channel X-arm including Clamps and Braces
30 mm² ACSR Weasel Conductor
PG Clamps for 30sqmm ACSR Weasel Conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti Climbing Devices
Earthing Complete by GI Pipe 40mm or GI Rod 20mm 2.5 Mtr Long Through GI strip
Red Oxide paint
Aluminium Paint
Cement Bottoming of Pole with 1:2:4 mix as per RE Standard .5cum/pole
Aluminium Jointing Sleeves
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Laying of LT Line at Sander Basholi on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
8.0 Mtr ST Pole(410-SP-15)
GI U Clamp for Shackle Insulators
16kN Polymer Shackle Insulators
30 mm² ACSR Weasel Conductor
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti Climbing Devices
Earthing Complete by GI Pipe 40mm or GI Rod 20mm 2.5 Mtr Long Through GI strip
Red Oxide Paint
Aluminium Paint
Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum per pole
Aluminum Jointing Sleeves
LT Line Spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Laying of LT Line at Prehta Basholi on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
8.0 Mtr ST Pole(410-SP-15)
GI U Clamp for Shackle Insulators
16kN Polymer Shackle Insulators
30 mm² ACSR Weasel Conductor
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti Climbing Devices
Earthing Complete by GI Pipe 40mm or GI Rod 20mm 2.5 Mtr Long Through GI strip
Red Oxide Paint
Aluminium Paint
Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum per pole
Aluminum Jointing Sleeves
LT Line Spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Creation of 25KVA Sub Station at Dharamkot(Ramkot) on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
11/0.433kV, 25KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al. wound ).
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
95mm² Single Core Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long ST Pole(410 SP 33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for LA,set/G.O set/Horn Gap set
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Pre-Fabricated LT Disconnector Fuse Set
Cement Bottoming of Pole with 1:2:4 mix as per RE Standard .5cum/pole
Danger Plates with Clamps
Laying of HT Line at Dharamkot(Ramkot) on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
9.0Mtr ST Poles(410-SP-33)
GI V Cross Arms with Top Bracket including Clamps
GI Channel X-arm including Clamps and Braces
30 mm² ACSR Weasel Conductor
PG Clamps for 30sqmm ACSR Weasel Conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti Climbing Devices
Earthing Complete by GI Pipe 40mm or GI Rod 20mm 2.5 Mtr Long Through GI strip
Red Oxide paint
Aluminium Paint
Cement Bottoming of Pole with 1:2:4 mix as per RE Standard .5cum/pole
Aluminium Jointing Sleeves
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Laying of LT Line at Bakhta(Barnoti) on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
8.0 Mtr ST Pole(410-SP-15)
GI U Clamp for Shackle Insulators
16kN Polymer Shackle Insulators
30 mm² ACSR Weasel Conductor
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti Climbing Devices
Earthing Complete by GI Pipe 40mm or GI Rod 20mm 2.5 Mtr Long Through GI strip
Red Oxide Paint
Aluminium Paint
Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum per pole
Aluminum Jointing Sleeves
LT Line Spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Laying of LT Line at Saber(Basholi) on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
8.0 Mtr ST Pole(410-SP-15)
GI U Clamp for Shackle Insulators
16kN Polymer Shackle Insulators
30 mm² ACSR Weasel Conductor
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti Climbing Devices
Earthing Complete by GI Pipe 40mm or GI Rod 20mm 2.5 Mtr Long Through GI strip
Red Oxide Paint
Aluminium Paint
Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum per pole
Aluminum Jointing Sleeves
LT Line Spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Laying of LT Line at Sukrala(Billawar)on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
8.0 Mtr ST Pole(410-SP-15)
GI U Clamp for Shackle Insulators
16kN Polymer Shackle Insulators
30 mm² ACSR Weasel Conductor
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti Climbing Devices
Earthing Complete by GI Pipe 40mm or GI Rod 20mm 2.5 Mtr Long Through GI strip
Red Oxide Paint
Aluminium Paint
Cement Bottoming 1:2:4 mix as per REC Standards 0.5cum per pole
Aluminum Jointing Sleeves
LT Line Spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Laying of LT Line at Janglote on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:
8.0 Mtr PCC Pole(WL 200Kg)
GI U Clamp for Shackle Insulators
16kN Polymer Shackle Insulators
30 mm² ACSR Weasel Conductor
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti Climbing Devices
Earthing Complete by GI Pipe 40mm or GI Rod 20mm 2.5 Mtr Long Through GI strip
Stone Pad (300mmX300mmX75mm)
Aluminum Jointing Sleeves
LT Line Spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
M/S SUKRALA ELECTRICAL WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .