Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 CrAccepted-AOC | ₹3.7 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹3.9 Cr+₹21.8 L (5.95%)Rejected-Finance | ₹3.9 Cr+₹21.8 L (5.95%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹3.9 Cr+₹21.8 L (5.95%)Rejected-Finance | ₹3.9 Cr+₹21.8 L (5.95%) | L3 | Rejected-Finance Rejected |
| 4 | L4₹3.9 Cr+₹25.2 L (6.88%)Rejected-Finance B 2 46 SECTOR 18 ROHINI DELHI 110089 | NORTH WEST | DELHI | 110089 | ₹3.9 Cr+₹25.2 L (6.88%) | L4 | Rejected-Finance Rejected |
| 5 | L5₹3.9 Cr+₹27.8 L (7.58%)Rejected-Finance | ₹3.9 Cr+₹27.8 L (7.58%) | L5 | Rejected-Finance Rejected |
Tender Value
₹4.2 Cr
EMD Value
₹8.4 L
Closing Date
25 May 2021, 3:00 pmClosed
CCE(RND)SOUTH
PB NO. 1569 Akbar Road Secunderabad - 03
PROVISION OF CIVIL WORKS FOR DESIGN AND TESTING CENTRE FOR SINT(M) AT RCI, HYDERABAD
2021_DRDO_627649_1
83595/CIV/SINTM/CON
Limited
Civil Works
Item Rate
365 days
RCI
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
CCE(RND) Secunderabad
₹8.4 L
Yes
13 Aug 2021
22 Apr 2021
26 May 2021
22 Apr 2021
25 May 2021
4 May 2021
23 Apr 2021 - 3 May 2021
Amount
SUB HEAD-1 - BUILDING INCLUDING INTERNAL SERVICES SUB HEAD-I - EARTH WORK & ANTI-TERMITE TREATMENT
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge:
All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Ordinary rock
Hard rock (blasting prohibited)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m
All kinds of soil
Pipes, cables etc, not exceeding 80 mm dia.
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Supplying chemical emulsion in sealed containers including delivery as specified.
Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
SUB HEAD-II - REINFORCEMENT AND PLAIN CEMENT CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).
1:4:8 (1 Cement : 4 coarse sand(Manufactured) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (Manufactured): 4 graded stone aggregate 12.5mm nominal size) including applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
Extra for shuttering in circular work (20% of respective centering and shuttering items)
Weather shade, Chajjas, corbels etc., including edges
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).
All works upto plinth level
All works above plinth level upto floor V level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
All works upto plinth level
All works above plinth level upto floor V level
Add for using extra cement in the items of design mix over and above the specified cement content therein.
SUB HEAD-III - BRICK & STONE WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Deduction for using manufactured sand in random rubble masonry instead of river sand.
SUB HEAD-IV - STEEL & WOOD WORK
Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards,lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
Profile C
Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat.Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames.
30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including Patch Lock with strike plate having 3Nos high securty computer keys make ozone/Enox at Bottom and 600 mm length providing stainless steel brush finished handles of 25mm dia both side on each door and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing 1mm thick M.S. sheet door with frame and diagonal braces of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners including angle iron frames for doors 60x60x6 mm with M.S. butt hinges, ISI marked oxidised M.S. sliding door bolts of size 300x16 mm on both side all necessary fittings complete, including applying a priming coat of approved steel primer.
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes shall be paid separately)
Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm)
Float glass panes
4 mm thick glass pane (weight not less than 10 kg per sqm)
Extra for providing etched glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
Providing and fixing aluminium door fittings, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
300x16 mm sliding door bolts
300x10 mm tower bolts
200x10 mm tower bolts
Pull bolt lock
125 mm handles.
Hanging floor door twin rubber stopper
Rubber wall buffer for doors of size 50mm. Long.
Extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates,Grill and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge.
The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately.
The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025.
Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr
Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml.
Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml
Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm
Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to be conducted on site.
Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.
(Payment for fixing of IGU Panels in the curtain glazing is included in cost of Sr. No. 4.185)
For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin-Charge.
Providing and fixing glass reinforced concrete pattern, design thickness and color of M\S (G.R.C) Screens in approved size, UniStone make or equivalent, The Screens be made ’53 grade’ White Portland cement manufactured by JK Cement’ or equivalent, Quartz, fine silica sand, alkali resistant glass fiber manufactured by Saint Gobain’ or equivalent , super plasticizers manufactured by BASF or equivalent polymers manufactured by ‘BASF’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by BAYFERROX (Germany), or equivalent. The material casting should take place in synthetic rubber/ FRP Mould manufactured by ‘Reckli’ or equivalent. The fixing or screens should be dry fixing i.e. to be done with stainless steel ‘L’ shaped clamps, dash fasteners and pins.
SUB HEAD-V - PLASTERING & FINISHING WORK
6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams.
12 mm cement plaster of mix :
1:6 (1 cement: 6 fine sand (Manufactured))
12 mm cement plaster finished with a floating coat of neat cement of mix :
1:3 (1 cement: 3 fine sand (Manufactured))
1:4 (1 cement: 4 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:6 (1 cement: 6 fine sand (Manufactured)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand (Manufactured)) finished rough with sponge including waterproofing material as per manufacturer specification.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
New work (two or more coats) white cement based putty of average thickness 1 mm and including water thinnable priming coat with cement primer
Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
White washing with lime to give an even shade :
New work (three or more coats)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
French spirit polishing :
Two or more coats on new works including a coat of wood filler
SUB HEAD-VI- FLOORING WORK
Providing and laying double charged vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Providing and laying Vitrified tiles dubble charged in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 600x600 mm
Providing and laying antiskid rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand (Manufactured)), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately).
(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Supply and installation of vinyl sheet flooring, 2 metre wide and over all thickness of 2mm. The thickness of wear layer would be 2mm. The product should be homogeneous and single layered. The wear surface shall consist of impregnated polyurethane homogeneou smixture of PVC with TRUESHIELD technology,Plasticizers with out DOP, Urethane, color pigments and filler calendered to form a sheet. Color and pattern details shall be dispersed through out the thickness of the wear layer. It shall conform to group "T" wear resistance as per EN649, Clean Room certified with class'A' as per ASTMF 5100, Flammability resistance of class Bfl- s1 as per GB8624-2006, Dynamic coefficient of friction of class DS as per EN13893, Thermal Resistance of 0.072m2K/W as per EN12667, Thermal conductivity of 0.071W/mK as per EN12524, impact sound reduction of 3dB as per ISO10140, Slip Resistance of class R9 as per DIN51130, Residual indentation of 0.03mm as per GB/T4085-2005, Color fastness rating of ≥6 as per ISO105-B02, total weight being 2.8kg/m2 as per EN430.
The product shall be suitable for applications in class 23/34/43 are as as per EN685. Product shall exhibit antistatic behaviour , resistance to bacteria, resistance to chemical, resistance to staining, suitability to castor chair. Installation-It is important to ensure the sub floor on which the sheet is being laid is smooth, flat, hard and free from moisture, grease etc. In case of unevens ub floor the same should be levelled using self leveling compound. IPS/ Vitrified/ ceramic/ mosaic tiles do not provide zero leveled sub floor. The moisture present in the sub floor should be less than 8% before installation of the floor. The sheet should be installed as per recommended adhesive. The installation shall be undertaken as per manufacturers installation instructions.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
18 mm thick
Providing and fixing glass strips in joints of terrazo/ cement concrete floors.
40 mm wide and 4 mm thick
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand (Manufactured) : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Granite Stone of approved shade
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand (Manufactured) ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand (Manufactured)) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :
Approved colour and shade marble
18 MM. thick polished grenite stone work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand (Manufactured) ) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand (Manufactured)), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite of any colour and shade
Area of slab over 0.50 sqm
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
SUB HEAD-VII - MISCELLANEOUS WORK
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:
Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.
IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.
IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.
IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand (Manufactured)) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand (Manufactured) ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.
Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand (Manufactured)) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm
interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’.
The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge.
With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6)
Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm
and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :
GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes with unplasticised - PVC moulded fittings/ accessories,pipe clips etc. conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
(i) Single socketed pipes
110 mm diameter
Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge.
SUB HEAD-VIII - INTERNAL WATER SUPPLY & SANITARY INSTALLATIONS WORK
Providing and fixing white vitreous china wall mounting water closet of size 570x340x360 mm of approved shape including providing & fixing PVC concealed cistern of Size 460x450x80mm with dual flush plate fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc including painting of fittings and cutting and making good the walls and floors wherever required : complete.make Hindware cat Nos-92097
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-
White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and .
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm. make JAQUAR ACN-1111N or eqv.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineerin- charge.
Providing and fixing soap Dish Holder with concealed fitting arrangements.Make Jaquar ACN-1131N or eqv.
Providing & fixing CP brass Health faucet with PVC Flexible Tube with wall hook.( JAQUAR MODEL NO-573 or Equilent.)
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing toilet paper holder :
C.P. brass
Providing and fixing unplasticised Polyvinyl Chloride (UPVC) pipes, having thermal stability for hot & cold sewage supply including all UPVC plain fittings This includes jointing of pipes & fittings with one step UPVC solvent cement, & testing of joints complete as per direction of Engineer in Charge.Toilet Sanitary pipe work
100 mm nominal inner dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore
32 mm nominal bore.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
25 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Circular tank
SUBHEAD-IX INTERNAL ELECTRIFICATION
Wiring for light point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy class FRLS PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc as required.
Group-C
Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of 1.5 Sq.mm FRLS insulated multistranded Copper wires, run in & including 25mm dia, 2mm thickness FRLS PVC ISI mark conduits concealed in wall after necessary chase cutting with finishing/surface in wall / ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI Switch box with modular switch and the box covered with front plate.
Two Lights point controlled by one 6A switch.
Four Lights point controlled by one 6A switch.
Exhaust fan point controlled by one 6A switch including ceiling Rose.
One ceiling fan point controlled by one 6A switch With 100W step type Electronic regulator including Concealed MS fan hook box.
Call bell point with 6A Bell push with Buzzer
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed heavy FRLS PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Wiring for circuit / submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class FRLS PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Light/Fan Fixtures
Supply, Installation, Testing & Commissioning of the following Light Fixture with lamp, Control Gear & All necessary accessories. Luminaries with all electrical accessories & it should be energy efficient, etc are prewired up to the terminal block & mounted on a removable control gear module for ease of maintenance. All electrical connections of the control gear module with the rest of the luminaries should be click fix & require use of no tools. Mounting options should be for both lateral as well as pole top mounting with Lamp Control Gear & Fixing Accessories. All fixtures shall be white colour & supplied with white lamps. All the light fixtures will be finally approved by Architect / Consultant/ Department. Architect / Consultant / Department reserves the right to reject the fittings suggested by the contractor.
18W (4Feet) LED Light Fixture- MAKE-PHILLIPS CAT NO. BN021C LED20S PSU CDL GR or equivalent.
15W LED surface mounted fixture MAKE-PHILLIPS CAT NO. SM251C LED20S SLEEK SURFACE or equivalent.
15W LED recess mounted fixture MAKE-PHILLIPS CAT NO. : DN153 GREENLED SMART 15W or equivalent.
36W LED recess mounted fixture MAKE-PHILLIPS CAT NO. RC380B LED30S-6500 L60W60 PSD OD S1 or equivalent.
36W LED surface mounted fixture MAKE-PHILLIPS CAT NO. SM365C LED32-6500 PSU-OD WH or equivalent.
8W MIRROR LIGHT Surface Mounted MAKE-PHILLIPS CAT NO. BN021C LED22S PSU CW GR or equivalent.
Ceiling Fans
Supply and fixing of Ceiling fan of following sweep (white colour), suitable for operation on 230 / 240V, 50 Hz, single phase, A.C, supply complete with double ball bearing motor, required down rod, capacitor, three MS blades etc complete.
1200mm Sweep 5 Star rated Ceiling fans
1400mm Sweep rated Ceiling fans
Exhaust Fans
Supply, Installation & Testing of following 900 RPM heavy duty exhaust fan suitable for single phase, 240V, AC supply complete with motor, MS louvers, mounting brackets all accessories etc complete.
300mm Sweep
Supply Installation Testing and commissioning of TPN MCB Double door Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB /ELCB as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in concealed in wall after necessary chase cutting with finishing / surface in wall including all fixing materials required. MCBs shall conform to IS : 8828 and ELCB shall conform to IS :12640. All MCBs shall be 'C' Curve. DBs shall be provided along with required wire adopter boxes around the DB as required and dummys for spare ways in the DB (No claim shall be allowed for the same).
6Way TPNMCBDB with 63A, 100mA 4Pole RCBO as incomer and 15nos 6-25A SPMCBs and 3nos 8KA SP SPDs as outgoings.
SUBHEAD X : AIR CONDITIONING VARIABLE REFRIGERANT FLOW ( VRF)
OUT DOOR UNITS ( CONDENSING UNIT)
Supply, Installation, Testing and commissioning of VRF system with DC inverter compressor technology. The system shall be complete with indoor unit, condensing unit, Controls, Micro-processor controls, individual temp control of each indoor unit, control panel, wiring, refrigerant piping, insulated Drain pan low noise condenser fan coupled with variable speed motor, auto check-function for connection error, auto addressing Including required no. of multi connection piping kit . and all accessories required for smooth operation of the system. The Refrigerant gas should be R410A and capable of cooling as well as Heating ( Heat pump ) The system shall be complete with inrconnected refrigerant piping , full charge of R-410 refrigerant gas & oil, control cabling, M S framework for mounting the condensing unit, on terrace Fabricated out of steel channels of adequate st rength. The unit shall be mounted on framework by means of 8mm thick neoprene type vibration isolators.etc.
Supply, Installation, Testing and Com missioning of condensing units with air cooled condenser with scroll compressor, Inverter Control with stepless modulation for precise capicity control of frequency differential of 1 hz, system should have oil seperation and return mechanism to ensure complete oil recovery & outdoor units should have minium 20-27 steps / VFD in ODU fan motor for the stability of suction and discharge pressure and quick response to IDU temperature control, scope includes inrconnected condenser refrigerant piping, control panel cabling etc. The prices should include lifting, shifting and positioning of outdoor units. The unit shall be factory charged & any top-up gas/ oil required for first charge should be included in the individual price quoted below.
34 HP Out Door Unit
36 HP Out Door Unit
INDOOR UNITS ( EVAPORATIVE UNIT)
Supply, Installation, Testing and Commissioning of indoor units complete with blower, cooling coil, insulated drain pan, air filter of efficiency 80% down to 20 microns. Scope includes supporting framework for mounting of indoor unit fabricated out of steel channels of adequate strength complete as required. The entire framework shall be duly primer coated and painted black. The Min Capacity of IDUs shall be as specified under. (Min Capacity)
4-Way Cassette Unit complete with drain pump.
Treated Fresh Air Unit complete with drain pump.
Supply, Installation, Testing and Commissioning of Ceiling hung ductable indoor unit with evaporator coil, fan section with low noise fan, multispeed motor, outer cabinet, drain pump, drain pan, spring isolators for hanging arrangement, corded remote controller mounted inside powder coated MS box, pre-filter, silicon coated flexible duct connection, etc. complete as required. The minimum fan external static should be 200Pa. Each IDU shall have mixing box for connecting fresh air to unit complete with provision to clean filters. (Remote to be quoted separately)
Supply, Installation, Testing and Commissioning of Y-joints and T joints of required sizes for SUB & connections of refrigerant pipes to units.
Controller
Supply, Installation, Testing and Commissioning of A.C. corded remote controller
Supply, Installation, Testing and Commissioning of A.C. cordless remote controller
Supply, Installation, Testing and Commissioning of 4 star Inverter Hiwall split unit complete with ODU & IDU. The condensing unit shall be with air cooled condenser with scroll compressor, with Hi wall indoor unit consisting blower, cooling coil, air filter of efficiency 80% down to 20 microns & insulated drain pan. Indoor units should have wireless / corded Remote Cont roller as a standard accessory. (Min Capacity)The prices should include lifting, shifting and positioning of outdoor units. The unit shall be factory charged & any top-up gas/ oil required for first charge should be included in the individual price quoted below.
Refrigerant Piping
Supply, Laying, testing and commissioning of copper refrigerant piping inside the building (including circuit of liquid & suction-0.8 mm thickness for soft pipe up to 19.1 mm dia and 1.0 mm for hard pipe above 19.1 mm dia) duly insulated with 19 mm / 13mm thick pre-formed moulded sections of closed cell XLPE insulation of class 'O' fire rating having uniform density not less than 25 kg/cum, with necessary support & accessories complete in all respects for following sizes.
31.8 mm dia / 19 mm thick insulation
28.6 mm dia / 19 mm thick insulation
25.4 mm dia / 19 mm thick insulation
22.2 mm dia / 19 mm thick insulation
19.1 mm dia / 13 mm thick insulation
15.9 mm dia / 13 mm thick insulation
12.7 mm dia / 13 mm thick insulation
9.5 mm dia / 13 mm thick insulation
6.4 mm dia / 13 mm thick insulation
Drain piping
Supply, Installation, Testing and Commissioning of Hard PVC Drain piping with drain t rap & insulated with 6mm thick make Nitrile Rubber Sleeve insulation with necessary tees, elbows and fit t ings. All drain piping shall be firmly supported by M S painted angles from ceiling.
25mm Dia
32mm Dia
AIR DISTRIBUTION :-
Supply, Fabrication, installation, testing, balancing and commissioning of GSS sheet metal ducting complete with TDF flangs,elbows, splitters, vanes, hangers, supports and rubber gasket sealing as per approved drawings. GSS ducting :- as per IS- 655/ 1963 revised till date required for dehumidified air distribution.
Supply, installation, testing & commissioning of extruded aluminium constructed continuous linear Grill.
Supply, installation & balancing of Volume control device at supply / return air grill complete with nuts bolts, screws, linkage, flanges etc.
Supply, installation & balancing of duct mounted Volume control dampers at supply / return air duct complete with nuts bolts, screws, linkage, flanges etc.
Providing & fixing fire proof double layered canvass cloth connection for Ductable split indoor unit outlet complete with flanges made out of 22G G.S.S sheet complete with nuts, bolts etc.
Supply, installation, testing & commissioning of Fresh air intake louvers duly powder coated (of approved colour) made of extruded aluminium profiles construction, complete with Box type volume control damper in aluminium construction with 3-5% leakage at 50mm pressure differential, multi-layer wire mesh filter
INSULATION :-
Supply and application of Thermal insulation of supply air ducting with factory faced Al. foil Nitryl rubber insulation material 13 mm thick of min 35Kg/cum density.
Supply and application of Acoustic lining of supply air ducting complete with G.I frame, t issue paper, 28G perforated al. Sheet , 25mm thick 32kg/ cu.m fibreglass insulation of thickness
ELECTRICAL
Supply, installation, testing and commissioning of following MCBs including outdoor box & electrical connections etc complete.
100 Amp 25 KA TPN MCB for 34 HP & 36 HP ODUs
Supply , laying , Testing and Commissioning of 2C x 1.5sqmm copper multistrand wire in & including 25 mm dia FRLS PVC conduit as per manufacturers specifications.
Supply, laying , Testing and Commissioning of following PVC insulated Copper conductor armoured cables 1100 volts complete in cable tray, clamps, saddles, cable glands, thimble etc. including effecting proper connection to the equipment as required.
4c x 25 Sq.m m for 24 HP ODUs
Supply and installation of following sizes 2 mm thick GI perforated cable tray with GI cover along with required angle supports, with coupler plates, Anchor bolts and nuts etc complete and the tray should be fitted on the wall/ceiling etc. complete.
300 x 50 mm 2 mm thick
ELECTRICAL Panel
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted outdoor panel MV panel made out of 2mm thick CRCA sheet for main frame and 1.6mm thick for partitions after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit with standing capacity of minimum 25KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only.
ODU panel. ( on terrace )
Incomer - 250A 4P MCCB (25 KA) with Microprocessor based release unit with Protection:-1 set
0-500 Volts, digital Voltmeter and shall be protected by 2Amps MCBs. -1 set
0-250 Amps digital Ammeter -1 set
Phase indicating lamps and shall be protected by 2Amps MCBs.
Each incomer / outgoing multifunction meter with RS485 connectivity.
Bus Bar:
250 Amps TPN Aluminium busbars, colour coded with heat shrinkable insulation sleeves - 1 set
Outgoing:
All Outgoing Shall have 16 KA rating .
5 nos 63Amp TPN MCB for ODUs
SUBHEAD-XI POWER WIRING
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed heavy class FRLS PVC conduit as required
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supply Installation Testing and commissioning of TPN MCB Double door Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB /ELCB as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in concealed in wall after necessary chase cutting with finishing / surface in wall including all fixing materials required. MCBs shall conform to IS : 8828 and ELCB shall conform to IS :12640. All MCBs shall be 'C' Curve. DBs shall be provided along with required wire adopter boxes around the DB as required and dummies for spare ways in the DB (No claim shall be allowed for the same).
6Way TPNMCBDB with 63A, 100mA 4Pole RCBO as incomer and 21nos 6-25A SPMCBs and 3nos 8KA SP SPDs as outgoings.
Supply and laying of 80mm dia Class 'B' GI pipes laid 750mm below ground level including excavation, back filling etc., complete.
Supply and fixing of following HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461, Steel wire mesh cable trays with internal dimensions & load bearing capacities as given below, including couplers, mounting accessories with including all fixing accessories and including 2runs of 25x5mm GI strip along with cable tray etc., complete as required.
150mm x 54mm, The Load bearing capacity of the Cable Trays should be minimum of 29.51KG/meter at the span of 1.5Meter.
300mm x 54mm, The Load bearing capacity of the Cable Trays should be minimum of 57.66KG/meter at the span of 1.5Meter
SUBHEAD XII : UPS WIRING
Wiring for light point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy class FRLS PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc as required.
Group-C
Supply, Installation, Testing & Commissioning of the following Light Fixture with lamp, Control Gear & All necessary accessories. Luminaries with all electrical accessories & it should be energy efficient, etc are prewired up to the terminal block & mounted on a removable control gear module for ease of maintenance. All electrical connections of the control gear module with the rest of the luminaries should be click fix & require use of no tools. Mounting options should be for both lateral as well as pole top mounting with Lamp Control Gear & Fixing Accessories. All fixtures shall be white colour & supplied with white lamps. All the light fixtures will be finally approved by Architect / Consultant/ Department. Architect / Consultant / Department reserves the right to reject the fittings suggested by the contractor.
18W (4Feet) LED Light Fixture MAKE-PHILLIPS CAT NO. BN021C LED20S PSU CDL GR or equivalent
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 3 nos. 5 pin 5/6 A modular socket outlet and 1 nos. 15/16 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supply and fixing of modular type single phase 1no 16A, 6 pin shuttered type Socket with 1nos 16A switch with front plate and anodised GI box including all fixing accessories.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed heavy class FRLS conduit as required
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supply Installation Testing and commissioning of TPN MCB Double door Distribution boards dust, water proof and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB / RCBO as per specifications and required capacity Neutral bar and Earth terminal complete as required and installed in flush with wall including all fixing materials required. MCBs shall conform to IS : 8828 and ELCB /RCBO shall conform to IS : 12640. All MCBs shall be D Curve.
6Way TPNMCBDB with 63A 4Pole MCB & 4P 32KA SPDs as incomer and 18nos 6-25A SPMCBs as outgoings.
Earthing
Providing maintenance free Earth station with consisting of 65mm dia pipe standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, seald at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5mtrs. Earth enhancement compound upto a depth of 2.0meters arround the electrode capsule. Brick chamber & CI Cover complete.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
25 X 5mm Copper strip
SUBHEAD XIII: SHOP ELECTRICALS
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply installation testing and commissioning of Vertical type MCB Double door Distribution boards dust and vermin protected and AC supply operation including incoming MCCB/ MCB/ ELCB / RCBO as per specifications and required capacity Neutral bar and Earth Terminal complete as required and installed in concealed in wall after necessary chase cutting with finishing / surface on wall including all fixing materials required. All MCBs shall be "C" Curve
8Way VTPN MCBDB with 160A, 25kA 4 Pole MCCB as incomer and 6 Nos 63A 3P MCBs, 2 Nos 40A 3P MCBs, as outgoing.
Earthing
Providing,fixing testing & commisioning of maintenance free Earth station with consisting of 40mm dia pipe standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, seald at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5mtrs. Earth enhancement compound upto a depth of 2.0meters arround the electrode capsule. Brick chamber & CI Cover complete.
Providing,fixing testing & commisioning of GI Electrode Earthing with 40 mm dia and 3 meter length, The electrode should be hot-dip galvanized with upto 120 micron. The GI Strip In Pipe Electrode shall be pre-filled with Crystalline Conductive Material (CCM) . The GI electrode shall be surrounded with 50 kg JAM Fill compound to provide maximum contact between the electrode and the soil. Backfill compound should be eco-friendly and having RoHs certification. GI Electrode Earthing should be maintenance free and dose not required regular manual addition of water. GI Electrode Shall be tested from CPRI. The earthing pit should be cover with FRP pit cover of 300x300mm bottom and 200x200m with 150mm height in green colour. as per JAM 193.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required.
SUBSTATION ACCESSORIES
Supply & Laying of non skid Electro mat 1 mtr wide and 3.0 mm thick 11KV grade conforming to IS 15652 as required including cutting to required length complete as per requirement of local electricity authorities.
Supply & Laying of non skid Electro mat 1mtr wide and 2.0 mm thick 1.1KV grade IS 15652 as required including cutting to required length complete as per requirement of local electricity authorities.
Supply and erecting 4.5KG Carbon Dioxide (CO2) Fire Extiguisher with necessary clamps made from 50 x 6mm M.S. Flat with Nut & Bolts growted in wall complete.
Providing printed instruction chart both in English, Hindi and local launguage and duly framed with front glasses, for treatment of person suffering from Electric shock.
Supply of Rubber hand gloves 11KV grade, as per IS 4770-1968.
Supply and laying of following dia. NP2 grade RCC hume pipes with collars for road crossings, laid 750mm below ground level including excavation, back filling etc., complete.
100mm dia.
300mm dia.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
80 mm dia
100 mm dia.
Supply and fixing of outdoor type 4nos 9Ltrs Fire buckets round bottom type enamelpainted, white inside & Red out side with FIRE mark, filled with dry sand and Supply and erecting floor mounting stand for keeping four nos. of FIRE buckets comprising 1500mm in length, 900mm height frame made out of 30mm x 30mmx 4mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of approved enamelled silver paint.
Supply and fixing in position the best quality "Danger Boards" of approved shape and size as specified by Local Electricity Authorities written in English and Local languages.
11000V (250mm X 200mm)
440V (150mm X 100mm)
SUBHEAD XIV : TELEPHONE CONDUITING
Supply and laying of 25mm dia, heavy duty FRLS PVC conduit concealed in wall / ceiling / floor including all accessories such as Junction boxes, conduit bends, etc. completed as required.
Supply and laying of 32mm dia, heavy duty FRLS PVC conduit concealed in wall / ceiling / floor including all accessories such as Junction boxes, conduit bends, etc. completed as required.
Supply and fixing of Telephone outlet (RJ11) with anodised GI box with front plate etc. complete as required.
Supply and laying of following pair 0.5mm dia PVC insulated unarmoured copper conductor Telephone wire in existing conduit conforming to DOT Specifications.
Supply and installation of following size Krone connectors in MS box complete as required.
10 Pair Tag Block
50 Pair Tag Block
Supply and laying of following pair 0.5mm dia Jelly filled armoured copper conductor Telephone cable in shaft existing cable tray with all fixing accessories. The cable shall be as per the DOT specifications.
Supply and fixing of Data outlet (RJ45) with anodised GI box with front plate etc. complete as required
Supply and laying of UTP 4 Pair CAT 6 LAN Cable in existing conduit complete as required.
RACEWAY
Supply, installation, testing and commissioning of following sizes PVC raceway with cover - above and below floor/ceiling / wall as per direction of engineer in charge with necessary supporting to distribute Power, Data and Telecom cables including junction box, riser, coupler etc including all accessories.
100 x 38mm two compartment
150 x 38mm three compartment
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
200 mm X 150 mm X 60 mm deep
SUBHEAD XV : SPECIAL EARTHING
Providing maintenance free Earth station with consisting of - 65mm dia, standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, seald at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5mtrs.
Earth enhancement compound upto a depth of 2.0meters arround the electrode capsule.
Brick chamber & CI Cover complete.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing GI Electrode Earthing with 40 mm dia and 3 meter length, The electrode should be hot-dip galvanized with upto 120 micron. The GI Strip In Pipe Electrode shall be pre-filled with Crystalline Conductive Material (CCM) . The GI electrode shall be surrounded with 50 kg JAM Fill compound to provide maximum contact between the electrode and the soil. Backfill compound should be eco-friendly and having RoHs certification. GI Electrode Earthing should be maintenance free and dose not required regular manual addition of water. GI Electrode Shall be tested from CPRI. The earthing pit should be cover with FRP pit cover of 300x300mm bottom and 200x200m with 150mm height in green colour. as per JAM 193.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supplying and laying of bare GI tape of the following earthing clamped to wall with suitable clamps saddles and fixing bolts/soldering /riveting in ground including the cost of digging and back filling as required and complete as required to comply with IS 3043:1987. All joints shall be tined.
50 x 5 mm GI strip
Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required.
SUBHEAD XVI : LIGHTING PROTECTION SYSTEM
Supply and installation of vertical air termination with 40mm dia copper hollow sphere with spikes, fixed on 1000mm length 25mm dia Copper rod including PCC block and all fixing accessories.
Supply GI Electrode Earthing with 40 mm dia and 3 meter length, The electrode should be hot-dip galvanized with upto 120 micron. The GI Strip In Pipe Electrode shall be pre-filled with Crystalline Conductive Material (CCM) . The GI electrode shall be surrounded with 50 kg JAM Fill compound to provide maximum contact between the electrode and the soil. Backfill compound should be eco-friendly and having RoHs certification. GI Electrode Earthing should be maintenance free and dose not required regular manual addition of water. GI Electrode Shall be tested from CPRI. The earthing pit should be cover with FRP pit cover of 300x300mm bottom and 200x200m with 150mm height in green colour. as per JAM 193.
Supply and laying of following size earth strips the same shall be laid at a depth of 750mm below ground level including excavation and refilling of earth necessary interconnections with earth station and equipments.
50 x 6 mm GI strip laid in Ground
Supply and laying of following size earth strips with all fixing accessories when laid on the parapet & terrace with necessary interconnections with earth station and equipments.
25X5mm Aluminium strip conductor with DMC Insulated Supports
SUBHEAD XVII : FIRE ALARM SYSTEM
Supply and fixing of Double Loop addressable control panel with Loop Driver card, complete with Batteries for 30 mins backup in normal condition + 10 mins backup with 25% Loop under fire condition. Complete as required
Supply and laying of twisted pair 1.5sq.mm shielded FRLS insulated copper conductor flexible wire through existing MS Conduit.
Supply and fixing of 25mm dia 16SWG MS conduit concealed/ Surface in wall/ Ceiling/ above false ceiling including painting with 2 coats of Red colour paint for exposed part and all fixing accessories/ materials
Supply and fixing of Multi-sensor combined optical smoke sensor and thermal sensor in a single housing with base .
Supply and fixing of Remote response indicator having twin LED flush mounted on false ceiling/wall of same make as detectors and panel.
Supply and fixing of Intelligent Addressable Double Action (One Stage) Fire Alarm Station MCP (manual call point).
Supply and fixing of Addressable horn-strobe, hi/lo db with base .
Supply and fixing of Intelligent Addressable Output control module for fire integration with Access control, PAC, Gas suppression etc. and third party fire alarm panel integration.
SUBHEAD XVIII : WATER COOLER
Supplying, installation, testing and commissioning of water cooler Electric driven (single phase), Having storage Capacity of 80 litres and nominal cooling capacity of 60 Litres per hour. Make: Bluestar/ Usha /Voltas and RO Water Purifier of 25 litres /hr capacity RO+UV+UF with TDS Controller .Make- kent/Urekafobes or eqvl.
SUB HEAD-XIX- ROADS , PAVEMENTS AND DRAINS
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).
Supplying and stacking at site.
Good earth
Moorum
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler,cleaning and preparing the existing road surface as per specifications :
On W.B.M. @ 0.75 Kg / sqm
Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge.
40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete.
New work (Two or more coats)
Providing and fixing cement concrete designer tiles similar to Eurecon tiles of approved make, specification, colour and size laid in cement mortar 1:3 on existing bed and pointed with white cement mortar 1:4 mixed with colour pigment to match the colour of tiles finishing nicely all as per directions of Engineer-in-Charge with necessary cleaning and wash etc., compleate for flooring. The tiles are to be laid in the pattern given in the approved drawings and approved by Engineer-in-Charge including all lead lift, cutting charges etc., complete. Tile thickness 20mm thick.
For flooring at all levels.
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction and of approved size and design/ shape laid in required colour and pattern over and including 50mm thick compacted bed of course sand, filling the joints with Coarse Sand (M-Sand) etc. all complete as per the direction of Engineer-in-charge .
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing Rain water harvesting pit of size 2m dia and 2.5m depth. The pit shall have 750mm of 40mm stone agreegate at the bottom over which there shall be 750mm of 40mm of stone aggregate and 1000mm of coarse sand filling respectively. Brick work allround the periphery of the pit 300mm below ground and 150mm of above.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand (Manufactured)) including testing of joints etc. complete :
150 mm dia. R.C.C. Pipe
300 mm dia. R.C.C. Pipe
450 mm dia. R.C.C. pipe
SUB HEAD-XX- EXTERNAL WATER SUPPLY
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling with two coats of anti-corrosive bitumastic paint of approved quality etc.
External work
50 mm dia nominal bore
65 mm dia nominal bore
Making connection of G.I. distribution branch with existing G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
50 to 80 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
50 mm nominal bore
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve,with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand (Manufactured) : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand (Manufactured) : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3coarse sand (Manufactured)) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Supply and fixing water supply route marker with route indication on 150 mm. dia. Cast iron disk bolted in 40x40x3mm. angle iron grouted in 1:3:6 concrete block 150x150x300mm. deep including two coarse of aluminum paint on metal work.
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 :with two coats of anti-corrosive bitumastic paint of approved quality and filling sand of grading zone V or coarser grade, allround the pipes, trenching, refilling & testing of joints complete as per relevant IS code & direction of Engineer in charge.
150 mm dia Ductile Iron Double Flanged
SUBHEAD XXI : EXTERNAL ELECTRICAL POWER SUPPLY
11 KV MAIN OUTDOOR TYPE HT PANEL BOARD -
11 KV MAIN OUTDOOR TYPE HT PANEL BOARD ( One incomer and two out goings) Design, manufacture , supply, installation, testing and commissioning of 11KV, VCB out door type panel board fabricated out of 2mm sheet steel, dust tight, vermin proof, totally enclosed and fully interlocked, IP 5X protection, cubicle type, floor mounting, extensible on both sides, suitable for outdoor operation at 11 KV, 3 phase, 50 Hz, AC supply complete with rack in - rack out mechanisms, switches, plugs &sockets and all required accessories, cable termation box at back with bottom cable entry for cable size upto 3 core 240 sqmm. armoured cable for each section, internal copper wiring, earth terminals, painting etc. as required , as per specifications enclosed with the following equipped switch gears and accessories.
1 NO. Each feeder shall consist of : i) 630 Amps., 11KV horizontal draw out type VCB with motorized spring charge mechanism and required safety switchgears complete. ii) 11 KV / 110 volt PT of class 0.5 accurancy & 100 VA burden. iii) Set of dual core dual ratio CTs of 50 / 1 / 1 Amps. of 15 VA burden & accurancy class 0.5 for metering and class 5 P 10 for protection. iv) 144mm x 144mm square type dual scale 0-60A ammeter with ASS v) 144mm x 144mm square type 0-15kv Voltmeter protected by HRC fuses / MCBs with VSS vi) 144mm x 144mm square Digital tri-vector Meter (Smart Controller) having 30 days memory equivalent to Schneider (Conzerv) Cat. No. EM6400 series, Cl -0.5 with MDI & RS 485 port. vii) 144mm x 144mm square frequency meter viii) Micro processor based feeder protection numerical relay with adjustable O/L, E/F and short circuit protection with communication port. (O/L Setting 50-200% and E/F setting 20-80%) ix) Set of LED indication lamp protected by MCB for RYB Phases, trip, ON & OFF, spring charge, auto trip / trip healthy of breaker complete.
x) Annunciator window (with minimum. 4 window) for feeder alarm / tripping annunciations with electronic hooter. xi) Master trip & trip circuit supervision relay, Antipumping Relay, complete. xii) Limit switches for tests & service position, circuit breaker control switch (T/N/C)xiii) Trip coil operation at 24 Volts DC through power pack B) BUSBARS i) 630 A TP Copper bus bar
OUTGOING - 02NOS. Out going - 1x630 Amp as incomer for 1x315 kva transformers at one existing sub station & 1x630 Amp as incomer for 1x250 kva transformers at proposed sub station .Each feeder shall consist of : i) Set of dual core CTs of 20/5/5 A of 15 VA burden and accuracy class 1.0 for metering and class 5 P 10 for protection as required. ii) 96mm x 96mm square Digital Ammeter with inbuilt ASS iii) Micro processor based feeder protection numerical relay with adjustable O/L, E/F and short circuit protection with communication port. (O/L Setting 50-200% and E/F setting 20-80%) iv) Set of LED indication lamp protected by MCB for trip, ON & OFF, spring charge, auto trip / trip healthy of breaker complete. v Annunciator window (with minimum 4 window) for feeder alarm / tripping annunciations with electronic hooter. vi) Master trip & trip circuit supervision relay, Antipumping Relay, Auxiliary Relay complete. vii) Limit switches for tests & service position, circuit breaker control switch (T/N/C) viii) Trip coil operation at 24 Volts DC through POWER PACK
COMPACT SUBSTATION:-
Supply, Installation, Testing & Commissioning of Outdoor type 11KV, 250 kVA Package sub-station (PSS) suitable for 11kV, 50Hz, complete with 2 way RMU with VCB and LT panel. Degree of protection IP54 for LT & HT compartments and IP23D for Transformer compartment, Cable termination facility, internal illumination, earthing, interconnection of Transformer with HT & LT equipments.
HT Cables
Supply, testing and commissioning of following size 11/6.6 KV XLPE insulated armoured aluminium conductor under ground cable.The cable shall conform to IS 7098/ Part II.
3C X 95 sq.mm
Laying of one number PVC insulated and PVC sheathed XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning,protective covering and refilling the trench etc. as required.
Upto 120 sq. mm
Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 11 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 120 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in the existing masonry open duct as required.
Upto 120 sq. mm
Providing Indoor Heat shrinkable end terminations for the cable specified above with all materials, lugs using crimping tool, 11KV Insulation tape, Identification tags etc., including end termination and Earthing of Gland.
3C X 95 5sq.mm Indoor type
Providing outdoor Heat shrinkable end terminations for the cable specified above with all materials, lugs using crimping tool, 11KV Insulation tape, Identification tags etc., including end termination and Earthing of Gland.
3C X 185sq.mm outdoor type
Rerouting & dismantling of 11 kv following size 11KV XLPE insulated armoured aluminium conductor under ground cable complete as required.
3C X 240 sq.mm
LT Panels
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted LT panel made out of 2mm thick CRCA/ Galvanised steel enclosure for main frame and 1.6mm thick partitions and the panel shall be got fabricated from manufacturers with CPRI Test certificate only, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. Indoor panels shall have IP-4X degree of protection and outdoor panels shall have IP-55 degree of protection wiith external door. Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/ Hylam/ Bakellite sheet inside the panel for partitions or any other purpose.
Sub station
Incoming :
630A, 50KA 4pole MCCB with O/C, S/C & ELR with CBCT & 630A FP Power contactor - 1sets
Busbars :630A TPN Aluminium busbars - 1 set
(Neutral shall be 100% Phase busbar)
Outgoings :
250A 25KA TP+NL MCCBs –2no for AC System. (1 Spare)
150A 25KA TP+NL MCCBs – 03no(02 Nos V. DB +1 Spare)
100A 16KA TP+NL MCCBs – 1nos (UPS Panal Future Provision)
40/63A 10KA TP+NL MCCBs – 2nos ( For Area Lighting+ Spare)
65A AC1 Contactor with 230V Coil and a Time
Switch similar to L&T TSQ 100 -1set
40A 10KA DP MCBs - 1nos (Spare)
Metering :
LED Phase indication lamps with individuals Fuses and control with toggle switches-2sets
CT Operated Load manager with RS485 port (Similar to EM-6400) – 7sets
Resin cast CTs of ratio 630-100/5A, Class 1 Accuracy and 15VA burden on R phase for APFCR -1no
APFC PANAL
Supply and installation testing & commissioning of Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity85(25+25+15+10+5+5) KVAR in six steps with 4 pole 250 Amps MCCB alogwith suitable contactor & relays.
INCOMER:
1 No. 250 Amp,35 KA,TP with neutral link MCCB complete with thermal magnetic release having over current, short circuit, protection.
3 Nos. Cast resin 250/5 Amp class 1.0,15 VA Burden C.T's for metering.
Three phase indicating lamps.
BUSBAR:
Electrolytic high conductivity aluminium three phase busbars rated at 300 Amp having a maximum current density of 0.8 amp per sq mm suitable to with stand symmetrical fault level of 50 KA at 415 volts.
OUTGOING:
6sets of 100/63/32A TP MCCB with DOM 25 KA.
TP Capacitor duty contactor as suitable for capacitor with 230 V A.C supply
1 No 8 step APFCR intelligent Digital Relay with binary operation without time delay.
7sets of self illuminated Red-green push buttons.
7 Nos. of TP shunt capacitor with D-tunned reactor as describe rating as above.
On/off Indicating light
Timer -1 No.
Auxilliary Contactor-1 No.
MV Cables
Supply, testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable.The cable shall conform to IS 7098/ Part I.
3.5C X 240 Sq.mm
3.5C X 150 Sq.mm
3.5C X 120 Sq.mm
4C X 16 Sq.mm
4C X 10 Sq.mm
Rerouting & dismantling of 1.1 kv following size XLPE insulated armoured aluminium conductor under ground cable.
3.5C X 150 Sq.mm
Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Upto 35 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number additional PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Upto 35 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUMEI METAL pipe as required.
Upto 35 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and fixing cable route marker with route indication on 150 mm dia cast iron disk bolted to 40x40x3mm angle iron grouted in 1:3:6 concrete block 150x150x300 mm deep including two coats of aluminium paint on metal work.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 240 sq. mm (62mm)
3½C X 120 Sq.mm (45mm)
3½ X 150 sq. mm (50mm)
4C X 10 Sq.mm (25mm)
4C X 16 Sq.mm (28mm)
Providing Chain Link fencing around TPMO and CSS yard upto 2.4m height with a continuous brick masonry kerb wall of 600mm above ground with suiatble foundation and palstering of the same as per standard practice.
Supply and fixing of 1.5X2.4m MS weld mesh gates for Transformer yard as per standard design and with earth connection from fence
Spreading of two layers of 40mm stone metal inside the Transformer yard
SUB HEAD-XXII - SEWAGE DISPOSAL
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement :1 fine sand (Manufactured)) including testing of joints etc. complete :
100 mm diameter
150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand (Manufactured) : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
100 mm diameter S.W. Pipe
150 mm diameter S.W. Pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
150 x 100 mm size P type
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement :4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (Manufactured) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (Manufactured) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand (Manufactured)) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand (Manufactured) : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes
Size 90x80 cm
With common burnt clay F.P.S. (non modular) bricks of cass designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand (Manufactured) : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
Circular shape 560 mm internal diameter
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.w. dran pipe 100 mm diameter, 1.8 m long complete as per standard design.
With common burnt clay F.PS. (non modular) bricks of class designation 7 .5
SUBHEAD XXIII : AREA LIGHTING
Supply and erection of steel stepped and swaged tubler poles of 9mtr. Long (410 SP25) (1.5mtr below Ground) with base plate, earthing studs,1.5Mtr out reach single arm, FRP terminal box, 2nos 50mm diaclass B GI Pipe, 1.5mtr. Long for incoming and outgoings cables, including PCC Pedestal complete with painting with black bitumin paint inside the coping for embedded portion and two coats of Zinc chromate primer and two coats of Aluminium paint externally for length above the ground. The pole shall be with Junction box consisting of MCB. The wiring from Junction box to Light fixture shall be carried out with 3core 2.5sq.mm multistrand conductor cable. The Pole shall be fixed with 72W LED Lamp with fixture including supply of Controlgear/driver and lamp (Philips : BRP410 LED CW 072 MR FG S1 PSU GR )
Supply, erection and commissioning of individual 3mtr (600mm below Ground) high 50mm dia Class B GI pole, 750mm out reach single arm complete with base plate FRP terminal box, wiring from terminal box to the fixture with 3core 2.5Sq.mm multistrand Copper conductor cable, MCB control and 2nos of 40mm dia class B GI pipe for incoming and outgoing cables as per drawings etc including PCC foundations, pedestal and Supply and installation of 36W LED Lamp Post top Lantern fixture. (Similar to Bajaj :BRIL 45W LED NW)
Providing Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments.
MV Cables
Supply, testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable.The cable shall conform to IS 7098/ Part I.
4C X 10 Sq.mm
4C X 6Sq.mm
2C X 6Sq.mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4C X 10 Sq.mm (25 mm)
4C X 6 Sq.mm (25 mm)
2C X 6Sq.mm(19 mm)
SUB HEAD-XXIV ARBORICULTURE/ LANDSCAPING
AVENUE TREES PLANTATION
Digging of pits / holes of size 1m dia and 1m deep in all kinds of soil and refilling the with the excavated earth & supplied good earth whenever required mixed with manure or sludge in the ratio of 2:1 by volume (2 part of good earth : 1 part of manure ) additives , anti-termitetreatment and manure (cost include). Flooding with water , dressing include removal of rubbish and surplus excavated earth, if any with all leads and lifts (extra gooth earth if needed to be paid for separately after the reduction by 20% )
Supply & plantation of flowering or foilage or desired ,well grown Tree of 6'-8' height sapling with disease / insect free , good foilage and stem girth. Staking theTree sapling with bamboo stakes of same height & 25mm thick, treated with anti termite solution & fixing in position, tie with stick at two suitable places. After plantation tree saplings & bamboo staking are to be maintained for 180 days as the minimum guarantee period including replacing the casualties with the same size and girth of tree sapling if any.
List of trees are as following :-
(i) Avenue Flowering Tree:- Rain Tree / Peltophorum / Cessea semia / Bottle Brush or equivalent.
(ii) Decorative Tree:- Bottle Palm / Fish tail Palm / Pougoville / Traveller Palm / Ashoka / Plumeria Alba / Ficus benjamina / F.Rejnold & equivalent.
SHRUBS PLANTATION
Preparation of beds for shrubs by excavating 60 cm deep / pits of size 60 cm dia. And 60 cm deep in any type of soil. Refilling the excavated earth after breaking clods, additives & antitermite treatement and mixing with sludge or manure in the ratio of 3:1 (Three part of good earth and one part of organic manure) cost include. Flooding the beds / pits with water so that the earth and mamure mixture settles down. Supply and plantation of approved shrub species sapling of 1.5' height, about 1-2 years old sapling with well grown, disease / insect free and with a clear minimum height of 1.5' feet after plantation. Stacking the plant is essential with bamboo stick of same height treated with anti-termite solution & fixing in position, tie with stick at suitable place. After plantation saplings are to be maintained for a period of 180 days including replacing the casualities if any.
Regular shurbs : Hamelia / Hibiscus Green / TMC Green / Ficus Panda / Callendra / Acalypha / Cassia Biflora or equivalent (approx. 1.5' - 2 ht).
LAWN DEVELOPMENT
Uprooting rank vegetation and weeds by digging the entire area in any type of soil up to a depth of 30 cms deep. Making up the digging area to proper levels by filling with earth before and after flooding area with water. Rough dressing the trenched ground including breaking clods and if additional good earth is required it will be paid separately on actual measurement basis after the reduction of 20% its volume. Spreading of sludge or manure and then mixing with good earth in the ratio of 8:1 upto depth of 30 CM. Uprooting fresh growth of weeds after 10 days and then fine dressing, levelling.
(i) In rows 5 cm apart in both direction
HEDGE PLANTATION
Preparation of beds/ trench for hedging by excavating 60 cm deep x 45 cm wide x RM in length in all type of soils. Refilling the excavated earth after breaking clods and mixing with sludge or organic manure in the ratio of 5:1 (Five part of good earth and one part of organic manure ) flooding with water, filling with earth if necessory ( good earth paid for separately on actual measurement basis after the reduction of 20% its volume). Levelling and fine dressing for planting hedge sapling .
Supply and plantation of approved hedge species like Golden duranta / Cholorodendron inermie sapling in staggard condition of 1' height after the plantation, about 1-2 years old with well grown, disease / insect free and plantation the minimum 07 number of sapling per running metre. Maintenance for a period of 180 days as the minimum guarantee period.
ORNAMENTAL PLANTS
Supply and plantation of ornamental plants including digging of pits size 60 cm dia and 60 cm deep. Mixing of organic manure in the ratio of 3:1 (three part of good earth and one part of organic manure ). Plantation of the approved varieties of Ornamental plant sapling, it should be well grown, disease / insect free. After plantation plants are to be maintained for a period of 180 days including replacing the casualties with same size & age of plant if any.
Washingtonia palm 3'-4' ht.
Ficus Black 5-6' ht, bushy & well developed
SEASONAL FLOWER BED
Preparation of bed as per the item 2 (a) shrub plantation in beds except the plantation seedlings of seasonal flowers with 10 cm to 30 cm (small to large flower sapling) apart Seasonal flower beds to be shown freshly in every flowering season.
Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment).
Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).
NOTE: 1) Certain Scheduled items like Earth Work , PCC (1:2:4, 1:4:8), RCC, Reinforcement steel, RR Masonry, pointing, etc.,,,repeated in various sub heads, Bidder is requested to quote the same rate for similar items. However , if there is any veriation in rates quoted by Bidder in similar items under different sub heads, the lowest rate shall be considered.
RKEC Projects Limited
SREE LAKSHMI CONSTRUCTIONS
Aircon Technique Pvt Ltd
Verma Brothers
ELIXIR MET FORM PRIVATE LIMITED
RMK Projects
Hi-Tech Infrastructure
NIMMA NARAYAN ENGINEERS & CONTRACTORS
SAI CONSTRUCTIONS
R Wadhumal and sons
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .