Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.1 LAccepted-AOC 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹23.8 L+₹45,594 (1.95%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹30.0 L+₹6.6 L (28.2%)Rejected-Finance 0 | 3 | Rejected-Finance Being other than L-1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
29 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Sharath Ravindran CWE
HQ CWE (AF) Chakeri Kanpur Pin-208008
REPAIR MAINT OF HT DISTRIBUTION NETWORK (33 AND 11 KV) STEP DOWN UP TRANSFORMER AND PROTECTION DEVICES WITH ALLIED WORKS UNDER AGE (I) AF MANAURI
2021_MES_484768_2
CA No. CWE (AF) /CHK/MNR/T-27 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE (I) Manauri
Class D Category b (ii)
8 documents required · 8 mandatory
₹500
AGE (I) Manauri
₹60,000
Yes
14 Jan 2022
8 Dec 2021
5 Jan 2022
8 Dec 2021
29 Dec 2021
15 Dec 2021
60 days
Amount
Labour for disconnecting /taking out/ cutting etc to XLPE insulated cable upto 33 KV graded in any specification/ size/ core etc from trench/ tray / pole / GOD etc as site to replacing the defective piece/ portion OR jointing by straight through/ end termination joint kit etc incl removing brick/ cable cover safely for re-using as same existing complete all as directed and quoted unit rate included such aspect. Note: (i) Earth work shall be measured and paid against respective item. (ii) Required T&P and safety equipment’s shall be arranged by contractor. (iii) Any other part replaced during execution shall be measured and paid separately under respective items.
Labour for fault detecting location by using vehicle mounting fault locator machine to move along route layout of XLPE insulated HT 11/33 KV under ground cable at various location at AOR by gradually step by step testing of tracing the correct fault location incl making all testing after re-laying of repaired cable as per existing complete all as specified and directed. Note:- Quoted unit rate shall be deemed included cost of payment of fees for providing fault locator machine from State Govt Electricity authority and its transportation including diesel & driver charges complete. Govt receipt for payment made for state Govt Electricity authority be produced to Engineer-in-charge at every time before making payment to contractor.
Labour for re-laying, connecting, jointing, thembling using in suitable size and cramping etc to serviceable XLPE insulate cable upto 33 KV grade (Earthed) in all specification incl brick (re-use) and sand (Provided fresh) etc all as per existing complete with other site required works complete all as specified and directed. Note : Sand cushioning punned dept shall be measured and paid separately under respective items.
Supply, laid in trench/ fixed with surface of wall / roof etc, jointing, thembling and glanding in suitable size , testing in replacement to HT XLPE cable insulated, screened, PVC bedded galvanised steel strip or wire armored electric power cable (heavy duty) with alumunium conductor 33 KV, grade cross section area 300 Sqmm of 3 core complete all as specified and directed. Note : Excavation earth work cable cover, sand cushioning etc shall be measured and paid separately under respective items)
Supply, laid in trench/ fixed with surface of wall / roof etc, jointing, thembling and glanding in suitable size , testing in replacement to HT XLPE cable insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) with alumunium conductor 11 KV, grade cross section area 240 Sqmm of 3 core complete all as specified and directed. Note : Excavation earth work cable cover, sand cushioning etc shall be measured and paid separately under respective items)
Supply, laid in trench/ fixed with surface of wall / roof etc, jointing, thembling and glanding in suitable size , testing in replacement to HT XLPE cable insulated, screened, PVC bedded galvanised steel strip or wire armored electric power cable (heavy duty) with alumunium conductor 11 KV, grade cross section area 120 Sqmm of 3 core complete all as specified and directed. Note : Excavation earth work cable cover, sand cushioning etc shall be measured and paid separately under respective items)
Supply, laid in trench/ fixed with surface of wall / roof etc, jointing, thembling and glanding in suitable size , testing in replacement to LT XLPE cable insulated, screened, PVC bedded galvanised steel strip or wire armored electric power cable (heavy duty) with alumunium conductor 11 KV, grade cross section area 10 Sqmm of 2 core (for out fit area light) complete all as specified and directed. Note : Excavation earth work cable cover, sand cushioning etc shall be measured and paid separately under respective items.
All as above item no-07 but here -in - before in replacement suitable for 1100 volt grade cross section area 10 Sqmm x 4 core. Note : Excavation earth work cable cover, sand cushioning etc shall be measured and paid separately under respective items.
Excavation in trenches not exceeding 1.5 Mtr wide in not exceeding 1.5 Mtr in depth for foundation etc or for shaft well, cesspits, manholes, pier hole etc not exc 10 Sqmm on plan and not exceeding 1.5 Mtr in depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 CM complete all as specified and directed.
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete.
M&L for sand cushioning (dry sand) to under ground cable for cable 80cm below cable and 15 cm above cable including punning down to 10 cm by mechanical roller complete protection all as specified and directed. (Note : Punned thickness of sand shall be measured and paid to contractor).
Supply and laying reinforced precast concrete cable cover, class HVP, type 2 with peak size 300 mm x 180 mm x 40 mm thick suitable for 33 KV cable complete all as specified and directed.
All as above item no-13 but here in before class HV, type-1, flat, size 450 mm x 180 mm x 40 mm thick suitable for 11 KV cable complete all as specified and directed. NOTE : FOR ITEM NO 13 & 14 HT CABLE COVER shall be procured from M/s Mehtab Pavers tiles, Indore duly embossed ISI mark & name of Company)
M&L for brick, old sub class 'B' well burnt, laid dry flat in trenches for protection of cable over LT cable complete all as specified and directed.
Labour for cutting /boring to plinth protection/ hard standing / road etc in suitable depth to across the GI pipe size upto 80 mm dia of bore for drawn through XLPE under ground cable for giving mechanical protection to cable complete all as directed. (Note : Quoted rate shall be included the cost of required material for repairing to disturbed surface complete all as per existing site and all as directed by Engineer-in-charge.
Labour for cutting /boring to plinth protection/ hard standing / road / Main National highway etc in suitable clear depth minimum 1.2 Mtrs (excluding dia of pipe) for accrossing the reinforced concrete pipe class NP 3 dia of bore upto 450 MM (as site required) for drawn through XLPE under ground cable for giving mechanical protection to cable complete all as directed. Note ; Quoted rate shall be included the cost of required material for repairing to disturbed surface all as per existed.
M&L in replacement to GI tubing light grade 150 mm dia of bore with all fitting laid in trenches across the road or fixed with pole/ surface of wall etc as site with required fixing accessories complete all as specified and directed. (Make : Tata or Jindal or Swastic)
All as above item No-18 here in before but in size 80 mm dia of bore. (Make : Tata or Jindal or Swastic)
All as above item No-18 here in before but in size 50 mm dia of bore. (Make : Tata or Jindal or Swastic)
Supply and fixing / laid in trench/ bored hole under the High way for mechanical protection to XLPE cable of as new reinforced concrete pipes class NP 3 pipe dia of bore 450 MM laid under the National high way road for crossing the HT cable including jointed complete with collars complete all as site required and directed. Note : Quoted rate shall be included the cost of required safety measures and rent of boring machine etc all required other work for acrossing the above pipe under the full functioned National high way in suitable depth.
Supply, fixing, connecting jointing thembling to end of cable, testing etc in replacement to cable jointing kit for 11KV (earthed) grade cable for out door end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core x 95 to 185 Sqmm XLPE armored alumunium conductor cable complete all as specified and directed. (Note : Excavation & work shall be measured and paid against respective items) (Make : Denson or M- Seal or Raychem)
All as above item No-22 here-in-before but size 3 core x 120 to 185 Sqmm (earthed) indoor type end termination .(Note : Excavation & work shall be measured and paid against respective items) (Make : Denson or M- Seal or Raychem)
All as above item No-22 here-in-before but out door straight through heat shrink type joint suitable for, 11 KV graded 3 core x 120 to 185 Sqmm (earhted) XLPE armoured cable. (Note : Excavation & work shall be measured and paid agaist respective items) (Make : Denson or M- Seal or Raychem)
Supply, fixing, connecting, jointing, thembling to end of cable and commissioning and testing in replacement of heat shrinkable cable jointing kit suitable for 33 KV grade (earthed) cable for outdoor type end termination complete with jointing material and accessories suitable for 3 core XLPE insulated armored aluminium conductor cable of size 300 Sqmm 3 core including taking down existing complete all as specified and directed. (Note : Excavation & work shall be measured and paid against respective items) (Make : Denson or M- Seal or Raychem)
All as above item No-25 here-in-before but size 3 core x 300 Sqmm (earthed) but indoor type end termination complete.
All as above item No-25 here-in-before but straight through heat shrink type joint suitable for, 33 KV graded 3 core x 300 Sqmm (earthed) XLPE armored cable complete.
M&L painting to steel prepared surfaces of any width or girth not otherwise described by using synthetic enamel paint in two coats (one as finishing coat) over one coat of red oxide zinc chrome primer on surface of steel structure /girder/ angle frame/ wire mesh fencing etc in any description at E/M installation using paint spray gun on specified working pressure including sign making / marking with using different colour in given size of letter etc complete all as specified and directed. Note : Paint colour & shade including writing marking of letters etc shall be deemed included in quoted unit rate and the same shall be approved by Engr-in-charge)
M&L painting using heat resisting paint in two coats (one as finishing) over one coat of red oxide zinc chrome primer on external surface of transformer in any rating/capacity using Ist quality paint and applying through spray gun machine on specified working pressure incl writing of MES/SM No using different colour including writing letter in given size etc after removing/scrapping/rubbing to old fedded paint and filler filling etc complete all as specified and directed. Note : Quoted unit rate shall be deemed included cost of writing letters & filling depresion by using putty, complete Colour & shade shall be approved by Engr-in-charge)
M&L painting to external surface of old painted steel tubular pole upto 11 Mtr height in various location using aluminium paint in two coats (one as finishing) by spray gun after removing/ cleaning/ scraping etc to old fadded paint incl cross arm, support complete all as directed by Engineer in-charge at site and making alternating strip in 30 CM width each upto 1.5 Mtrs above normal ground level and marking pole numbers etc with all sign complete all as specified and directed. Note : Paint colour & shade shall be approved by AGE (I) and tree shrub cutting near poles shall be deemed included in quoted unit rate.
M & L Painting to existing four steel pole structure of 11 Mtr height including mild steel work like cross arms, clamps, pipe channel, bracing etc after cleaning and preparation of surfaces painting externally above planting depth with one coat of aluminum paint over a coat of aluminum primer including preparation of existing surfaces and marking pole numbers in 15 CM dia with approved colour in circular and making 03 Numbers & 02 Numbers of bands & strips with 30 CM wide fluorescent paint from bottom of pole to 1.5 Mtr height of pole complete all as specified and as directed. (Note : Cutting of bushes & tree branches upto 3m height of pole shall be deemed included in quoted unit rate).
M & L Painting to existed PTs/ CTs /GOD/ run of ACSR in colour coding etc of 3 three phase distribution bay/ network of 33 KV yard from end terminating point to transformer HT leg/ studs using luminous paint for phase indication in colour coding (Red, blue and yellow) phase wise in two coats over one coat of red primer including cleaning /preparation/ removing etc to old paint on external surfaces of existed located protection equipment’s as above and marking as per given by Deptt complete all as specified and as directed. Note : Quoted rate shall be including the cost of painting to external surface of PTs/ CTs/ control panel in existed colour complete all as specified and directed.
M&L for cement concrete type C-2 in ratio 1:3:6 using 40mm graded aggregate as in foundation filling and mass concrete complete all as specified and as directed.
M&L for cement concrete type in ratio 1:2:4 using 20mm graded aggregate as in foundation filling and mass concrete complete all as specified and as directed.
M&L brick work with sub class 'B' bricks using old size bricks straight or curved on plan exc 6m mean radius built in cement mortar CM (1:6) for plinth foundation & cable trenches E/M installation complete all as specified & directed.
Supply and filling broken/crushed stone boulder filling dry hand packed tightly laying in layers on ground surface in size 40 to 50 mm after excavation, removing, dressing, leveling, compact work etc all as per site requirement on existing ground surface of E/M installations complete all as specified and directed. (Note:- Quoted unit rate shall be deemed included cost required for earth work to prepare the surface for laying boulder in layers with compact work).
M&L 15 mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surface finished even and smooth without using extra cement including taking down of existing plaster complete all as specified and directed .
Supply and fixing in replacement to cross arms / angle frame / MS sheet to made out bracings supports / clamp , back plates fabricated from structural steel sections nut bolt washers cutting welding to hot /cold drilling holes for bolts in any shape or size as indicated incl painting in two coats using synthetic enameled paint over one coat of primer red oxide complete all as specified and directed.
M&L Servicing of 33 KV switch yard outdoor equipment including isolators, CTs-4 Set, PTs-4 Set, lightening arrestor and all the other outdoor equipment by opening their connection and cleaning contacts with sand paper, greasing the equipment whose required reconnecting all the connections complete all as specified and directed. (Note: The rates quoted shall be deemed included cost of T&P and other items required at site
M&L Servicing of 11 KV distribution network outdoor equipment including isolators, CTs-4 Set, PTs-4 Set, lightening arrestor GODs (oiling/ greasing) by opening their connection and cleaning contacts with sand paper, greasing the equipment whose required reconnecting all the connections including replacement as new supply and fixing minor spares of GOD as nut bolt washer barrel fuses, copper fingers (male and female) operating handle, locking arrangement etc all required for making serviceable complete all as specified and directed. (Note:- The rates quoted shall be deemed included cost of T&P and other items required at site).
Labour only for calibration/relay setting and servicing of all types of relays ( Short circuit earth fault, overload protection, IDMT etc) at 33 KV Yard and substation, comprising of 33 KV control panels-4 Nos, 11 KV VCB panels-6 Nos by authorised agency/OEM through computersied software. The relay shall be duly calibrated in conformity with relay setting of RMU's installed at various HT networks and vice versa. The agency will provide the relay setting parameters in writing for future use complete all as specified and directed. (Note : Calibration of IDMT /relay shall be carried out through authorised agency of OEM only) and approved by AGE (I)).
M&L checking (all connection and mechanism) cleaning overhauling servicing of 3 phase 11 KV ring main unit (RMU) extensive type 630 Amps rating including replacement to minor spare such as spring copper finger/contact set male and female locking arrangement , operating handle, plencer assembly rocking gear, auxiliary switch, relay time re-setting, right mechanism including re-filling Gas SF -6 upto required working pressure with required spares for making serviceable etc to all for making serviceable by OEM authorised work shop only and reassembling testing and commissioning complete at site all as specified and directed. (Note:- Quoted rate shall be included cost of required other spares and SF -6 gas to made fully functional & serviceable of RMU).
Disconnecting/ removing of HT/LT cable and earth connections of copper wound, 11KV/ 433 Volts capacity 160 KVA to 400 KVA outdoor/indoor type transformer at Sub Station , by draining out of the transformer oil in empty barrels provided by the department, transporting the unserviceable transformer to a approved agency workshop of transformer overhauling from approved agency of OEM only. (T&P and vehicle to be arranged by contractor under quoted unit rate) and, servicing of transformer comprising of following works services:- (a) Opening of top cover by removing nuts, bolts and all mounting accessories and conservator tanks for visual inspection. (b) Checking of HV/LV insulators including internal inspection. (c) Replacement of corroded nuts/ bolts with double washers, burned lugs, etc by new one. (d) Servicing of tap changing gears by cleaning and polishing tapping contact points. (e) Removing, cleaning, polishing of bushings and studs of both HV/LV side by using soft cotton cloth including checking for cracking and re-fixing the same. (f) Re- fixing all cable terminals HV/LV sides and transformer top cover, conservator tank and other fitments in position. (g) Cleaning and heating of silica gel in breather. (h) Connecting HV/LV side with existing incoming and outgoing cables including re-connection of earth strip/ lead. (j) HV side cable connection shall be made with new HV tape & M seal monoplast as required at site. (k) All marshaling boxes to be cleaned from inside.
(l) All the terminal connection of control and relay wiring to be checked and tighten. (m) Examine the rollers carefully includes greasing them properly. (n) Checking of earthing connection and tightening nuts & bolts with ensuring the earthing system working properly complete all specified & directed. Note :- (i) Records shall be maintained for each transformer of each capacity duly signed by contractor and Engineer-in-Charge. (ii) Any serious faults/ defect to be carried out under this item and paid separately under respective item of sch. (iii) Inventory of parts to be replaced during overhauling of transformer at workshop will be maintained & signed by Engr-in-Charge and OEM agencies certification of transformer overhauling & their liability/guarantee/warrantee will be produced by contractor before payment of this item.
Supply, install, testing and commissioning of gang operated air break isolator switch out door type triple pole revolving type and double break suitable for horizontal mounting consisting of hot dip galvanized channel iron base having 2 Nos 33 KV working pressure post type insulator in stack and 3 such stacks per pole ,copper or copper alloy high pressure heavily tinned and double contacts plated MS arcing horns capable of breaking mgnetising current complete with phase coupling bar 25 MM dia GI pipe as down rod , lever coupling and operating handle with locking arrangement as for both ON and "OFF" positions coupling connections etc suitable fo 33 KV 3 phase 50 HZs Ac supply system having 200 Amps capacity all as speicifed in IS - 1818 of Oct 1972 including interlocking with 33 KV VCB (out door type) complete all as directed.
Supply , installation, testing and commissioning of switch air break gang operated HT 11 KV grade triple pole with 12 Nos insulators 200 Amps rating with drop out fuse assembly with fuse carrier, fuse element mounted on insulator and fitted on steel frame, mechanically operated mechanism from ground level consisting of operating rod 25 MM bore 'light grade' GI pipe of suitable length complete all as specified and as directed.
Supply and fixing, installation, commissioning and testing in replacement of lightening arrestor non-linear resistance type single pole made out of porcelain brown glazed, heavy duty station class, gapless, zinc oxide type ( non - linear ) fitted with pressure relief device, arc diverting ports, grading / corona rings, discharge counter with ammeter, mounting insulator type conforming of Fe 410W (Gde E-250) discharge 65 Kiloa Amps suitable for 33000 working volts (33KV) including dismantling of old unserviceable lightening arrester complete with comprising following parameters :- (i) Nominal system voltage : 33 KV normal discharge current rating 10 KA & high discharge with 65 KA assembly. Make: Jaipuria or BHEL or oblum or equivalent makes given in Appx 'B' duly approved by AGE (I)
M&L in replacement for lightening arrestor non linear resistor type confirming to Fe 410 W (gde -E-250) quality "A" complete line discharge class 3 nominal discharge current 10 KA & high discharge with stand 65 KA assembly suitable for 11 KV working pressure and mounted on hot dip galvanised steel structure including all clamp nuts bolt and washers etc connecting to earth 32 x 6 MM GI strip including taking out the same complete all as specified and directed. Make : Jayshree / BHEL / Oblum
M&L for chemical to burn out the shrub/grass/ unwanted small trees etc in out fit area of electrical sub station located at AOR , 33 KV MRS and other E/M installations, mixed with water in given ration and spread by using spray gun in given time interval as directed. (Note: Chemical sample shall be supplied in sealed container after approved by Deptt and time interval between to spray period will be given by Deptt).
Supply and fix for three in series each having working pressure of 33 KV disc type assembly insulator porcelain brown vitreous insulator of size 145 MM height 255 MM dia bail and sockets type for tension clamp conductor with tension clamp including galvanised mild steel spindle two Nos GI washer and nut complete all as directed.
All as above item No-49 above but post insulator suitable for working pressure 33KV in three stage complete with fixing accessories
S & F in replacement of pin type insulator of size 150 MM height, 150 MM dia, 33 KV grade, porcelain, vitreous, white, brown or green including 01 No galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nuts complete all as specified and as directed. Make: Jaipuria or BHEL or oblum or equivalent makes given in Appx 'B' duly approved by AGE (I)
All as above item No-51 above but pin type insulator suitable for working pressure 11 KV in two/ three stage complete with fixing accessories
All as above item No-51 above but disc type insulator suitable for working pressure 11 KV in size 150 MM high and 255 MM dia ball and socket two in series assembly for tension with tension clamp for conductor complete with fixing accessories
Supply and replacement on requirement to aerial fuses porcelain type suitable for line wire with brass contact bolt and nuts maximum current rating 60 Amps in 3 MM dia of wire for replacing on requirement complete all as specified and directed.
Supply and replacement on requirement to aerial fuses porcelain type suitable for line wire with brass contact bolt and nuts maximum current rating 30 Amps in 3 MM dia of wire for replacing on requirement complete all as specified and directed.
Supply and replacement on requirement to aerial fuses porcelain type suitable for line wire with brass contact bolt and nuts maximum current rating 15 Amps in 3 MM dia of wire complete all as specified and directed.
Supply and replacement on requirement to self adhesive PVC insulation tape suitable for 11 KV, 25.1 MM x 9.1 Mtrs x 0.305 MM for HT. Scotch-70 complete all as specified and directed.
Supply and replacement on requirement to scotch Rubber mastic insulation tape 2228, 2" (50 MM minimum) width and 10 feet in length suitable for 11 KV. complete all as specified and directed.
Supply and replacement on requirement to bases to aluminium themble / legs suitable for thembling to XLPE insulated cable in size 300 Sqmm x 3 core , 33 KV graded complete all as specified and directed.
Supply and replacement on requirement to aluminium themble / legs suitable for thembling to XLPE insulated cable in size 120 to 240 Sqmm x 3.0 core , 11 KV graded complete all as specified and directed.
Supply and replacement on requirement to end post rubber boot cover for fixing with 11 KV VCB (RMU) end post termination out door type for weather protection ISI marked complete all as specified and directed. Make ; Dension / M- seal
Supply and replacement on requirement to bases aluminium themble / legs suitable for thembling to XLPE insulated cable in size 95 to 185 Sqmm x 3 core , 11 KV graded complete all as specified and directed.
Supply and fixing in replacement to PG clamp suitable for ACSR for making inter connection on 33 KV net work complete all as specified and directed.
Supplying, straining and stringing in replacement of alumunium conductor steel reinforced (ACSR) in any specification making interconnection of net work fixing on existed structure/pole and replacement of unsv run of 11 KV over head line on existed poles complete all as specified and directed. (Note :- Sagging length of ACSR conductor shall be deemed included in the quoted unit rates).
M&L De-hydration/ filtration of transformer oil of transformer in site specification / make /model etc by hiring on line filtration plant to achieve di-electric strength not less than minimum 45 KV including cutting welding opening to body / re-assembling as same with other site work services as under:-(a) Removal of all suspended particles such as dust, rust, scales, collided carbon oxidation sludge etc upto < 1 micron. (b) De-hydration of transformer oil under vaccum (c) Circulation of heated oil and filling of treated oil in transformer tank. (Note :- (i) Contractor shall use the vehicle mounted filtration plant with new suitable size heavy duty hose pipe. (ii) The transformer oil required for replacing/ top up shall be measured and paid separately as " Supply only". (iii) conducting field testing of di-electric strength of the transformer oil before and after filtration. (iv) Checking the megger/ earth resistance values with battery operated megger for 5000 Ohm).
Supply and filling new Transformer oil having die electric strength not less than 45 KV in sealed container complete including centrifuging of oil (if required ) up to getting dielectric strength not less than 45 KV complete all as specified and directed. (Note : Transformer oil will be supplied by the contractor in sealed container of approved make alongwith necessary manufacturer test certificate and purchase vouchers Make: Power oil or Savita or equivalent make given in Appx 'B' duly approved by AGE (I))
M&L Rectifying and arresting the oil leakage of transformer of any capacity, disconnection of cable termination of HV& LV ends , opening the top cover by using tripod, chain and pulley after removing all fitments, replacing the components of the transformer such as gaskets, "O" rings etc. Rectify the leaks in a variety of areas such as radiator fins, flanges, circuit breakers, valves, fastener assemblies, Oil leakage through pin hole / crack joint , drain valve / radiator valve , Oil leakages through gasket joints. Applying putty/M-Sea Monoplast and gas welding where ever as required necessary complete all as directed by Engr-in-Charge & refixing the top cover and all fitments, re-fixing cable termination of the HV& LV ends complete all as specified and directed. (Note : Testing and Cost of all type of rubber gasket, "O" rings, putty/M-Seal Monoplast and gas welding where ever as required, lugs, nuts, bolts, double washers etc shall deemed to be included in the quoted unit rate).
M&L Over hauling & Servicing, testing, commissioning, re-setting (Earth fault protection, over-loading current & short circuit current) controlling relay of 33 /11 KV step down transformer rating/ capacity 1500 KVA controlling by SF - 6 in rating 630 Amps 33 KV - 01 No and as same controlling to 33 /0. 433 KV step down transformer rating/ capacity 63 KVA incl vacuum circuit breaker in rating 630 Amps 11 KV -06 Nos connecting with out going feeder (network) and interconnecting bus coupler located at 33 KVA MRS( Main receiving station) by engineer of government authorised agency with connecting protecting equipment as under: - (i) Different rated transformers controlled by SF 6 type RMU (Ring men unit) -15 Nos , , 630 Amps 11 KV rated (01 No as incomer and 02 Nos outgoing minimum ) controlling to AOR (Area of responsible) complete all as specified and directed. (Note: (i) Quoted rate shall be included to required minor spares for making serviceable. (ii) Duplicate copy of time setting test report of network shall be deposit by contractor in sub-divn for office record. (iii) Over hauling, servicing, testing & commissioning of 33/11KV step down transformer shall be carried out through authorised agencies as approved by AGE (I) only)
Labour for disconnecting/removing open to body , cutting, welding, bolting etc all as per site to defective unsv part/ spares of step down 11/ 0.433 KV transformer upto 400 KVA capacity after removing of HT/LT connections with earth strip in any specification/ manufacturer incl on requirement trainspotting from site to workshop and back safely , re-assembling the same, drain out oil and take safe custody for re-filling the same, taking out burn out core/ coil with insulating material , cleaning , removing to sludge / waste materials to prepare repainting on internal surface of tank etc incl other site works required to make serviceable complete all as specified and directed. (Note : (i) Quoted rate shall be included cost of required T&P, crane for loading & un-loading safely. (ii) Cost of damages during above job shall be born by the contractor.
Supply and re-filling to dehydrating agents (silica gel) re-filling in breather of transformer in any make model rating etc complete all as specified and directed.
Supply and fixing in replacement to cabin assembly of silica gel suitable for step down transformer 11/ 0.440 capacity upto 400 KVA including excess water storage bottle, clamp including silica gel filled etc in existing make model specification in all complete and directed. (Note : Quoted rates shall be including the cost of silica gel initially filling).
Supply and fixing in replacement to cabin assembly of silica gel suitable for step down transformer 33/ 11 KV capacity 1500 KVA including excess water storage bottle, clamp etc in existing make model specification in all complete and directed. Note : Quoted rates shall be including the cost of silica gel initially filling.
Supply and fixing in replacement to brass terminal studs with nuts, oil seal and washer for LV / HV side of step down transformer 11/ 0.440 capacity rage 300 KVA to 500 KVA including replacement of gasket etc to make transformer leak proof complete in existed make model specification etc all as specified and directed.
Supply and fixing in replacement to brass terminal studs with nuts, oil seal and washer for LV/ HV side of step down transformer 33/ 11 KV capacity rage 1500 KVA including replacement of gasket etc to make transformer leak proof complete in existed make model specification etc complete all as specified and directed.
M&L for re-winding to burn out LT/HT leg (all coil) of step down transformer capacity 100 to 250 KVA using super enameled copper wire with insulating material in same gauge copper purity, no of turns in coil with varnishing, heating, testing etc with all other site work required to make the transformer serviceable complete all as specified and directed. (Note: (i) Contractor shall inform to deptt for inspection/check burn out coil before re-winding and rewinding shall be done from OEM authorised work shop only as approved by Accepting Officer AGE (I) (ii) Make of copper winding : Devidayal or equivalent as approved by AGE (I)
M&L for earthing complete with galvanised cast iron earth plate of size 600 x600 x 6 MM thick burred directly in ground not less than 2.25 Mtrs below normal ground level, earth plate packed on all side with charcoal mixed wih salt to a thickness of 150mm connected by GI earth strip of size 32x6mm thick soldered and rivetted to earth plate including GI pipe 20 mm dia light grade 2.5 mtr long for watering and 40mm dia of bore for drawn through GI earthing strip including necessary earth work , chamber of PCC (1:4:8) type D2, RCC pit cover with 50 mm thick made out by (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm MS bar handle, funnel, wire mess, all as shown in electrical plate No 3 of MES sch part -I 2009 including testing on completion with satisfy value etc complete all as specified and directed. (Note: Quoted rate shall be included cost of required earth/brick /PCC work etc).
M/s NSA Engineering Corporation
A S ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .