Loading…
Loading…
Tender Value
₹7.7 Cr
EMD Value
₹15.5 L
Closing Date
24 Sept 2026, 12:00 pmDue tomorrow
VIJAY KUMAR BHAGOTIA
W.S. Divn. No. II Rewari
Estimate of Construction of Pump Houses at Escape Channel including Civil, Mechanical and Electrical Works.
2026_HRY_546426_1
20264F2640FA BA49 4A54 A8D5 A19057DB20AD137IRR
Open Tender
Civil Works
Works
210 days
JANT SAIRWAS
3 documents required · 3 mandatory
₹20,000
₹15.5 L
Yes
office of Executive Engineer, W/S Division No. 2
11 Sept 2026
11 Sept 2026
24 Sept 2026
11 Sept 2026
24 Sept 2026
11 Sept 2026
11 Sept 2026 - 13 Sept 2026
14 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | -Credit of bricks available from dismantling of structure | 199.28 | cum | 880 | ₹1,75,366.4 |
| 1.02 | Supply, installing, testing and commissioning of 400 mm i/d DI DF Metal Seated Non Rising Spindle Sluice Valve of pressure grade PN1.6 as per IS: 14846: Body Dome: DI IS 1865 Gr 400/15: Wedge:DI IS 1865 Gr 400/15: Body and Wedge Rings: Bronze IS: 318 Gr LTB2 Spindle: SS AISI 410, Fasteners: CS. Flange Drilling: IS 1538 Table 486, Operation - Manual and Electric Actuator(AUMA, Rotorek, Pneutork, Marsh Pneumatic, Elomatic make with inetegral starter), complete in all respect as per site requirement and to the satisfaction of Engineer-in-charge, of make IVC Nasik, VAG, Talis, Kirloskar. (NS Item) | 3 | Each | 4,92,712 | ₹14,78,136 |
| 1.03 | `Supply, installation, testing and commissioining of level indicator with transmitter (ultrasonic type) with 4 - 20 mA analoge output suitable for at HART communication including all other required accessories as required for measurement complete in all respect with SCADA compatibiltiy.Make Endress plus Hauser,Honeywell,Hycontrols,UK,ABB | 1 | NO. | 21,200 | ₹21,200 |
| 1.04 | `Supply,Installtion/Erection,testing and commissioning of Pressure Transmitter Bourdon Pressure Gauge with their accessories at site, confirming to the tender/system requirement and technical specification complete in all respects up to the entire satisfaction of Engineer-In charge of the works.
Make:ABB,Warne,Endress plus Hauser,Hach. | 2 | NO. | 18,000 | ₹36,000 |
| 1.05 | Providing and fixing Stainless Steel Wall mounted Bracket
Supports to support Verticle Pipe Scheme for Pump Chamber
for diameter of pipe -250 mm Ø for Pumping Scheme. | 6 | Each | 12,874 | ₹77,244 |
| 1.06 | Supply and laying of Premier Insulating Mat `B` calss as per IS-15652:2006 (NSR)` | 10 | Sqm | 1,028 | ₹10,280 |
| 1.07 | `Wall Mounted S.S. Support Brackets for Vertical Portions of Pipe
(NSR)`
For 400 mm Ø- Pipe | 6 | Metre | 20,598 | ₹1,23,588 |
| 1.08 | `Supply, inspection testing commissioning and laying of steel strip armoured XLPE insulated cable laid in ground cable, loose in existing pipe, trenches and Cable Tray etc. as required complete with necessary connections.
(NSR)`
4 C x 4 sqmm CU XLPE Insulated power cable for actuator power supply
Make: Finolex / Fort Closter / KEI/ L andT or approved make | 400 | Metre | 391 | ₹1,56,400 |
| 1.09 | `Supply, inspection testing commissioning and laying of steel strip armoured XLPE insulated cable laid in ground cable, loose in existing pipe, trenches and Cable Tray etc. as required complete with necessary connections.Make:Finolex / Fort Closter / KEI/ L andT or approved make
(NSR)`
7 C x 1.5 sqmm CU XLPE Insulated control cable | 400 | Metre | 248 | ₹99,200 |
| 1.1 | `Supply, inspection testing commissioning and laying of steel strip armoured XLPE insulated cable laid in ground cable, loose in existing pipe, trenches and Cable Tray etc. as required complete with necessary connections.Make:Finolex / Fort Closter / KEI/ L andT or approved makes
12 C X 1.5 Sqmm CU XLPE Insulated control cable | 50 | Metre | 459 | ₹22,950 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.41 MB
BOQ_626061.xls
BOQ • 0.44 MB
AD0178510.pdf
Additional Documents • 1.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .