| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.6 LAccepted-AOC | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹12.5 L+₹54,120 (4.54%)Rejected-Finance 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹14.1 L+₹2.2 L (18.4%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹15.5 L+₹3.6 L (30.0%)Rejected-Finance MOH HATHITHAN NIGOHI ROAD SHAHJANPUR UP 242001 | SHAHJAHANPUR | UTTAR PRADESH | 242001 | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹16.0 L+₹4.0 L (33.9%)Rejected-Finance | 5 | Rejected-Finance Not being lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
13 Aug 2022, 6:00 pmClosed
HQ CWE Agra
112 Taj Road Agra Cantt
REPAIR / RENEWAL OF INTERNAL ELECTRIFICATION FITTING AND FIXTURE IN OTM ACCN UNDER AGE (I) FATEHGARH
2022_MES_538672_1
86108/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Fatehgarh
MES contractors enlisted in Class E category b(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹500
AGE(I) Fatehgarh
₹40,000
Yes
22 Aug 2022
16 Jul 2022
19 Aug 2022
16 Jul 2022
13 Aug 2022
30 Jul 2022
16 Jul 2022 - 23 Jul 2022
Amount
Taking down copper/aluminium point wiring of any description and in any position (light, fan, socket or power point) complete, including fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and directed.
Taking down Aluminium sub main wiring and making good disturbed surfaces to match with the existing surface of roof/wall/floor complete all as specified and as directed
M&L for point wiring with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed PVC rigid conduit of suitable size medium grade with fittings (ISI marked) sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc complete all as specified and directed for the following- Note- (i) The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
(a) One light/fan/exhaust fan point controlled by one switch.
(b) One 5 pin 5 Amp switch socket combination point on an independent board.
(c) One 5 pin 5 Amp socket point controlled by one switch on same board.
M&L for point wiring with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including surface PVC rigid conduit of suitable size medium grade with fittings (ISI marked) sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc complete all as specified and directed.- Note- (i) The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good with using CM 1:4 and surface finished to match the existing surface & colour.
(a) One light/fan/Holder/exhaust fan point controlled by one switch.
(b) One 5 pin 5 Amp switch socket combination point on an independent board.
(c) One 5 pin 5 Amp socket point controlled by one switch on same board.
All as per item 4 here in before but for one 15 Amp 6 Pin switch socket combination independent with 4.0 Sqmm FRLS unsheathed copper conductor single core multistranded complete all as specified and directed.
S&F switch piano flush type 5 Amp single pole one way complete all as specified and directed.
Fixing only switch piano flush type 5 Amp single pole one way complete all as specified and directed.
S&F switch socket combination 2 in 1 flush type 5 Amp 5 Pin complete all as specified and directed.
Fixing only switch socket combination 2 in 1 flush type 5 Amp 5 Pin complete all as specified and directed.
S&F switch socket combination 5 in 1, 15 Amp flush type complete all as specified and directed.
M & L lamp holder PVC/Polycarbonate type insulated body with back plate angle type for batten fittings incl LED lamp of 12W and colour temp 6500K suitable to fix in angle holder complete all as specified & directed.
Supply and fix electronic fan regulator 5 stepped type complete all as specified and directed
S&F ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
M&L for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 6 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and directed. ( Note :- Two runs of 6 sqmm FRLS and one run of 6 sqmm FRLS copper conductor shall be measured as one unit length.)
Supply and fixing in renewal MCB distribution board SPN 240 Volt 8 way with 200 Amp rated bus bar having IP-43 protection and double metal door concealed in wall including connection with copper thimbles as required complete all as specified and directed.
Ditto all as per item No.15 above but 4 way complete all as specified and directed
S&F in renewal of MCB SPN 40-63 Amp 240 volt 'C' curve complete all as specifed and directed.
S&F MCB in renewal of MCB SP 6 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
S&F in renewal LED battan surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption < 20W, luminaire lumens > 2000 lms, system efficiency of > 120 lumens / W, LED of make : Nichia / Cree / Everlite / Eclison / OSRAM / Lumiled, with LED binding as per ANSI Bin C78 377A, photo biologica safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI > 80, temp range 0 to 45 ºC, driver efficiency > 85%, power facor > 0.95 THD < 20% as per IEC 61000-3-2, colour temp - 6500 K Surge protection 2.5 KV, 50000 burning hrs (min) as per L 70 criteria, two stages isolated constant current operated driver with range 150 - 270 V AC and safety extra low voltage safe level < 60 V DC as per IEC standard with LM 70 & LM 80 certification complete all as specified and directed.
S&F in renewal LED mirror light high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption < 10W, luminaire lumens > 2000 lms, system efficiency of > 120 lumens / W, LED of CRI > 80, temp range 0 to 45 ºC, driver efficiency > 85%, power facor > 0.95 THD < 20% as per IEC 61000-3-2, colour temp - 6500 K Surge protection 2.5 KV, 50000 burning hrs (min) as per L 70 criteria, two stages isolated constant current operated driver with range 150 - 270 V AC and safety extra low voltage safe level < 60 V DC as per IEC standard with LM 70 & LM 80 certification complete all as specified and directed.
S&F in renewal LED security with aluminium pressure die cast housing, high purity PC fresnel diffuser with silicon gaskets for IP-65 protection, power consumption <20 W & luminaire lume > 2500lm and system efficiency > 100lm /W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor > 0.95, suitable for external pole upto 35mm LED Make :- Nichia / Cree / Osram, CRI. 70, ambient temperature range 0-450C, THD < 10% colour temperature 5700 K, surge protection CM 3.5 KV 50000 burning hour as per L70 criteria, multi stage constant current constant voltage operated driver with range 150-270 V AC and safety extra low voltage safe level <60V DC as per IEC standard including GI pipe medium grade ISI mark of size 32 mm dia length not less than 1.5 mtrs bending to shape for fixing light and nuts, bolts, clamp as required to fix to wall complete all as specified and directed.
S&F 42W aesthetically designed 600x600x70 mm LED flat panel for surface mounting which provide soft-light and glare free symmetrical illumination ( Make : Havells Cat No : PLUTOSURFACE 2x2 PLS42WLED857S or equivalent of Philips/Bajaj/C&S)
S&F in renewal suspended / surface mounted with 1X 4' LED luminaire including 15 mm dia BSP steel conducit pipe of suitable length full panel LED luminaire with white powder coated housing acting as heat shrink and frame in CRCA sheet, high efficiency LED grade diffuser, in built electronic driver duly wired up to terminal block, power consumption < 30W, luminaire lumen > 3500Lm and system efficiency > 120 lm/W, CRI>80,, colour temp - 5700 K, Ingress protection IP 20, driver efficiency > 85%, 50000 burning hours (min) as per L 70 criteria, abmient temp 0 to 500C, power factor >0.95, THD <10%, surge protection in CM - 3 KV, two stages isolated constant current operated driver with range 150 - 270 V AC and safety extra low voltage safe level < 60 V DC as per IEC standard with LM 79 & LM 80 certification complete all as specified and directed.
S&F in renewal square slim recess mounted LED down lighter of capacity 15 watts, 240 volts, white powder coated pressure die cast aluminium housing and bottom frame with high transmitive LGP technology, high efficiency non yellowing PMMA diffuser, complete with LEDs driver and accessories pre-wired upto terminal block lumens wattage not less than 15 watts, luminaire lumen output >1500 Lm, ingress protection IP-20, ambient temperature 0-450 C driver efficiency more than 85% power factor above 0.95, Surge protection 3 KV multi stage isolated constant current and variable working votlage 150-270 Volts complete all as specified and directed.
S&F LED 600x600 mm fully diffused recessed LED luminair with high transmitive diffuser 36/37W complete all as specified and directed.
Supply and fixing of VTPN DB suitable for Mounting MCCB as Incomer of rating 100 Amp Vertical distribution board 4 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including MCCB 100 Amp, 16KA, 4 Pole complete electrical connection with aluminium thimbles as required complete all as specified and directed.
S&F in renewal of Busbar chamber in sheet metal enclosure 200 Amp, 8 way TPN 415 Volt of aluminium busbar drilled holes including cadmium coated nuts, bolts, washer etc fixed on wall complete all as specified and directed. (Make: Havells Cat No: IHBC020008 or equivalent in L&T)
Supply and Laying cable XLPE Insulated screened PVC bedded, galvanized steel strip armoured service cable pole to building electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 core complete all as specified and directed.
S&F in renewal of 40 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified and directed .
Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item
Sand cushioning for cables complete all as specified and directed .
Material and labour for old size brick well burnt, laid flat, for cable protection complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in any type of soil complete all as specified and directed.
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any type of soil complete all as specified and directed
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed
S&F in renewal metal clad plug & socket with metal plug top enclosure with a two pin and earth plug top and socket suitable for one single pole MCB 32 Amp complete all as specified and directed.
Disconnecting and taking down old existing UNSV tube light fitting of any description and in any postion down with point wiring including connection complete with all accessories and down rod all complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanised iron or steel all as shown in electrical plate No - 3 connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but without earth lead protection pipe and test on completion after dismantling unserviceable earthing (above GL only) complete all as directed incl dismantling of exsisting earthing. ( Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost.)
MS. BK BROTHERS AND CO
S B ENTERPRISES
avon electric engineering woks
M/S J.B.AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .