Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹7.3 L+₹41,442.46 (5.98%)Rejected-Finance KEOTA NO 2 SAHAGANJ HOOGHLY | HOOGHLY | HOOGHLY | WEST BENGAL | L2 | Rejected-Finance Being L2 Bidder | |
| 3 | L3₹7.6 L+₹70,462.79 (10.2%)Rejected-Finance | L3 | Rejected-Finance Being L3 Bidder | |
| 4 | L4₹7.7 L+₹72,219.50 (10.4%)Rejected-Finance | L4 | Rejected-Finance Being L4 Bidder | |
| 5 | L5₹7.8 L+₹90,398.03 (13.0%)Rejected-Finance | L5 | Rejected-Finance Being L5 Bidder |
| Sl No | Description | Qty | Unit | R.K. ENTERPRISE L2 | B.S.M ELECTRICAL L5 | SANDIP TRADERS L1 | CHANDA CONSTRUCTION L4 | SHATABDI ENGINEERING AND CONSULTANCY L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm; Color :- ph- Red/yellow/blue ,N - Black) single core stranded 'FR' PVC insulated & unsheathed copper wire
(Brand approved by EIC) in 20mm size PVC rigid conduit 'FR'
(Precision make), with 1x22/0.3 (1.5 sqmm ,color- E- green) single core stranded 'FR' PVC insulated & unsheathed copper wire for
ECC, to light/fan/call bell points with Modular type switch
(Brand approved by EIC) fixed on Modular GI switch board
with top cover plate and 2 no. suitable size “Ph & N” copper
bar & earthing attachment fixed on wall incl. mending good
damages to original finish.[E-24,1-C]
Average Run - 8 Mtrs | 46 | Nos | 911 ₹41,906 Lowest | 970 ₹44,620 | 1,100 ₹50,600 | 970 ₹44,620 | 960 ₹44,160 |
| 2.00 | Supplying and fixing 160 A,415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc as per GS [ Make L& T /Havells/HPL]. [D-2, 3a] | 1 | Nos | 9,395 ₹9,395 | 9,395 ₹9,395 | 9,395 ₹9,395 | 9,395 ₹9,395 | 9,375 ₹9,375 Lowest |
| 3.00 | Supply of 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables(A2XWY) for Working Voltage up to 1100 Volts of following sizes [ Make - Gloster/KEI/Polycab]
4 Core 70 Sq. mm | 230 | mtr | 716 ₹1,64,680 | 740 ₹1,70,200 | 522 ₹1,20,060 Lowest | 740 ₹1,70,200 | 746 ₹1,71,580 |
| 4.00 | Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring
surface duly rammed. [ F-2,1b ] | 150 | mtr | 161 ₹24,150 Lowest | 172 ₹25,800 | 170 ₹25,500 | 170 ₹25,500 | 170 ₹25,500 |
| 5.00 | Laying only Cable upto 70 sqmm through existing RCC/Hume/ GI
Pipe/open masonary trench for single, 2, 3, 3½ & 4 core [ F-1,3a] | 30 | mtr | 56 ₹1,680 | 60 ₹1,800 | 50 ₹1,500 Lowest | 56 ₹1,680 | 56 ₹1,680 |
| 6.00 | Laying of cable above 3½ core 50 sqmm and upto 3½ core 90
sqmm on wall/surface including S & F MS clams with earthing
attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as
necy., mending good damages and painting ,[F-1, 2 d ] | 50 | mtr | 78 ₹3,900 | 83 ₹4,150 | 75 ₹3,750 Lowest | 78 ₹3,900 | 78 ₹3,900 |
| 7.00 | Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
4Core 70 Sq. mm [F-4,7C] | 2 | set | 200 ₹400 Lowest | 212 ₹424 | 212 ₹424 | 200 ₹400 Lowest | 200 ₹400 Lowest |
| 8.00 | Finishing the end of following XLPE/PVC armoured cables by
crimping method incl. supplying and fixing solderless socket
(Dowels make), tapes, anticorrosive paste & jointing materials :
4Core 70 Sq. mm [F-5,8b,xvii] | 4 | set | 247 ₹988 Lowest | 263 ₹1,052 | 263 ₹1,052 | 247 ₹988 Lowest | 263 ₹1,052 |
| 9.00 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS.
65 mm dia [F-6,11e) | 30 | mtr | 391 ₹11,730 Lowest | 418 ₹12,540 | 416 ₹12,480 | 416 ₹12,480 | 391 ₹11,730 Lowest |
| 10.00Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works | ||||||||
Tender Value
Refer Docs
EMD Value
₹15,698
Closing Date
10 Jun 2025, 2:00 pmClosed
Executive Engineer,Hooghly Electrical Division,PWD
3rd Floor Purta Bhavan Sarat Sarani, Kodalia, Hooghly
EI work at 1st floor of ART centre of Imabara District Hospital Hooghly under Hooghly Electrical Sub- Division I ,PWD...E.I work.
2025_WBPWD_854446_1
WBPWD/EE/ HED / NIeT-04 of 2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
Hooghly
Please refer Tender documents.
4 documents required · 4 mandatory
₹15,698
O/o the Exe Eng,Hooghly Elec Divn,PWD
7 Sept 2026
28 May 2025
12 Jun 2025
28 May 2025
10 Jun 2025
28 May 2025
30 May 2025
Amount
Distribution wiring in 2 x 22/0.3 (1.5 sqmm; Color :- ph- Red/yellow/blue ,N - Black) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm ,color- E- green) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.[E-24,1-C] Average Run - 8 Mtrs
Supplying and fixing 160 A,415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc as per GS [ Make L& T /Havells/HPL]. [D-2, 3a]
Supply of 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables(A2XWY) for Working Voltage up to 1100 Volts of following sizes [ Make - Gloster/KEI/Polycab] 4 Core 70 Sq. mm
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed. [ F-2,1b ]
Laying only Cable upto 70 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core [ F-1,3a]
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting ,[F-1, 2 d ]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 4Core 70 Sq. mm [F-4,7C]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4Core 70 Sq. mm [F-5,8b,xvii]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS. 65 mm dia [F-6,11e)
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction)
19mm dia 3mm thick Polythene Pipe [E-2,B1.b]
25 mm dia 3mm thick Polythene Pipe [E-2,B1.c]
32 mm dia 3mm thick Polythene Pipe [E-2,B1.d]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [E-9,1, s ]
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [E-9,1, v ]
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [E-9,1, y ]
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC [E-9, C1,d1]
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC [E-9, C1,g1]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-5,9]
2.5 sq mm [F-5,9,i]
4 sq mm [F-5,9,ii]
6 sq mm [F-5,9,iii]
10 sq mm [F-5,9,iv]
16 Sq.mm [F-5,9,v]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall & 3 mm thick bakellite cover as per GS 175 x 100 x 65 [E-4 ,11,c]
Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-19, 15]
Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-18 ,13]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17,5.a]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [E-17,5.b]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works . [ E-17, F ]
6 Modular Board [E-17,F.1b]
2 Row 12 Module [E-17, F.1e]
Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required [E-17, F.3a]
Supply & Fixing 240 V 16 A modular key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required [E-17, F.3b]
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17, F.4a]
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17, F.4b]
SUBHEAD - 2 SUPPLY & FIXING OF VTPN,PDB,SPNDB
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS as per direction of EIC. 4 Way ( Up to 160 A ) Make - Legrand, Enclosure (607913) [D-11 , 15]
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment For 4 Way VTPN ,VERTICAL [D-12,16 ]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection [ Make - Legrand / Schneider/L&T) as per direction of EIC.]. 160 A [D-8, 10]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 6 way - Legrand Enclosure (607716)/SIEMENS- Enclosure (8GB32202RC06) [D-10,14]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+12 Way [Siemens Enclosure(8GB32102RC14)/Schneider Enclosure (A9HSND12) or equivalent model of Legrand) as per direction of EIC [D-10,13]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ] 63 A FP [D-5,6]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ] 6-32 SP [ D- 6, 7 ]
SUBHEAD - 3 SUPPLY & FIXING OF LED TUBE LIGHTS & L CLAMP
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [ C-2, 17 ]
Suppy of twin fittings [Philips make Cat No. TMC-501 P2xT-LED 22W P3242 or equivalent make CG[W865 T8 AP I/LTT8-20 ] as approved by E.I.C incl. 2 nos. 20W Master LED Tube [Make- Philips /CG as approved by E.I.C]
SUBHEAD - 4 : SUPPLY & FIXING OF CEILING FAN & RC FAN CLAMP
Supply of ac ceiling fans of 1200mm sweep with burst-proof P2/S3 Capacitor complete with all accessories without regulator. ( Make - Usha-Striker or equivalent model of Havells/CG- HS PLUS /Orient(SUMMER KING XL) as approved by E.I.C)
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) [ D-14 ,29]
SUBHEAD - 5 : TIMER ROOM AC & COMPOUND LIGHT
S&F of 250V timer DB (equivalent to 12 way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with IP43 protection comprises with 1 nos 20/25A DPMCB(C-curve 10ka) and 1 no 24 hr digital time switch(L&T,GIC) and 1 no 18A(L&T MNX 18-3P, cat no.- CS94101) power contactor, Starter(Northe West 11A to 18A ) complete with internal wiring (1.5 sq.mm - control wiring.4.0 sq.mm - power wiring) with suitable size of copper wire including 1 no toggle switch(For Auto/Manual/Off), with Door locking arrangement by common panel keys as used in panel and 2 nos LED( RED color AC ON , GREEN color - AC OFF must be written in engraving/steel/plastic plate by black color) indicator and earthing attachment as per direction of EIC (Make:- L&T/SIEMENS/ABB/Legrand or equivalent make as approved by E.I.C)
SUBHEAD - 6 : COMPOUND LIGHT
Supply & Fixing of 240V, 90 W LED Street light luminarie complete with all accessories and equipped with IP66 Protection ( Philips/Bajaj//wipro - model skyline LR02 -102 XXX -57-G2 90W) on existing MS Pipe/Mini Pole as per direction of E.I.C
S & F mini pole on roof top by 80 mm dia., 2 Mtr. Long GI(M) pipe medium quality (Bansal/Jindal make) incl. making cc (6:2:1) muffing 600x600x750 mm in size with 3 mm thick neatly finished cement plaster incl. S & F 8”x6”x4” C.I. looping cable box incl. S & F 40 mm. dia. G.I.(M) 1.5 Mtr. Long arm bracket for fixing flood light & neccy connection by 2x 1.5 sq mm Cu wire. This is incl. painting as per GS.
S&F 50 mm. dia 1.5 mtr. long detachable type G.I. Single arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC.
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps [I-2,16.a ]
Painting of any steel/ iron surface with 2 nos. of aluminium coats of paint over 1 coat of RO priming with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint for single/double arm bracket
Supply & laying of 4 Core XLPE (A2XWY/A2XFY) Insulated Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make---Gloster/KEI/Polycab] 4 Core 6.0 Sq. mm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4C 6.0 SQ.MM [F-4,7C]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. 4C 6.0 SQ.MM [F-5,8b,X]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: [G-1,2a] By TATA-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe [G-2,3a]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [G-2,4b]
Add GST 18 %
Add Labour Cess 1%
R.K. ENTERPRISE (BID ID -6503732)
SHATABDI ENGINEERING AND CONSULTANCY (BID ID -6545301)
CHANDA CONSTRUCTION (BID ID -6531475)
B.S.M ELECTRICAL (BID ID -6507942)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .