Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.9 LAccepted-AOC FLAT NO 402 4TH FLOOR BLDG NO 31 HANSGEET CO OP HSG SOCIETY PANT NAGAR GHATKOPAR E MUMBAI 400 075 | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.0 L+₹4,915 (0.12%)Rejected-Finance 5 6 MINTO ROAD ALLAHABAD 211001 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L2 | Rejected-Finance Not Reasonable | |
| 3 | L3₹44.3 L+₹3.3 L (8.16%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Not Reasonable | |
| 4 | L4₹44.4 L+₹3.5 L (8.60%)Rejected-Finance T 16 1 SHETTY HOTEL OLD NAVY NAGAR COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance Not Reasonable | |
| 5 | L5₹44.5 L+₹3.6 L (8.73%)Rejected-Finance NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | L5 | Rejected-Finance Not Reasonable |
Tender Value
₹59 L
EMD Value
₹1.2 L
Closing Date
4 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Saurabh Gupta, EE
GE (W) Colaba, Mumbai
SPL REPAIRS TO BLDG NO P 4 (SINGLE ORs LIVING OTM ACCN) AT GRN BN UNDER GE (W) COLABA, MUMBAI
2022_MES_550529_1
8681/E8
Open Tender
Civil Works
Item Rate
180 days
GE (W) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE (W) Colaba, Mumbai
₹1.2 L
Yes
15 Oct 2022
7 Sept 2022
6 Oct 2022
7 Sept 2022
4 Oct 2022
21 Sept 2022
Amount
Dismantling Mangalore patteren or similar tiles in roofing including portions bedded in cement mortar all as specified and directed.
Dismantling roof tile battens of any description and in any position all as specified and directed.
Material and labour in repair to replace old decayed timber (including piecing, scarifying, etc of old and new timber if required) second class hard wood clean sawn in scantlings timber framed and fixed in any position and description including scafoldings of any hieght all as specified and directed.
Supplied and fixed in repairs to replace old or decayed boarding in patches including cutting out old,piecing, heading joints etc 20 mm thick second class hardwood clean sawn boarding fixed with nails with butt joints in any situation including scafoldings of any hieght all as specified and directed.
Fixing only in repairs in patches including cutting out old, piecing, heading joints etc 20 mm thick second class hardwood clean sawn boarding fixed with nails with butt joints in any situation including scafoldings of any hieght all as specified and directed.
M&L pre-painted roof metal sheet of Mangalore tile design profile hot-dip aluminium-zinc alloy metallic coated profile steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick of a colour having yield strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified including necessary scaffolding and safety measures at any height all as specified and as directed. Make:- Tata Steel/JSW colouron +/Treckdeck/CRIL/Essar steel(AM/NS).
Supply & fix Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPA as in roof coverings /claddings to wall, fixed with self tapping screws including scafoldings of any height all as specified and directed.
S & F hot rolled medium and high tensile structural steel of grade E 250 quality A conforming to IS 2062: 2011 as in joist, channel, angle, flat iron or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated) all as specified and as directed.
Demolition of cement concrete in ground floor and paving n.exc 15cm thickness (below or above ground level) and removing the demolished material and debris out side MD land all as specified and directed.
M&L 75 mm thick PCC 1:3:6 type C-2 ( using 40 mm graded crushed stone aggregate) as in plinth protection, flooring/subbase including necessary shuttering all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, & brushing neat cement slurry with 3.0 kg of cement per sq mtr etc. complete all as specified and directed.
M&L light shade vitrified coloured Ceramic tiles 10 mm thick (square/rectangular) polished area of each tile not exceeding 0.36 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of the tiles laid over and inluding screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes including dismantelling all as specified and directed.
M&L light shade vitrified coloured Ceramic tiles 10 mm thick (square/rectangular) polished area of each tile not exceeding 0.36 sqm in vertical surfaces such as skirtings and dados set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of the tiles laid over rendering 10 mm thick on fair faces of brick work in CM (1:4) including dismantelling all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to mirror finish laid over and inluding screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes including dismantelling all as specified and directed.
All as per Item No 14 above but in riser of steps, skirting, dado and pillar and jointed over rendering 10 mm thick on fair faces of brick work in CM (1:4) including dismantelling all as specified and directed.
Material and labour Granite (of any type and colour) 20 mm thick machine cut , bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid in steps/floors/Jambs/WHB conters and all other similar works in approved design laid over 20 mm thick screed bed in cement mortar 1:4 including dismantelling all as specified and directed.
Dismantling of ceiling board (plup insulation or insulation etc) or insulation board any thickness including cover fillet and grid frame work all as specified and directed.
M&L for powder coated /anodized aluminium snap grid having size 605mm x 605mm and sections incorporated in frame work shall conform to IS 733, IS 737 and IS 1285 and snap grid frame work shall be fixed to ceiling with supporting hanger 6mm dia mild steel rod, J bolts with necessary bolts, nuts and washers all as manufacturer instruction, the main & cross tees shall be jointed at junction/crossings with anodized aluminum angle bracket of size indicated it shall be 19.05mm x 19.05mm x 1.45mm, weighing 0.14 Kg per RM, fixed with suitable mild steel, bolts nuts and washer all as per manufacturers instruction, the snap grid shall be supported at ends all along the wall with anodized aluminum angle of size as indicated along if not indicated it shall be 38mm x 25mm x 2.18mm, weighing 0.358 Kg per running meter all as specified and directed.
M&L 8 mm thick exposed metal frame ceiling with calcium silicate board of siliceous and calcareous materials reinforced with cellulose fibre for fixing in 605 X 605 mm grids . Note:- Frame work for ceiling shall be measured and paid separately.
Taking down cement plaster of any description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water etc all as specified and directed.
M&L 15 mm thick cement plaster in CM (1:6) on brick work/ RCC wall and finish the surfaces fair and even without using extra cement all as specified and directed.
M&L rendering 15mm thick in cement mortar 1:4 using intergral water proofing compound on fair faces of brick work to be finished even and smooth (with out using extra cement all as specified and directed. Note: Integral liquid water proofing compound to be used in per bag of cement shall be as per manufacturers instructions and paid separately under respective items.)
Supply only liquid integral waterproofing compound
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 1mm thick (average) wall putty all as specified and directed.
Materials and labour for complete removal of existing treatment and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 1mm thick (average) wall putty all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of 100% exterior grade acrylic paint (wheather proof paint) over one coat of primer all as per manfacturers specifications all as specified and directed.
M&L for preparation of old plastered surfaces and applying two coats of 100% exterior grade acrylic paint (wheather proof paint) all as per manfacturers instruction/specifications all as specified and directed.
M&L for preparation of old painted wood or wood based surfaces, of any description, not otherwise described over 10 cm width or girth and apply one coat of synthetic enamel paint all as specified and directed.
M&L for preparation of new wood or wood based surfaces, of any description, not otherwise described over 10 cm width or girth and apply two coat of synthetic enamel paint over a coat of pink primer all as specified and directed.
Taking down Chowkhats or frames with shutters (without taking of shutters from the frame) area exc 1.50 but nexc. 4.00 Sqm each all as specified and directed.
Taking down shutters of any description area exc. 1.00 Sqm but nexc 2.00 Sqm all as spcified and directed.
S&F 2nd class hard wood plain solid straight chowkhat and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joint all as specified and directed.
M&L for preparation of wood and wood based materials new or old, of any description and girth, not otherwise described, and treating ends of posts, back of chowkhats etc. area tarred exc 0.1 sq m but n. exc. 0.5 sq m each and treated with tar or coal tar black paint all as specified and directed.
M&L for preparation of wood and wood based materials, new or old of any description and girth, not otherwise described, treating small articles such as holdfasts,end of posts, backs of chowkhats, etc area nexc. 0.1 sq m each and treated with tar or coal tar black paint all as specified and directed.
S&F 35 mm thick 2nd hard wood rail and style plain framed panelled shutters (any numbers of panels) with lock rail and panel of 9 mm thick B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part-I) kiln seasoned and chemically pressure treated all as specified and directed.
S&F 2nd class hard wood 35mm thick glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc. (without sash bars) edges of framing plain, chamfered or rounded, fittted with cut and mitred beads for securing gauge, etc sizes of member of shutter as specified SSR part-I Section 8 clause 8.24 (a) complete all as specified and directed.
S&F powder coated aluminium frame/shutters of any colour (minimum thickness of powder coating 50 micron) for doors/windows/ ventilators with one or more rebates including necessary joining cleats, glazing clips, rubber packing, locks, anodised alumnium snap beading, screws etc. complete all as specified and directed.
M&L 5.5 mm thick sheet glass, ordinary quality and glazing with aluminium beads and rubber gaskit in square exc 0.5 sqm in each pane frosted on one side all as specified and directed.
S&F Aluminum alloy anodised sliding door bolts of 300mm long with hasp stapple and fixed all as specified and directed.
Taking down shutters of any description and resucring or easing and refixing in same opening all as specified and directed.
S&F 30mm thick glazed & skelton, open rebated & prepared to receive glass/gauged etc divided in square with plain, chamferred or rounded mitred edges of framing plain, chamfered or rounded fitted with or without sash bars & metred beads for securing glass gauge etc size of members of shutters as specified in SSR Part-I section 8, clause 8.24(b) supplied & fitting to chowkats using 2nd class hard wood all as specified and as directed.
S&F 75 mm butt hinges medium weight cold rolled stainless steel all as specified and directed.
S&F aluminium anodised 100 mm barrel tower bolts of extruded section all as specified and directed.
S&F aluminium handle 75 mm cast type anodised all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square nexc. 0.5m in each pane all as specified and directed.
M&L stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden/ aluminium beadding all as specified and directed.
M&L in repairs stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or wooden/ aluminium beaddingall as specified and directed.
S&F 150mm long gate and shutter aluminum hook and eyes all as specified and directed.
S&F aluminium anodised 200 mm barrel tower bolts of extruded section all as specified and directed.
S&F aluminium handle 150 mm cast type anodised all as specified and directed.
S&F 100 mm butt hinges extruded aluminium alloy with galvanized mild steel hinges pin anodised type `C'-22 all as specified and directed.
M&L for gently clening the surfaces of the stone masonry and piers with specification water misting techniques employing air water jet using a fine nozzle sprinkling system calibration to spray fine mist along the stone surfaces without over wetting followed up by gentled surfactants and cleaning brushing with soft nylon brushes as specified, gentle surfaces cleaning may include using water misting amdmild Ph balanced surfactants as specified for indicated areas to remove surfces dirt grith surfaces accreeetions lime wash etc by means of water misting and Ph balances surfaces cleaning all as specified and directed. Note:- Quoted rate shall be inclusive of removing vegitation on wall surfaces, chajja etc and erection and dismantling of MS tubular double scaffolding up to 6 to 10 metre height and provision of necessary safety equipment to sklled works to carry out works.
M&L for raking out cement pointing or any other hard material used and careful repointing and repair to be carried of the damaged pointing to walls externally and internally above the base of vaults and apse domes with poor joints, in lime mortar 1:3 (1 lime , 3 sand mix to be approved by consultants before application) of size 50x15mm and filling in of any holes/damage area of stones that may have to be filled in lime mortar pointing to be carefully colour matched using additives such as kattha, sand stone dust and such additives to exactly preparation of batches of samples upto 20 samples of colour matched lime mortar for approved by Eng-in-charge. The contractor to ensure use of masking tapes and sharp specialized spatulae and tools to ensure clear lines and high level of workmanship on site all as specified and directed.
M&L for applying two coats of melamine polish on external wall clading after perpration of surface all as per manufacturers direction all as specified and directed by Engr-in-Charge
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces all as specified and directed
M&L for point wiring, in and including rigid non-metallic PVC casing capping, 19/ 20 mm dia suitable size, cutting chases for sinking for concealed boxes for wiring with 1.5 sqmm FRLSH PVC insulated, unsheathed, multi stranded copper conductor cable single core, 1100 volts grade with flush type metal boxes suitable for fixing switches, sockets and fan regulator etc., white or any colour cover plate with brass screws and cup washers including PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm as an earth wire connected to common earth and earth dolly as per IS specification and as specified in SSR Part-I for one light point / wall fan point / exhaust fan / bell point controlled by one switch.
All as per serial item No 56 above but for one ceiling fan controlled by one switch & regulator
All as per serial item No 56 above but for One 3 pin socket point 5 Amps on independent board
All as per serial item No 56 above but for One 3 pin socket point 5 Amps on same board
All as per serial item No 56 above but for one socket point 15 Amp with 2.5 sq mm PVC unseathed FRLSH wire along with 2.5 sq mm green colour wire as earth contuinity conductor connected to common earth dolly all as specified & directed.
S&F Switch piano, flush type single pole, one way 5 Amp all as specified & directed. Make: Anchor, Fine, SSK
S&F Switch piano, flush type single pole, one way 15 Amp all as specified & directed. Make: Anchor, Fine, SSK
S&F socket 2/3 pin 5 Amps all as specified & directed. Make: Anchor, Fine, SSK
S&F socket 6/16 A 2/3 pin all as specified & directed. Make: Anchor,Fine,SSK
S&F stepped type electronic fan regulator 450 watt flush type on the existing phenolic laminated sheet all as specified & directed. Make: Anchor, Fine, SSK
S&F ceiling rose surface bakelite 65 x 50 mm two to three terminals all as specified and directed. Make: SSK,Anchor,Kinjal,Fine
S&F in repair 20 watt LED fitting , 4 feet long fixed on PVC square for mounting the fittings and electrically connecting with three single core 23/0.0076. PVC insulated multi strandard copper flexible cable from ceiling rose to light fitting (connector block of lamp fitting) and one for earthing all as specified and directed. Make: Havells cat pt no LHEXBXPNIN1W020 equivalent model in Wipro model no - Wipro Garnet 20 W LED Batten 6500K / Philips model No - BN150W LED 20S-6500 PSE ODGR / OSRAM.
S&F in repair LED building security light fitting 45 watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency minium 100 luman per watt after all losses, pressure die-cast aluminium housing LED street light complete with GI clamp including connected accessories and bracket made of GI pipe 40mm dia light grade 1.25 m long, bend to shape with two sets of MS flat iron clamps, nuts, bolts, washers etc. complete all as directed by Engineer-in-Charge. Make Philips : cat pat No BRP409LED060HENRPC S1PSU GR or equivalent in Wipro cat part No LR02-501-XXX-57-XX / havells cat part No ENDURACITYLITEPLATPLUSSL45WLED757SASYBOPC
Taking down carefully copper/aluminum submain wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc all as specified and directed
S&F sub main wiring with two run of 6 sqmm stranded copper conductor FRLSH wire with one run of 6 sqmm stranded copper conductor as earth continuty conductor connected to common earth dolly including PVC FR heavy duty conduit of adequate size (not less than 25 mm dia) for housing the wires for one AC point all as specified and directed Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Mode of measurement shall be two runs of 6 sqmm cable and one run of 6 sqmm cable with PVC conduit shall be measured as one length.
S&F in repair MCB SP 240 volt, 6 to 40 Amps all as specified and directed.
S&Fin repairs MCB SPN 240 volt, 40 Amps all as specified and directed.
S&F in repairs sheet metal enclosures for DB, double door, when MCBs to be used 240 volts 12 way with 200 Amps rated bus bar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection all as specified and directed.
S&F in repair rotational moulded polythene water storage tank of 2000 litres capacity triple layered ISI marked of cylindrical/cubical vertical/horizontal shape with closed top cover of casted iron (BMC approved pattern) complete hoisted with inlet and outlet & overflow connection including FRP Lid cover complete fixed with screw and fixed in position & connecting up all as directed and specified. Make: Sintex/Infra
S&F GI tubing 15 mm dia medium grade ISI marked with all fittings and fixed to walls and ceiling or laid in floor for any grade including provision of fittings and accessories wooden support and clamps walls/roof all as specified and directed. Make:- Tata/ Jindal/ GST
S&F GI tubing 25 mm dia medium grade ISI marked with all fittings and fixed to walls and ceiling or laid in floor for any grade including provision of fittings and accessories wooden support and clamps walls/roof all as specified and directed. Make:- Tata/ Jindal/ GST
S&F in repair bib cock, cast copper alloy chromium plated with butterfly handle screwed fancy type both ends for GI tubing 15 mm dia including necessary clamp & saddles all as specified and directed.
S&F in repair new gun metal globe valve with iron wheel head 15 mm dia screwed both ends for iron pipe and fixed all as specified and directed.
S&F in repair new gun metal globe valve of with iron wheel head 25 mm dia screwed both ends for iron pipe all as specified and directed.
S&F in repair health faucet Jet spray cast copper alloy chromium plated with cast copper press knob and 1.5 mtr Extensive pipe cromium plated double locked antirust twist type all as specified and directed Make : Prayag/Jaguar
Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6.3 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level, connected to 4 mm dia GI wire as earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber, MS funnel, wire gauge. CI cover with frame, 15 mm dia GI pipe light grade for protection of wire etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land, filling of charcoal and salt all as shown in electrical plate No. 5 of MES Sch Part I , connected to earthing test point all as specified and directed testing on completion.
Frends Enterprises
S S ENTERPRISES
Shetty Construction Co
ASHOK CONSTRUCTION
Vandan Enterprises
Unitech Enterprises
SHREE JAGDISH FURNITURE CO.
SN CONSTRUCTION
Nilesh Construction
Bidder Name
Unitech Enterprises
Frends Enterprises
Nilesh Construction
Shetty Construction Co
RAMESH ENTERPRISES
S S ENTERPRISES
ASHOK CONSTRUCTION
SN CONSTRUCTION
Vandan Enterprises
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .