At LJN Division - Improvement of NER officers's club at bandariyabagh officer colony.
NER-LJN-2026-25
NER-LJN-2026-25
Open
6 Months
Kachchh, Gujarat
₹0
₹2.2 L
5 Feb 2026
5 Feb 2026
A-CPWD DSR-2021
Item Breakup - A-CPWD DSR-2021
wall thickness of 1.9 +/- 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). LUCKNOW-NER-DIVISION-ENGINEERING/NORTH EASTERN RLY 9.147D.4 Three track three panels sliding window with fly Sqm 30 9642.6 289278 proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having 21 wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). 10.0 STEEL WORK Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and 10.16 applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 22 10.16.1 Hot finished welded type tubes Kg 3024 154.9 468417.6 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in 10.25 position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar, ladder, railings, Kg 1200 142.3 170760 23 brackets, gates and similar works 11.0 FLOORING 11.37S CERAMIC GLAZED TILES 11.37 Providing and laying Ceramic glazed floor tiles Sqm 60 935.6 56136 of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 24 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 11.41S VITRIFIED FLOOR TILES Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey 11.41A cement slurry @3.3 kg/sqm including grouting t h e joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.2 Glazed vitrified floor tiles polished finish of size 25 11.41A.2.1 Size of Tile 600 x 600 mm Sqm 150 1359.2 203880 26 11.41A.2.4 Size of Tile 800 x 1200 mm Sqm 450 1859.6 836820 12.0 ROOFING Providing, fixing and embedding sand cast iron accessories for rain water pipes in the masonry 12.40 surrounded with 12 mm thick cement mortar of the same mix, as that of masonry (lead caulking will be paid for separately): Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 12.41 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 27 12.41.2 110 mm diameter Metre 96 319.75 30696 LUCKNOW-NER-DIVISION-ENGINEERING/NORTH EASTERN RLY Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes 12.42 conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 12.42.5 Bend 87.5 degrees 28 12.42.5.2 110 mm bend Each 96 132 12672 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of 12.43 required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 29 12.43.2 110 mm Each 48 309.5 14856 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. 12.45 wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.45.1 12.5 mm thick tapered edge gypsum plain Sqm 600 1145.95 687570 30 board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) 12.45.2 12.5 mm thick tapered edge Glass Reinforced Sqm 250 1286.45 321612.5 Gypsum (GRG) board conforming to IS: 2095- 31 (Part 3):1996 (Boards with BIS certification marks) LUCKNOW-NER-DIVISION-ENGINEERING/NORTH EASTERN RLY 12.50 Providing and fixing precoated galvanised iron Sqm 201.6 671.55 135384.48 profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to 32 avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 13.0 FINISHING 13.1S CEMENT PLASTER (IN FINE SAND) 13.1 12 mm cement plaster of mix : 33 13.1.2 1:6 (1 cement: 6 fine sand) Sqm 2500 282 705000 13.4S CEMENT PLASTER (IN COARSE SAND) 13.4 12 mm cement plaster of mix : 34 13.4.2 1:6 (1 cement: 6 coarse sand) Sqm 2500 294.35 735875 15 mm cement plaster on rough side of single 13.5 or half brick wall of mix: 35 13.5.1 1:4 (1 cement: 4 coarse sand) Sqm 240 354.5 85080 Distempering with oil bound washable 13.41 distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and Sqm 4500 162.55 731475 36 including water thinnable priming coat with cement primer 13.44S EXTERIOR FINISHING Finishing walls with water proofing cement paint 13.44 of required shade : 13.44.1 New work (Two or more coats applied @ 3.84 Sqm 4500 97.6 439200 37 kg/10 sqm) Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali 13.48A & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.48A.1 New work (Two or more coats applied @ 1.43 Sqm 540 154.45 83403 38 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 13.80 Providing and applying white cement based Sqm 6500 123.85 805025 putty of average thickness 1 mm, of approved 39 brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Applying priming coats with primer of approved 13.85 brand and manufacture, having low VOC (Volatile Organic Compound ) content. 13.88 Removing white or colour wash by scrapping Sqm 2500 16.35 40875 and sand papering and preparing the surface 40 smooth including necessary repairs to scratches etc. complete 13.91 Removing dry or oil bound distemper, water Sqm 4500 20.85 93825 proofing cement paint and the like by 41 scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. LUCKNOW-NER-DIVISION-ENGINEERING/NORTH EASTERN RLY Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 13.108 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer's specification. 42 13.108.1 One or more coats on old work Sqm 2500 50.6 126500 Finishing walls with water proofing cement paint 13.109 of required shade : 13.109.1 Old work (one or more coats applied @ 2.20 Sqm 1200 94.15 112980 kg/10 sqm) over priming coat of primer applied 43 @ 0.80 litrs/10 sqm complete including cost of Priming coat. 14.0 REPAIRS TO BUILDING Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm 14.2 nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 44 14.2.1 Door chowkhats Each 25 1505.3 37632.5 14.12 Providing and fixing 16 mm M.S. Fan clamps of Each 48 468.4 22483.2 standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to 45 reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. Renewing wooden beams in roofs including making good the holes in walls and painting with oil type wood preservative of approved 14.16 brand and manufacture complete, including removal of rubbish to the dumping ground, all complete as per direction of Engineer-in- Charge. 14.17 Raking out joints in lime or cement mortar and Sqm 3500 59.75 209125 preparing the surface for re-pointing or 46 replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 14.72S FINISHING 14.72 Providing and fixing double scaffolding system Sqm 1200 285 342000 (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding 47 system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. 15.0 DISMANTLING AND DEMOLISHING LUCKNOW-NER-DIVISION-ENGINEERING/NORTH EASTERN RLY 15.3 Demolishing R.C.C. work manually/ by cum 20 2928.1 58562 mechanical means including stacking of steel 48 bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. Demolishing brick work manually/ by mechanical means including stacking of 15.7 serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 49 15.7.3 In lime mortar cum 80 701.95 56156 50 15.7.4 In cement mortar cum 100 1698.45 169845 15.31 Dismantling tiled roofing with battens, boarding Sqm 120 173.15 20778 etc. complete including stacking of serviceable 51 material and disposal of unserviceable material within 50 metres lead. 15.56 Dismantling old plaster or skirting raking out Sqm 600 45.05 27030 joints and cleaning the surface for plaster 52 including disposal of rubbish to the dumping ground within 50 metres lead. 15.60 Disposal of building rubbish / malba / similar cum 80 219.35 17548 unserviceable, dismantled or waste materials by mechanical means, including loading, 53 transporting, unloading to approved municipal dumping ground or as approved by Engineer-in- charge, beyond 50 m initial lead, for all leads including all lifts involved. 17.0 SANITARY INSTALLATIONS Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with 17.1 manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of Each 4 5781.35 23125.4 54 size 580x440 mm with integral type foot rests Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm 17.7 C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450 Each 10 2275 22750 55 mm with a pair of 15 mm C.P. brass pillar taps 17.8 Providing and fixing white vitreous china Each 10 1500.05 15000.5 56 pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 17.9 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: 17.9.1 White glazed fire clay kitchen sink of size Each 5 3302.95 16514.75 57 600x450x 250 mm Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, 17.10 including painting of fittings and brackets, cutting and making good the walls wherever required : 17.10.1 Kitchen sink with drain board 58 17.10.1.1 510x1040 mm bowl depth 250 mm Each 5 6008.45 30042.25 17.22A Providing and fixing CP Brass 32mm size Bottle Each 10 886.25 8862.5 59 Trap of approved quality & make and as per the direction of Engineer-in-charge. LUCKNOW-NER-DIVISION-ENGINEERING/NORTH EASTERN RLY 17.22B Providing and fixing CP Brass Single lever Each 5 6119.15 30595.75 telephonic wall mixer of quality & make as 60 approved by Engineer in charge. (a) 15 mm nominal dia 17.80 Providing and fixing white vitreous china battery Each 5 7004.45 35022.25 based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml 61 consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 17.81 Providing and fixing floor mounted, white Each 5 16100.4 80502 vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres 62 with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in- Charge. 18.0 WATER SUPPLY 18.7S C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing 18.7 the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.-Internal work - Exposed on wall 63 18.7.1 15 mm nominal dia Pipes Metre 250 255.9 63975 64 18.7.2 20 mm nominal dia Pipes Metre 150 325.1 48765 65 18.7.3 25 mm nominal dia Pipes Metre 200 408.55 81710 18.15S BRASS FITTINGS Providing and fixing brass stop cock of approved 18.16 quality : 66 18.16.1 15 mm nominal bore Each 15 303.85 4557.75 67 18.16.2 20 mm nominal bore Each 20 327.95 6559 Providing and fixing gun metal gate valve with 18.17 C.I. wheel of approved quality (screwed end) : 68 18.17.1 25 mm nominal bore Each 10 532.35 5323.5 69 18.17.1A 20 mm nominal bore Each 10 461.75 4617.5 C.I. SLUICE VALVES/ FIRE HYDRANTS & 18.31S FIXTURES 18.48 Providing and placing on terrace (at all floor Litre 5000 9.7 48500 levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking 70 arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 21.0 ALUMINIUM WORK LUCKNOW-NER-DIVISION-ENGINEERING/NORTH EASTERN RLY Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with 21.1 required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : 21.1.1 For fixed portion 21.1.1.2 Powder coated aluminium (minimum thickness Kg 250 466.3 116575 71 of powder coating 50 micron) 21.1.1.3 Polyester powder coated aluminium (minimum Kg 150 474.7 71205 72 thickness of polyester powder coating 50 micron) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings 21.1.2 wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2.2 Powder coated aluminium (minimum thickness Kg 50 564.8 28240 73 of powder coating 50 micron) 21.1.2.3 Polyester powder coated aluminium (minimum Kg 60 573.4 34404 74 thickness of polyester powder coating 50 micron) Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum 21.2 doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 21.2.1 Pre-laminated particle board with decorative Sqm 125 965.1 120637.5 75 lamination on one side and balancing lamination on other side Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. 21.3 complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 21.3.1 With float glass panes of 4.0 mm thickness Sqm 45 1019.8 45891 76 (weight not less than 10kg/sqm) 21.3.2 With float glass panes of 5 mm thickness Sqm 35 1325.55 46394.25 77 (weight not less than 12.50 kg/sqm) Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, 21.4 embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. LUCKNOW-NER-DIVISION-ENGINEERING/NORTH EASTERN RLY 21.4.1 With stainless steel cover plate minimum 1.25 Each 10 2448.85 24488.5 78 mm thickness 21.18 Providing and fixing 12 mm thick frameless Sqm 30 4540.7 136221 toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic 79 floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 22.0 WATER PROOFING 22.14 Grading roof for water proofing treatment with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse cum 25 7510.75 187768.75 80 sand : 4 graded stone aggregate 20mm nominal size) Total 12561103.89
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Supplyofrainforcedsteelsplcondition2025.pdf
InstructionstoTenderers52025.pdf
POAGuidelines.pdf
GeneralConditions09.09.2025_1.pdf
GCC-2022-updateduptoACS10.pdf
SFMSPolicyBGverificationviaSFMS.pdf
Download all tender documents and submit your bid