| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.3 LAccepted-AOC E 82 HQ CE A N Z PB POST BOX NO 687 LILLYPUR NEAR MES GURUDWARA HADDO POST SRI VIJAYA PURAM 744 102 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744102 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹47.9 L+₹4.5 L (10.3%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹48.8 L+₹5.4 L (12.4%)Rejected-Finance C O MR P YELUTWAD G NO 243 PLOT NO 24 SHIVSAI NAGAR NEAR HANUMAN TEMPLE TARODA BK NANDED MAHARASHTRA 431605 | NANDED | NANDED | MAHARASHTRA | 431605 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹49.1 L+₹5.7 L (13.1%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹49.3 L+₹5.9 L (13.6%)Rejected-Finance OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
31 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Haddo
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
EXTENSION OF BALCONY AT RHQ BUILDING AND CERTAIN WORKS UNDER GE HADDO
2021_MES_429571_1
8521/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
D a (i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹98,000
Yes
8 May 2021
10 Mar 2021
2 Apr 2021
10 Mar 2021
31 Mar 2021
19 Mar 2021
10 Mar 2021 - 16 Mar 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation etc., or for shafts, wells, cess pits, manholes, pier holes etc not exc. 10 Sqm on plan and n.exc. 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 Cum and getting out in hard/dense soil complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Removing of building material (concrete debris) to a distance upto 5.00km including loading, unloading and stacking at the destination
M&L for hardcore using broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
Supply only approved earth from outside MD land suitable for returning and forming, free from stone boulders of size 40mm and above
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base
M&L for Boulder filling dry, handpacked tightly, as in wire crate apron bunds complete all as specified
M&L for 200mm thick Boulder pitching with boulders of size 90mm to 150mm and grouted by CM 1:6, complete all as specified
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in post, boundary pillars etc., complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for 75mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C1 (using 20mm graded stone aggregate) as in copings, kneelers, apex stones, bed plates, kerbs, water troughs including weathering, slightly rounded or chamfered angles and throating including necessary form work, exposed surfaces of concrete finished even and smooth without using extra cement complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, cooking platforms and in shelves and the like complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to sides of sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete flat complete all as specified and as directed.
Demolition of PCC block masonry, built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removal of debris to outside MD land complete all as specified and as directed.
M&L for rendering 15mm thick in two coats 5mm thick in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement over 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed.
M&L for rendering 10mm thick in CM (1:4) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls of any description and applying two coats of distemper oil emulsion over a coat of primer after levelling the undulations if any with cement putty complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of external walls of any description and applying two coats of weather proof antifungal (exterior grade) acrylic emulsion over a coat of primer from the same manufacturer complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls with 3mm thick average wall care putty., and applying two coats of distemper oil emulsion over a coat of primer after levelling the undulations if any with cement putty complete all as specified and as directed.
M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment by scraping, washing, cleaning etc., and applying two coats of weather proof antifungal (exterior grade) acrylic emulsion over a coat of primer from the same manufacturer after filling the cracks with filler complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B0 (using 12.5mm graded stone aggregate) as in roof padding/sunken floors and similar work duly mixed with water proofing compound @ 3% by weight of cement complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
M&L for screed bed 12mm thick in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement on RCC roof surfaces, finished fair and even complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
M&L for preparing plastered surfaces and applying a coat of cold applied bituminous primer over cleaned roof/ sunken surface @ 0.30 Kg/sqm and applying one coat of hot blown bitumen 85/25 grade @ 1.2 Kg/Sqm over primer followed by 3 mm thick APP modified 5-layered polymeric water proofing membrane weighing not less than 3.0 Kg/sqm reinforced with polyester non-woven fabric weighing not less than 150 grams/sqm laid as per the manufacturer instructions with side over lap of 100mm & end over lap of 150mm & tucked into the chases on roof, sunken slabs, edges and vertical surfaces and finally finishing the APP membrane surface with bituminous aluminium paint @ 0.15 Kg/sqm complete all as specified and directed. MAKE: STP Limited/ PIDILITE INDUSTRIES LIMITED (Dr. FIXIT TORCHSHIELD P3160)/ IWL INDIA LTD
Supply only integral water proofing compound.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons, risers of steps, skirting, dado etc., laid bedded and pointed in any mortar mortar complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for glazed ceramic designed coloured tiles in vertical surfaces using size of tiles 300x450x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with colour of tile with and including 10mm thick backing coat in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for vitrified ceramic coloured tiles 9 to 10 mm thick (square/ rectangular) of approved shade, area of each tile exceeding 0.42 Sqm but not exceeding 1.00 Sqm as in floors etc., laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for vitrified ceramic coloured tiles 9 to 10 mm thick (square/ rectangular) of approved shade, area of each tile exceeding 0.42 Sqm but not exceeding 1.00 Sqm, for work on vertical surfaces such as skirting, dados and risers to steps etc., including 10mm thick backing coat in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for 16 to 18mm thick granite slab (of approved shade), machine cut, as in floors, vertical surfaces, steps (treads/risers) and the like laid over cement mortar (1:4) and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding, polishing and rounding (chamfering) the edges complete all as specified and directed.
M&L for glossy finished heavy duty chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block, glossy finished, any shape and size conforming to IS 15658-2006 of 80 mm thickness, M-40 grade, made of grey cement and pigments, any pattern, laid in floors, laid dry including filleting to edges in CM (1:4) complete all as specified and as directed.
M&L for sand (river sand) filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
Dismantling structural steel work as in frame work of any description complete all as specified and as directed.
M&L for mild steel joist, channel, angle or tee sections, fixed independently, without connecting plates, etc., (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe-410-W (Gde-E-250) Quality 'A' complete all as specified and as directed.
M&L for mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W (Gde E-250) Quality 'A' complete all as specified and as directed.
M&L for mild steel rolled sections as in posts built up of one beam or channel section with flange plates, caps, bases splices, angle brackets, cleats and other connections conforming to Fe 410 (Gde-E-250) quality 'A' complete all as specified and as directed.
M&L for mild steel galvanised PVC coated chain link fencing, 3.15mm nominal dia of GI wire, 1.4mm thick PVC coating and average area of aperture 0.25 Sqcm with weight of chain link not less than 2.0 Kg/Sqm complete all as specified and as directed.
M&L for mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc., conforming to Fe-410-W (Gde E-250) Quality 'A' complete all as specified and as directed.
M&L for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W (Gde-E-250) Quality 'A' complete all as specified and as directed.
Welding in repairs in mild steel exceeding 9mm but not exceeding 20mm thickness and length exc 2.5cm but not exc 5.0cm
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc., complete all as specified and as directed.
S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/valley gutters, fixed with self tapping screws including scaffolding for a height upto 12.0 metres complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
S&F aluminum flat iron wind ties of any size and thickness fixed with self tapping screws for fixing roofing sheets complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers.
Dismantling ceiling boards and wall cladding with complete structure (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
M&L for anodised aluminium snap grid frame work for false ceiling with size of grid 605mm x 605mm all as specified in SSR Part-I 2009, hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat iron 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including cutting, drilling, jointing etc., 6mm thick non-asbestos fibre cement building design boards fixed or laid/ inserted to aluminium frame work with screws complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area exceeding 1.5 Sqm but not exceeding 4.0 Sqm each complete all as specified and as directed.
M&L for powder coated anodised aluminium partition, window and door/ventilator with frame and shutters and grill fully or partly glazed, sliding/openable/fixed fully glazed and panels fixed with panels inserts 12 mm thick pre-laminated particle board/sheet glass including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts etc. The size of aluminium section shall be all as specified in relevant IS Code and SSR Part-I complete all as specified and as directed. NOTES: (i) Supply only floor spring, glass, Imax hinges, SS friction hinges, particle board, aluminium fly proof mesh will be measured and paid separately under relevant items of this BOQ. (ii) Weight of aluminium section only shall be accounted for the purpose of payment. However unit rate quoted shall be deemed to include for cost of rubber beading, neoprene packing, fittings such as handles, butt hinges, tower bolts, rollers for sliding windows, locking arrangement and fixing only of panel inserts of glass/ particle board/aluminium fly proof mesh etc. (iii) Weight of aluminium handle, butt hinges, tower bolts shall not be accounted for payment purpose.
SUPPLY ONLY 5.0 mm thick sheet glass, ordinary quality and glazing with aluminium glazing clips in square not exceeding 0.5 Sqm in each pane with Solar control film 25 micron reflective type (Garware sun control or equivalent) complete all as specified and as directed.
SUPPLY ONLY 4.0 mm thick sheet glass, ordinary quality and glazing with aluminium glazing clips in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only aluminium expanded metal fly proof mesh, cut to required size and shape, with 0.45mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.
S&F anodised aluminium grill of approved pattern, anodised powder coated, cut to required size and shape, fixed in position with aluminium beading & frame made of aluminium F-section fixed to aluminium windows/ventilators complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes as in weep holes of retaining wall complete all as specified and as directed.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints, laid in trenches/fixed to walls/placed in weep holes using synthetic rubber adhesive cement solvent complete all as specified and as directed.
S&F PVC (SWR) bends any radius, diameter of outlet 75 mm complete all as specified and as directed.
S&F PVC (SWR) multi floor trap with grating including jointing with solvent cement, diameter of outlet 75 mm complete all as specified and as directed.
S&F 15mm bore unplasticised PVC pipes of pressure rating 10 Kgf/cm² including fittings, fixed complete to walls, ceilings or in floors etc., (including concealing, if required) and to any type of pipe complete all as specified and as directed.
S&F PVC Perforated pipe 110mm dia medium grade for laying in trenches after covering with clothing or geo textile cloth as per specified and as directed by engineer in charge.
S&F Non woven Geo textile having thickness of 400 gsm, having minimum tear strength of 250 ASTM D4533, width wise atleast 215 ASTM D4533 having puncture strength of 1550 pulse as per ASTM D6241 having elongation at break % of 57 pulse as per ASTM D4595 in two layers, made out of long fibres to hold the modules and protect liner including cutting, sizing, head welding and needle punched for high porosity and proper percolation complete all as specified and as directed. Make : Ashwath or equivalent
S&F bib tap, brass, 15mm dia, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule, fixed in repairs complete all as specified and as directed. MAKE: JAQUAR Cat part No. FLR-5047N)
S&F kitchen sink with drainage board made of stainless steel 1mm thick with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, fixed in repairs complete all as specified and as directed.
Drilling holes with drilling machine for bolts, gas pipes, etc., not exceeding 25mm dia, each hole of 10cm depth complete all as specified and as directed.
M&L for designer multi stepped suspended false ceiling with and including 12.5mm thick gypsum board, consisting of intermediate channel of 45x15x0.9mm thick for ceiling (frame work shall be suspended from soffits of roof with raw plugs) finally joints shall be filled with jointing compound and paper tape and surface finished smooth including applying two coats of acrylic distemper over one coat of primers after finished 3mm thick wall care putty grinding with sanding paper.
S&F designer POP cornice of desired colour with cross section not exceeding 1800 Sqmm and finishing of connected wall surfaces (300mm both side) to match with existing wall finish.
S&F 12mm thick toughened glass in required size duly crystal polished at the edges and with full etched design finalized by GE in different colours fixed with stainless steel brackets of size 50x25mm, 100mm long made out with 3mm thick SS sheet at the top and bottom, Dorma X:C fittings & Dorma floor springs or ss pivot ,stainless steel handles 600mm D type and locking arrangement to each door, stainless hinges to connect glass to glass, wall to glass connector, magnetic seal, middle seal and the water dispenser etc all as directed
S&F 12mm thick toughened glass in required size duly crystal polished at the edges and with full etched design finalised by GE in different colours fixed with stainless steel brackets of size 50x25mm, 100mm long made out with 3mm thick SS sheet at the top and bottom, stainless hinges& brackets to connecting to SS railings glass to glass, wall to glass connector, magnetic seal, middle seal etc all as directed.
M&L for stainless steel hollow sections circular/square/rectangular in shape and any size and thickness, grade AISI-316 type (Austenitic anti-corrosive in nature) as in railings/grills/designer work including post top cap, bottom plate, cutting, bending, seamless welding and fixed in any location complete all as specified and as directed.
S&F 3mm thick aluminium composite panel (ACP) on stainless steel grid frame work made up of composite sections/panels using stainless steel rivets of suitable size by necessary drilling of holes at suitable spacing as per manufacturers instructions including filling up joints with silicon sealants etc., length of sheets as customised at site of work and shades of ACP as required complete all as specified and as directed.
M&L for 18mm thick designed rubco hut rubber wood frame shutter for cupboard, WHB counter cupboard with finish to match all adjoining surfaces including sanding and applying mixture of filler and NCD thinner (Sheenlac make), pasting chalk putty, applying sealer (Sheenlac make) and wall nut colour stainer and finally applying waxpol (Silicon make) complete all as specified and as directed.
Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, light fittings, junction/terminal boxes etc; removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed.
Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
Taking down carefully old unserviceable light fittings only and removing from site complete all as specified and as directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE LIGHT/FAN point controlled by one, one way 6 Amps modular switch.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on independent board.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on same board.
M&L for Point wiring complete with 4.0 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps modular switch on independent board.
S&F modular switch, one way, one module, single pole, 6 Amps complete all as specified and as directed.
S&F modular switch, one way, one module, single pole, 16 Amps complete all as specified and as directed.
S&F modular socket, multipurpose, 2/3 pin combined, 2 module, single pole, 6 Amps complete all as specified and as directed.
S&F modular socket, multipurpose, 2/3 pin, 6/16 Amps combined, 2 module, single pole, complete all as specified and as directed.
S&F modular electronic fan regulator for ceiling fan, step type, 5 speed, AC, 2 module, 120 watts, 240 volts complete all as specified and as directed.
M&L for ceiling rose, three terminal, 65x20mm size, PVC/Polycarbonate, insulated body, 6A, 240 volts complete all as specified and as directed.
M&L for Sub main wiring complete with two runs (1P+1N) of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 4.0 Sqm copper conductor, One run of 4.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
S&F decorative ultra slim linear LED light fixture of 18 Watts capacity, recess mounted, 230 Volts, 50 Hz AC supply, extruded aluminium heat sink, environmental friendly energy efficient light fitting, surface mounted round in shape complete all as specified and as directed. MAKE: Crompton Cat part No. LSCRM-18W-WW/ Philips Model No Astra Max Metal panel or equivalent in HAVELLS
S&F Tube light fittings LED 20 watts 4 feet including all accessories and fixing arrangements complete all as specified and directed Make :CG Cat Part No : CCS-100-20-65-HL2-DP-NWH/ Philips Cat Part No : Astra line plus/C&S/Havells
S&F Tube light fittings 2 feet mirror optical including all accessories and fixing arrangements complete all as specified and directed. Make : Philips Model No LED 48027/65/86 ultron/ CG Cat No LCL-14-CDL/Havells
S&F 25 watts LED VBuilding Security light fittings IR 65 luminaire. Pressure die cast aluminium housing powder coated graphite grey and toughened glass of IP 65 including necessary fixing arrangements as per site requirements complete all as specified and directed. Make : C & S Model No. LTESSE25WLED/ Philips Model No. BRP020LEDHP/CW240V25/ CG Cat No - LSTO-25-CDL/ Havells/ Luker Cat Part No : LOHY210 WH
M&L for street light mounting bracket made up of 25mm dia galvanised steel tubing, medium grade, 1.20 metres long, bent to shape with inner angle not less than 120°, with and including necessary fixing clamps fabricated out of angle iron/flat iron of suitable size, bolts, nuts and washers as required and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F Exhaust fan 150 mm sweep, BLDC Motor stainless steel finish, 6.5 watts, energy efficient, with louvers including all fixing arrangement complete all as specified and directed Make: Atomberg Model : Studio/ CG/ Havells/ Orient/ Usha
S&F ceiling fan of three blades metallic colour, remote controlled, 1200mm sweep, 360 RPM, suitable for AC 230 volts, heavy duty with down rod and canopies complete all as specified and as directed. MAKE: Atomberg Model: Studio (Pearl White)/ Havells/ Usha/ CG
S&F SPN DB sheet metal enclosure double door suitable (IP-43) Protection 8 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete. Make : Havells/L&T/Indo Asian/Legrand/Schneider
S&F MCB, SPN, "C" series, 240 volts, 63 Amps, 10 KA rupturing capacity complete all as specified and as directed. Make : Havells/L&T/Indo Asian/Legrand/Schneider
S&F MCB, SPN, "C" series, 240 volts, 32 Amps, 10 KA rupturing capacity complete all as specified and as directed. Make : Havells/L&T/Indo Asian/Legrand/Schneider
S&F MCB, SP, "C" series, 240 volts, 6-32 Amps, 10 KA rupturing capacity complete all as specified and as directed. Make : Havells/L&T/Indo Asian/Legrand/Schneider
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
M/S VISHAL CONSTRUCTION
SHUBHAM SHANKAR GAIKWAD
M/s K Moorthi
M/s Ramesh Lal
Sree Tirumala Enterprises
kakolil trade agencies
M/S TANISHA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .