Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.3 CrAccepted-AOC 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | ₹1.3 Cr | L-1 | Accepted-AOC Lowest bidder for the subject work. |
| 2 | L-2₹2.0 Cr+₹76.8 L (60.9%)Rejected-Finance | ₹2.0 Cr+₹76.8 L (60.9%) | L-2 | Rejected-Finance Other than lowest bidder. |
| 3 | Rejected-Technical OPP SHRI NAVNIKETAN H S SCHOOL CHHOLA KANCHI BHOPAL M P | BHOPAL | MADHYA PRADESH | 462010 | - | - | Rejected-Technical CONDITIONS NOT COMPILED WITH |
| Sl No | Description | Qty | Unit | Raja enterprises L2 | POONAM ELECTRIC INDUSTRY L1 |
|---|---|---|---|---|---|
| 0.00GENERAL SUMMARY | |||||
| 1.00Lump sum price worked out by the contractor against Schedule ‘A’ Part- I (BUILDING WORKS) for the following building works:- | |||||
| 1.01 | (a) Lump sump amount worked out by the contractor for Design, development of structural drawings as per the architectural drawing Nos CWE/ARCH/31/2025 Sheet 1/4 to 4/4 and Construction of OTM Living accomodation and battery bank room as per architectural drawings, structural drawing, TD drawings, schedule of finishes & given Bldgs construction wrt Architectural Plan built in permanent specification with RCC framed construction based on EPS 3D technology construction including ATT, WPT mosquito proofing with flooring and all other internal services, etc complete all as specified and as directed.
NOTE:- The structural design and drawing shall be got vetted from any IITs/NITs before execution of work by the contractor. | 1 | Block | 1,49,50,000 ₹1,49,50,000 | 94,70,430 ₹94,70,430 Lowest |
| 2.00 | Lump sum price worked out by the contractor for EXCAVATION AND EARTH WORK as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately) | 1 | Lump Sum | 4,75,000 ₹4,75,000 | 4,05,000 ₹4,05,000 Lowest |
| 3.00 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-III (Ref prepriced schedule attached seperately) | 1 | Lump Sum | 4,50,000 ₹4,50,000 | 3,60,000 ₹3,60,000 Lowest |
| 4.00 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-IV (Ref prepriced schedule attached seperately) | 1 | Lump Sum | 1,05,000 ₹1,05,000 | 90,000 ₹90,000 Lowest |
| 5.00 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part- V (Ref prepriced schedule attached seperately) | 1 | Lump Sum | 1,23,000 ₹1,23,000 Lowest | 1,26,000 ₹1,26,000 |
| 6.00 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately) | 1 | Lump Sum | 75,000 ₹75,000 | 72,000 ₹72,000 Lowest |
| 7.00 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part- VII (Ref prepriced schedule attached seperately) | 1 | Lump Sum | 1,02,000 ₹1,02,000 | 90,000 ₹90,000 Lowest |
| 8.00 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part- VIII (Ref prepriced schedule attached seperately) | 1 | Lump Sum | 1,75,000 ₹1,75,000 | 1,44,000 ₹1,44,000 Lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
11 Oct 2025, 6:00 pmClosed
Col Pawan Kumar, CWE
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
PROVN OF OTM LIVING ACCOMODATION FOR WOMEN MILITARY POLICE AT BHOPAL UNDER GE DRONACHAL
2025_MES_722225_1
84049/E8
Open Tender
Civil Works
Item Rate
270 days
Dronachal
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹1,000
Yes
GE Dronachal
₹2.1 L
Yes
1 Dec 2025
23 Jul 2025
13 Oct 2025
23 Jul 2025
11 Oct 2025
22 Sept 2025
23 Jul 2025 - 22 Sept 2025
Amount
GENERAL SUMMARY
Lump sum price worked out by the contractor against Schedule ‘A’ Part- I (BUILDING WORKS) for the following building works:-
(a) Lump sump amount worked out by the contractor for Design, development of structural drawings as per the architectural drawing Nos CWE/ARCH/31/2025 Sheet 1/4 to 4/4 and Construction of OTM Living accomodation and battery bank room as per architectural drawings, structural drawing, TD drawings, schedule of finishes & given Bldgs construction wrt Architectural Plan built in permanent specification with RCC framed construction based on EPS 3D technology construction including ATT, WPT mosquito proofing with flooring and all other internal services, etc complete all as specified and as directed. NOTE:- The structural design and drawing shall be got vetted from any IITs/NITs before execution of work by the contractor.
Lump sum price worked out by the contractor for EXCAVATION AND EARTH WORK as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-III (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-IV (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part- V (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part- VII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part- VIII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for ROAD, PATH CULVERT WORKS as listed in Schedule ‘A’ Part- IX (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for COMPOUND WALL/GATE WORKS as listed in Schedule ‘A’ Part- X (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for RAIN WATER HARVESTING WORKS as listed in Schedule ‘A’ Part- XI (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for HOT WATER SUPPLY WORKS as listed in Schedule ‘A’ Part- XII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SUMMER APPLIANCES WORKS as listed in Schedule ‘A’ Part- XIII (Ref prepriced schedule attached seperately)
SCH 'A' Pt - XIV (MISCELLANEOUS PARTS)
S&F LED bulb 09 watt, 900 lumens out put,6000 to 6500K suitable for B-22 base complete all as specified and directed
Supply and fixing LED light fitting with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
S&F 25W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 110lm/W. The color temperature is 6000 to 6500 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete all as specified and directed.
Supply & fix factory made epoxy powder coated Load line Distribution Board with metal doubledoor (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for and suitable for housing 01 No 63 Amp MCCB 4 pole ,415 Volts, 16 KA along with cable ties for cable management, top and bottom removeable gland plates incl suitable cable lugs for connection at incoming and otgoing complete all as specified and directed by Engr-in-charge.
Supply & fix factory made epoxy powder coated Load line Distribution Board SPN-6 ways with metal doubledoor (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp rated bus bar double door, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts complete all as specified and directed.
Supply & fixing Square shape 15 watt 230 volts AC recessed/surface mounted with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED suitable for roof ceiling including connecting up with 2/3 core flexible copper conduct.
M&L cutting PCC/floor/road for taking out/ laying of cable , GI earth wire etc in protection pipe and making good, including material as per existing after laying of pipe for cable protection, GI wire etc all as specified and directed size of trench not more than 0.30 x 0.30 m complete all as specified and directed.
Refixing/Shifting of existing LT Pannel at other places complete all as specified and directed. Note-Cables are measured and paid separtelly on relevent items.
Cutting of any type of pipes in any position for insertion of new tees , branches, etc for the 50 mm sizes complete all as specified and directed.
Shifting of any size of pipe line complete all as specfied and directed. Note-Pipes are measeured and paid saperatelly .
Supply and install desert cooler electric driven (single phase) three speed having nominal air flow capacity 5000CFM per hour, with propeller ISI cooler fan motor copper winding single phase fitted with / having aluminium blade of minimum size 500 mm ,submersible pump, Max power consumption of 325 Watts. Cooler body made out from 20 gauge mild steel galvanized iron sheet & water tank made out of 18 SWG, having capacity 40 Ltr minimum including three louvers with wood wool pad, flexible PVC distribution pipes and 3 way junction complete all as specified and as directed by Engr-in-Charge and of standard make as approved by GE. NOTE : 1. Three speed switch ISI Marked rotary type for propeller fan and one way switch pump with separate control. The switches shall have marking off- Low - medium and high. 2. float valve on water supply connection shall be deemed to be included in unit rate quoted
RENEWAL ENERGY (SOLAR POWER PLANT)
Supply, installation, testing and commissioning of Solar roof top panel having capacity not less than 10 KW and capable to provide backup for minimum 6 hr continuous for 10kw peak load. The system has fallowing specification and make. 01 Solar PV Modules 590 Wp or above Approved Nos. 30 02 Complete Module Mounting Structure Set 1 03 Power Conversion System 1 04 Battery Bank-70 kWh (Pack Nominal 500 V (LFP) Nos. 1 Maximum weight of battery bank: 1050 kg 05 2x2.5 sq mm PVC Insulated Copper Cable RM Approx. 20 (Shall be supplied if extra needed on actual basis) 06 2x4 sq mm PVC Insulated Copper Cable RM Approx. 40 07 2x6 sq mm PVC Insulated Copper Cable RM Approx. 40 8 2x10 sq mm PVC Insulated Copper Cable RM Approx. 40 9 DC Distribution Board Set 01 10 AC Distribution Board Set 01 11 Earthing Set 4 12 Lighting Arrester Set 1 13 Installation Accessories Set 1 14 Pipe & Tools Composite Set 1 15 Cables, Lugs, Spare part Material Set 1
Item 14.14 Contd……/ A. Technical Specification of PCS: Battery type: LFP Battery nominal voltage range: (200-800 V) Number of battery input: Minimum 1 Charging strategy self-adapting to BMS PV string input voltage: 200-650 V Start-up voltage = 160V Rated AC Input/Output Active Power(W): 20 kW Max. Continuous AC Passthrough: 45 A Peak Power (off-grid) (W): Minimum 2 times of full load power rating, 0.17 minute Audible noise: less than 45 dB Operating Temperature Range (℃):-40 to +60℃, >45℃ Derating Power Factor Adjustment Range: 0.8 leading to 0.8 lagging Rated Input/Output Voltage/Range (V): 220/380V, 230/400V 0.85Un-1.1Un Rated Input/Output Grid Frequency/Range (Hz): 50 Hz Grid connection form:3L+N+PE Total Current Harmonic Distortion THDi: <3% (of nominal power) Max. Efficiency: 97.6% Equipment Protection: DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level Surge protection: TYPE II(DC), TYPE II(AC) Communication Interface: RS485/RS232/CAN Over Voltage Category: OVC II(DC), OVC III(AC) Grid Regulation: IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140 Safety / EMC Standard: IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Item 14.15 Contd……/ B. Major Components & Technical Specification: (a) Solar PV Module: - TOPcon Module with efficiency > 20% and IEC 61215 & IEC 61730 MAKE WAAREE/Vikram Equivalent. (b) Module Mounting Structure: - Galvanized MS module mounting Structure with minimum thickness of galvanization 70 micron with SS nut & Bolts. Designed to withstand wind speed as per IS875 and seismic factor of the site. MAKE-Apollo/JSW/Tata steel (c) Inverters: - Three -phase hybrid inverters ideal for rooftop solar systems complying with all requirements for IP 65 equivalent protection – their housing provides reliable protection from dust and water, including high pressure washing. With Fast MPPT tracking and a wide input voltage range to ensure the high levels of efficiency Even at lower radiation. With integrated data-logger to send all important operating data through Internet portal. Warranty: 5 years and extendable under AMC. (d) Distribution Boxes, Cables & Accessories: - An ACDB shall be provided in between PCU and Load/grid interface with a MCB of suitable rating of connection and disconnection of PCU from load. All the cables shall be supplied conforming to IS 1554/694 Part 1 of 1988 & shall be of 1000 V/ 1.1kV grade as per requirement. MAKE-Indexel/Polycab/Keco (e) Earthing & Lighting Protection: - Earthing kits in adequate numbers to properly ground the array structures of the PV yard as per IEE regulation. Lighting and overvoltage protection of the SPV Plant to be provided. (f) Battery Bank: - Battery bank with 8 hrs backup used will be of Battery nominal voltage range: (400-600 V), each cell 3.2 V LFP battery. (Maintenance free) warranty of the battery bank will of 5 Years including battery racks to layout the batteries. C. DETAILS OF THE POWER PLANTS: 1) SPV MODULES: SPV modules shall be designed and manufactured to meet the same recognized standard which must have been used extensively throughout the world for more than a decade with an excellent track record of performance. SPV modules shall generate a peak power minimum 590 Wp or should be of higher capacity at STC. Minimum dimension of the SPV module shall be preferred for mention Wp rating. 2) MODULE MOUNTING STRUCTURE: The modules mounting structure shall be of galvanized sheet/structural with minimum 70 Micron galvanizing, the structure shall be non penetration type as the roof is of EPS technology, it should be blasted roof structure kept on roof. 3) FOUNDATION: The foundation pedestals where-ever necessary shall be concrete. 4) JUNCTION BOX: The junction boxes shall be made up of module cast PVC, dust and vermin proof. The terminals shall be of appropriate size; junction boxes shall have suitable cable entry with suitable glanding arrangement for both input and output cables. Suitable marking on the bus bars shall have to be provided to identify the bus bars etc.
Raja enterprises (BID ID -3440231)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .