Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.2 LAccepted-Finance 5574 A KANSHI RAM MARKET NEW CHANDRAWAL KAMLA NAGAR DELHI 07 | 1 | Accepted-Finance 1 |
Tender Value
₹6.5 L
EMD Value
₹12,970
Closing Date
27 Feb 2024, 11:00 amClosed
Electrical Work (EnM)-NZ
Office of the Executive Engineer,EE(Elec-I) Division, NZ
Improvement of piping arrangement for discharge of storm water and other allied work at RUB Mundka-2 pump house under Narela zone.
2024_MCD_187431_1
MCD/TR/2019/2024_17_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
Narela, RANI KHERA
4 documents required · 4 mandatory
₹590
₹12,970
1 Mar 2024
20 Feb 2024
27 Feb 2024
20 Feb 2024
27 Feb 2024
21 Feb 2024
Amount
PART 1 (DSR Items)
1.15.3:Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C
1.8.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
OD27599/2023-2024:DSR22 1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
OD27600/2023-2024:DSR22 1.17.21 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm
OD27601/2023-2024:DSR22 1.17.30 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 6 sq. mm
OD27602/2023-2024:DSR22 1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
OD27603/2023-2024:DSR22 1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
1.7.5:Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 10 sq. mm + 1 X 6 sq. mm earth wire
OD27604/2023-2024:DSR22 1.23.1 Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch
OD27605/2023-2024:DSR22 1.23.4 Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 amp socket outlet
OD27606/2023-2024:DSR22 1.30 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
OD27607/2023-2024:DSR22 2.12.2 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
OD27608/2023-2024:DSR22 2.10.1 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
OD27612/2023-2024:DSR-22 2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 12 way double door
OD27609/2023-2024:DSR22 1.50.1 Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required. Upto 450 mm sweep
OD27610/2023-2024:DSR22 5.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
OD27598/2023-2024:DSR22 5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD27611/2023-2024:DSR22 7.6.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
OD27616/2023-2024:DSR-22 2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A
OD28369/2023-2024:3 mm thick phenolic laminated sheet
PART 2 (AR Items)
122.2.149A.(b):Providing, lowering and fixing/placing in vertical position MS Black casing medium ( B-class) pipe of following size conforming to IS 1239/3589 Part-I (2004) at all depth, both ends threaded as required. 150mm(Nominal Bore)
122.2.158.(b):Supplying and fixing following sizes of insulated steel flexible safety rope for holding submersible pump set i/c clips etc complete as reqd. 10 mm
122.1.47:Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required.
122.2.126:SITC of wall mounted fan 400mm sweep rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
122.2.28:SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
122.2.111:supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged)
OD27617/2023-2024:Providing and fixing MS flange with required nut bolts & packing sheets etc. complete as required of following Dia 150 mm (10 mm thickness).
OD27618/2023-2024:Providing & fixing of M.S. Bend with required nut bolts & packing sheet etc. complete as required of following dai :- 150 mm short bend c-class
OD28370/2023-2024:Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming to IS 5312 (Part 1 & 2), PN 1.6 complete as required NRV 150 MM
OD27620/2023-2024:Submersible Non-Clog Sludge Pump, Make- Mody pumps, Model - NC10M, 10HP/3PH/50HZ/415V/2800 RPM, features - Tandom TC/TC and TC/TC Mechanical sealS ,4 " Hose SS outlet, Insulation class H, SS410 Hardended Impeller, SS431 Shaft, SS304 volute & Hardware, water proof/Oil EPR
122.2.156.(b):P&F following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd. 3x 4 sq.mm
Bidder Name
Soni Sales & Service
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .