Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹20.2 LAccepted-AOC | 1 | Accepted-AOC Lowest1 | |
| 2 | 2₹21.0 L+₹75,520 (3.72%)Rejected-Finance FEROZEPUR | FEROZEPUR | FEROZEPUR | 2 | Rejected-Finance lowest2 |
Tender Value
₹17.9 L
EMD Value
₹35,880
Closing Date
8 Dec 2023, 12:00 pmClosed
XEN MAJITHA PIMTI COMPLEX ASR
XEN MAJITHA PIMTI COMPLEX ASR
Estimate for Construction of bridge at RD 2175 of Manj Minor
2023_WR_111298_2
E Tender Notice No-134
Open Tender
Civil Works - Canal
Item Wise
120 days
XEN MAJITHA PIMTI COMPLEX ASR
AS PER SBD CONDITIONS
3 documents required · 3 mandatory
₹2,000
₹35,880
Yes
26 Feb 2024
31 Oct 2023
8 Dec 2023
31 Oct 2023
8 Dec 2023
31 Oct 2023
Dismantling brick work tile, masonry In cement
Earth work in excavation of foundation of structures as per drawing and technical specification,including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil. (Depth 3 m )
Back filling behind abutment, wing wall andreturn wall complete as perdrawing and TechnicalSpecification. Sandy material.
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. PCC Grade M15
Furnishing and Placing Reinforced/Prestressed cement concretein/sub-structure superstructureas per drawing and Technical Specification. RCC Grade M-30, Height upto 5m (i) Using Concrete Mixer
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications RCC Grade M 30
Furnishing and PlacingReinforced/ Prestressed cement concrete in super structure as per drawing and Technical Specification RCC Grade M 30-For solid slab Using Concrete Mixer (a) For Solid slab super-structure including centering and shuttering (i) Height up to 5m
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications using RCC Grade M-25
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M25 Height upto 5m (i) Using Concrete Mixer
22.1 E (A) Prestressed cement concrete (i) in superstructure as per drawing and TechnicalSpecification RCC/PSC Grade M-40 Using Concrete Mixer (a) For Solid slab super-structure including centering and shuttering
22.2 Supplying, fitting and placing HYSD bar reinforcumcement in super-structure completeas per drawing and technical specifications.
Drainage Spouts complete as perdrawing no. SD/205 andTechnical specification with 0.6meter long GI 100 mm dia drainageGI light grade pipe (For Bridges)
Providing and applying 2 coats of waterbased cement paint to unplastered concretesurface after cleaning the surface of dirt,dust, oil, grease, efflorescence and applyingpaint @ of 1 litre for 2 sqm.
Tar Papper Polythene films/ sheet of 100,125, 150, 200,250 micron( blow slab at abutment bed plates).
Filling Expansion joint, with special bituminous material of size 20mm wide and approx 600 mm deep in bridge slab to provide for horizontal movements and vertical movement all as per approved drawings and specification.
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.160mm o/d PVC pipe of 4 Kgf. / sqcm
Rehandling of earth work complete in all respect as per drawing, design specification and instruction of engineer in charge
compaction completein all respect as per drawing ,design specificationand instruction of engineer inchargeextra for laying /earth fly ash as per specification in 20 cm .layers and dressing but excluding cost of rolling
compaction completein all respect as per drawing ,design specificationand instruction of engineer inchargeextra for watering the earth/ fly ash laid in 20 cm layer as per specification for compaction .
compaction completein all respect as per drawing ,design specificationand instruction of engineer inchargeextra for rolling to specification
Earth work for lipcutting for linning of irrigation channels inclusive of all allowance lead and dressing. Complete in all respect asper specification
Dressing of side slopes and prepration of sub grade for linning . Complete in all respect as per specification
Bricks First Class (Clay/Fly Ash) (at kiln site):- (Note:- District wise rates for Bricks / tiles attached at Annxure-II (a)Bricks 22.86cm x 11.11cm x 6.83cm hand moulded at kiln site average rate of all Districtscredits of brick bats
Brick bats from well burnt or burnt bricks
Any other Item
The Baba Mansa Giri Cooperative Labour and Construction Society Ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .