Assistant Engineer, Katwa Electrical Sub-Division
Katwa
Installation Of AC machines and allied EI work at different Ejlash and Office section at Katwa Sub Divisional Court, Purba Bardhaman----EI work at ACJM Court.
2026_WBPWD_5015354_1
WBPWD/AEKESD/NIT04/2025262nd Call
Open Tender
ELECTRICAL WORKS ORG
Percentage
Katwa
Please refer Tender documents.
5 documents required · 5 mandatory
₹6,170
15 Jul 2026
11 Jun 2026
8 Jul 2026
12 Jun 2026
6 Jul 2026
15 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and fixing 415V, 125A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. L&T / EIC approved. (4a/D-3) | 1 | Each | 7,637 | ₹7,637 |
| 2 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision
for earthing attachmen( 8 way Up to 160A) make- legrand (D-11/15) | 1 | Each | 10,306 | ₹10,306 |
| 3 | Supplying and fixing 415 V 125A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (D-8/10) | 1 | Each | 8,383 | ₹8,383 |
| 4 | Supplying and fixing double door Horizontal 4 way TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision
for earthing attachment make Legrand (D-10/14) | 4 | Each | 2,937 | ₹11,748 |
| 5 | Supplying and fixing 240/415 V FP 63A MCB Isolator on din rail of existing DBs and necessary connection. Make Legrand(D-5/6 | 4 | Each | 870 | ₹3,480 |
| 6Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection make Legrand (D-6/7) | |||||
| 6.01 | 6-32 A Sp MCB | 54 | Each | 165 | ₹8,910 |
| 6.02 | 63 A TP MCB | 5 | Each | 1,225 | ₹6,125 |
| 7Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Havells/Polycab/RR Kabel) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required (E9/1) | |||||
| 7.01 | 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC(From VTPN to HTPN) | 90 | RM | 819 | ₹73,710 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.37 MB
Tendernotice_2.pdf
PDF • 0.51 MB
BOQ_5084108.xls
BOQ • 0.39 MB
Extension02.pdf
PDF • 0.32 MB
Extension.pdf
PDF • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .