Loading…
Loading…
Tender Value
₹46.3 L
EMD Value
₹92,600
Closing Date
31 Aug 2026, 3:00 pm7d left
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER ELG
14 conditions · 5 needing a document upload
The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
Scanned copy of valid GST (Goods & Service Tax)Registration Certificate.
The following documents should be attached with the tender ( Annexure-V (A) certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. & Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder
Partnership deeds, power of Attorney etc. (if any) : The tender shall clearly specify whether the tender is submitted on his own or on behalf of a partnership concern. If the tender is submitted on behalf of partnership concern he should submit the certified copy of the partnership deed along with the tender authorisation to sign the documents on behalf of the partnership firm. If these documents are not enclosed along with the tender document, the tender will be treated as hearing lease submitted by the individual signing the tender documents. The Railway will not consider any power of Attorney granted by the tender or any changes in the composition of the firm made subsequent to the execution of the contract. It may however recognize such power of Attorney and change after obtaining proper legal advice, the cost of which will be chargeable to the contract.(Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder. As per clause no. 14(e) of GCC'22, the following documents to be uploaded in terms of Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.
Option for receiving payment through Letter of Credit . (Please attach scannedcopy of ANNEXURE 1 LC & ANNEXURE 2 LC duly filled up by the firm if optedfor)
The following documents should be attached with the tender: (i)Scanned copy of Pan Card. (ii)Scanned Copy of EFTMANDATE FORM Duly filled up by the bidder(iii)Tender Document (duly digitally signed by the bidder)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Scanned copy of valid Trade license or Propitorship Certificate.
Railway Officers Associated with tenderer:RAILWAY OFFICERS ASSOCIATED WITH TENDERER 1. ExRailway Officer as tenderer: Should tenderer be a retired Gazetted Officer working before his retirement on any of the Railways owned and administered by the President of India, or should the tenderer being partnership firm have as one of its partners a retired Gazetted Officer as aforesaid, or should the tenderer being an incorporated company have any such retired Officer as one of its Directors, or should the tenderer have in his employment any retired Gazetted Officer as aforesaid, full information of such person shall be submitted along with his tender in the format given in annexure-VI to this chapter of this tender document. (Authority: ACS No.3 to GCC July,2014vide Boards letter No.2014/CEI/CT/O/9/RET dt.22.01.2015)(please attach scanned copy of Annexure-VI duly filled up by the firm).
List of the Works completed in the last three financial years giving description of work. Organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and date of payment and final value of contract should also be given. (Supportive documents/ certificates from the organization with whom worked/are working should be enclosed) (Please attach scanned copy of Annexure-I duly filled up).
List of works in hand indicating Supportive documents/certificates from the organization with whom worked/are working should be enclosed) description of work, contract value, approximate value of balance work yet to be done and date of award. (Supportive documents/certificates form the organization with whom worked/are working should be enclosed).(Please attach scanned copy of Annexure-IV duly filled up)
The Contractor/(firm) must go through the entire tender document along with all attachment for any kind of guidance regarding execution of the job & payment there after. In case any thing is left out or not clear then they should consult the General Condition of Contract & standard Specification as attached (uploaded ).The bidders are also advised to preserve a copy of entire tender document/ (Set) for their convenience.
1) Eleiectrical (General) work in connection with Construction of new LHS in lieu of LC Gate No. 17/A/6 by Railway's relieving girder under AEN/NDAE. 2)Electrical (General) work in connection with Construction of new LHS in lieu of LC Gate No. 17/A/1 by Railway's relieving girder under AEN/NDAE. 3) Electrical (General) work in connection with Construction of new LHS in lieu of LC Gate No. 18 by Railway's relieving girder under AEN/NDAE. 4)Electrical (General) work in connection with Construction of new LHS in lieu of LC Gate No. 21/1/C/E (ML) by Railway's relieving girder under AEN/KWAE. 5)Electrical (General) work in connection with Construction of new LHS in lieu of LC Gate No. 26/1/1 (E) by Railway's relieving girder under AEN/AZ.
EL-HWH-25-21-3668~ER
EL-HWH-25-21-3668
Open
Works - General
180 Days
Howrah, West Bengal
₹0
₹92,600
10 Aug 2026
10 Aug 2026
17 Aug 2026
318 items across 6 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 7,84,419 | ||
| — | — | — | 24,800 | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos.single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phaseand neutral in GI conduit of suitable dia along with 1 no. singlecore HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ).( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / V-MARC ) | — | 200.00 | — | — | |
| — | — | — | 58,000 | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. singlecore HRFR / FRLS grade, PVC insulated, copper conductor cableof size 2.5 sq.mm, 1100V grade for phase and neutral in GIconduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ).( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / V-MARC ) | — | 400.00 | — | — | |
| — | — | — | 75,000 | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 4 nos. singlecore HRFR / FRLS grade, PVC insulated, copper conductor cableof size 4.0 sq.mm, 1100V grade for three phases and one neutralin GI conduit of 25mm dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ).( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / V-MARC ) | — | 150.00 | — | — | |
| — | — | — | 3,40,640 | ||
| Supply of Submersible Sewage Pump-Motor set of discharge capacity 92 Cubic metre per hour and discahrge head 9 Mtrs. (approx.) suitable for operation on 415V, 50 Hz, 3Ph / 240V,50 Hz, 1 Ph supply system complete with one fully automaticstarter control panel with all protection and float switch alongwith 10 Mtrs. long multicore copper flexible cable of suitable size for motor operation, 5 mtr. Lifting Iron Chain, GI clamps, steelwire rope with double pulley, PVC flexible pipe of suitable sizeand length including installation and commissioning.( Make of pump-motor set - KSB / Texmo / CRI / Kirloskar / Crompton / Calama )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / V-MARC ) | — | 2.00 | — | — | |
| — | — | — | 60,800 | ||
| Trenching and laying of cable under ground by soil cutting with covering of cable by sand and bricks / through suitabledia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN-10 or higher) without bricks alongwith refiling of trench by excavated soil and make good of surface as its original condition. ( Cable will be supplied by Railway ) | — | 400.00 | — | — | |
| — | — | — | 5,950 | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable alongwith makegood of floor surface as its original condition after laying of cable( Cable will be supplied by Railway ) | — | 70.00 | — | — | |
| — | — | — | 14,060 | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable through 80mm dia GI pipe including supply of GI pipe alongwith make goodof floor surface as its original condition after laying of cable( Cable will be supplied by Railway ) | — | 20.00 | — | — | |
| — | — | — | 16,000 | ||
| Drawing of cable on wall / structure with suitable size and shapeGI clamps including supply of suitable size GI Clamp and GI nut-bolts and commissioning of cable( Cable will be supplied by Railway ) | — | 400.00 | — | — | |
| — | — | — | 2,595 | ||
| Drawing of cable through one no. 2" dia, 3.0 Mtrs. longGI pipe ( Make - Tata / Jindal / Bansal ) for protectionof cable on pole with proper GI clamps and GI nuts & boltsincluding supply of GI pipe( Cable will be supplied by Railway ) | — | 3.00 | — | — | |
| — | — | — | 27,624 | ||
| Supply of GI ( minimum coating thickness 65 microns ) conical / octagonal ( minimum sheet thickness - 3mm ) Pole of overall length 5 M with single / double arm bracket, top cover, base plate including hinged door-inbuilt Junction box complete with copper bar, insulator, Hylam sheet for cable termination and fuse kit-kat / MCB ( Make - Utkarsh / B.P. Projects / Crompton / Bajaj / Surya ) | — | 4.00 | — | — | |
| — | — | — | 12,464 | ||
| RCC foundation, erection and commissioning of above GI polewith construction of cement concrete muffing ( Cement : Stone :Sand = 1 : 2 : 4 ) with foundation accessories including earthingof pole with 1 no. of 50 mm dia, 3 M long GI pipe ( Make - TATA / Jindal / Bansal ) with necessary earth connection frompipe to pole by GI Strip / GI wire | — | 4.00 | — | — | |
| — | — | — | 1,432 | ||
| Wiring of light point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral through pole from inbuilt poleJunction Box's porcelain fuse kit-kat / MCB to light fitting alongwith 1 no. single core HRFR / FRLS grade, PVC insulated copper conductor cable of size 1.5 sq.mm, 1100V grade forEarth Continuity Conductor ( ECC ).( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / V-MARC ) | — | 8.00 | — | — | |
| — | — | — | 672 | ||
| Dismantling / Cutting of existing pole and make goodof surface including transportation from site to stores | — | 2.00 | — | — | |
| — | — | — | 2,336 | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos.single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phaseand neutral in PVC conduit / casing along with 1 no. singlecore HRFR / FRLS grade, PVC insulated, copper conductorcable of size 1.5 sq.mm, 1100V grade for Earth ContinuityConductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / V-MARC ) | — | 8.00 | — | — | |
| — | — | — | 326 | ||
| Wiring of 6A / 3 pin Plug board consisting with one plug socketand one 6A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated,copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / V-MARC ) | — | 2.00 | — | — | |
| — | — | — | 3,400 | ||
| Wiring of Submain by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated,copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab / V-MARC ) | — | 50.00 | — | — | |
| — | — | — | 610 | ||
| Extra cost for conceal wiring in respect to PVC conduit / casingfor light, fan, plug, power plug, multi-plug point etc. includingmake good of wall surface as its original condition | — | 10.00 | — | — | |
| — | — | — | 950 | ||
| Extra cost for conceal wiring for main / submain with respect to PVC conduit / casing including make good of wall surface as its original condition | — | 50.00 | — | — | |
| — | — | — | 1,176 | ||
| Extra cost involvement for modular switch, bell push, plug socket,fan regulator, USB point, TV socket etc. with other accessories( Make of Modular switch, socket, box, cover plate etc. - ABB /Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 12.00 | — | — | |
| — | — | — | 4,736 | ||
| Fixing, connection, testing and commissioning of indoor LEDluminaire fittings with suitable arrangement.( LED indoor light fitting will be supplied by Railway ) | — | 64.00 | — | — | |
| — | — | — | 468 | ||
| Fixing, connection and commissioning of Street Light luminaire with suitable dia heavy gauge GI bend pipe with GI clamps madeof GI flat of size 40mm x 6mm and GI nut-bolts on structure / wall( LED Street light fitting will be supplied by Railway ) | — | 2.00 | — | — | |
| — | — | — | 1,432 | ||
| Fixing, connection and commissioning of out doorLED Flood light / Street Light fitting on High Mast Tower / Pole / Structure with suitable arrangement.( LED outdoor light fitting will be supplied by Railway ) | — | 8.00 | — | — | |
| — | — | — | 73 | ||
| Installation, connection and commissioning of Wall Bracket fan with GI clamps made of GI flat of suitable size and GI nut-bolts on wall / structure.( Wall Bracket Fan will be supplied by Railway ) | — | 1.00 | — | — | |
| — | — | — | 15,132 | ||
| Supply of SPN DB ( Metal Enclosure with Metal Door ), 8 way, 50Hz, complete with 4 nos. SP MCB of current rating from6A to 32A, 10kA, 240V, 50Hz as per requirement of load and1 no. DP RCBO of current rating 40A, 300mA, 10kA, 230V,50Hz ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells ) | — | 3.00 | — | — | |
| — | — | — | 363 | ||
| Fixing, connection and commissioning of above SPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement. | — | 3.00 | — | — | |
| — | — | — | 5,925 | ||
| Supply of MCCB with Thermal - Magnetic Release of breakingcapacity 36 kA at 415V AC, 50Hz of capacity 25-32A / 32-40A / 40-50A, 4 Pole complete with metal enclosure with spreader terminals including fixing, connection, testing and commissioning.( Make - L&T /Siemens / ABB / Hager / Legrand /Schneider / C&S ) | — | 1.00 | — | — | |
| — | — | — | 4,900 | ||
| Supply of Sheet Moulded Compound ( SMC ) JB box, fireretardant of size 250 x 250 x 155 mm ( IP-55 ) / equivalentsize heavy duty, outdoor type, UV ray protected, self fire-extinguishing, shock resistance IK08 or above and IP65 degree of protection grade transparent polycarbonate DB box including fitment with suitable size and shape Mild Steel( MS ) bracket by replacing existing damage box and accessories with testing and commissioning.( Make : Hensel / Sintex / OBO Bettermann / RMC / Grasp / ABB / Legrand / Spelsberg / EPP Composites ) | — | 2.00 | — | — | |
| — | — | — | 15,382 | ||
| Supply of Dust and vermin proof metal Busbar Chamber made of 16 SWG ( 1.6mm ) MS sheet duly powder coated consisting of 4 nos. tinned copper busbar of each bar ofcapacity 100 Amp, 4 way, suitable for 415V, 50Hz supplysystem including all accessories alongwith fixing, connection, testing and commissioning of incoming and outgoing cablesglanding, cable socketing and connection with all suitable arrangement.( Make - Havells / Standard / HPL / C&S / LK (L&T) / Indoasian ) | — | 2.00 | — | — | |
| — | — | — | 78,235 | ||
| Supply of LT cubicle type indoor wall / floor mounted Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following :a) MCCB with Microprocessor Release of breaking capacity36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication suitable for Release Range ( 25-63 ) Amp, 4 Pole - 1 no.b) MCB, 4 Pole, 32Amp, 415V, 50Hz, 10kA ( C-curve ) - 2 nos.c) MCB, 2 Pole, 10Amp, 240V, 50Hz, 10kA ( C-curve ) - 2 nos.d) Power Contactor, 3 Pole, 12A, 415V, 50Hz - 2 nos.e) Astronomical Timer Switch - 2 nos.f) Tinned Copper Busbar ( 4 Bar ) each of capacity 100 Amps., 415V, 50 Hz - 1 setg) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 1 no.h) CT of suitable ratio for MFM - 3 nos.i) LED indication lamp for Phases and "ON & OFF" indication for operating status of breakers - 6 nos.complete with all other accessories, internal wiring by single coreFRLS grade copper conductor cable of suitable size and 1100V grade along with fabrication work, cable glanding, socketing etc.( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Energy Meter - ABB / Schneider / Secure / Legrand / LK (L&T) / Genus / Conzerv /Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) | — | 1.00 | — | — | |
| — | 1.00 | — | — | ||
| — | 2.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderBooklet.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
TenderFormandAnnexuresnew.pdf Tender form and annexure
ATTACHMENT
HTLTstandardspecification.pdf
ATTACHMENT
TENDERCLAUSE-3668.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
Advancecorrectionslipsupto11.pdf Advance Correction Slip
ATTACHMENT
TenderFormandAnnexuresnew.pdf
ATTACHMENT
Advancecorrectionslipsupto11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].