| 1 | L1₹1.4 CrAccepted-AOC DIGAMBAR CHUCK JORHAT | JORHAT | ₹1.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.5 Cr+₹11.3 L (8.13%)Rejected-AOC GOLAGHAT | GOLAGHAT | ₹1.5 Cr+₹11.3 L (8.13%) | L2 | Rejected-AOC L2 |
Tender Value
₹1.5 Cr
EMD Value
₹2.9 L
Closing Date
21 Aug 2024, 4:00 pmClosed
S.E. P.W.D. Jorhat Road Circle
o/o the S.E. P.W.D. Jorhat Road Circle
Utility shifting (Shifting of Electrical lines) for the work Construction of R.O.B. in replacement of Railway Level crossing gate No. FM-72 at Cinnamora on Jorhat Mariani Mokochung Road in the district of Jorhat, Assam under construction of ROBs on
2024_PWD_38369_1
SE/JRC/NIT/ 2022-23/ 3
Open Tender
Electrical Works
Item Rate
180 days
Jorhat
Please Refer Tender documents
6 documents required · 6 mandatory
₹4,500
₹2.9 L
Yes
13 Sept 2024
12 Aug 2024
22 Aug 2024
12 Aug 2024
21 Aug 2024
12 Aug 2024
Amount
A. Construction of composit and individual 11 KV and LT Line along with a new 100 KVA Sub-Station and two new structure for existing Cinnamora 250 KVA and Latif Nagar 63 KVA DTR due to dismantling of existing line parameters
11/0.4 KV 100 KVA DTR (4 Star) BIS Level-2
G.I Steel Tubular Pole SP 76
G.I Steel Tubular Pole SP 66
G.I. Steel tubular Pole SP 22
ACSR RACCON Conductor
11 KV 1C x 241 sqmm AAAC Covered conductor
GI ch cross arm (75x40x6)mm
GI Ch Cross Arm (100 x 50 x6x2200 mm)
Termination Kit for 11 KV 1cx241 sqmm AAAC Covered Conductor
GI 11 KV T cross arm wirh wangle size 50x50x6 mm
GI Angle (50x50x6) mm
11 KV polymeric Pin Insulator
11KV Polymeric Disc Insulator 70 KN
H/W fitting for Disc insulator B&S 70 KN Tension Type
11 KV 9KA Lighting Arrestor Line type
11 KV GOAB Switch 400 Amp
11 KV DO Fuse set 200 A Assembly
Pole clamp of G.I Flate 50x6mm
HT Stay Set
11 KV Guy Insulator
GI Wire Stay Wire 7/100 SWG
GI wire 6 SWG
GI Wire 8 SWG
GI Nuts & Bolts with GI Washer (Assorted)
DTR Cubical for 100KVA DTRS (Comprising of requisite one Microprossessor based MCCB for incomming Three TM release MCCB for outgoing static TVM, CT, Vmeter, Ammeter etc.)
DTR Cubical for 250 KVA DTRS (Comprising of requisite one Microprossessor based MCCB for incomming Three TM release MCCB for outgoing static TVM, CT, Vmeter, Ammeter etc.)
CI Earth pipe 1.8 m inner dia 100 mm, Outer dia 110 mm with perforated holes of 15 mm dia at 30 cm interval along length of the pipe
ABC 1.1 KV (LT) Grade (Insulated Messenger cum neutral) 3cx120+1Cx95 sqmm (Messenger cum Neutral)
ASA Distribution box with pre-fitted lug for 250 A 3 Ph 10 connectors with Spring Loaded Busbar System for service connection
LT XLPE Cable 1 Core 185 sqmm (Aluminium)
LT XLPE Cable 1 Core 120 Sqmm (Aluminium)
LT Stay Set
LT Guy insulator (Porcelain)
GI Wire Stay Wire 7/14 SWG
Anchore Clamp Wedge Type LT ABC as per NFC Standard
Cable and caps for ABC Cables
Cable Tie
Steel Strap for installing DB Size 20 mm x 1m long
Insulating piercing connector IPC P2 x 95 for DB Charging as per NFC
Insulated crimping type midspan joint (Set contains 5 Nos. ferrules as per cable) as per NFC Std.
Aluminium Lugs-185 sqmm
Aluminium Lugs-240 Sqmm
GL Barbed wire Type A
HT Danger Plate
Suspension clamp ABC as per NFC Standard
Grouting & Muflering of steel tubular pole of type SP-22 as per specification and drawing with minimum planting depth of 2.15 m (Using PCC)
Grouting & Muflering of steel tubular pole of type SP-66 and SP-76 as per specification and drawing with minimum planting depth of 2.15 m (Using PCC)
Tranformer Pad for station transformer complete as per specification
Grouting of stay set with PCC and Boulder
DTR Fencing
B. Dismantling of 11 KV and LT Line along with Cinnamara 250 KVA DTR
11/0.4 KV 250 KVA DTR Copper wound - BIS Level-2
11/0.4 KV 63 KVA DTR Aluminium Wound BIS level-2
PSC Pole 9.75 mtr
PSC Pole 7.5 m
ACSR "RACCON" CONDUCTOR
ASCR :WEASEL" CONDUCTOR
GL 11 KV T Cross Arm wirh Wangle size 50x50x6 mm
GI Ch Cross Arm (75x40x6x2200)mm
11KV Pin Insulator (Porcelain)
Disc Insulator (Porcelain) 45 KN (B&S Type)
H/W fitting for Disc Insulator B&S 70 KN Tension Type
11 KV 9KA Lighting Arrestor Line Type
11 KV GOAB Switch 400 Amp
11 KV DO Fuse 150 A
Pole clamp of G.I Flate 50x6mm
C. Construction of 11 KV and 3 PH 4 Wire LT Cable underground Railway Track crossing between KM 73/5 and 73/6 at Cinnamora Tiniali (11 KV Cinnamora Feeder)
G.I Steel Tubular Pole SP-66
G.I Steel Tubular Pole SP 22
11 KV XLPE Cable 1 Core 400 sqmm (Aluminium)
XLPE Cable Jointing kit - 1.1 KV (LT) Outdoor Type
Cross Linked Polyethylene cable 1.1 KV (LT) Grade (armoured) (Aluminium) 4C x 300 sqmm
11 KV Cable Kit for XLPE 1 Core 400 sqmm (Outdoor)
CI Spun Pipe Class 1A Type 300 mm dia 5.5 m length
Socket for CI Spun Pipe 300 mm dia
HDPE pipe PE100 Grade 110 mm outer dia
HDPE pipe PE100 Grade 315 mm outer dia
GI angle (50x50x6)mm
GI Ch Cross Arm (75x40x6x2200)mm
Pole clamp of G.I Flate 50x6mm
11 KV Polymeric Disc Insulator
H/W fitting for Disc insulator B&S 70 KN Tension Type
CI Earth pipe 1.8 m inner dia 100 mm, Outer dia 110 mm
GI Wire 8 SWG
GI Nuts & Bolts with GI Washer (Assorted)
12 KV 9KA Lighting Arrestor Line type
HT Stay Set
11 KV Guy Insulator (Porcelain)
GI Wire Stay Wire 7/10 SWG
HT Danger Plate
Grouting & Muflering of steel tubular pole of type SP-22 as per specification and drawing with minimum planting depth of 2.15 m (Using PCC)
Grouting & Muflering of steel tubular pole of type SP-66 and SP-76 as per specification and drawing with minimum planting depth of 2.15 m (Using PCC)
J.B. Engineers & Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .