| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.0 L+₹2.8 L (8.53%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹35.4 L+₹3.1 L (9.65%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹35.5 L+₹3.3 L (10.1%)Rejected-Finance | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹35.6 L+₹3.3 L (10.3%)Rejected-Finance | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹28.5 L
EMD Value
₹57,000
Closing Date
25 May 2021, 6:00 pmClosed
GE 867 EWS
GE 867 EWS C/O 99 APO PIN 913867
PROVISION OF RETAINING WALL NEAR CONVOY GROUNG AND PROVISION OF STORE ROOM AND ADDITION/ALTERATION TO EXISTING DINING HALL IN BLDG NO. P-174 AT KALIMPONG UNDER GE 867 EWS
2021_MES_437061_1
CA NO GE / 867 / TOKEN / 08 OF 2021-2022
Open Tender
Construction Works
Item Rate
180 days
Kalimpong
Refer tender documents
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹57,000
Yes
28 May 2021
19 Apr 2021
26 May 2021
19 Apr 2021
25 May 2021
4 May 2021
19 Apr 2021 - 27 Apr 2021
Amount
M&L for excavation over areas not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
M&L for Plain cement concrete 1:4:8 mix type D2 (using 40 mm graded stone aggregate) in foundations, filling and mass-concrete etc., all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete 1:3:6 mix, type C2 (using 20 mm graded stone aggregate) as in retaining walls, any thickness, size or shape including pilasters, buttresses etc., complete all as specified and directed by Engineer-in-Charge. Note: Formwork shall be measured and paid seperately.
Use and removal of steel formwork to faces of walls, retaining walls, basement walls, ballast walls and the like vertical or batter for rough finished surfaces of concrete flat all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete Type B1, 1:2:4 mix (using 20 mm graded stone aggregate) as in bands, beams etc., all as specified and directed by Engineer-in-charge. Note: Formwork and reinforcement shall be measured and paid seperately.
Use and removal of steel formwork to sides and soffits of bands, beams and the like for rough finished surfaces of concrete all as specified and directed by Engineer-in-charge.
M&L for Mild steel deformed TMT bars 10mm dia and above as in reinforcement to concrete cut to length bent to shape required including cranking bending and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as directed by Engr-in-charge.
M&Lfor Mild steel deformed TMT bars 5mm dia and over up to and including 10 mm dia as in stirrups, spacers and binders , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified.
M&L for plain cement concrete 1:3:6 mix, type C1 (using 20 mm graded stone aggregate) as in coping, kneelers, apex stones, bed plates, water trough and like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm dia PVC(SWR) pipe(4.50 KGF) for weep holes complete all as specified and directed by Engineer-in-Charge. Make: PRINCE/ SUDHAKAR/ NANDI/ FINOLEX/ SWASTIK
M&L for Hand packing (any thickness) 80 to 150mm gauge Broken stone or boulders at back of walls complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, laying of pipe, cable etc., or for shafts, wells, cesspits, manholes, pier holes, etc., not exceeding 10 sqm on plan and getting out in soft/loose soil all as specified and directed by Engineer-in-charge.
M&L for reinforced cement concrete 1:1½:3 mix, type A1 (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams etc., all as specified and directed by Engineer-in-Charge. Note: Formwork and reinforcement shall be measured and paid seperately.
M&L for reinforced cement concrete 1:1½:3 mix, type A1 (using 20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts etc., all as specified and directed by Engineer-in-Charge. Note: Formwork and reinforcement shall be measured and paid seperately.
M&L for reinforced cement concrete 1:1½:3 mix, type A1 (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels exceeding 1.5 m span, bands etc., all as specified and directed by Engineer-in-Charge. Note: Formwork and reinforcement shall be measured and paid seperately.
M&L for reinforced cement concrete 1:1½:3 mix, type A1 (using 20 mm graded stone aggregate) as in slabs supported on walls, colums, beams, etc., complete all as specified and directed by Engineer-in-Charge. Note: Formwork and reinforcement shall be measured and paid seperately.
Use and removal of steel formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete flat all as specified and directed by Engineer-in-Charge.
Use and removal of steel formwork to sides of square, rectangular or polygonal pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete all as specified and directed by Engineer-in-Charge.
Use and removal of steel formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., for rough finished surfaces of concrete flat all as specified and directed by Engineer-in-Charge.
Use and removal of steel formwork to soffits of slabs etc., not exceeding 200mm thick for rough finished surfaces of concrete flat all as specified and directed by Engineer-in-Charge.
Use and removal of steel formwork to edges of concrete slabs etc., exceeding 10 cm and not exceeding 20 cm wide for rough finished surfaces of concrete flat all as specified and directed by Engineer-in-Charge.
M&L for Mild steel deformed TMT bars 8mm dia as in reinforcement to concrete cut to length bent to shape required including cranking bending and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as directed by Engr-in-charge.
M&L for factory made precast cement block masonry with solid blocks made of Plain cement concrete 1:3:6 mix type C1 (using 20 mm graded stone aggregate) exceeding 10cm width and setting in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge. Make : Shankar Saw Mills/Sangam Prefeb Products or equivalent make as approved by GE.
M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for rendering 15 mm thick on brickwork or concrete surfaces in cement mortar 1:4 finished fair and even including waterproofing compound @ 3% by weight of cement as per manufacturer's instructions complete all as specified and directed by Engr-in-charge.
M&L for rendering 5 mm thick on concrete surfaces in ceilings in cement mortar 1:3 finished fair and even complete all as specified and directed by Engr-in-charge.
M&L for rendering 10 mm thick on concrete surfaces on roof as roof treatment in cement mortar 1:3 finished fair and even including waterproofing compound @ 3% by weight of cement as per manufacturer's instructions complete all as specified and directed by Engr-in-charge.
M&L for preparing newly plastered surfaces of walls and applying two coats of premium Exterior emulsion paint over one coat of primer complete all as specified and directed by Engineer-in-Charge. Make: APEX of ASIAN or equivalent in JENSON & NICHOLSON/ BERGER/ SHALIMAR
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of primer complete all as specified and as directed by Engineer-in-Charge. Make: ASIAN/SHALIMAR/BERGER/ JENSON & NICHOLSON
M&L for preparation of new plastered surfaces of ceilings and applying two coats of distemper oil emulsion over one coat of alkali resistant primer complete all as specified and as directed by Engineer-in-Charge. Make: ASIAN/SHALIMAR/BERGER/ JENSON & NICHOLSON
M&L for Complete removal of the existing treatment on walls by scraping and washing down with water including making good the surfaces, from surfaces of walls and applying two coats of distemper oil emulsion over one coat of primer over thin layer of wall care putty (Birla white/Berger/Asian) complete all as specified and as directed by Engineer-in-Charge. Make: ASIAN/SHALIMAR/BERGER/ JENSON & NICHOLSON/IEL
S&F Powder coated aluminium frame for partitions, doors, windows ventilators with one or more rebates, grills including joining cleat for fixing etc., complete all as specified and dierected by Engr-in-Charge.
S&F powder coated aluminium window and ventilator glazed shutters fixed type without sash bars, with standard aluminium sections for shutter top & sides, shutter bottom, shutter interlock of weight 0.55 Kg/m including necessary jointing cleats, glazing clips, rubber packing, screws, etc. as per manufacturer's instructions complete all as specified and directed.
S&F powder coated aluminium window and ventilator glazed shutters sliding type without sash bars, with standard aluminium sections for shutter top & sides, shutter bottom, shutter interlock of weight 0.55 Kg/m including necessary jointing cleats, glazing clips, rubber packing, rollers, locking plates, screws, etc., as per manufacturer's instructions complete all as specified and directed.
S&F powder coated aluminium door shutters, aluminium section weighing not less than 0.55kg/m including necessary joining cleats, glazing clips, rubber/neoprene packing, handles 2 No's in each door, hinges,etc., as per manufacturer's instructions complete all as specified and directed. Make for Item No. 33 to 36: JINDAL/INDALCO/HINDALCO
S & F 4.8mm thick sheet glass frosted on one side ordinary quality and fixed in aluminium fames area exceeding 0.5Sqm in each pane complete all as directed by Engr-in-Charge. Make:- TRIVENI/ SAINT GOBAIN/ MODIGUARD/ATUL/ HINDUSTAN or equivalent as approved by GE.
Removing surplus excavated soil to a distance not exceeing 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
S&F Fe 410-W (Gde-E- 250) quality-A Rolled steel sections, as in framing for cladding, glazing and the like including distance pieces, cleats etc., complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new or previously un treated surfaces of steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed. Make: ASIAN/ SHALIMAR/ BERGER/ JENSON&NICHOLSON/IEL/NEROLAC/IEL
M&L for Hardcore with Broken stone/boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface all as specified and directed by Engineer-in-charge.
M&L for 75 mm thick Plain Cement Concrete 1:3:6, type C2 (using 40mm graded stone aggregate) as in sub base and finishing even and rough to receive toping layer complete all as specified and directed by Engineer-in-charge.
Demolition of reinforced cement concrete in roofs, floors, beams, staircases, landing, chajjas and similar work including cutting reinforement and removing rubbish off the premises complete all as specified and directed by Engineer-in-charge.
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit, medium grade of suitable size with all necessary fittings, fixed on surface of walls/ceilings etc., including 1.5 Sq mm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and including modular type terminal boxes with inner and outer cover concealed type for mounting fittings like modular switch, socket, fan regulator etc., for one light /fan point controlled by one switch/one bell / buzzer point controlled by one bell push/one 3 / 5 -pin switch socket outlet 5 amps on independent board including testing on completion complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 2.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit, medium grade of suitable size with all necessary fittings, fitted on walls/ceilings etc., including 2.5 Sqmm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and including modular type terminal boxes with inner and outer cover concealed type for mounting fittings like modular switch, socket, fan regulator etc., for one 5 / 6 -pin switch socket outlet 15 amps on independent board including testing on completion complete all as specified and directed by Engineer-in-Charge. Make for Item No. 44&45 Cable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor Conduit: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza
Supply and fixing modular switch one way 6 Amps, 1 module complete all as directed by Engr-in-charge.
Supply and fixing modular switch one way 16 Amps, 1 module complete all as directed by Engr-in-charge.
Supply & fixing modular socket, 6A-2/3 pin combined 2 module complete all as directed by Engr-in-charge.
Supply and fixing modular socket 6/16A, 6 pin, 2 module complete all as directed by Engr-in-charge. Make for Item No 46 to 49: - MK/ANCHOR ROMA/CRABTREE/ NORTH WEST/LEGRAND/HAVELLS
S&F Energy efficient LED Tube light fitting, 1x18 watt, with LED tube rod 18/20 Watt with bipin holders, connector block etc., complete with all accessories internally prewired and including connecting up with three core pvc sheathed flexible copper conductor cable of size 1 sqmm complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No. DMLN1LT8-16 (Batten), MAS LED TUBE 18 W/1800 LM 865 T8, HSN Code-85395000 (Tube rod) of Phillips or equivalent madel of Havells/Crompton.
S&F decorative wall mounting, SS finish fixture with opel glass diffuser suitable for 40 W incandiscent candle lamp in cluding lamp complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No. LHJE02106499 of Havells or equivalent madel of Phillips/Crompton.
S&F sheet metal enclosure DB SPN 4 way 240 V with 200 Amp rated bus bar, powder coated, double door all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SPN 40 Amps, 10 KA breaking capacity, 240 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SP 6 to 32 Amps, 10 KA breaking capacity, 240 volts, 50 Hz complete all as specified and as directed by Engineer-in-Charge. Make for Item No. 52 to 54: Legrand/Siemens/Schneider
M&L for sub main wiring complete with 2 runs of 6 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawing through and including rigid PVC conduit of 25 dia fixed on wall/ceiling and connecting terminal ends including provision of 1 run of 6 Sqmm insulated multistranded copper cable as earth continuity conductor and connecting to earth dolly complete all as directed by Engr-in-charge. Note: 2 runs of 6 Sqmm and one run of 6 Sqmm and one run of conduit pipe shall be measured as one unit length. Make Cable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor Conduit: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza
S&F ceiling rose 3 terminal PVC/Polycarnonate, isolated body complete all as specified and as directed by Engineer-in-Charge. Make: (i) Anchor (ii) Plaza, (iii) Havells (Crabtree) (iv) ABB (v) Shalabh
M&L for boulders of size exceeding 15cm and upto 30cm vertical bunds filling dry, hand packed tightly complete all as specified and as directed by Engineer-in-Charge.
SANJAY SAW MILL
MS BRAHMA CONSTRUCTION
RAMESH GURUNG
RAJU TAMANG
G K SUTHAR
PRASAD PRADHAN AND SON
ANTHONY PRADHAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .