Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 CrAccepted-AOC 15 16 GANGA COLONY KHATIPURA ROAD JAIPUR RAJ 302012 | JAIPUR | JAIPUR | RAJASTHAN | 302012 | ₹14.9 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹15.4 CrRejected-Finance | ₹15.4 Cr | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹15.9 CrRejected-Finance NOT SPECIFIED | ₹15.9 Cr | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹16.0 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹16.0 Cr | L4 | Rejected-Finance Not Lowest |
Tender Value
₹11.0 Cr
EMD Value
₹8.8 L
Closing Date
17 Feb 2022, 6:00 pmClosed
CE (AF) Gandhinagar
HQ CE (AF) Gandhinagar Lekawada Patia Chiloda PO CRPF Campus Gandhinagar-382042
Demolition and reconstruction of certain SMQs at Air Force Station Jaipur
2021_MES_483531_2
80303/E8
Open Tender
Civil Works
720 days
AGE (I) (AF) Jaipur
As per NIT and Tender Documents
8 documents required · 8 mandatory
₹3,000
Yes
AGE (I) (AF) Jaipur
₹8.8 L
Yes
28 Apr 2022
13 Jan 2022
19 Feb 2022
13 Jan 2022
17 Feb 2022
5 Feb 2022
15 Jan 2022 - 3 Feb 2022
Amount
NOTE: Schedule ‘A’ Part I to XIV are under Ser No. 2.00 to 15.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.
Lump sum price worked out for Excavation & Earthwork as listed in Sch `A’ Part II
Lump sum price worked out for Internal Water Supply as listed in Sch `A’ Part III
Lump sum price worked out for Internal Electrification as listed in Sch `A’ Part IV
Lump sum price worked out for Demolition as listed in Sch `A’ Part V
Lump sum price worked out for Road/Path/Hardstanding as listed in Sch `A’ Part VI
Lump sum price worked out for Sewage Disposal as listed in Sch `A’ Part VII
Lump sum price worked out for Area Drainage as listed in Sch `A’ Part VIII
Lump sum price worked out for External Water Supply as listed in Sch `A’ Part IX
Lump sum price worked out for Lightening Arrestor as listed in Sch `A’ Part X
Lump sum price worked out for External Electrification as listed in Sch `A’ Part XI
Lump sum price worked out for Fire Fighting as listed in Sch `A’ Part XII
Lump sum price worked out for Lift as listed in Sch `A’ Part XIII
Lump sum price worked out for Standby Power Supply as listed in Sch `A’ Part XIV
SCHEDULE `A' PART - XV Fittings & fixtures is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Supply, Installation, Testing and commissioning of silent type Diesel Engine driven generating set to give an output of 50 KVA capacity, 415 volts, 3 phase, 50 Hz, 4 cylinder and 4 stroke, 4 wire directly coupled to diesel engine, water cooled turbo charger after cooled type, mounted on common base plate complete with fuel tank of adequate capacity, viberation damper, other accessories with acoustic enclosure and altrnator connection with inbuilt AMF panel complete including PCC foundations as per OEM recommendation etc complete all as specified by the manufacture and as directed by the Engineer-In-Charge (Make - Sudhir (Cummins) ,Kirloskar ,Mahindra or equivalent (A) Diesel Driven Engine- Developing a net directed output 80 BHP or nearest higher suitable marked with alternator to give a net directed ouptut of 50 KVA. The engine shall be capable of delivering the required output at 1500 RPM at NTP, overload capacity for one hour in every 12 hours including comprising of following :- (i) Fly wheel to suit flexible coupling and fly wheel housing. (ii) Radiator assembly complete with fan water pump and thermostate. (iii) Fuel injection as manufacturer specifications. (iv) Electrical coil as per manufacturer instructions/design.
(v) Oil filter with mounting arrangements. (vi) Lubricating oil pump and cooler. (vii) Self starter 12 Volts. (viii) Exhaust silencer with including cladding with protection residential type exhaust noise level complying with CPCB norms. (ix) Dip stick to check oil level. (x) Suitable controller with start, stop, auto/manual reset button as per manufacturer instructions. (xi) Engine protection safety device for low lubricating oil pressure, high coolant temprature. (xii) Dynmo/alternator with over charging protection. (xiii) Batteries 12 Volts, 90 AH (Min) of suitable capacity as per manufacturer's design with lead etc of 01 nos maintenance free battery.
(B) Alternator :- The engine shall be coupled through flexible coupling to an synchromus alternator mounted on a strong steel/MS fabricated common base frame suitable for mounting on a permanent foundation. The alternator shall be 3 Phase, 50 Hz, 1500 RPM, self regulating and brushless type provided with suitable automatic voltage regulator and shall be confir to BS : 2613 or BS : 5000 and generating 50 KVA output after derating with coupled to diesel engine at 0.8 to 1 power factor lag, 415, 4 Wire, AC supply under NTP conditions. The alternator will confirm the following features :- (i) IP 23 protection with H class insulation. (ii) Permissible overload of 10% for one hour in 12 hour operation. (iii) Automatic voltage regulator (AVR) - Fast response electronic type.
(C) AMF PANEL :- Auto Maint Failure (AMF) control panel : microprocessor based design/ motorized operated 100 AMP auto changover switch and suitable contractor, made out of CRCA sheetor 3mm thick confirming to IS 8623 totally enclosed, dust and vermin proof with front and rear opening, 415 volts, 3 phase, 4 wire, AC 50 Hz having aluminium bus bar of capacity as required to carry current at 110% load of 50KVA DG set with manufacturer specification with following accessories :- (i) MCCB 4 pole 100 Amps adjustable type, 35 KA for DG. (ii) Combined digital type meter for AC/DC voltage/Amp/Frequency. (iii) Combined digital type meter for KW/power factor/KVA. (iv) Safety interlock : Mechanical and electrical interlocking for contractors. (v) Electronic KWH meter (Counter display) (vi) Inbuilt Battery Charger. (vii) Supply failure timer and restroration timer. (viii) 3 impulse automatic engine start/stop logic and engine fails to start lockout mains/senator voltage and freqency sensing.
(ix) Automatic manual switch. (x) Hooter (xi) Earth fault relay. (xii) SMPS based unit with inbuilt auto/manual and float/boost facility. Notes :- (i) The panel will be complete with internal wiring with suitable size of copper cable. (ii) The panel shall be duly tested and comply with CPRI test standard. (iii) AMF panel shall be placed on PCC/RCC platform as per CPCB of suitable size, height of platform from ground level 300mm and depth below GL as per OEM recommendations. Cost of PCC/RCC plateform is included in this items. (iv) Necessary grouting mild steel nuts, bolts, washers etc and anti vibration pad shall be provided by the contractor.
M&L for burnt brick sub class ‘B’ laid in trenches abutting each other with a gap not exceeding 10 mm , vertically over the cable for cable protection complete all as specified and as directed.
Cutting of (horizontally) existing road(max 10 m wide) suitable for GI tubing of 80 mm to 100 mm dia complete all as specified directed using trenchless technology.
Supply, install, testing and commissioning and testing factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK)outdoor type, platform mounted, including suitable angle iron (4 Nos leg) fixing on ground suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 600 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15 mm CRCA MS sheet 75mm x 30 mm thick MS Channel frame, duly powder coated finish. Front opening type with aprons for cable entry with double door shutter and locking arrangement, danger plate and earthing terminal and suitable PCC work and fix rubber mating of suitable size. The scope of work includes provision of the following :- Incoming (a) MCCB 4 pole 630 Amps, 50 KA, 415V -01 Nos, (b) Bus bar (copper strip) 1000 Amp, 4 pole, (c) digital panel meter (Amp,Voltage meter) including CTs -01 No. (d) Digital Indication Lamp Set-1
Supply, install, testing and commissioning and testing factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) outdoor type, platform mounted, including suitable angle iron (4 Nos leg) for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 215 amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, made of 2 mm CRCA MS sheet 75mm x 30 mm thick MS Channel frame, duly powder coated finish ,thimbling and cable entry boxes with cable gland incld painting with two coat of synethetic enamel paint over a coat of red oxide primer. Front opening type with aprons for cable entry with double door shutter and locking arrangement, danger plate and earthing terminal and suitable PCC work. The scope of work includes provision of the following :-
S&F Junction box made out of 2 mm thick CRCA sheet openable door duly painted, with suitable fixing arrangement consisting of 2 pole connector and 1 No MCB SPN of 6 Amp complete all as directed
S&F LED security light 60 watt 5700K,110 lumen per watt, made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, long life IP66 roadway luminaire and electronic driver including GI braket 0f 1.5 mtr long of suitable dia complete with nut bolt and washer, all as directed by Engineer-in Charge
S&F LED aviation obstraction light 30 watt heavy duty input voltage 150 to 300 volt single phase , made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, long life IP 65 luminaire and electronic driver red glass cover complete all as directed by Engineer-in Charge .
Cable jointing kit for 1.1 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 400 sqmm.
Cable jointing kit for 1.1 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 35 sqmm.
M&L for Air termination, 5 pointed, copper rod dia and 900 mm long with suitable fixing arrangement complete all as directed
Supply and fix Foot Valve conforming to IS 4038, 80 mm (3”) dia.
Supply and fix Strainer Y type conforming to IS, size80 mm (3”) dia.
S&F tee reducer of size 80 mm x 65/50 mm bore GI medium class.
S&F tee reducer of size 80 mm x 25 mm bore GI medium class.
S&F tee of size 80 mm x 80 mm X 63 mm bore GI medium class.
S&F tee equal of size 80 mm x 80 mm X 80 mm bore GI medium class.
S&F tee of size 100 mm x 100 mm X 80 mm bore GI medium class.
Supply, connect, lowering, testing and commissioning energy efficient Openwell Submersible pump set, electric driven 415V TP of capacity not less than 10 HP discharge 432-240 LPM at head 52-76 meter ,nearest higher with stainless steel body and SS empeler, diffuser & diffuser cassing complete connection with proper foundation , MS iron hook-02 Nos welded at the top of motor head suitable to tie SWR rope for anchoring purpose complete all as specified and directed at site by Engr-in-Charge. Make-Kirloskar KOS-1575+ or equivalent.
Supply connect, fix and test submersible cables copper conductor PVC insulated over all sheathed flat flexible ISI marked 1100 volts grade complete of size 10 sqmm, 3 core cable
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 80 mm .
Supply, install, commissioning and testing of Chemical dosing system suitable to inject solution minimum 25 LPH comprising dosing pump couple with electric motor of capacity 0.5 HP ,1440 RPM assemble with agitator dosing and agitator in single motor agitator with SS sweep blade duly FRP coated FRP tank 150 Ltrs capacity ,including PVC nylon flexible pipe suitable for chemical chlorine dosing of best quality of size 8 mm dia, complete unit mounted in heavy duty MS fabricated frame of size 40X40X6 mm duly anti corrosive paint complete and testing complete with connection with main pipe line for feeding chlorination with stop cock including chemical grade PVC NRV complete all as specified and as directed by Engr-in-Charge.
M & L for low smoke zero halogen (LS0H) fire survival control cable with circuit integrity, conforming to BS 7846 and rated for 600 V, having plain annealed stranded copper conductor with fire-resistant mica tapes covered by an extruded layer of cross-linked polyethylene, extruded layer of thermoplastic low smoke zero halogen (LS0H) compound, single layer of galvanized steel wires and thermoplastic LS0H compound sheath, suitable for operating temperature range -40 ˚C to +90 ˚C and minimum bending radius being 12 times the overall cable diameter, including laying, clamping, termination and ferruling complete all as specified and directed by the engineer-in-charge.
2 core, 2.5 mm² (for instrumentation)
3 core, 2.5 mm² (for auto start/stop panel)
12 core, 2.5 mm² (for diesel engine pump)
M & L for 1.1 kV grade copper conductor, XLPE insulated armoured cable conforming to IS 7098-1: 1988, having stranded aluminium compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete all as specified and directed by the engineer-in-charge.
3 core 35 mm² (for electric motor driven main fire pump)
3 core 6 mm² (for jockey pump)
M & L for PN 1.6 rated 200 mm NB polypropelene vortex inhibitor suction lift, conforming to BS 4504 with stainless wire mesh, bolts, nuts and washers, etc. complete all as specified and directed by the engineer-in-charge.
S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed by the engineer-in-charge.
S & F plug-in gas leak detector to provide an early warning for LPG or CNG / PNG gas leakage from cylinders or through pipelines calibrated to give an alarm at about 2000 ppm along with separate heat and gas sensors with LEDs, audible buzzer alarm, etc. complete all as specified and directed by the engineer-in-charge.
M & L for low smoke zero halogen (LS0H) flame retardant fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed by the engineer-in-charge.
2 core, 1.5 mm²
2 core, 2.5 mm² (supply to hooter/strobe)
S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. (1 No. at entry/exit of each floor)
S & F of 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge. (2 Nos. at entry / exit of each floor & 1 No. in lift machine room)
S & F of 9 litre mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge. (In Parking Area)
S & F 9 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. all as specified and directed by the engineer-in-charge. (In Parking Area)
S & F of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners complete all as specified and directed by the engineer-in-charge.
Sign of size 300 mm X 150 mm reading 'EXIT' in 12.5 mm block letters in Green and white background, properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level
Sign of size 150 mm X 600 mm, posted and maintained within each stair enclosure on every floor, indicating the 'Floor Number' in bold type and at 75 mm high numerals in red and white background, securely attached to the stair side of the door in a way that the bottom of the sign is not above 1.5 m from the finished floor level
Sign of size 450 MM X 150 MM reading 'FIRE POINT' in 12.5 mm block letters in White and Red background, properly spaced to provide good legibility located directly in corridor near to each Manual call point/Fire Extinguisher and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level
Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the 'LIFT / STAIRCASE' by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level
M & L for Construction of fly-ash brick masonry valve chamber of size 1000 mm X 800 mm X 1000 mm (internal dimensions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore , 200 mm thick fly-ash brick masonry walls built in CM 1:6, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/dense soil 6 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC cooping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of redoxide zincchrome primer including disposal of surplus soil to a distance not exceeding 50 m etc. complete complete as specified and directed by the engineer-in-charge
Taking down Bib tap/angle valve/ basin mixer/stop cock
Dismantling and taking down Electric water heater/Geyser of any wattage or size and deposited to MES store for reuse.
Taking down copper/aluminium circuit/sub main wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safecustody or for taking credit and making good disturbed surfaces of walls, floors, etc.
Dismantling and taking down Electric distribution board inclluding MCBs and Isolators of any type or size for repair or replacement of burnt/worn out accessories or carrying to MES store or laying properly for reuse or for sch of credit
Dismantling and taking down Electric Energy meter of any type or size for repair or replacement of burnt/worn out accessories or carrying to MES store or refixing.
Taking out/down u/s LT UG cable of 10 sqmm 2 core size from trenches/pipe/ducts/pole.
Taking out/down u/s LT UG cable of 25 sqmm 3.5 core size from trenches/pipe/ducts/pole.
Taking down & removing main LT Panel from main substation of 600 Amps bus bar including MCCB and other accessories and shifted to MES Yard.
Taking out/down u/s LT UG cable of 25 sqmm 3.5 core size from trenches/pipe/ducts/pole.
M & L for submain wiring with one run of three core PVC insulated and FR PVC sheathed copper cable of 10 Sqmm multi stranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC concealed conduits heavy duty grade ISI marked 25 mm dia (External) with wall thickness not less than 1.8 mm with conduit accessories complete all as specified and directed Note: one run of cable and 1 run of conduit shall be measured and paid as one meter length of unit.
M & L for submain wiring with one run of three core PVC insulated and FR PVC sheathed copper cable of 10 Sqmm multi stranded copper conductor FRLSH 1100 volts grade cable drawn through cable tray of suitable size including saddle/tightner and other fixtures required complete all as specified and directed. Note: cable tray will be measured and paid separately.
M & L for submain wiring with one run of three core PVC insulated and FR PVC sheathed copper cable of 06 Sqmm multi stranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC concealed conduits heavy duty grade ISI marked 25 mm dia (External) with wall thickness not less than 1.8 mm with conduit accessories complete all as specified and directed Note: one run of cable and 1 run of conduit shall be measured and paid as one meter length of unit.
M & L for submain wiring with one run of three core PVC insulated and FR PVC sheathed copper cable of 06 Sqmm multi stranded copper conductor FRLSH 1100 volts grade cable drawn through cable tray of suitable size including saddle/tightner and other fixtures required complete all as specified and directed. Note: cable tray will be measured and paid separately.
M & L for submain wiring with one run of three core PVC insulated and FR PVC sheathed copper cable of 04 Sqmm multi stranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC concealed conduits heavy duty grade ISI marked 25 mm dia (External) with wall thickness not less than 1.8 mm with conduit accessories complete all as specified and directed Note: one run of cable and 1 run of conduit shall be measured and paid as one meter length of unit.
M & L for submain wiring with one run of three core PVC insulated and FR PVC sheathed copper cable of 04 Sqmm multi stranded copper conductor FRLSH 1100 volts grade cable drawn through cable tray of suitable size including saddle/tightner and other fixtures required complete all as specified and directed. Note: cable tray will be measured and paid separately.
M & L for submain wiring with one run of three core PVC insulated and FR PVC sheathed copper cable of 2.5 Sqmm multi stranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC concealed conduits heavy duty grade ISI marked 25 mm dia (External) with wall thickness not less than 1.8 mm with conduit accessories complete all as specified and directed Note: one run of cable and 1 run of conduit shall be measured and paid as one meter length of unit.
M & L for submain wiring with one run of three core PVC insulated and FR PVC sheathed copper cable of 2.5 Sqmm multi stranded copper conductor FRLSH 1100 volts grade cable drawn through cable tray of suitable size including saddle/tightner and other fixtures required complete all as specified and directed. Note: cable tray will be measured and paid separately.
M & L for submain wiring with one run of three core PVC insulated and FR PVC sheathed copper cable of 1.5 Sqmm multi stranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC concealed conduits heavy duty grade ISI marked 25 mm dia (External) with wall thickness not less than 1.8 mm with conduit accessories complete all as specified and directed Note: one run of cable and 1 run of conduit shall be measured and paid as one meter length of unit.
M & L for powder coated perforated type GI cable tray 14 SWG thickness, height not less than 50 mm and width not less than 250 mm, along with cover of same width, tray joining accessories and clamps and fixtures etc. on OTS wall as mentioned in drawing complete as specified and directed.
M&L for TV socket along with non metallic rigid PVC heavy duty conduit concealed in wall (min 20mm dia (external)) from suitable entry point upto socket.
S & F chromium plated health faucet (ABS Body) with hand shower & flexible cord 15 mm dia with 1.25m long suitable for EWC including fixing to steel pipe or union complete all as specified and directed.
S & F 450mm long PVC connection with two Nos nuts internally threaded and PVC washer suitable for 15mm bore pipe line for hot & cold water complete all as specified and directed.
S & F paper holder chromium plated as approved quality complete all as specified and directed.
S & F soap dish made of stainless steel and chrome plated and all as specified and directed.
S & F brass CP two way 15mm bore screwed down screwed for iron pipe or for brass fernile complete all as specified and directed by Engineer-in-Charge
Removal of excavated material outside MD land and depositing complete at your own arrangment.
Supply, install, testing and commissioning and testing factory made and tested (including cpri type test certified) lt feeder pillar box (kiosk) indoor type, platform mounted, including suitable angle iron (4 nos leg) for 415 volts 3 phase 4 wire, 50 hz ac supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 300 amps rating installed on porcelain insulators. the panel shall be dust and vermin proof, made of 2.00 mm CRCA sheet 75mm x 30 mm thick ms channel frame, duly powder coated finish ,thimbling and cable entry boxes with cable gland incl painting with two coat of synesthetic enamel paint over a coat of red oxide primer. Front and back side opening type with aprons for cable entry with double door shutter and locking arrangement, danger plate and earthling terminal and suitable pcc work. the scope of work includes provision of the following :- Incoming (a) MCCB 4 pole 200 amps, 36 KA, 415V -01 No (from proposed commercial panel) (b) Bus Bar (Copper Strip) 300 Amp, 4 Pole (c) Digital Panel Meter (Amp, Voltage Meter) including CTS -01 No. (d) Digital indication lamp set-1 Outgoing (e) MCB SPN 40 Amp 230 V 50 HZ - 25 Nos ( G+11 Half portion 23 Nos Qtr) (f) MCB TPN 32 Amp , 415 V 50 HZ - 01 No (spare)
Provisioning of resources for maintenance and operation of lift 03 Nos (i.e. 13 passenger – 01 Nos and 08 passenger – 02 Nos) for G +11 Storey SMQs at 759 SU in three shift of 08 Hrs each /per day at AF Station Jaipur. Allied system & operation of lift directed by Engineer-in-Charge. The following staff shall be employed by the contractor for manning and operation of G + 11 storey at 759 SU (A) Lift Attendant : 03 Nos per day (i.e. 01 No per shift)
Sch of credit Rs 11,78,410.00
Agarwal Jagdish Construction Company Private Limited
United Sales Corporation
SOOD ASSOCIATES PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid