| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC VILL JAMGAHAH PO JAMGARAH LAUDOHA BURDWAN BURDWAN EASTCHM WEST BURDWAN BARDHAMAN 713363 WEST BENGAL INDIA | BURDWAN | BURDWAN BARDHAMAN | WEST BENGAL | 713363 | L1 | Accepted-AOC Quoted amount reasonable and found L1 bidder | |
| 2 | L2₹22.6 L+₹3.9 L (20.6%)Rejected-AOC | L2 | Rejected-AOC Quoted amount higher than L1 bidder | |
| 3 | Rejected-Technical E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | - | Rejected-Technical PROPER DOCUMENTS NOT UPLOADED |
Tender Value
₹21.2 L
EMD Value
₹42,320
Closing Date
10 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHAILENDRA SINGH RATHORE IDSE CE NFG
HQ CWE AF PANAGARH MILITARY ENGINEER SERVICES AIR FORCE STATION ARJAN SINGH PO BIRUDIAH DIST BURDWAN WEST BENGAL PIN 713148
COMMISSIONING OF 33 KV POWER SUPPLY AT AF STATION PANAGARH UNDER GE AF PANAGARH
2024_MES_649690_1
82421/PAN/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF PANAGARH
As per NIT
9 documents required · 9 mandatory
₹500
GE AF PANAGARH
₹42,320
26 Jun 2024
9 Apr 2024
17 May 2024
9 Apr 2024
10 May 2024
26 Apr 2024
10 Apr 2024 - 12 Apr 2024
Amount
Note : Prior to commencement of the subject works, the contractor needs to submit valid Electrical License in the name of himself/them self or Agreement with agency having valid Electrical License alongwith Agency's Electrical License to the Accepting Officer for his approval through GE. In absence of such documents, no work will be executed at site and to be treated as defaulter on the Contractor's part . In addition, Supervisor for execution of electrical works employed by the Contractor shall posses Supervisory Certificate of competency issued by concerned State Govt/Union Territory and the Worker/Tradesman for execution of Electrical Works must hold necessary permit issued by concerned State Govt/Union Territory.
Supply, Installation, testing and commissioning of RMU 4 Way HT 11KV outdoor type 21 KA for 3 sec, rated voltage-12 KV, operation voltage-11KV, rated lightning withstand voltage-95KV, rated frequency-50Hz, 630Amp Copper bus bar SF6 insulated not extensible compact switch gear consisting of one nos fixed load break switch (LBS) and three nos fixed vaccum circuit breaker (VCB) in SF-6 gas pressure designed for minimum 1.4 Bar & insulated, welded, stainless steel enclosed with minimum 2.5 mm thickness. The degree of protection for the inner enclosure is IP 67 with self powered microprocessor based complete numerical over current & earth fault relay comprising of the following specification/ equipment. VCB should be of duty cycle O-0.3 sec CO-3 Min-CO. The complete RMU enclosure is degree of protection IP 54. Note- Contractor shall supply outdoor RMU with outdoor enclosure.
Item No 2 Contd/... (a) The circuit breaker and earthing switch shall be lockable in the open or closed position by suitable number of padlocks of suitable size. (b) Inter panel barrier to prevent arc propagation from one panel/compartment to other. (c) Earthing switch rated for full making capacity with provision for safe & reliable position indicator. (d) Isolating plug (e) Vaccum circuit breaker unit insulated in SF-6 media shall comprising the following:- (i) Assembly of VCB interrupter completed with epoxy support insulator and self aligning isolating contracts with rating 11KV 630Amps, 21KA for 3 sec, 50Hz (ii) Manual charge and manual operated independent closing/ triping, trip free operating mechanism and breaker closed/open, spring charge/discharge indication. (iii) Mechanical operation counter -02 No (iv) The three Nos of continuous bus bar made up of EC grade copper of rating current 630A is provided. (v) Strip heater 230 volts AC single phase 80watt. (vi) Current transformer chamber comprising of 3 Nos single phase resin cst CT's of 100-50/1 and accuracy class 1.0 for metering and class 5 P10 for protection in all outgoing VCB feeder set of 3 (f) One no potential transformer (PT) three phase, dry type (resin cast) draw out type 11KV/110 volts, 100 VA burden, accuracy class 1.0 with HT & LT HRC fuses for primary and secondary complete as per IS3156-01 No. (h) Arc flash supervision of circuit breaker, cable and bus bar compartment. Cable entry from bottom side. (j) One set of indication lamp (LED) type for ON/OFF indication in all LBS/VCB.
Item No 2 Contd/... (k) One set of indication lamp (LED) type for spring charging and three Nos indication lamp for RYB phase indication in all LBS/VCB. (l) The rated current of isolator shall be 630A continuous at maximum ambient temperature, No De-rating shall be allowed for the isolator at an ambient Temp of 50 deg C. Training of 03 Person by OEM duly certified with description of Trg imported. Note:- All foundation works for RMU as per manufacturer recommendation for the installation shall be deemed to be included in the quoted rates (ii) Contractor shall submit detailed drawings with technical specification for approval of GE before procurement.
Supply, laying, jointing & testing in trenches or passing through pipe, cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, Ht electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm with including a fixing and connected accessories such as aluminium cable lugs, cable gland, nut bolts washer etc complete all as specified and as directed.
Material and labour for excavating in trenches not exc 1.50 m wide but exc 1.50 m depth for taking out/laying of underground cable, pole or stay and getting out n soft/loose soil, complete all as specified and as directed.
Returning filling in soft/loose soil, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated materials (soils) not exc 50 m and depositing where directed at a level not exc 1.50 mtr above the starting point, complete all as specified and as directed.
Supply and spreading dry sand of approved quality for cushioning of UG cable laid in trenches all as specified and directed by the Engr-in-Charge.
Supply and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed.
M&L for horizontal boring across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. Note:- (i) Making good the disturbes surface & removal of surplus soil shall be deemed to be included in the unit rate. (ii) GI pipe will be measured and paid separately under relevant item of Schedule ‘A’.
M&L for 80mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed.
Supply, fixing, jointing and testing cable end joint kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core 95 Sqmm XLPE armoured aluminium conductor cable complete all as specified and as directed.
Supply and fixing in repairs for 32x6 mm galvanized iron strip, earth continuity conductor or main earthing leading fixed to wall on batten or recess or chases or buried in ground or fixed to pole or roof with saddle and screw complete all as specified and as directed.
M&L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, Connected to galvanized earth strip 32x6 mm by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI watering pipe medium grade 20mm bore, funnel alternate layer of charcoal dust and salt, PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate cover reinforced with 8mm dia TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No 3 SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified and directed by Engr-in-Charge.
Supply, installing, testing and commissioning automatic float cum boost battery charging equipments with integrated DC feeders and 30 Volts Plate battery constant current, constant voltage (CCCV) DC battery bank including supplying suitable Nos of 2 volts 100 AH dry type batteries Qty - 15 with connecting lead, SCR controlled housed in a power coated sheathed steel cabinet not less than 2.0mm thick MS sheet suitable for 50x50x5mm thick angle iron frame and 45 cm height standing legs for fixing and fitted with a digital voltmeter & ammeter. The charger should have indications for mains supply, mode of charging (float or boost), polarity batter reverse & over load conditions. It shall have protection for over load, short circuit, reverse polarity & surge/transient. The charger have to alarm on fuse blowing & short circuit. All protections to charger & its meters shall be provided with suitable rating MCB only (incoming - 01 & outgoing - 03). The output voltage and load regulation better than 2%. The other technical specifications shall be as under :- (a) Input working voltage - 240 Volts +20%, -25%, 1-Phase, 2 Wires, 50Hz ±5%. (b) Output Voltage - 33.75 Volts (2.25 v/cell) (c) Load Terminal Voltage - 30 ± 2V (d) Integrated DC Feeders - Outgoing Feeders 6 A, 2 Pole MCB - 1 No & 32 A, 2 Pole MCB - 3 Nos (e) No load losses of complete charger - <10% (f) Ripple contents on load (rms) - within 2%
Item No 16 Contd/... (g) Over load - 110% for 30 minutes and should give visual indication for over load condition. (h) Boost charging - 2.75 volts/cell (j) Float charging - 2.25 volts/cell (k) Float cum boost charging - Automatically changes from one state to another state as per battery condition and should give visual indication for either float or boost based on charging mode. (l) Reverse polarity - No damage should be caused. A visual indication should appear with an audio alarm. Note for item No 16 - The contractor has to visit the site to check the existing system of 33/11 KV VCB for installation of battery charger, PCB circuit. Contractor has to get prior approval from GE before installation.
M/S SAIMON ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .