| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹42.0 L+₹8.2 L (24.3%)Rejected-AOC NO 12 5TH B CROSS SHARADAMBA NAGAR M E S ROAD BANGALORE 560013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹48.9 L+₹15.1 L (44.8%)Rejected-AOC | L3 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | Shanthi Construction L2 | RRK PROJECTS L1 | RAMSON TRADERS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of Indoor Automatic Power factor capacitor bank Panel CPRI approved of capacity 275 KVAR system of 'Ready to use' suitable for 440 Volt, 3 Phase, 50 Hz, AC and housed in an enclosure elegant, fabricated from 2 mm thick CRCA sheet with anti-corrosive coating and finally powder coated in texture, duly controlled by auto & manual complete all as specified connecting with the existing system with incoming and outgoing cables with duly lugged terminals all as specified & directed incl comprising of the following:-
(Make-Neptune Ducati / L&T / C&S / Siemens / ABB / GEC) | 1 | Each Set | 7,50,000 ₹7,50,000 | 4,65,000 ₹4,65,000 Lowest | 8,90,000 ₹8,90,000 |
| 1.10 | (a) A set of mixed dielectric low loss heavy duty capacitor in 7 steps (3x50 KVAR + 2x25 KVAR + 2x15 KVAR + 2 x 10 KVAR + 2x5 KVAR + 3x3 KVAR + 3x3 KVAR) type MPP-H by using metalised polyproplene technology having total losses less than 0.45W/KVAR, 250% high overload current and frequent switching operation upto 10000/year, Non linear load upto 25%.
(b) MCCB 630 amps, TP, 36 KA, 415 Volts as main incomer of APFC panel, duly connected using lugs complete. MCCB should be adjustable for O/L setting from 70 to 100% for thermal magnetic trip unit. Protection setting shall aply to all poles of MCCB through single knob from the front of MCCB without opening the front cover, Back up protection MCB upto 25 KVAr, MCCB 100 amps for 50 KVAr, control based switching system.
(c) Microprocessor based automatic power factor controller relay of required no. of stages to control the reactive power required to obtain the target power factor with its unique feature of four quadrant operation, with its automatic recognition or with standard programme, easy setting of power factor & automatic C/K ratio selection, able to check each & individual capacitor bank connected. The APFC controller should on/off the capacitor banks with indication of No. of Banks selected, PF status/indication whether it is lagging/leading/unity. | - | - | - | - | - |
| 1.20 | (d) Suitable rating of capacitor duty contactors for each step shall be used and shall be provided with special inrush current limiting coils to limit the capacitor inrush current.
(e) Internal wiring with minimum 1.5 sqmm size of PVC flexible copper conductor wire using lugs.
(f) Cooling fan should be provided upside and louvers should be kept down side to enter the air from lower side and hot air comes outside from upwards. Cooling fan should be operated through thermostat so that when the temperature reaches on higher side, fan should start automatically.
(g) Amp meter, digital type of suitable size/rating
(h) Volt meter, digital type of suitable size/rating
(j) 3 Nos. CTs of suitable rating, accuracy class 1, Burden 15 VA
(k) Indication lamp
(l) Required Civil/PCC work 1:3:6 type C2 using 40mm graded aggregate foundation for fixing of APFC panel complete as directed | - | - | - | - | - |
| 2.00 | All as per item No 1.00 here-in-before but outdoor type of capacity 275 KVAR | 1 | Each Set | 7,60,000 ₹7,60,000 | 4,90,000 ₹4,90,000 Lowest | 8,90,000 ₹8,90,000 |
| 3.00 | Supply, installation, testing and commissioning of Indoor Automatic Power factor capacitor bank Panel CPRI approved of capacity 175 KVAR system of 'Ready to use' suitable for 440 Volt, 3 Phase, 50 Hz, AC and housed in an enclosure elegant, fabricated from 2 mm thick CRCA sheet with anti-corrosive coating and finally powder coated in texture, duly controlled by auto & manual complete all as specified connecting with the existing system with incoming and outgoing cables with duly lugged terminals all as specified & directed incl comprising of the following:-
(Make-Neptune Ducati / L&T / C&S / Siemens / ABB / GEC) | 1 | Each Set | 4,95,000 ₹4,95,000 | 3,60,000 ₹3,60,000 Lowest | 5,80,000 ₹5,80,000 |
| 3.10 | (a) A set of mixed dielectric low loss heavy duty capacitor in 7 steps (2x50 KVAR + 1x25 KVAR + 1x15 KVAR + 1x10 KVAR + 3x5 KVAR + 2x3 KVAR + 2x2 KVAR) type MPP-H by using metalised polyproplene technology having total losses less than 0.45W/KVAR, 250% high overload current and frequent switching operation upto 10000/year, Non linear load upto 25%.
(b) MCCB 400 amps, TP, 36 KA, 415 Volts as main incomer of APFC panel, duly connected using lugs complete. MCCB should be adjustable for O/L setting from 70 to 100% for thermal magnetic trip unit. Protection setting shall aply to all poles of MCCB through single knob from the front of MCCB without opening the front cover, Back up protection MCB upto 25 KVAr, MCCB 100 amps for 50 KVAr, control based switching system.
(c) Microprocessor based automatic power factor controller relay of required no. of stages to control the reactive power required to obtain the target power factor with its unique feature of four quadrant operation, with its automatic recognition or with standard programme, easy setting of power factor & automatic C/K ratio selection, able to check each & individual capacitor bank connected. The APFC controller should on/off the capacitor banks with indication of No. of Banks selected, PF status/indication whether it is lagging/leading/unity. | - | - | - | - | - |
| 3.20 | (d) Suitable rating of capacitor duty contactors for each step shall be used and shall be provided with special inrush current limiting coils to limit the capacitor inrush current.
(e) Internal wiring with minimum 1.5 sqmm size of PVC flexible copper conductor wire using lugs.
(f) Cooling fan should be provided upside and louvers should be kept down side to enter the air from lower side and hot air comes outside from upwards. Cooling fan should be operated through thermostat so that when the temperature reaches on higher side, fan should start automatically.
(g) Amp meter, digital type of suitable size/rating
(h) Volt meter, digital type of suitable size/rating
(j) 3 Nos. CTs of suitable rating, accuracy class 1, Burden 15 VA
(k) Indication lamp
(l) Required Civil/PCC work 1:3:6 type C2 using 40mm graded aggregate foundation for fixing of APFC panel complete as directed | - | - | - | - | - |
| 4.00 | All as per item No 3.00 here-in-before but outdoor type of capacity 175 KVAR | 1 | Each Set | 5,05,000 ₹5,05,000 | 3,70,000 ₹3,70,000 Lowest | 5,80,000 ₹5,80,000 |
| 5.00 | Supply, installation, testing and commissioning of Indoor Automatic Power factor capacitor bank Panel CPRI approved of capacity 90 KVAR system of 'Ready to use' suitable for 440 Volt, 3 Phase, 50 Hz, AC and housed in an enclosure elegant, fabricated from 2 mm thick CRCA sheet with anti-corrosive coating and finally powder coated in texture, duly controlled bu auto & manual complete all as specified connecting with the existing system with incoming and outgoing cables with duly lugged terminals all as specified & directed incl comprising of the following:-
(Make-Neptune Ducati / L&T / C&S / Siemens / ABB / GEC) | 1 | Each Set | 2,50,000 ₹2,50,000 Lowest | 2,58,000 ₹2,58,000 | 3,60,000 ₹3,60,000 |
| 5.10 | (a) A set of mixed dielectric low loss heavy duty capacitor in 6 steps (1x25 KVAR + 1x15 KVAR + 2x10 KVAR + 3x5 KVAR + 3x3 KVAR + 3x2 KVAR) type MPP-H by using metalised polyproplene technology having total losses less than 0.45W/KVAR, 250% high overload current and frequent switching operation upto 10000/year, Non linear load upto 25%.
(b) MCCB 200 amps, TP, 36 KA, 415 Volts as main incomer of APFC panel, duly connected using lugs complete. MCCB should be adjustable for O/L setting from 70 to 100% for thermal magnetic trip unit. Protection setting shall aply to all poles of MCCB through single knob from the front of MCCB without opening the front cover, Back up protection MCB upto suitable rating, control based switching system.
(c) Microprocessor based automatic power factor controller relay of required no. of stages to control the reactive power required to obtain the target power factor with its unique feature of four quadrant operation, with its automatic recognition or with standard programme, easy setting of power factor & automatic C/K ratio selection, able to check each & individual capacitor bank connected. The APFC controller shoulf on/off the capacitor banks with indication of No. of Banks selected, PF status/indication whether it is lagging/leading/unity. | - | - | - | - | - |
Tender Value
Refer Docs
EMD Value
₹89,982
Closing Date
5 Dec 2025, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE - 560006
SPECIAL REP/REPLACEMENT OF OLD VINTAGE APFC PANELS AND PROVN OF WINDOW/SPLIT AC IN VARIOUS WARDS AT CHAFB
2025_MES_739830_1
8421/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
Yes
GE (AF) BANGALORE
₹89,982
6 Jan 2026
14 Nov 2025
8 Dec 2025
14 Nov 2025
5 Dec 2025
28 Nov 2025
15 Nov 2025 - 22 Nov 2025
Amount
Supply, installation, testing and commissioning of Indoor Automatic Power factor capacitor bank Panel CPRI approved of capacity 275 KVAR system of 'Ready to use' suitable for 440 Volt, 3 Phase, 50 Hz, AC and housed in an enclosure elegant, fabricated from 2 mm thick CRCA sheet with anti-corrosive coating and finally powder coated in texture, duly controlled by auto & manual complete all as specified connecting with the existing system with incoming and outgoing cables with duly lugged terminals all as specified & directed incl comprising of the following:- (Make-Neptune Ducati / L&T / C&S / Siemens / ABB / GEC)
(d) Suitable rating of capacitor duty contactors for each step shall be used and shall be provided with special inrush current limiting coils to limit the capacitor inrush current. (e) Internal wiring with minimum 1.5 sqmm size of PVC flexible copper conductor wire using lugs. (f) Cooling fan should be provided upside and louvers should be kept down side to enter the air from lower side and hot air comes outside from upwards. Cooling fan should be operated through thermostat so that when the temperature reaches on higher side, fan should start automatically. (g) Amp meter, digital type of suitable size/rating (h) Volt meter, digital type of suitable size/rating (j) 3 Nos. CTs of suitable rating, accuracy class 1, Burden 15 VA (k) Indication lamp (l) Required Civil/PCC work 1:3:6 type C2 using 40mm graded aggregate foundation for fixing of APFC panel complete as directed
All as per item No 1.00 here-in-before but outdoor type of capacity 275 KVAR
Supply, installation, testing and commissioning of Indoor Automatic Power factor capacitor bank Panel CPRI approved of capacity 175 KVAR system of 'Ready to use' suitable for 440 Volt, 3 Phase, 50 Hz, AC and housed in an enclosure elegant, fabricated from 2 mm thick CRCA sheet with anti-corrosive coating and finally powder coated in texture, duly controlled by auto & manual complete all as specified connecting with the existing system with incoming and outgoing cables with duly lugged terminals all as specified & directed incl comprising of the following:- (Make-Neptune Ducati / L&T / C&S / Siemens / ABB / GEC)
(d) Suitable rating of capacitor duty contactors for each step shall be used and shall be provided with special inrush current limiting coils to limit the capacitor inrush current. (e) Internal wiring with minimum 1.5 sqmm size of PVC flexible copper conductor wire using lugs. (f) Cooling fan should be provided upside and louvers should be kept down side to enter the air from lower side and hot air comes outside from upwards. Cooling fan should be operated through thermostat so that when the temperature reaches on higher side, fan should start automatically. (g) Amp meter, digital type of suitable size/rating (h) Volt meter, digital type of suitable size/rating (j) 3 Nos. CTs of suitable rating, accuracy class 1, Burden 15 VA (k) Indication lamp (l) Required Civil/PCC work 1:3:6 type C2 using 40mm graded aggregate foundation for fixing of APFC panel complete as directed
All as per item No 3.00 here-in-before but outdoor type of capacity 175 KVAR
Supply, installation, testing and commissioning of Indoor Automatic Power factor capacitor bank Panel CPRI approved of capacity 90 KVAR system of 'Ready to use' suitable for 440 Volt, 3 Phase, 50 Hz, AC and housed in an enclosure elegant, fabricated from 2 mm thick CRCA sheet with anti-corrosive coating and finally powder coated in texture, duly controlled bu auto & manual complete all as specified connecting with the existing system with incoming and outgoing cables with duly lugged terminals all as specified & directed incl comprising of the following:- (Make-Neptune Ducati / L&T / C&S / Siemens / ABB / GEC)
(d) Suitable rating of capacitor duty contactors for each step shall be used and shall be provided with special inrush current limiting coils to limit the capacitor inrush current. (e) Internal wiring with minimum 1.5 sqmm size of PVC flexible copper conductor wire using lugs. (f) Cooling fan should be provided upside and louvers should be kept down side to enter the air from lower side and hot air comes outside from upwards. Cooling fan should be operated through thermostat so that when the temperature reaches on higher side, fan should start automatically. (g) Amp meter, digital type of suitable size/rating (h) Volt meter, digital type of suitable size/rating (j) 3 Nos. CTs of suitable rating, accuracy class 1, Burden 15 VA (k) Indication lamp (l) Required Civil/PCC work 1:3:6 type C2 using 40mm graded aggregate foundation for fixing of APFC panel complete as directed
Addition and alteration in the exisitng panel as required / directed including supply and fixing of MCCB TP 630 A 35 KA, 415 Volt, adjustable thermal & adjustable magnetic incl connection complete all as specified and as directed
All as per Item No 6.00 as here-in-before but MCCB TP 400 A, 35 KA.
All as per Item No 6.00 as here-in-before but MCCB TP 200 A 35 KA.
Supply and laying cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elect power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of following sizes:- (Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately)
240 sqmm 3.5 core.
300 sqmm 3.5 core.
120 sqmm 3.5 core.
Excavation in trenches not exc 1.5 m wide and n.exc 1.5 m in depth, getting out for electric cable complete in any type of soil complete all as specified & directed
Removing surplus excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 m above starting point all as specified and directed.
Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover class LV, type I, flat size 250mm x 150mm x 40mm laid in trenches for protection of cable complete all as specified and directed.
M&L for sand cushioning to under ground cable with locally available dry sand for protection of cable 8cm thick before laying of cable and 15 cm thick after laying and stretching the cable below the bricks/PCC cover ,punning of sand using suitable T&P as per site requirement complete all as specified and directed. Note- Punned thickness of sand i.e 18 cm shall be considered for measurement purpose.
Disconnecting and taking down old/unsv APFC Panel of any type/capacity complete all as specified & directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below the ground level connected to GI strip 32x6 mm by means of bolts nuts check nuts and washers of galvanised iron & GI pipe 40 mm bore 'light grade' for protection of earth strip, PCC chamber, RCC cover 50 mm thick with 8 mm dia bars, funnel etc all as shown in electrical plate No. 3 of MES SSR part-I including excavation & earth work and connecting the earthing to an earthing point/APFC panel and testing on completion complete all as specified & directed.
Supply, Install, testing and commissioning of Hi-wall mounting air cooled inverter split type Air conditioner units complete with cordless LCD remote control unit and with turbo cool, stabilizer free operation, energy saver, anti corrosive blue fins for protection in built air ioniser and plasma filter for better indoor air quality with 5 star rating and the out door unit will be fixed in open space with proper foundation or on wall with proper fixing/supporting stand arrangements including 3 mtr suction & discharge refrigerant copper pipe line with high EER of 1.5 TR Capacity complete all as specified and directed.
Supply, Install, Testing and Commissioning of window type Air conditioner inverter type, 5-star energy rating, 1.5 TR capacity, multi stage filtration, LCD remote control, stabilizer free operation, digital temperature display including positioning in new opening, alignment, providing and fixing of MS supporting frame for mounting AC including welding, grouting and coated with anti-rust paint including anti vibration rubber pads, plastic rain protection hood/louver cover over external AC face, providing and fixing 25 mm thick thermacol or PU foam insulation around the gap between wall and AC unit including connected necessary civil works for sealing, plastering around the unit complete all as specified and directed.
S&F sheet metal enclosure with socket plug top and neutral enclosure with a two pin and earh plug and socket complete with one SPN MCB 20 Amps 'C' curve type, complete all as specified and directed.
S&F copper tubing for refrigerant suction line of Split AC of size 15 mm drawn through pipes/ fixed to walls/ laid on floor or roof in all respects, complete all as specified and directed.
S&F copper tubing for refrigerant discharge line of Split AC of size 6 mm drawn through pipes/ fixed to walls/ laid on floor or roof in all respects, complete all as specified and directed.
S&F heat insulation superior quality nitrile rubber of 9 mm thickness, ISI marked for copper tubing of any size of refrigerant line including necessary clamps, PVC tape knots, in all respects complete all as specified and directed.
S&F in replacement Sub main wiring with four single core 2.5 sqmm PVC insulated ,unsheathed , FRLS multistranded copper conductor 1100 volts grade cable in and including heavy grade PVC Casing & Capping ISI marked broken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 2.5 sqmm PVC insulated,unsheathed, FRLS multistranded copper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified and directed. Note - Two runs of 2.5 sqmm single core cable and one run of 2.5 sqmm earth wire including PVC casing & capping together shall be measured as one unit.
M&L for cutting of existing stone masonry wall for crossing the suction discharge pipe line and electric line connection of split type Air conditioner and after the connection necessary cement work will be provided for making the surface as good complete all as specified and directed.
S&F AC drain hose outlet PVC Pipe of standard size 20mm complete all as specified and directed.
S&F Copper cable of 2.5 sqmm four core for wiring control from outdoor to indoor unit complete all as specified and directed.
M&L for point wiring concealed type with 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, including metal flush box of 1.60 mm thick suitable for modular switches/ sockets/fan regulators including modular white cover plate and modular metal flush box with frame of required modules at site, blanking plates, brass screws, cup washers etc including all cutting / chases etc in stone/ brick masonary/ walls, pinning in stone walls / brick walls and pointing in cement mortar 1:3 to ends or edges of landing etc for concealed conduit wiring using heavy duty stone drilling/cutter machine and making good to the disturbed surfaces to match the existing complete all as specified and directed.
Shanthi Construction (BID ID -3489908)
RAMSON TRADERS (BID ID -3496529)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
Tender_8421.pdf
Tender Documents • 0.49 MB
SOC_8421.pdf
Additional Documents • 0.01 MB
BOQ_828410.xls
BOQ • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .