| Sl No | Description | Qty | Unit | M/S MARTAND TREADERS L5 | M/S AB ELECTRICAL AND MECHANICAL WORKS L6 | BHAT SALES CORPORATION L3 | M/S BHAT ENGINEERING L2 | ZEESHAN ELECTRICAL AND CONTRACTORS L1 | NEW AHANGER ENGINEERING WORKS L7 | MOHAMMAD RAFIQ BHAT L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and installation of GI Chemical Earthing Electrode, 2.5 meters long and 50 mm diameter, including all necessary accessories such as backfill compound, clamps, and connectors. The work also includes construction of a 4-inch thick brick masonry manhole (1 ft x 1 ft x 1 ft) at top with plastering on both inner and outer surfaces, and provision of a manhole cover with locking arrangement, all as per the instructions of the site engineer and relevant standards | 12 | Job | 11,000 ₹1.3 L | 8,999 ₹1.1 L | 12,500 ₹1.5 L | 10,500 ₹1.3 L | 12,000 ₹1.4 L | 11,700 ₹1.4 L | 11,500 ₹1.4 L |
| 2.00 | Providing and fixing of 50mmx6mm GI strip on surface or in recess for extending the earthing from earth electrode to controlling panelin one rim to be laid through required dia. of PVC conduit. | 150 | Mtr | 125 ₹18,750 | 254.99 ₹38,248.50 | 90 ₹13,500 | 200 ₹30,000 | 70 ₹10,500 | 129 ₹19,350 | 50 ₹7,500 |
| 3.00 | Providing and fixing Aluminium armoured XLPE insulated aluminium conductor cable from main panel board to various equipment’s through walls/celling with appropriate clamps and fixing arrangements as per site requirement.3.5 Core 120 Sqmm | 90 | Mtr | 1,100 ₹99,000 | 1,499 ₹1.3 L | 950 ₹85,500 | 790 ₹71,100 | 500 ₹45,000 | 1,192 ₹1.1 L | 900 ₹81,000 |
| 4.00 | Providing and fixing of Of Load Change Over switch 415 Volts, sheet metal enclosures, 4 Pole of capacity 400 Amps, complete in all respects as per site requirement. | 1 | No | 32,000 ₹32,000 | 34,999 ₹34,999 | 35,000 ₹35,000 | 22,500 ₹22,500 | 40,000 ₹40,000 | 34,000 ₹34,000 | 50,000 ₹50,000 |
| 5.00 | Supply, installation, testing, and commissioning of 4-pole MCCB rated for 250 A, 415 V, 3-phase, with minimum breaking capacity of 50 kA, including all accessories, lugs, cable termination, mounting hardware, and integration into existing panel board as per site conditions and technical specifications. | 1 | No | 26,000 ₹26,000 | 24,999 ₹24,999 | 25,000 ₹25,000 | 14,900 ₹14,900 | 18,000 ₹18,000 | 28,900 ₹28,900 | 35,000 ₹35,000 |
| 6.00 | Providing and fixing of 150 mm wide perforated cable tray made of 2 mm thick MS sheet, supported from ceiling or wall using suitable brackets, clamps, and hardware, including painting with one coat of primer and two coats of synthetic enamel paint as per site conditions and technical specifications. | 40 | RMT | 560 ₹22,400 | 99 ₹3,960 | 420 ₹16,800 | 400 ₹16,000 | 200 ₹8,000 | 711 ₹28,440 | 300 ₹12,000 |
| 7.00 | Providing and fixing of 4 mm 2 Core copper wire for input to AHU of Dermetology. | 40 | Mtr | 175 ₹7,000 | 229 ₹9,160 | 100 ₹4,000 | 100 ₹4,000 | 100 ₹4,000 | 175 ₹7,000 | 155 ₹6,200 |
| 8.00 | Providing, fitting, testing, and commissioning of 200-watt warm white outdoor-type LED flood light of reputed make for boiler house IP66-rated for dust and water resistance, with high-efficiency LED driver, power factor ≥ 0.95, lumen output ≥ 20,000 lm, color temperature 3000–3500K, and CRI ≥ 80, mounted on suitable GI bracket or wall arm with all required mounting accessories. The luminaire shall be housed in corrosion-resistant powder-coated aluminum body with toughened glass cover and built-in surge protection ≥ 6 kV. Work includes supply and laying of 3-core 4 sq.mm copper wire through heavy-duty PVC conduit from existing power source, earthing with GI strip, and provision of MCB (10A SP) in weatherproof enclosure for circuit protection. Installation shall comply with IS:10322 (Part 5/Sec 3), IS:15885, and site-specific safety norms | 1 | Job | 6,000 ₹6,000 | 14,899 ₹14,899 | 6,000 ₹6,000 | 8,900 ₹8,900 | 5,000 ₹5,000 | 7,200 ₹7,200 | 9,000 ₹9,000 |
| 9.00 | Providing and fitting of Medium Grade PVC Conduit including its allied accessories like bends etc for lying of wire for AHU's input. | 40 | Mtr | 95 ₹3,800 | 20 ₹800 | 60 ₹2,400 | 120 ₹4,800 | 50 ₹2,000 | 108 ₹4,320 | 50 ₹2,000 |
Updated dates
Tender Value
₹4.2 L
EMD Value
₹8,400
Closing Date
1 Dec 2025, 2:00 pmClosed
Executive Engineer
Office of the Executive Engineer Mechanical and Hospital Division Anantnag
Chemical Earthing system, Installation for electric equipment (Boiler House, Oxygen Plant, DG Set) at MMABM, AH GMC Anantnag.
2025_PWDJK_295771_1
MHDA/TS/E-TENDER/69 OF 2025-26
Open Tender
Miscellaneous Works
15 days
MMABM AH GMC Anantnag
Refer NIT
6 documents required · 6 mandatory
₹200
Executive Engineer M and H Division Anantnag
₹8,400
27 Dec 2025
20 Nov 2025
2 Dec 2025
20 Nov 2025
1 Dec 2025
20 Nov 2025
Supply and installation of GI Chemical Earthing Electrode, 2.5 meters long and 50 mm diameter, including all necessary accessories such as backfill compound, clamps, and connectors. The work also includes construction of a 4-inch thick brick masonry manhole (1 ft x 1 ft x 1 ft) at top with plastering on both inner and outer surfaces, and provision of a manhole cover with locking arrangement, all as per the instructions of the site engineer and relevant standards
Providing and fixing of 50mmx6mm GI strip on surface or in recess for extending the earthing from earth electrode to controlling panelin one rim to be laid through required dia. of PVC conduit.
Providing and fixing Aluminium armoured XLPE insulated aluminium conductor cable from main panel board to various equipment’s through walls/celling with appropriate clamps and fixing arrangements as per site requirement.3.5 Core 120 Sqmm
Providing and fixing of Of Load Change Over switch 415 Volts, sheet metal enclosures, 4 Pole of capacity 400 Amps, complete in all respects as per site requirement.
Supply, installation, testing, and commissioning of 4-pole MCCB rated for 250 A, 415 V, 3-phase, with minimum breaking capacity of 50 kA, including all accessories, lugs, cable termination, mounting hardware, and integration into existing panel board as per site conditions and technical specifications.
Providing and fixing of 150 mm wide perforated cable tray made of 2 mm thick MS sheet, supported from ceiling or wall using suitable brackets, clamps, and hardware, including painting with one coat of primer and two coats of synthetic enamel paint as per site conditions and technical specifications.
Providing and fixing of 4 mm 2 Core copper wire for input to AHU of Dermetology.
Providing, fitting, testing, and commissioning of 200-watt warm white outdoor-type LED flood light of reputed make for boiler house IP66-rated for dust and water resistance, with high-efficiency LED driver, power factor ≥ 0.95, lumen output ≥ 20,000 lm, color temperature 3000–3500K, and CRI ≥ 80, mounted on suitable GI bracket or wall arm with all required mounting accessories. The luminaire shall be housed in corrosion-resistant powder-coated aluminum body with toughened glass cover and built-in surge protection ≥ 6 kV. Work includes supply and laying of 3-core 4 sq.mm copper wire through heavy-duty PVC conduit from existing power source, earthing with GI strip, and provision of MCB (10A SP) in weatherproof enclosure for circuit protection. Installation shall comply with IS:10322 (Part 5/Sec 3), IS:15885, and site-specific safety norms
Providing and fitting of Medium Grade PVC Conduit including its allied accessories like bends etc for lying of wire for AHU's input.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.41 MB
BOQ_957660.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid