Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.9 L+₹32,091.16 (3.02%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹11.0 L+₹40,523 (3.82%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹11.2 L+₹58,393 (5.50%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹11.4 L+₹76,078 (7.17%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹13.5 L
EMD Value
₹27,000
Closing Date
4 Feb 2020, 3:00 pmClosed
Lt Col PK Morolia
GE (AFA) Hyderabad, Pin- 500043
PROVISION OF DEDICATED UG CABLE AND ALLIED WORKS FOR CEO COMPLEX AND CERTAIN E M MINOR WORKS AT AFA HYDERABAD
2020_MES_312769_1
8958/12/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AFA) Hyderabad
As per Tender Documents
5 documents required · 5 mandatory
₹500
Yes
GE (AFA) Hyderabad
₹27,000
Yes
22 Apr 2020
8 Jan 2020
5 Feb 2020
8 Jan 2020
4 Feb 2020
21 Jan 2020
8 Jan 2020 - 11 Jan 2020
Amount
NOTE FOR BOQ :- Bidders may please be note that certain items of this BOQ are same, hence you are requested to quote the same rates for those items which are same description otherwise lowest quoted rate for those items will be considered for payment purpose and no further claim shall be entertained in this regard.
Provision of dedicated Cable for CEO Complex at AFA Hyderabad :- Excavation in trenches in hard / dense soil not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables complete all as specified and as directed.
M&L for River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punned thickness up to 18 cm and consolidation, complete all as specified and as directed. Note :- Punned thickness only will be considered for payment.
Returning, filling in trenches in any kind of soil in layers not exc. 25 cm after laying of cables including spreading, levelling, watering and well ramming complete all as specified and as directed.
M&L for bricks sub class B locally available best quality laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed
M&L for Boring of holes under road, pavement hard standing by using trenchless technology using ultrasound technique and necessary machine to insert pipe of 100 mm light grade GI pipes with all fittings such as bends, elbows, Tees, etc, for protection of cable complete including all plant & machinaries, alongwih Butt fusion welding machine with all accessories, T&P etc required all as specified and as directed. Note :- Protection pipe will be measured and paid separately.
M&L for light grade galvanized pipe ISI marked with all fitting aid in trenches, under road or fixing on wall / pole / crossing nallah etc of bore 100 mm complete all as specified and as directed .
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 240 sqmm 3.5 core complete all as specified and as directed.
Supply and fix On Load Change Over Switch 250 Amps, front operated, open execution type 4 pole, 50 Hz ,415 V and including suitable size MS sheet (2.0mm) mounting box painted with powder coated paint at the tapping point including connection of both incoming & outgoing cables complete all as specified and as directed. Make :- L&T / Standard / Schneider / Legrand
Provision of Submersible Pump for overhead filling at safety Bay :- Sppuly, Install, Testing and Commissioning of open well submersible mono block pump set, electric driven 415 V, 65 mm suction, 50 mm delivery, 7.5 HP, 2900RPM complete all as specified and as directed. Make :- Kirlosker Model No KOS/858+ or Equivalent approved make in Crompton / CRI
Supply & Fix direct on line starter 7.5 HP , 13 TO 22 Amp MK I DOL complete all as specified and as directed. Cat No- SS96228 Make L&T or equivalent approved make
Supply & Fix Sumersible cable 6 Sqmm 3 Core PVC insulated 1100 Volts grade complete all as specified and as directed.
Supply & Fix GI Tubing 50 mm dia medium grade with all fitting and fixture complete all as specified and as directed.
PROVISIONING OF 5 AMP SOCKET(QTY 02 ) 15 AMP SOCKET(QTY 02 AND WALL MOUNTED FANS QTY 02) FOR NEW ADVANCE STUDIO LIGHT SYSTEM :- M&L for sub main wiring with two runs of 1100 volt grade 6.0 sq.mm. (nominal area) single core FRLS Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and rigid non-metallic PVC conduit suitable size with all necessary fittings, surface in walls / roof / floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and as directed.
Note : (I) Three runs of wire and one run of conduit with necessary accessories will be measured as one unit length.
(II) The wiring shall be done strictly as per IS standards.
M&L for Point wiring complete as specified with 1100volt grade 1.5sq.mm. (nominal area) single core FRLS Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and surface type of rigid non-metallic PVC conduit suitable size, with all fittings including terminal boxes made out of MS sheet metal switch boxes fixed on wall for housing of 5 Amps Switch Socket Combination duly earthed with same size cable as for line conductors as used in the wiring but green in colour as continuous earthing wire complete all as specified & directed .
Note The wiring shall be done strictly as per IS standards.
M&L for Point wiring complete as specified with 1100volt grade 2.5sq.mm. (nominal area) single core FRLS Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and surface type of rigid non-metallic PVC conduit suitable size, with all fittings including terminal boxes made out of MS sheet metal switch boxes fixed on wall for housing of 15 Amps Switch Socket Combination duly earthed with same size cable as for line conductors as used in the wiring above but green in colour as continuous earthing wire complete all as specified and as directed.
Note The wiring shall be done strictly as per IS standard.
S&F Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 and 15 Amps flush type universal complete all as specified and as directed.
S&F Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 Amps flush type universal complete all as specified and as directed.
S&F MCB DB SPN 6 way with copper bus bar & neutral link double door type to be fixed in the wall including connections complete all as specified and as directed.
S&F MCB SPN 6 to 32A, 10 KA rupturing capacity complete all as specified and as directed.
S&F Fix MCB SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed.
Supply and fix wall mounting fan 400 mm sweep with inbuilt speed regulator, complete all as specified and as directed.
PROVISIONING OF QTY 04 THREE PHASE POWER SOCKET FOR OPERATION OF AIRCRAFT WASHING IN TMS 03& 04 :- M&L for sub main wiring with four runs of 6 Sq mm ingle core PVC insulated unsheathed cable 1100 Volts grade multi stranded with copper conductor drawn through and including suitable size steel conduit and conduit accessories duly fixed on the steel girder / channels welding with suitable MS brackets including one run of 6 sq mm copper earth continuity wire Note:- (i) Four runs of copper conductor and one run of 6 sq mm copper earth wire including conduct shall be measured and paid as one unit length only (II) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.complete all as specified and as directed.
S&F Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB TP 32 Amp 415 V, 50 Hz, AC complete all as specified and as directed.
PROVISIONING OF WALL MOUNTED FAN INSIDE PARKING BAYS AT SAFETY BAY INSIDE PARKING OF CFTS :- M&L for sub main wiring with two runs 1100 volt grade 6 sq.mm. (nominal area) single core FRLS Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and rigid non-metallic PVC conduit suitable size with all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and as directed.
Note : (I) Three runs of wire and one run of conduit with necessary accessories will be measured as one unit length.
(II) The wiring shall be done strictly as per IS standards.
M&L for Point wiring complete as specified with 1100volt grade 1.5sq.mm. (nominal area) single core FRLS Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and surface type of rigid non-metallic PVC conduit suitable size, with all fittings including terminal boxes made out of MS sheet metal switch boxes fixed on wall for housing of 5 Amps Switch Socket Combination duly earthed with same size cable as for line conductors as used in the wiring above but green in colour as continuous earthing wire complete all as specified and as directed.
Note:- (i) The wiring shall be done strictly as per IS standards.
S&F Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 Amps flush type universal complete all as specified and as directed.
S&F of MCB DB SPN 6 way with copper bus bar & neutral link double door type to be fixed in the wall including connections complete all as specified and as directed.
S&F of MCB SPN 6 to 32A, 10KA rupturing capacity complete all as specified and as directed.
S&F MCB SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed.
Supply and fix wall mounted fan 400 mm sweep with inbuilt speed regulator, complete all as specified and as directed.
Provision of desert cooler (qty 04) and pedestal Fans (qty 04) at MTR&S :- M & L point wiring complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLS PVC insulated , unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC conduit of size not less than 20mm dia, with all with all necessary PVC, rigid, concealed type junction boxes for identifying junctions & PVC dummy plates etc. as required on site, concealed in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly including 1.6mm thick fabricated MS sheet terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with 3 mm thick laminated sheet complete all as specified for One three pin socket 5 Amps plug point independent complete all as specified and as directed.
S&F Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 Amps flush type universal complete all as specified and as directed.
Supply & fix Pedestal fans 230 volts single phase oscillating type 450 mm sweep with inbuilt 3 speed regulator including adjustable height and strong streamlined pedestal for greater stability complete all as specified and as directed.
Suply and fix desert cooler electric driven single phase having nominal air flow 4000 cum per hour plastic body TANK CAPACITY 50 TO 88 Ltrs complete all as specified and as directed.
PROVN OF EXHAUST FAN IN UPS ROOM ( 2ND FLOOR) AT GT facility :- M&L for Point wiring complete with 1.5 sqmm single core FRLS grade 1100 V PVC insulated unsheathed wire with multi stranded copper conductor drawn through in and including PVC casing & capping and accessories ISI marked fixed surface on wall / ceiling / roof etc and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor etc, for One exhuast fan point controlled by one piano switch complete all as specified and as directed.
Supply and fixing switch piano flush button single pole one way 5 Amp complete all as specified and as directed.
S&F Ceiling rose, PVC / polycarbonate, insulated body, 3 terminals and 240 Volts ISI marked complete all as specified and as directed.
Supply & Fixing exhaust fan with louvers 450 mm sweep, 1440 RPM, Heavy duty single phase 240 Volts, AC 50 Hz and connecting up including louvers and making good with matching colour with the surroundings provision of cable 3 core of size 0.5 Sqmm (16/0.2 mm) from ceiling rose to fan , including making necessary opening on stone /brick masonry wall and complete all as specified and as directed.
S & F DB with sheet metal enclosure 240 volts, 4 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete. (NOTE :- Distribution Board shall be fitted out side of the explosive store) complete all as specified and as directed.
S & F MCB SPN of 240 Volts, AC, 50 Hz of capacity 6-32 Amp 10 KA complete all as specified and as directed.
S&F MCB 'C' series SP 6-32 Amps rating, 10 KA breaking capacity, 240V, 50Hz, AC supply, complete all as specified and as directed.
M&L for Sub Main wiring with 2 runs of FRLS grade 1100 volt unsheathed PVC insulated cable of single core 2.5 sq mm (nominal area) multi-stranded copper conductor drawn through and including PVC Cassibg and capping of suitable size (ISI marked) incl all specials like joint elbow, Tee, junction , bend etc and provision of one run of FRLS grade 1100 V rated PVC insulated multistranded copper conductor single core 2.5 sq mm for earth continuity complete all as specified and as directed.
Note (I): Necessary M.S junction boxes for inspection as required on site/directed by Engr-in-charge, shall deemed to be included in the quoted rate.
(II) Three runs of wire and one run of conduit with necessary accessories will be measured as one unit length.
(III) The wiring shall be done strictly by following proper colour coding as per IS
PROVN OF 02 Nos 5 AMPS and 02 Nos of 15 Amps combined socket with switch to room No- 208( 2nd Floor) GT Faculty PC Lal Block :- M&L for sub main wiring with 02 runs of 1100 volts grade 6sq.mm. (nominal area) single core FRLS Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including rigid non-metallic PVC conduit suitable size with all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and as directed.
Note : (I) Three runs of wire and one run of conduit with necessary accessories will be measured as one unit length.
(II) The wiring shall be done strictly by following proper colour coding as per IS
M&L for Point wiring with 1100volt grade 1.5sq.mm. (nominal area) single core FRLS Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and surface type of rigid non-metallic PVC conduit suitable size, with all fittings including terminal boxes made out of MS sheet metal switch boxes fixed on wall for housing of 5 Amps Switch Socket Combination duly earthed with same size cable as for line conductors as used in the wiring above but green in colour as continuous earthing wire complete all as specified and as directed.
Note The wiring shall be done strictly as per IS standards.
M&L for Point wiring with 1100volt grade 2.5sq.mm. (nominal area) single core FRLS Grade PVC insulated unsheathed cable multi-stranded copper conductor drawn through and surface type of rigid non-metallic PVC conduit suitable size, with all fittings including terminal boxes made out of MS sheet metal switch boxes fixed on wall for housing of 15 Amps Switch Socket Combination duly earthed with same size cable as for line conductors as used in the wiring above but green in colour as continuous earthing wire complete all as specified and as directed.
Note The wiring shall be done strictly by as per IS
S&F Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and as directed.
S&F Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 flush type universal complete all as specified and as directed.
S&F MCB DB SPN 6 way with copper bus bar & neutral link double door type to be fixed in the wall including connections complete all as specified and as directed.
S&F MCB SPN 6 to 32A, 10KA rupturing capacity complete all as specified and as directed.
S&F of Fix MCB SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed.
Provision of Digital HT Load Monitoring Device at MRS :- Supply installation and commissioning of Maximum Demand Controller in existing HT LBS (Load breaker switch) panel, complete as directed by Engr-in-Charge. The controller shall be comprising of the following :- (a) MD Controller 6000 Series - 01 No (Make L&T) (b) Hooter - 01 No (Make L&T) (c) Power contactor MNX 9 - 01 No (Make L&T) (d) Auxilary Contactor - 01 No (Make L&T)
Excavation in trenches hard / dense soil not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables complete all as specified and as directed.
M&L for River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punned thickness up to 18 cm and consolidation, complete all as specified and as directed. Note :- Punned thickness only will be considered for payment.
Returning, filling in trenches in any kind soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, and well ramming complete all as specified and directed.
M&L for brick sub class B locally available best quality laid in trenches above sand cushioning for cable protection complete all as specefied and directed.
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 4.0 sqmm 2.0 core complete all as specified and as directed
PROVN OF EXHAUST FAN IN UPS ROOM ( 2ND FLOOR) AT ATCOTE BUILDING :- M&L for Point wiring complete with 1.5 sqmm single core FRLS grade 1100 V PVC insulated unsheathed wire with multi stranded copper conductor drawn through in and including PVC cassing & capping and accessories ISI marked fixed surface on wall / ceiling/ roof etc and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor etc, complete all as specified (a) One exhuast fan point controlled by one piano switch
Supply and fixing switch piano flush button single pole one way 5 Amps complete all as specified and as directed.
S&F Ceiling rose, PVC/polycarbonate, insulated body, 3 terminals and 240 Volts ISI marked complete all as specified and as directed.
Supply & Fixing exhaust fan with louvers 450 mm sweep, 1440 RPM, Heavy duty single phase 240 Volts, AC 50 Hz and connecting up including louvers and making good with matching colour with the surroundings provision of cable 3 core of size 0.5 Sqmm (16/0.2 mm) from ceiling rose to fan , including making necessary opening on stone /brick masonry wall and complete all as specified and as directed.
S & F DB with sheet metal enclosure 240 volts, 4 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete all as specified and as directed. (NOTE :- Distribution Board shall be fitted out side of the building)
S & F MCB SPN of 240 Volts, AC, 50 Hz of capacity 6-32 Amp 10 KA complete all as specified and as directed.
S&F MCB 'C' series SP 6-32 Amps rating, 10 KA breaking capacity, 240V, 50Hz, AC supply, complete all as specified and as directed.
M&L for Sub Main wiring with 2 runs of FRLS grade 1100 volt unsheathed PVC insulated cable of single core 2.5sq mm (nominal area) multi-stranded copper conductor drawn through and including PVC casing and capping of suitable size (ISI marked) including all specials like joint elbow, Tee, junction , bend etc and provision of one runs of FRLS grade 1100 Volts rated PVC insulated multistranded copper conductor single core 2.5 sq mm for earth continuity complete all as specified and as directed.
Note (I): Necessary M.S junction boxes for inspection as required on site/directed by Engr-in-charge, shall deemed to be included in the quoted rate.
(II) Three runs of wire and one run of conduit with necessary accessories will be measured as one unit length.
(III) The wiring shall be done strictly by following proper colour coding as per IS
KOGANTI CONSTRUCTION COMPANY
K LAKSHMAN SINGH AND CO
OM SAI POWER SYSTEMS
Srinivasa Consructions
POWER CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .