| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹48.4 L+₹1.7 L (3.61%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹49.6 L+₹3.0 L (6.32%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹49.7 L+₹3.0 L (6.52%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹49.8 L+₹3.2 L (6.75%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹48.2 L
EMD Value
₹96,360
Closing Date
23 Mar 2024, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
SPECIAL REPAIRS TO POWER SUPPLY OF OVERHEAD NIGHT LUMINARIES FROM REAR GATE TO 33KVA MRS AND OTHER E/M SERVICES INSIDE RESTRICTED AREA UNDER GE(I) RND KBAGH
2024_MES_645313_1
8737/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE I R and D Kanchanbagh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹96,360
Yes
16 Apr 2024
6 Mar 2024
26 Mar 2024
6 Mar 2024
23 Mar 2024
18 Mar 2024
6 Mar 2024 - 13 Mar 2024
Amount
Material and labour for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 metres long)
Erection of metallic pole of 8.5 m length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation, refilling, removal and coping around steel tubular pole with 30 cm x 30 cm x 20 cm size etc. all as specified and directed by Engr -in- Charge.
S & F in Light grade 50 mm dia GI street light with 4 feet mast arm for poles SP-25 to SP-31 as per the site requirements fixing on top of the pole with necessary nuts and bolts including the bracket and connecting up with three core flexible cable by making necessary holes on poles complete for passing the copper cable concealed in the pole including removing of spikes installed on pole complete all as specified and directed by the Engr- in - charge.
S&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty),ISI Marked, IS:7098 Part-I, with aluminium conductor, LT 1100 volts grade of cross sectional area 4 core 35 sq. mm, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, complete all as specified and directed as per site requirement specified and directed by Engr in charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, tubular poles or laying of pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil, including trimming sides of foundations and forming bottom surface to required level, complete all as specified and directed by engr in charge.
M & L Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed . NOTE:- Punned thickness shall only be measured and paid.
Supply and laying common burnt clay building bricks, sub-class grade "B" designation 75 Old size bricks all as specified and directed by Engr in charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm all as specified and directed by Engr in charge.
Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed by Engr in charge.
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and drawing 3 core 1.5 sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
S&F LED street light, 90 Watt, with aluminium pressure die-cast housing, high purity PC Fresnel diffuser with silicon gaskets for IP-65 protection, power consumption less than or equal to 90 W and luminaire lumen greater than or equal to 7000lm in built electronic driver prewired upto terminal block, colour temperature 5700K, surge protection in CM-3.5KV, constant current-constant voltage operated driver with range 150-270V AC including connecting with 3 core PVC copper cable 1.5 sqmm drawn through the bracket and all spares required at site complete all as specified and directed. Make:- Havells / Crompton /Bajaj / Jaquar / Polycab / Shakthi or its equivalent
S&F PVC Junction box of size 250 mm x 250 mm x 160 mm consisting of 02 Nos of aluminium bus bars on insulators, MCB SP 6Amp - 01 No., with locking arrangement and provision of cable entry and exit PVC glands complete all as specified and directed.
Supply and Fix Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 25x20cm size
Supplying and laying of 63 mm size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
Material and Labour for cutting existing road/PCC of size 45cm x 60cm for taking out/laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type CL using 20mm graded aggregates complete all as specified and directed
Supply & fix Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. complete all as specified and directed.
M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised iron 32 x 6 mm strip as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed.
Providing and fixing 25 mm X 5 mm GI strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Dismantling of ACSR conductor and insulators from 35 Nos of pole complete
SUN LIGHT HOUSE
SRI SAI ENTERPRISES
MVS ENTERPRISES
M/S PAVANI ENTERPRISES
S.S.ENGINEERING CORPORATION
Venkat Sai Enterprises
sri vishnu enterprises
Anjana corporation
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .