Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.1 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹21.7 L+₹61,423.50 (2.91%)Rejected-Finance | 2 | Rejected-Finance Not Lowest |
Tender Value
₹21.2 L
EMD Value
₹42,400
Closing Date
19 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Abohar
Garrison Engineer Abohar Pin-152116
Provn of 03 x oil stores at Inf Bn and other sanctioned works at Mil Stn Abohar
2021_MES_415709_1
GE ABH-48/20-21
Open Tender
Civil Works
Item Rate
180 days
Abohar Mil Stn
MES Registered Contractor enlisted in class E Category a (i) having deposited standing security of Rs 50000 with departments. Contractors not registered in MES should meet the MES enlistment criteria corresponding to appropriate class and category
5 documents required · 5 mandatory
₹500
Garrison Engineer Abohar
₹42,400
Yes
26 Feb 2021
29 Jan 2021
22 Feb 2021
29 Jan 2021
19 Feb 2021
6 Feb 2021
60 days
Amount
SCHEDULE 'A' SECTION I (B&R Portion)
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundations etc or manholes, cesspits, pipes and cables etc. not exc 10 Sqm on plan and getting out in soft / loose soil all as specified and directed by Engineer - in - Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers of soft / loose soil not exceeding 25cm thick all as specified and directed by Engineer - in - Charge.
M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete all as specified and directed by Engineer - in - Charge
M & L form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge.
M & L form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface of concrete all as specified and directed by Engineer - in - Charge.
Form work to sides and soffits of floor or roof beams, lintels cantilevers, shelves including supports, over hangs and the like for rough finished surfaces complete all as specified and directed by Engineer – in – Charge.
M & L form work to soffits of suspended slabs such as roof slab and similar work not exceeding 200mm thick for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge .
M & L form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge.
Form work to chullah hoods, chajjas, troughs and similar items including edges with rough finished surface of concrete all as specified and directed by Engineer - in - Charge.
M & L mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as specified and directed by Engineer - in - Charge .
All as per Srl item No. 11 here in before but 5mm and over for as in stirrups, spacers and binders all as specified and directed by Engineer - in - Charge.
M & L Reinforced cement concrete M-25 design mix type using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and the like complete all as specified and directed by Engineer - in – Charge.
M & L Reinforced cement concrete M-25 design mix type using 20 mm graded stone aggregate as in columns, pillars, piers, posts and struts all as specified and directed by Engineer - in - Charge.
M & L Reinforced cement concrete M-25 design mix type using 20 mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5mtr clear span etc complete all as specified and directed by Engineer - in – Charge.
M & L Reinforced cement concrete M-25 design mix type using 20 mm graded stone aggregate as in slabs supported on walls, beams, columns and in shelves, the likeall as specified and directed by Engineer - in – Charge.
M & L Reinforced cement concrete M-25 design mix type using 20 mm graded stone aggregate as in chajjas, fins, fascias, louvers, parapets and railing etc and the like all as specified and directed by Engineer - in - Charge.
Spreading and levelling of earth in layers not exceeding 25cm thick and well ramming including watering as required all as specified and directed by Engineer - in - Charge.
M & L for 75mm thick cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate as in sub floors, sub bases etc all as specified and directed by Engineer - in - Charge.
M&L for 75mm thick PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregate as in Plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joint at the rate of 3 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and directed by Engineer-in-Charge.
S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by Engineer-in-Charge.
S & F 4mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane all as specified and directed by Engineer - in - Charge .
S & F Steel rolling shutters, having thickness of laths 1.25mm, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated gear operated type with bevel gear box and crank handle complete all as specified and directed by Engineer-in-Charge.
S & F Ball bearing for rolling shutters complete all as specified and directed by Engineer-in-Charge.
M & L Sand filling under floors or in foundations including watering and consolidation all as specified and directed by Engineer - in - Charge.
M&L Continuous brick edging using old size burnt clay bricks of sub class B; with width equal to width of brick laid dry on end vertically (including necessary earthwork & embedding bricks in the ground) all as specified and directed by Engineer - in - Charge.
M&L machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid over and including 15mm thick screed bed in cement mortar 1:6 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
M&L machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid over and including 10mm thick screed bed in cement mortar 1:4 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
M&L rendering 10mm thick in CM 1:6 on fair face of brick or concrete surface, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5mm thick in CM 1:3 on ceiling, finished the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge.
M&L for two coat of oil bound distemper on new plastered wall surfaces of walls paint over 3mm thick wall care putty including necessary preparation of surfaces all as specified and directed by Engineer-in-Charge.
M&L three coat of white wash on ceiling including necessary preparation of surfaces all as specified and directed by Engineer-in-Charge.
Providing and applying microfibre reinforced UV resistant Acryclic polymer coating three coats having solid contents 69% polymer content 35% & tensile strength 2.6 N/mm2 of Dr. Fixit Newcoat/stat/Parex or equivalent with a paint brush over existing roof surface after removal of all loose material, lime dust etc. with wire brushes, coir brushes from roof surface to get absolutely cleaned surface free of foreign containment filling of cracks wherever found with polymer based mortar, and after repairing the surface apply primer coat with Dr. Fixit Primeseal. Polyester reinforced fiber net laid on the surface after the first coat and all the joints of bricks is repaired by polymer based mortar. Undulation on the surface repair before executing the water proofing treatment including 15mm thick plaster in CM 1:4 as screed finished even joint of slab and wall of roof complete all as specified and directed by Engineer-in-charge.
Supply only integral waterproofing compound all as specified and directed by Engineer - in – Charge.
S&F Factory made box type steel window with hung shutter both glazed and gauged, shutter frame 60x25mm ERW hollow 'P' section with wall thickness not less than 1mm fixed to pressed steel frame 120mm x 70mm x1.6mm thick including fixing glazed portion, iron grills 8mm suare MS bar hunges with steel handle and fitting, lugs etc, including one coat of primer complete all as shown in drg No BTD 889 sheet 1/4 to 4/4 specified and directed by Engineer-in-charge. (Note:- Wire mesh and glass shall be measured and paid separately under relevent items of sch/BoQ)
S&F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed by Engineer-in-Charge.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in loose / soft soil all as specified and directed by Engineer - in – Charge.
M & L for broken bricks hard core of gauge not exceeding 63mm, deposited, spread levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed by Engineer - in - Charge.
M&L for PCC 1:4:8 Type D-2 100 mm thick as in sub base all as specified and directed by Engineer-in-Charge.
M&L for machine pressed precast concrete coloured with grey cement and pigment interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and directed by Engineer-in-charge.
M&L for 50mm thick layer of Fazilka sand cushoning under interlocking paving block flooring all as specified and directed by Engineer-in-Charge.
M&L Brick work with old size burnt fly ash bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge .
M & L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even & smooth without using extra cement all as specified and directed by Engineer - in - Charge .
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed by Engineer - in - Charge.
Demolition of brick work built in cement mortar all as specified and directed by Engineer - in - Charge.
Taking down cement plaster/ terrazo finish on brick wall including racking out joints, hacking for keys scrubbing down with water all as specified and directed by Engineer - in - Charge.
Demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise specifically provided for all as specified and directed by Engineer - in - Charge .
S & F framed work such as grills, grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work for water tanks and similar work conforming to Fe-290 Gde E-165 all as specified and directed by Engineer - in - Charge.
M & L providing two coats of synthetic enamel paint and a coat of red oxide primer on new steel surfaces including preparation of surface of any description over 10 cm width or girth all as specified and directed by Engineer - in - Charge .
Dismantling floor or wall tiles including cement mortar bedding, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer - in – Charge.
M&L for joint free Non skid ceramic coloured tile 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18sqm, in floors etc. over and including 15mm thick screed and bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or colour cement to match with the existing surface etc all as specified and directed by Engineer-in-Charge.
Taking down Shutter of any description excluding 1 Sqm but not excluding 2 Sqm each and refixing it in same opening after resecuring or erasing & adjusting all as specified and directed by Engineer-in-Charge.
S & F Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on frame as per specifications and drawing complete all as specified and as directed by Engineer-in-Charge.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all specified and directed by Engineer-in-Charge.
M & L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & smooth without using extra cement all as specified and directed by Engineer - in - Charge .
M&L two coats of cement base paint over new plastered surface including preparation of surface complete all as specified and directed by Engineer-in-charge.
M&L for PCC (1:2:4) type B0 (using 12.5 mm graded stone aggregate) as in coping of drains, benching and channel of drains, and also for bed blocks for embeddings MS rungs of septic tank all as specified and directed by Engineer-in-charge.
M&L for two coat of oil bound distemper over a coat of clearcolle primer on newly plastered surface of wall including preparation of surface complete all as specified and directed by Engineer-in-charge.
Supply and fixing drapery curtain rod 25mm dia, fancy type, fabricated out of mild steel sheet not less than 20 gauge, including brackets and pair of decorated end knobs (finials), stop roller etc., pretreated powder coated natural color complete all as specified and directed by Engineer-in-charge.
SCHEDULE 'A' SECTION-II (E&M PORTION)
M&L point wiring (CONCEALED) for using 1.5 sqmm nominal cross sectional area copper conductor multistranded , PVC insulated unsheathed, FRLS cables in and including using PVC conduits not less than 20mm dia and fittings, including pressed steel terminal switch boxes, 3mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multi-multistranded copper conductor, FRLS, green PVC insulated unsheathed earth wire and connecting to earth dolly using color code as per IS and making good all disturbed work to match the existing for One light/fan/bell point controlled by one 5 Amps one way switch and all as specified and brass screws, washers etc complete all as specified and directed by Engineer-in-Charge.
S & F isolator single pole and neutral 63 Amp 240 volt all as specified and directed by Engineer – in – Charge .
S & F isolator single pole 40 Amp 240 volt all as specified and directed by Engineer – in – Charge .
Supplying and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable XLPE aluminium conductor armoured PVC sheathed 25 Sqmm 2 core nominal cross section in service connections all as specified and directed by Engineer – in - Charge.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundations or laying cables/ pipes etc and getting out in soft / loose soil all as specified and directed by Engineer - in - Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers of soft / loose soil not exceeding 25cm thick all as specified and directed by Engineer - in - Charge.
Removal of excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed by Engineer - in - Charge.
M & L sand cushioning for under ground cable 23 cm thick (one layer of 8 cm thickness before laying the cable and other layer of 15 cm thickness after laying the cable) all as specified and directed by Engineer-in-Charge.
S & F 40mm bore light grade tube galvanised with all fittings laid in trenches or fixed to poles etc. all as specified and directed by Engineer - in – Charge.
Supply and fix flame proof weather proof CMRI certified LED flame proof 2 x 16 W LED tube light fixture suitable for gas/vapor group of II A and II B Zone-I, IP-65 protection. (Make Crompton model : EXTN 2 LT8-16/20) of 4 feet long made of Aluminium alloy LM6 with electronic ballast, bipin holder, connector blocks etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable as per requirement size complete all as specified and directed by Engineer-in-Charge
Supply and fix flame proof weather proof bulk head metal hide light fitting 2x36 W flame proof type FLP-WP of 1x70 W built in control gear box made of aluminium alloy LM6 with all accessories, ballast lamp holders etc and internally prewired complete all as specified and directed by Engineer-in-Charge. duly CMRI certified LED flame proof 60/70 Watt die cast aluminum housing with heat resistant toughened glass IP-65 protection complete all as specified and directed by Engineer-in-Charge
Supply and fix flame proof switch rotary type with termination box in LM6 , 16 Amp single pole 250 volts complete all as specified and directed by Engineer-in-Charge.
S&F outdoor type distribution board SPN 4 way (heavy duty), Double door type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces complete all as specified and directed by Engineer-in-charge. Make : Legrand/L&T Hages/C&S/ INDO KOPP/ Indo Asian/ Standard/Havells
Earthing complete with galvanised steel earth plate electrode 60cmx60cm/60cm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of chrcoal dust and common salt, connected to galvanised iron earth wire lead of 4 mm dia fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and water pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and directed by Engr-In-Charge Note : (a) 20mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (b) GI strip upto DBs earth connection in included in this item. (c) GI Pipe 40mm dia protection pipe shall be provided
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable complete all as specified and directed by Engineer-in-charge.
SUDESH ENTREPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .