Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 266 UTTAMNAGAR NDA ROAD PUNE 411023 | PUNE | MAHARASHTRA | 411023 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
18 Jan 2020, 9:00 amClosed
GE I R AND D GIRINAGAR PUNE
GE I R AND D GIRINAGAR PUNE 411025
PROVN OF CERTAIN B R AND E M WORKS AT NAVAL EXPERIMENTAL BAY CERTAIN ADDN ALTN B R AND E M TO FINANCE SECTION E TICKETING ROOM ADDN ALTN OF ONE ROOM OF NTC P 180 FOR CREATION OF MECHRONICS LAB CERTAIN REVENUE WORK AT MILIT GIRINAGAR PUNE
2019_MES_306096_1
GE I R AND D GNR TOKEN 78 OF 2019 20
Open Tender
Civil Works
Works
180 days
GE I R AND D GIRINAGAR PUNE
PROVN OF CERTAIN B R AND E M WORKS AT NAVAL EXPERIMENTAL BAY CERTAIN ADDN ALTN B R AND E M TO FINANCE SECTION E TICKETING ROOM ADDN ALTN OF ONE ROOM OF NTC P 180 FOR CREATION OF MECHRONICS LAB CERTAIN REVENUE WORK AT MILIT GIRINAGAR PUNE
6 documents required · 6 mandatory
₹500
GE I R AND D GIRINAGAR PUNE
₹98,000
Yes
21 Jan 2020
12 Dec 2019
20 Jan 2020
12 Dec 2019
18 Jan 2020
5 Jan 2020
12 Dec 2019 - 7 Jan 2020
Amount
Surface excavation not. exc 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified.
Rough Excavation n exc 1.5m deep and getting out in soft/ loose soil complete all as specified
Excavating in trenches in soft/loose soil, n.exc. 1.5m wide and n.exc 1.5 in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n.exc. 10 sqm on plan and n.exc 1.5m in depth and getting out.
Returning filling in including spreading, levelling, watering & well ramming in layers n.exc 25cm each.
Removal of excavated material n.exc 50M distance & deposited where directed at a level n.exc 1.50m above the starting point as directed by Engineer-in-Charge.
M&L for cement concrete (1:4:8) type D2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete all as specified and directed.
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises all as spd and directed
M&L for granite(of any type) work(table rubbed and polished) cooking platform and like set in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to matach with shade of granite thickness of granite 18 to 20mm
S&F, Non skid ceramic tiles Coloured 7 to 8 mm (square/rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm in floors etc set and jointed in neat cement slurry & pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 .
M&L for coloured glazed ceramic tiles 350x250x7mm / 450 x 350 x 7mm thick in dado/ skirting ,set and jointed in neat cement slurry & pointed in coloured cement includind 10mm thick backing coat in cement moter 1:4.
M&L for Rendring 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 on walls ,finishing surfaces even and smooth w/o using extra cement. Note : 1. mixed with water proofing compound @ 3% by weight of cement complete all as specified. 2. Water Proofing compound shall be measured and paid for seprately as "Supply Only"
M&L rendering 5 mm thick in CM (1:3) on concrete surface in ceilling finished even & smooth w/o using extra cement.
M&L for rendering 15mm thick on stone masonry surfaces or surfaces other than fair face of brick work in CM 1:6, finishing surfaces even and smooth without using extra cement complete all as specified.
Preparation of existing surfaces on walls ,ceiling , fins , fascias etc , and applying two coats of weather proof exterior paint (Apex Ultima ),white or tinted ,over a coat of primer including necessary scaffolding all as specified and directed.
M&L for compete removal of new surfaces wall applying two coats of OBD, white or tinted, over 3mm thick wall care putty all as directed .
M&L for preparation of new plastered or unplastered ceiling surfaces and applying one coat of white wash as specified and directed by Engr -in-Charge.
M&L for 75mm thick PCC 1:3:6 type C-2 (40mm graded stone aggregate) finished even and smooth, without using extra cement as in plinth protection and path etc complete all as specified and directed.
Taking down chowkats or frame with shuters (without taking off shutters from the frames) not exc 1.5 Sqm each and removing to stores
M&L forming jambs, Cills etc. in cement mortat 1:6, to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work complete all as specified and directed.
S&F three track sliding window with 4mm thick tinted glass in two shutter and one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing including good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engr-in-Charge. Series of aluminium section as per Jindal is (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352.
S&F anodized aluminium powder coated of any colour (thickness of powder coating not less than 50 micron), in frame for doors, with one or more rebates including joining cleat for fixing etc ,complete all as specified. (Jindal Section No 20048=0.942 Kg/M)
S&F anodized aluminium powder coated door shutters, aluminium section weighing not less than 0.55 Kg/M including necessary joining cleats, glazing clips, rubber neoprene pakcing, Handles 2Nos in each shutter, hinges, anodised aluminium snap beading screw etc complete all as specified.
M&L door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed
M&L for Locks, drawer,grade I, size 75 mm 4 Lever in brass fixed to Aluminium door with duplicate keys
M&L for aluminium anodised barrel tower bolt of extruded section and fixed 200mm Long
S & F MS framed work such as grills gratings etc. with ends of bars shouldeed and / or riveted, or forged into spikes; framed guard bars and similar works conforming to Fe 290 Gde - E- 165 including welding etc complete all as spd
Complete removal of entire existing water proofing treatment in any position including tarfelt plaster, lean concrete , gravels etc and removing the debirs out side MD land all as pecified and directed.
M&L for 15 mm thick rendering in CM 1:4 over concrete surfaces (Roof) mixed with water proofing compound @ 3% by weight of cement complete all as specified. Note:- Water Proofing compound shall be measured and paid for seprately as "Supply Only"
Supply only WPC conforming to IS 2645.
M&L for APP based polymeric membrane minimum weighing 3.50 Kg/Sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 160 gms/Sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.30 Ltr/ Sqm by forced all as specified and as directed. (i) applying one coat of bituminous primer conforming to [email protected] per Sqm (ii) laying of APP based membrane as specified thickness and weight (iii) applying two coats of aluminium paint @ 100 ml/Sqm.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confrming to IS 1161-1979 grade St-240
M&L applying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate primer including preparation of new steel or iron surfaces exc 10 cm width or girth, complete all as specified and directed.
S&F fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed withL-type or J-type or cranked hook bolts and washer in roof,wall etc.complete all as specified and directed.
M&L precast cement concrete block masonry with solid block, type C-1,1:3:6 mix (using 20mm graded aggregate ), exc 10cm in width and setting in cement mortar 1:6, complete all as specified and directed.
M & L Hardcore of gauge n.exc 63mm broken stone or boulders deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface of broken stone or boulders complete all as specified and directed.
M & L 75 mm thick PCC (1:4:8) type D2 for sub base of floor.
M & L 75 mm thick PCC 1:2:4 type B 2 using 20 mm graded stone aggregate as in floor complete all as spd.
M&L PCC 1:2:4 type B0 in copings,kneelrs.bed plats kerbs, water troughs and like including weathering slightly rounded or champhered in edges including all necessary form work complete all as specified and directed.
M&L for continous brick edging , with width equal to depth of the brick, laid dry on end vertically complete all as specified.
M & L for machine made Rubber moulded precast conctete interlocking paver block (coloured), Glossy finish pre polished of any shape and size with white cement and pigment confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete all as spfd and directed.
M&L for spreading and levelling sand cushioning below paving block
Dismantling rails of any size and any type, and refixing the same in concrete work (RMC design mix M-40 grade in the item ser No.42 ), including taking outembedded portion and making good disturbed ground, and bent to shape, welded work all necessary drilling ,boltion or riveting etc and similar work, complete all as spfd and directed.
S & F 12 mm thick MS chequred plate with ruded, bolted or welded attachment.
M&L for demolition cement concrete in ground floor and pavings n.exe 15 cm thickness (below or above ground level)
M & L for RMC Design mix M-40 grade for Cement concrete work in pavement/hard-standing of flexural strength 40 kg/per squre centimetre in field using 400 kg of cement per cubic metre, thickness of concre 25 cm or less Note :(i) Design mix concrete shall be designed as specified and contractor shall quote his rates considering the cement contents as specified. (ii) Use and waste of side form for laying pavement concrete/hard-standing in bays between joints & contraction expansion joint/or between the two contraction joints for thickness of pavement upto and including 25 cm.
M & L for finishing surface of concrete roads, pavements, by brooming
M & L for forming construction joint 30 mm deep X 10 mm wide filled with sealing compound, Grade 'A'
M & L for forming contraction (Dummy) joint 65 mm deep x 10 mm wide filled with sealing compound, Grade 'A'
M & L for 12 mm thick expansion joint filled with pre-formed bituminus filler and top 30 mm primed and sealed with sealing compound Grade 'B'.
Taking down chowkats or frame exc 1.5 Sqm and n exc 4 sqm with shutters (without taking of shutter from the frame).
Forming jambs etc to opening including cutting toothing and properly bonding into old work including facing and pointing (if necessary) to match existing work complete in CM 1:4
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubish off the premises.
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off all as specified and directed.
M&L Providing precast cement concrete solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) setting in mortar 1:4 type C1 1:3:6 complete, in walls
Rendering 10 mm thick of fair faces of brickwork or concrete work in CM 1:4. finished even and smooth without using extra cement.
M&L for two coats of oil bound distpemper over a coat of primer over a coat of putty on New surfaces of wall
S&F anodized aluminium powder coated of any colour (thickness of powder coating not less than 50 micron), in frame for doors , windows, ventilators, partition wall etc. with one or more rebates, shutters, grills including joining cleat glazing clips for fixing etc. complete all as specified.
M&L for Powder coated aluminium door, window and ventilator shutters, fixed type/sliding type without sash bar, aluminium section wighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, Handle, lock, powder coated aluminium snap beading scres etc complete
S&F 12mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to Aluminium frame work with 6mm thick teak wood beading/edging alound.
M&L for Sheet glass, ordinary quality, in squares exc 0.5 sq. m each pane 5.5mm Thk in doors
M&Lfor double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass other parts made of mild steel heavy duty and fixed
M&L Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed
M&L for Locks, drawer,grade I, size 75 mm 4 Lever in brass fixed to Aluminium door with duplicate keys
S&F 4mm Thick Veneered decorative Plywood, grade 1 (with BWR Resin) with decorative face veeners on both faces, fixed with screws to timber/aluminium shutter framework.
M&L for complete removal of existing paint and applying two coats of oil bound distpemper over a coat of primer over 3mm thick coat of putty on old surfaces of wall
M&L for two coats of oil bound distpemper over a coat of primer over 3mm thick coat of putty on old surfaces of Ceiling
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed.
Taking down chowkats or frame Not exc 1.5 Sqm with shutters (without taking of shutter from the frame).
M&L for PCC 1:4:8 type D2 as in Sub base 75mm Thk
M&L for granite(of any type) work(table rubbed and polished) window cill and like set in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to matach with shade of granite thickness of granite 18 to 20mm
Rounding to edges of stone slabs one edge, such at in steps, window cill and other similar situation
M&L coloured /light shade vetrified ceramic tiles 10mm thick (square/regtangular) polished , area of each tiles not exc 0.36 sqm in floors etc and joineted neat in cement slurry and pointed in white or colour cement to match over 15mm thick screed bed in CM 1:6 .
M&L coloured /light shade vetrified ceramic tiles 10mm thick (square/regtangular) polished , area of each tiles not exc 0.36 sqm in floors etc and joineted neat in cement slurry and pointed in white or colour cement to match over 10mm thick backing coat in CM 1:4
S&F of mineral fibre acoustic suspended ceiling system with prima fine fissured (K2C2) tile with semi concealed grid , the tile should have humidity resistance (RH) of 99% , NRC upto 0.6, light reflectance> 83%, thermal conductivity K= 0.052 to 0.057 w/m, colour white fire performance class O/class 1 (BS476 part6 &7) in module sizeof 600x 600x16 mm with Bio block coating on the face of the tile, impact resistant and suitable for green bldg application, eith recycled contentof 63 %. The tile shall be laid on semi concealed grid system with 15 mm white flange incorporating 6 mm central reveal in white/black colour and with web height of 38 mm and load carring capacity of minimum 11.68 kg/sqm.Silhouette. main runner and cross tees to have mitred ends & birdmouth notches to provide mitred cruciform junction. The T sections have galvanising of 120 gms/sqm and passed through 500 hrs of salt test. the tile and grid system used together should carry a 15 year warrantee ( Make : armstrong, saint Gobain)
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed
S & F Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides 35mm Thk
S&F Decorative Laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive to Plywood as per manufacturers instruction.0.9mm Thick
M&L French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on but one or more coats on old work
S&F aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section etc length of bolt 250 mm.
S&F aluminium anodised barrel tower bolts of extruded section 200 mm long.
S&F butt hinges 100mm size stainless steel medium weight all as specified.
S&F aluminium handles, anodised, cast type, of size 150 mm
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed.
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off all as specified and directed.
M&L precast cement concrete block masonry with solid block, type C-1,1:3:6 mix ( using 20mm graded aggregate ), exc 10cm in width and setting in cement mortar 1:6, complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises all as spd and directed
M&L for granite(of any type) work(table rubbed and polished) cooking platform and like set in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to matach with shade of granite thickness of granite 18 to 20mm
M&L coloured /light shade vetrified ceramic tiles 10mm thick (square/regtangular) polished , area of each tiles not exc 0.36 sqm in floors etc and joineted neat in cement slurry and pointed in white or colour cement to match over 15mm thick screed bed in CM 1:6 .
All as per item No. above but on vertical surfaces such as dados, skirtings and risers to steps, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick rendering in CM 1:4 on stone masonry surfaces.
M&L for Rendring 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 on walls ,finishing surfaces even and smooth w/o using extra cement. Note : 1. mixed with water proofing compound @ 3% by weight of cement complete all as specified. 2. Water Proofing compound shall be measured and paid for seprately as "Supply Only"
M&L rendering 5 mm thick in CM (1:3) on concrete surface in ceilling finished even & smooth w/o using extra cement.
M&L for rendering 15mm thick on stone masonry surfaces or surfaces other than fair face of brick work in CM 1:6, finishing surfaces even and smooth without using extra cement complete all as specified.
M& L complete removal of existing surfaces on walls ,ceiling , fins , fascias etc , and applying two coats of weather proof exterior paint (Apex Ultima ) white or tinted ,over a coat of primer including necessary scaffolding all as specified and directed.
M&L for preparing of new surfaces wall applying two coats of OBD, white or tinted, over 3mm thick wall care putty all as directed .
M&L for complete removal of new plastered or unplastered ceiling surfaces and applying one coat of white wash as specified and directed by Engr -in-Charge.
M&L applying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate primer including preparation of new steel or iron surfaces exc 10 cm width or girth, complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-2 (40mm graded stone aggregate) finished even and smooth, without using extra cement as in plinth protection and path etc complete all as specified and directed.
S&F of mineral fibre acoustic suspended ceiling system with prima fine fissured (K2C2) tile with semi concealed grid , the tile should have humidity resistance (RH) of 99% , NRC upto 0.6, light reflectance> 83%, thermal conductivity K= 0.052 to 0.057 w/m, colour white fire performance class O/class 1 (BS476 part6 &7) in module sizeof 600x 600x16 mm with Bio block coating on the face of the tile, impact resistant and suitable for green bldg application, eith recycled contentof 63 %. The tile shall be laid on semi concealed grid system with 15 mm white flange incorporating 6 mm central reveal in white/black colour and with web height of 38 mm and load carring capacity of minimum 11.68 kg/sqm.Silhouette. main runner and cross tees to have mitred ends & birdmouth notches to provide mitred cruciform junction. The T sections have galvanising of 120 gms/sqm and passed through 500 hrs of salt test. the tile and grid system used together should carry a 15 year warrantee ( Make : armstrong, saint Gobain)
Taking down or chaukhat or frames exc 1.50 sqm but n exc 4.0 sqm without taking of shutter from frames complete
Taking down chowkats or frame with shuters (without taking off shutters from the frames) not exc 1.5 Sqm each and removing to stores
M&L forming jambs, Cills etc. in cement mortat 1:6, to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work complete all as specified and directed.
S&F three track sliding window with 4mm thick tinted glass in two shutter and one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing including good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed by Engr-in-Charge. Series of aluminium section as per Jindal is (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352.
S&F anodized aluminium powder coated of any colour (thickness of powder coating not less than 50 micron), in frame for doors, with one or more rebates including joining cleat for fixing etc ,complete all as specified. (Jindal Section No 20048=0.942 Kg/M)
S&F anodized aluminium powder coated door shutters, aluminium section weighing not less than 0.55 Kg/M including necessary joining cleats, glazing clips, rubber neoprene pakcing, Handles 2Nos in each shutter, hinges, anodised aluminium snap beading screw etc complete all as specified.
M&L Door Aluminium (extruded section body) closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed
M&L for Locks, drawer,grade I, size 75 mm 4 Lever in brass fixed to Aluminium door with duplicate keys
M&L for aluminium anodised barrel tower bolt of extruded section and fixed 200mm Long
S & F MS framed work such as grills gratings etc. with ends of bars shouldeed and / or riveted, or forged into spikes; framed guard bars and similar works conforming to Fe 290 Gde - E- 165 including welding etc complete all as spd
Complete removal of entire existing water proofing treatment in any position including tarfelt plaster, lean concrete , gravels etc and removing the debirs out side MD land all as pecified and directed.
M&L for 15 mm thick rendering in CM 1:4 over concrete surfaces (Roof) mixed with water proofing compound @ 3% by weight of cement complete all as specified. Note: Water Proofing compound shall be measured and paid for seprately as "Supply Only"
Supply only WPC conforming to IS 2645.
M&L for APP based polymeric membrane minimum weighing 3.50 Kg/Sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 160 gms/Sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.30 Ltr/ Sqm by forced all as specified and as directed. (i) applying one coat of bituminous primer conforming to [email protected] per Sqm (ii) laying of APP based membrane as specified thickness and weight (iii) applying two coats of aluminium paint @ 100 ml/Sqm.
M&L steel rolling shutter with laths of thickness 1.00 mm without ball bearing as specified including top cover anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, complete, push pull or manual type complete as in repair including taking down rolling shutter, confirming to the requirement of IS 6248-1979 all as specified & directed.
S&F Venition blends with design on inner/outer face roll down type made out of fibre cloth fixed, to wall with necessary Aluminium brackets, screws etc including Alluminium frame for venilion blinds etc all as approved by GE all as specified and directed. Make : Vista and Levador or Equivalent
S&F 12 mm thick, prelaminated both side cement bonded particle board are to be of wood finish dark teak shade and conforing to IS-14276-1995, (Bison panels by NCL group, member indian green building council). The composition of the boards comprises of approximaterly 60% Cement 30% plantation wood (remaining being other chemical/water binders etc) with a density of approximaterly 1250-1300 kg/m3, fixed with screws to timber frame work Aluminium frame work for doors, partitions, cabinets, cupboards, wall paneling , cladding etc including screws and all screw finish with lambi etc as per specifications. Note :- All Bison panels are fixing by self thrieded machine screw, 25/38 mm as per requirement. This system used together should carry a 10 years warrantee.
Excavating in post holes ( or similar hoels ) each n exc 0.5 cum getting out, returining, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm , watering, and removing surplus soil to a distance n exc 50 mtr.
M&L cement concrete in foundation type C 2, 1:3:6 ( 40 mm gde stone aggregate) as in filling and mass concrete.
Rolled mild steel in plates, channels square cut or notched (ordinary and colour sunk) forming holes, without any attachment conf to Fe 410-W (Gde E-250) quality 'A'.
S&F rolled mild steel in joist, channels, angles or tee sections, fixed ,post independently without connecting plates, etc.,conf to Fe 410-W (Gde-E-250) quality 'B'.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confrming to IS 1161-1979 grade St-240
M&L applying two coats of synthetic enamel paint over a coat of red oxide 0r zinc chromate primer including preparation of new steel or iron surfaces exc 10 cm width or girth, complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof couring /cladding to wall fixed with self tapping screws complete all as specified and directed..
Surface dressing not exc 15 cm deep and getting out in soft/ loose soil complete all as specified.
M&L PCC in kerb Stone precast (factory made) any shape and size or as directed by engr in charge including weathering, slightly rounded or chamfered angles and throating, in type B-1 1:2:4 (20mm graded agg) set in cement mortar 1:4, complete all as spfd and directed.
Hardcore(Broken boulder) of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M & L 75 mm thick PCC (1:4:8) type D2, using 40 mm graded stone aggregate as in sub base surfice finished even and fough to receive floor topping complete all as specified.
M & L for machine made Rubber moulded precast conctete interlocking paver block (coloured), Glossy finish pre polished of any shape and size with white cement and pigment confirming to IS 15658-2006 of 60 mm thickness M-35 Grade and over and including 25mm average thickness sand cushioning complete all as spfd and directed.
Excavation in post hole (or similar holes) each n.exc 0.5 cum and getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm watering and removing surplus soil to a distance n.exc 50m and making good in hard/dense soil
M & L for PCC 1:3:6 type C-2 in foundation filling and mass concrete all as specified.
M & L 50x50x6mm angle iron as in fencing post, incl cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets ( for securing wire mess) incl all necessary drilling , bolting or reveting etc
M & L 40x6mm Flat iron as in ties , incl cutting tops to shape as directed, drilling holes, notching for wire etc,
M & L for mild steel round bars 8 mm dia and over cut to length bent to shape required and fixing as required in fencing.
Supply only chain link MS galavanised fencing as specified
Fixing only chain link fencing including line wires, and mesh size type of stadrads, rail straining bols etc size of mess 50x50x 3mm dia wire
S & F MS bolts machine made with hexagonal or square head one end and screwed the other or screwed both end n.ext 5 cm long 12mm dia
M &L Two coat of synthetic enamel paint to steel surface over a coat of rex oxid primer n exc 10 cm width or girth incl preparation of new surfaces
M &L Two coat of synthetic enamel paint to steel surface over a coat of rex oxid primer exc 10 cm width or girth incl preparation of new surfaces
Excavating in post holes ( or similar hoels ) each n exc 0.5 cum getting out, returining, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm , watering, and removing surplus soil to a distance n exc 50 mtr.
M&L cement concrete in foundation type C 2, 1:3:6 ( 40 mm gde stone aggregate) as in filling and mass concrete.
Rolled mild steel in plates, channels square cut or notched (ordinary and colour sunk) forming holes, without any attachment conf to Fe 410-W (Gde E-250) quality 'A'.
S&F rolled mild steel in joist, channels, angles or tee sections, fixed ,post independently without connecting plates, etc.,conf to Fe 410-W (Gde-E-250) quality 'B'.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confrming to IS 1161-1979 grade St-240
M&L applying two coats of synthetic enamel paint over a coat of red oxide 0r zinc chromate primer including preparation of new steel or iron surfaces exc 10 cm width or girth, complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof couring /cladding to wall fixed with self tapping screws complete all as specified and directed..
M&L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through PVC concealed conduit fixed to walls / roofs / floors / ceiling etc and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly, including Suitable size of modular cover plates and modular flush boxes, Plate for mounting for housing the switches, socket outlets, fan regulators etc, all as specified and as directed. (a) One light point controlled by one way switch.
(b) One Fan/Exhaust fan point controlled by one switch and one regulator.
(c) One 3 pin switch socket outlet point 5 Amps on independent board.
(d) One 3 pin switch socket outlet point 5 Amps on same board with other switch.
All as per item above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size.
S & Fix modular switch1 way 6A, 1 module
S & Fix modular switch1 way 16A, 1 module
S & Fix Modular socket out let 6A 2/3 on combined 2 module.
S & Fix Modular socket out let 6A/16A-2/3 pin combined 2 module.
S & Fix Ceiling rose surface backlite 65x50mm 3 terminals complete.
S & Fix Fan regulator electronic 2 modular type volts AC 50 HZ ,100 Watts, 4 step complete all as directed.
S & Fix LED Batten for LED tube light channel 18 watts fitting with necessary braket, clamps, incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. Make - Bajaj Cat Part No - BLRB-DB 118 / Havells Cat Part No - REGALBATTENT8UPTO1X22WSSBSWH / Crompton Cat Part No - IGP131LT8-16 or other.
S & Fix LED tube light Rode 18 watts with necessary fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. Make - Bajaj Cat Part No - BLRB-DB 18CW LED / Havells Cat Part No - PHOTONULTRA + 1213T8SSTL18WLED865SPC / Crompton Cat Part No - LT8-20-865-2 or other.
S & Fix LED 10 W Batten integrated LED chanel fitting integral sleek extruded polycarbonate LED chanel with acrylic cover,Neutral/cool white with all accessories all as specified and directed by Engr-in-charge Make - Bajaj Cat Part No - BCLSB 10 WH / Havells Cat Part No - LUMILINEPLUSBS10WLED865SPCSS / Jaquar Cat Part No - LGLZO1X010XW or other.
S & Fix Fans ceiling complete with electronic type regulater and accessories 230 volts,1200 mm sweep complete all as specified & directed. Make- Bajaj/Havells/USHA
S & Fix Heavy duty Exhaust fan AC single phase 230 volt 900 RPM of size 300 mm sweep with louver and fixing arrangement by making hole of wall /floor and making the distrubed surface complete all as specified & directed. Make : Havells Cat part no - Turbo jet SP / Bajaj - Max Air / Usha.
S & Fix sheet metal enclosure distribution board SPN, 8 ways 240 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs all as specified and as directed.
S & Fix of MCB single pole and neutral, 240 volts, 5 to 63 Ampere, rupturing capacity 10 KA, ‘B’ series complete all as specified and directed.
S & Fix of MCB single pole, 240 volts, 5 to 32 Ampere, rupturing capacity 10 KA, ‘B’ series complete all as specified and directed.
S & Fix LED street light 30 W CUB type building security light pressure die cast aluminium housing LED street light lumaniries with IP 65 and complete all accessories and fixing arrengenment all as specified and directed by Engr-in-charge. Make - Bajaj Cat Part No - BCLST30W LED I / Havells Cat Part No -ENDURACITYLITEPLATPLUSSL30WLED757SASYBOPC / Crompton Cat Part No - LTRUMP0030XW or other.
M & L for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable , multistranded on the surface through and including suitable size of PVC Conduit in fixed to walls / roofs / floors / ceiling etc with its accessories all as specified and directed by Engr-in -charge for the following. (a) 2x1.5 sq mm and 1x1.5 sq mm as earth wire.
S & Fix of bracket / arm for street light fiting made out of 40 mm dia GI pipe not exceeding 1.2 mtr long complete accessories including fixing of MS clamps 2 Nos nut and bolts complete.
M & L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the plate not less that 1.5M below normal grouond level connected to GI earth wire 4 mm dia by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 03 of SSR Part-I connected to earthing test point / DB including excavation / earth work in any type of strata, removal of surplus earth, GI pipe for watering pipe with and funnel, PCC 1:3:6 Type C-1 chamber with 40 mm thick RCC 1:2:4 type B-1 in cover slab with TMT bars @ 150 mm c/c both way with GI protection pipe complete all as specified and directed by Engineer-in-Charge.
Supply and Laying and testing cable XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm, 4 core cable connecting lugs, glands,jointing materials etc, laid on wall, floors, roof, ducts and fixing using clamps, saddle complete all as directed by Eng-in-charge of following.
Supply and Laying and testing cable XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm, 2 core cable connecting lugs, glands,jointing materials etc, laid on wall, floors, roof, ducts and fixing using clamps, saddle complete all as directed by Eng-in-charge of following.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in Hard / dense or any type of soil including forming bottom surface etc.
Returning, filling in including spreading, levelling ,watering and well ramming in layers not exceeding 25 cm thick complete.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 50 mtr above the starting point.
Supply & Laying 50 mm outside dia double wall corrugated pipe (DWC) ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement.
Material and labour for cutting of bituminous road / floor for laying of pipe / cables not exceeding 30 cm wide and not exceeding 60 cm deep including refilling / with material and, watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete and all area to clean all as specified and directed by Engr-in-Charge.
M &L for GI pipe ''light grade'' for road crossing / on wall / on pole for cable protection of following size:- Make: TATA/JINDAL/ PRAKASH SURYA a) 50 mm dia
Supply, install, commissioning and testing Cubical outdoor type factory made double door, powder coated LT Bus bar feeder pillar box for 200 amps 3 Phase and neutral arrangement of size 500mm x 500mm x 200 mm to accommodate the following :- (i) Aluminium bus bar 3 phase 4 wire-200 Amps -01 set (ii) MCCB TPN 63 amps-01 nos (iii) MCB TP 32 amps-01 nos (iv) MCB SP 32 amps-02 nos and weather proof and vermin proof conforming to IP - 54 made out of 3.2 mm thick CRCA sheet including provision for ventilation and cable termination alley all as per IS. It should be mounted on 40 x40 x6 mm angle frame with a clearance of at least o.45 mtrs above GL na 0.30 mtrs below ground including PCC for foundation and coping.
Taking down copper / Aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Taking down sub main wiring complete including fitting and fixtures and removing materials. making good the disturbed surfaces of walls, floors, roof etc, all as specified and as dirfected.
Taking down DBs With MCBs / Isolator any size and capacity all as specified and as dirfected.
M&L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through PVC concealed conduit fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly, including modular cover plates and modular flush boxes, Plate for mounting for housing the switches, socket outlets, fan regulators etc, all as specified and as directed. (a) One light point controlled by one switch.
(b) One fan point controlled by one switch.
(c) One 3 pin switch socket outlet point 5 Amps on independent board.
(d) One 3 pin switch socket outlet point 5 Amps on same board with other switch.
All as per item above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size.
S & Fix modular switch1 way 6A, 1 module
S & Fix modular switch1 way 16A, 1 module
S & Fix Modular socket out let 6A 2/3 on combined 2 module.
S & Fix Modular socket out let 6A/16A-2/3 pin combined 2 module.
S & F Fan regulator electronic 2 modular type volts AC 50 HZ ,100 Watts, 4 step complete all as directed.
S & F LED 36 watt reccessed mounting 2 x 2 luminaire white powder coated CRCA housing with high powder LEDs .Aluminium front frame with flat white high transmission acrylic cover with complete accessories all as specified and directed by engr-in charge. MAKE- BAJAJ CAT NO - BZRSQL 36W GZi NW / wipro cat part - CRCO10R038HP57GL1 or other.
S & F LAN socket connector RJ 45 with socket with copper feed modular type all as directed by Eng-in-Charge.
Taking down the defective ceiling fan of any sweep and make after disconnecting electrically & mechanically and examine & carry out the servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of painting re-fixing and testing and ceiling fan rode to the extended of length in all respect for smooth running complete.
M & L for submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable , multistranded and including suitable size of PVC conduit and all accessories concealed in walls / roofs / ceiling etc. earth dolly, terminated in terminal box including cutting chases and making good to disturbed surface complete all accessories all as specified and directed by Engr-in -charge for the following. Note :- (i) Two runs of copper conductor and one run of earth copper conductor shall be measured as one length. (a) 2 x 6 sq mm and 1 x 6 sq mm as earth wire
S & Fix sheet metal enclosure distribution board SPN, 8 ways 240 volts, with 200 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs all as specified and as directed Make-legrand/C&S/Standard/Schneider
S & Fix of MCB single pole and neutral, 240 volts, 32 to 40 Ampere, rupturing capacity 10 KA, ‘B’ series complete all as specified and directed.
S & Fix of MCB single pole, 240 volts, 5 to 32 Ampere, rupturing capacity 10 KA, ‘B’ series complete all as specified and directed.
Taking down carefully aluminium / copper point wiring complete (light, fan socket & power) including unserviceable fixtures and fittings such as switches ceilimg roses pendents regulators sockets light fittings etc complete removing material to store for keeping in safe custody for taking credit & making good disturbed wall / floor etc complete all as directed by Engineer-in-Charge
M&L Point wiring complete with 1.5 sqmm single core PVC insulated and unsheathed cable 1100 volts, FRLS grade with multistranded copper conductor ISI marked drawn through PVC concealed conduit fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm stranded copper conductor cable as earth continuity conductor and connected to common earth dolly, including modular cover plates and modular flush boxes, Plate for mounting for housing the switches, socket outlets, fan regulators etc, all as specified and as directed. (a) One light point/ fan point/ bell point controlled by one way switch
(b) One socket point 6 Amps on same board
(c) One socket point 6 Amps on independent board
All as per item Sl No 194.00 above but with 2.5 sq mm PVC insulated cable and 2.5 sq mm as earth wire for 16 amps socket outlet on independent board
S&F modular switch single pole,one way 6 Amps capacity
S&F modular switch single pole,one way 16 Amps capacity
S&F modular socket, outlet 2 in 1, 6 Amp capacity
S&F modular socket, 6A/16A 2 in1, 16 Amp capacity
S&F fan Regulator step down 120 Watt
S&F of ceiling rose, surface bakelite, 65 X 50 mm, 3 terminals complete all as specified and directed.
M & L for taking out Split type air conditioner indoor and outdoor unit complete with copper tubing of any size and make for shifting at other place after making necessary opening size, cutting of wall any type/ thickness and fixing of AC after necessary servicing, GAS Charging making suitable arrangement for fixing of AC complete all as specified and directed.
Supply and fixing Single pole and neutral enclouser with two pin and earthplug and socket complete with one single pole MCB with 240 V 20 AMPs.
Supply only capillary tube special annealed double wound copper tubing suitable for 1.5/1.8/2 ton window type air conditioner of diameter 0.25 " bore as per existing complete all as specified and directed.
Supply only capillary tube special annealed double wound copper tubing suitable for 1.5/1.8/2 ton window type air conditioner of diameter 0.38" bore complete all as specified and directed.
S&F LED/CFL Bulk Light fitting, 10 watt, 230 volts, complete with all accessories pre-wired,ceiling cutting and including connecting up with twin core twisted flexible copper conductor cable with suitable size. all as specified & directed. Make:- Bajaj/Wipro/Fortune ARRT/ Havells.
M&L for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable , multistranded on the surface through and including suitable size of PVC casing and capping with its accessories all as specified and directed by Engr-in -charge for the following (a) 2x2.5 sq mm and 1x2.5sq mm as earth wire
(b) 2x4.0 sq mm and 1x4 sq mm as earth wire
(c) 2x6.0 sq mm and 1x6 sq mm as earth wire
S & F for recess mounted 2' x 2' square LED panel 36 watts, 596 x 596 x 9 mm size, sleek design aluminium housing, polycarbibate diffuser white powder coated finish operating voltage 140 volts - 270 volts, AC, 50 Hz complete all as directed by Engineer- in-charge. Make- Bajaj Cat part No - BCTBLR 36W FP, Philips Cat Part No RC380 LED 34S PSU or its equivalent in Wipro.
S & F of sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 12 ways with 100 ampere rated bus bar, 240 volts fixed sunk/flush to the wall or niche complete all as specified and directed.Make:- Legrand/Indo Asian/C & S.
S& Fix sheet metal enclosure distribution board SPN, 2 ways 240 volts, with 200 amps need rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs all as specified and as directed Make-legrand/C&S/Standard/Schneider.
S & F of MCB single pole and neutral, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ series complete all as specified and directed.
S & F of MCB single pole, 240 volts, 5 to 32 Ampere, rupturing capacity 10 KA, ‘B’ series complete all as specified and directed.
S & F LED street light 30 W CUB type building security light pressure die cast aluminium housing LED street light lumaniries with IP 66 and complete accessories all as specified and directed by Engr-in-charge. Make: Bajaj Cat Part no.- BCLST30W LED I/ Havells Cat Part no.-ENDURACITYLITEPLATPLUSSL30WLED757SASYBOPC/ Crompton cat Part no- LTRUMP0030XW
Taking down carefully ceiling fan/ exhaust fan of any sweep, keeping with safe custody and refixing the same with replacement of unsv 3 core PVC insulated PVC sheated 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal over hauling the fan, replacement of fan condensor 2.5 Mfd and painted with synthatic enamel white colour paint by spray machine including filling of cavities with filler material complete all as specified and as directed.
S & F for ceiling fan down rods 1.0 M Long of 15 mm dia GI pipe to the existing trusses of any height including necessary welding & fixing with clamps and nut bolts etc complete all as specified and as directed.
S & F for plastic body exhaust fan, AC single phase, 240 V of size 200 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed. Make - Bajaj Cat Part No -Maxma DX 8" or its equivalent in Crompton/Havells.
S&F LAN cable 4 pairs PVC insulated and PVC sheathed all as directed by Engr in Charge
S&F LAN socket connecter RJ45 with socket with copper feed modular type all as directed by Eng in Chrage
M & L for earthing complete with deep galvanised earth plate 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 M deep bellow ground level with top edge of plate) not less than 1.5 m bellow normal ground level connected to galvanised earth led strip 25x 4 mm by means of galvanised iron or steel all as shown in electrical plate No 3 connected to earth test point all as specified or indicated including testing on completion . (Note -Rate are including of excavation,PCC Pit, PCC/CI cover, fune, watering pipe ,test point complete)
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality, Refrigerent R-410 with 5 star rating and with inverter technology of capacity 1.5 TR Make-voltas/carrier,
M & L Sub main wiring complete with 2 runs of 4 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn through PVC cassing and capping / PVC conduit accessories fixed on surface/wall / celing etc including provision of 1 run of 4.0 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity all as directed and specified by Engr-in-charge. Note : Two runs of copper conductor and 1 runs of earth copper conductor shall be measured as one length.
Supply and fixing Single pole and neutral enclouser with two pin and earthplug and socket complete with one single pole MCB with 240 V 20 AMPs.
Supply and fix suction and discharge copper tubing pipe 3/8" and 5/8" for split type AC including provision of insulation on tubing, PVC insulated flexible multistranded copper cable 3 core 4 sqmm all as directed by Engr-in-charge.
Supply and fix voltage stabiliser for automatic operation , single phase naturaly air cooled indoor type and designed for input variation between 170 to 270 volts with out put voltage stabilized at 230 volts with accuracy +/- 2.5% and of capacity 4KVA incl dismentling make-M Guard/V Guard.
Cutting holes by core cutting machine or other mean into or through cement concrete slabs, chajjas, reinforced or otherwise, brick / stone masnary walls etc. cutting area n. exe. 100 sqcm and making good disturbed surfaces
J.G.Goel
M/S P D TUPE
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .